DECLARATION OF PERFORMANCE

Similar documents
EN :2012 EN :2012 ETAG 026 part 3:2011 DECLARATION OF PERFORMANCE. Sikasil -670 Fire

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE

Declaration of Performance

in accordance with Annex 111 of Regulation (EU) No. 305/2011 ( Construction Products Regulation ) ULTRA PROFLEX SP+ES GREY

See product BS EN :2010

Declaration of Performance

Declaration of Conformity Declaration of Performance Notes

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE. No EN

DECLARATION OF PERFORMANCE. No EN

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 4

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE. DoP: 0124 for fischer Ceiling Anchor FDZ (Metal anchors for use in concrete (light-duty type)) EN

DECLARATION OF PERFORMANCE. No EN. Annexes B 1 to B 4

SYSTEM DATA SHEET Sikafloor MultiDur ES-44 ESD

DECLARATION OF PERFORMANCE. No EN

DECLARATION OF PERFORMANCE. DoP: 0135 for fischer injection system FIS EM Plus (Bonded anchor for use in concrete) EN

DECLARATION OF PERFORMANCE. No EN

European Technical Assessment

Guideline Construction Products Regulation (EU) 305/20122

DECLARATION OF PERFORMANCE. No EN

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 6

COMMISSION DELEGATED REGULATION (EU)

Technical Bulletin CE marking: from 1st July 2013

DECLARATION OF PERFORMANCE. No EN

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

DECLARATION OF PERFORMANCE. DoP: 0094 for Injection System fischer FIS V (Bonded anchor for use in concrete) EN

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

European Technical Assessment

DECLARATION OF PERFORMANCE

European Technical Assessment

ETICS and the EU Internal Market The European framework. G. Katsarakis European Commission, DG GROWTH Unit C-1: Clean technologies and products

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

F O C U S D O O R C L O S E R S

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 9

Implementing the Construction Products Regulation (EU) 305/2011

CE marking of noise barriers and foundations

YOUR GUIDE TO UNDERSTANDING CPR

EUROPEAN TECHNICAL ASSESSMENT

European Technical Assessment. ETA-14/0125 of 26 May General Part. Technical Assessment Body issuing the European Technical Assessment:

European Technical Assessment ETA-14/0176

For structural use in all types of construction works according to EN

Your Key to achieving C.E Marking Compliance

Declaration of performance ( DoP ) :

1. Terms defined in the Construction Products Regulation (CPR)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

GNB-CPR Position Paper: Issuance of certificates under CPR

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

DECLARATION OF PERFORMANCE 1 N. For structural use in all types of construction works according to EN

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

Declaration of Performance and CE marking of windows and external pedestrian doorsets according to the CPR

EUROPEAN TECHNICAL ASSESSMENT

Guidance on Declaration of Performance and CE marking of windows and external pedestrian doorsets according to the CPR

Introduction. Declaration of performance (DoP) CE marking

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Stanley Black & Decker Deutschland GmbH Richard-Klinger-Straße Idstein DEUTSCHLAND. Manufacturing plant Manufacturing Plant 4 and Plant 9

CPR Guide: EU Rules Practical Impact

Co-ordination of the Group of Notified Bodies for the Construction Products /Regulation 305/2011/EU

CPR Guide: EU Rules Practical Impact

Guidance Note No 19/1. CE Marking windows and doorsets

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

Firetect C. Fire protective products: Fire protective board

System Solutions. Quick and simple to construct. Range of partitions. Fully warranted systems. CE Marked. Knauf CE Marking. A guide to CE marking

European Technical Assessment. ETA-12/0166 of 18 June English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-15/0771 of 14 December English translation prepared by DIBt - Original version in German language

Roofing Adhesive SARNACOL 2172 Spray

European Technical Assessment. ETA-13/0651 of 18 June English translation prepared by DIBt - Original version in German language.

COMMISSION DELEGATED REGULATION (EU) /... of

European Technical Assessment. ETA-14/0030 of 26 June General Part. Technical Assessment Body issuing the European Technical Assessment:

CE marking of industrial doors under the CPR Michael Skelding, Secretary and General Manager Door and Hardware Federation

Guidance Note on the Construction Products Regulation

DECLARATION OF PERFORMANCE. BS EN 1338:2003 Precast Concrete Paving Blocks DoP M-03

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

European Technical Assessment. ETA-08/0315 of 15 May General Part. Technical Assessment Body issuing the European Technical Assessment:

Reaction to fire classification report No C-rev.1

The effects on the UK Fire Industry. Paul Pope Eng.Tech AIFireE

DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW!

European Technical Assessment. ETA-17/0624 of 8 September English translation prepared by DIBt - Original version in German language

European Technical Assessment

European Technical Assessment

European Technical Assessment. ETA-05/0069 of 5 August English translation prepared by DIBt - Original version in German language.

Trade name of the construction product Fix Master Injection system Fit-Ve 200 for rebar connection. Karhutie 9 Fl NURMIJÄRVI FINNLAND

European Technical Assessment. ETA-05/0069 of 3 July English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-13/0136 of 20 March English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-10/0352 of 6 July English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-02/0024 of 17 June English translation prepared by DIBt - Original version in German language.

rebar connection Fosroc International Limited Drayton Manor Business Park Coles Road TAMWORTH STAFFORDSHIRE; B78 3XN GROSSBRITANNIEN

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

European Technical Assessment. ETA-10/0255 of 22 August General Part. Technical Assessment Body issuing the European Technical Assessment:

European Technical Assessment. ETA-16/0693 of 29 August English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-11/0492 of 26 June General Part. Technical Assessment Body issuing the European Technical Assessment:

Reaction to fire classification report No C

SD119 Range of Conventional Smoke and Smoke/Heat Detectors (refer to attached appendix for details and conditions)

Trade name of the construction product Injection system Hilti HIT-HY 110. This version replaces ETA-13/1037 issued on 17 January 2014

European Technical Assessment. ETA-07/0121 of 30 March English translation prepared by DIBt - Original version in German language.

