electronic wire pocket-picker edition 7/06 Low voltage electronic wire specialists

Similar documents
Fire Alarm/Life Safety Cable 6

WIRE & CABLE. Wire & Cable... Wire Accessories...

WIRE & CABLE. Wire & Cable... Wire Accessories...

Quick Reference Applications Guide

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

Security & Control Cables

NewGeneration Cables. BELDENCable TM

Company Profile. We are dedicated to providing our customers competitive price and excellent service.

SOUND/SECURITY FIRE ALARM/LIFE SAFETY TEMPERATURE CONTROLS COAXIAL DATACOM HARDWARE FIBER OPTIC SPECIAL APPLICATION CATALOG, VOL.

PAIRED UNJACKETED. Insulation Nominal Anixter. Paired Conductors Thickness O.D. Number AWG Strand No. IN IN

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

Alarm & Security SOLUTIONS. Access Control Video Surveillance Fire Alarm Life Safety

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

SHIELD TYPE MULTICONDUCTOR MULTIPAIR

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

Genesis. Series Low Voltage Cable. Honeywell Cable Catalog

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

Honeywell Cable & Custom Electronics

Fire Alarm Cables. Features: Countdown. New Labeling System on box. Color Coded Boxes. Zone and Room Markings

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Genesis Cable Audio/Video Product Catalog DELIVERING THE ULTIMATE AUDIO/VIDEO EXPERIENCE

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

BELDEN LOW VOLTAGE COPPER CABLE PLENUM RATED

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Home Theater Cables. Your complete solution for high-end audio transmission, stereo, professional audio systems and home theater systems.

Honeywell Cable. We ve got a cable for that!

Comtran s VITALink 2 Hour Fire Resistive CIC & CI Free Air Cables. Your trusted solution for fire safety

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

SAS Security and Alarm Safety Cables

CATEGORY 6A FTP RJ45 SOLUTION

5. Identification products.

Second Revision No. 601 NFPA [ Section No [Excluding

Caledonian Flame Retardant Coaxial Cables

Comtran Cable. Hub-LINK Cables for Transit Applications

AFC Cable Systems: the Cable Industry Leader for Over 80 Years

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

CABLES FOR ALARM AND SAFETY SYSTEMS

Genesis Series Cable THE POWER OF CHOICE. Cables for Silent Knight

Genesis Cable Audio/Video Product Catalog DELIVERING THE ULTIMATE AUDIO/VIDEO EXPERIENCE

Compact Module. Category 6A FTP Cabling System 1.1

Fire Alarm Systems ARTICLE. Introduction to Article 760 Fire Alarm Systems. Part I. General

Multi-Core Fire Resistant Cable

Vista-50P/-50PUL System Design Sheet

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

(800) 292- omnicable.com CABLE ACCESSORIES GUIDE

Vista-10SE System Design Sheet

Category 5 Premise Wire

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

Vista-20SEUL System Design Sheet

Caledonian Fire resistant Coaxial Cables

Flexible Power Cable DLO

Print Specification. Publication. Instructions. Specific requirements. General requirements

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION (13740) - VIDEO SURVEILLANCE

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Catalogue Telecommunication Cables INTRODUCCIÓN

Belden Infinity C-TC+ Cables for Extreme Flexing

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

Vista-128FB System Design Sheet

Brand Portable Power Cord