Transcription:

EN 15651-1:2012 EN 15651-2:2012 14 1119 DECLARATION OF PERFORMANCE Sikasil WS-605 S 01 26 03 01 011 9 001000 1024 1. Product Type: Unique identification code of the product-type: 2. Type batch or serial number or any other element allowing identification of the construction product as required under Article 11(4): 3. Intended use or uses of the construction product, in accordance with the applicable harmonised technical specification, as foreseen by the manufacturer: 4. Name, registered trade name or registered trade mark and contact address of the manufacturer as required under Article 11(5): 5. Contact Address: Where applicable, name and contact address of the authorized representative whose mandate covers the tasks specified in Article 12(2): 6. AVCP: System or systems of assessment and verification of constancy of performance (AVCP) of the construction product as set out in CPR, Annex V: 7. Notified body (hen): In case of the declaration of performance (DoP) concerning a construction product covered by a harmonised standard: 8. Notified body (ETA): In case of the declaration of performance concerning a construction product for which a European Technical Assessment (ETA) has been issued: Sikasil WS-605 S See packaging of the product Sealant for facade for interior and exterior application (intended for use in cold climates) F EXT-INT CC 25LM, (F EXT-INT 25LM for transparent) Sealant for glazing (intended for use in cold climates) G CC 25LM Sikasil Sika Services AG, Tüffenwies 16 CH-8048 Zürich, Switzerland Not relevant System 3 for the type testing System 3 for the reaction to fire testing The notified body Kiwa Polymer Institut GmbH, identification number 1119, performed the type testing and the testing of the reaction to fire and issued test report and classification report. Not relevant Italy www.sika.com/ses Page 1 / 6

9. 9.1 According to EN 15651-1:2012 Mortar M1, Sika Primer-210 Essential characteristics Performance Test standard Harmonised technical specification Reaction to fire Class E EN ISO 13238 Classification acc. EN 13501-1:2010 Release of chemicals dangerous to the environment and health Evaluated EN 15651-1:2012; 4.5 Resistance to flow 3 mm EN ISO 7390 Loss of volume 10 % EN ISO 10563 Tensile properties at maintained extension after water immersion (elastic) NF at 100% elongation EN ISO 10590 Secant tensile modulus at -30 C 0.9 MPa EN ISO 8339 Tensile properties for nonstructural sealants used in joints in cold climate areas (-30 C) NF EN ISO 8340 modified Durability pass EN ISO 8339 EN ISO 8340 EN ISO 9047 EN ISO 10590 EN 15651-1:2012 Italy www.sika.com/ses Page 2 / 6

9.2 According to EN 15651-2:2012 Glass Essential characteristics Performance Test standard Harmonised technical specification Reaction to fire Class E EN ISO 13238 Classification acc. EN 13501-1:2010 Release of chemicals dangerous to the environment and health Evaluated EN 15651-1:2012; 4.4 Loss of volume 10 % EN ISO 10563 Resistance to flow 3 mm EN ISO 7390 Adhesion/cohesion properties after exposure to heat water and artificial light NF at 60% elongation Elastic recovery 60% at 60% elongation EN ISO 11431 EN ISO 7389 Secant tensile modulus at -30 C 0.9 MPa EN ISO 8339 Tensile properties for nonstructural sealants used in joints in cold climate areas (-30 C) NF EN ISO 8340 modified Durability pass EN ISO 8339 EN ISO 8340 EN ISO 9047 EN ISO 10590 EN 15651-2:2012 Italy www.sika.com/ses Page 3 / 6

10. Declaration The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 9.This declaration of performance (DoP) is issued under the sole responsibility of the manufacturer identified in point 4. Signed for and on behalf of the manufacturer by: Ulli Mueller Head Market Field Engineering Sika Services AG Peschiera Borromeo, 01.07.2014 Caterina Malanchini CFO Manager Ecology, Health and Safety Information (REACH) For information and advice on the safe handling, storage and disposal of chemical products, users shall refer to the most recent Safety Data Sheet (SDS) containing physical, ecological, toxicological and other safety related data. Italy www.sika.com/ses Page 4 / 6

1119 1024 14 01 26 03 01 011 9 001000 1024 EN 15651-1:2012 Sealant for facade for interior and exterior application (intended for use in cold climates) F EXT-INT CC 25LM, (F EXT-INT 25LM for transparent) Essential characteristics Reaction to fire Mortar M1, Sika Primer-210 Release of chemicals dangerous to the environment and health Performance Class E Evaluated Resistance to flow 3 mm Loss of volume 10 % Tensile properties at maintained extension after water immersion (elastic) Secant tensile modulus at -30 C 0.9 MPa Tensile properties for non-structural sealants used in joints in cold climate areas (-30 C) Durability NF at 100% elongation NF pass Italy www.sika.com/ses Page 5 / 6

Glass Essential characteristics Reaction to fire Release of chemicals dangerous to the environment and health 1119 1024 14 01 26 03 01 011 9 001000 1024 EN 15651-2:2012 Sealant for glazing (intended for use in cold climates) G CC 25LM Performance Class E Evaluated Loss of volume 10 % Resistance to flow 3 mm Adhesion/cohesion properties after exposure to heat water and artificial light Elastic recovery 60% Secant tensile modulus at -30 C 0.9 MPa Tensile properties for non-structural sealants used in joints in cold climate areas (-30 C) Durability NF at 60% elongation Legal note: This information is given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. NF pass Italy www.sika.com/ses Page 6 / 6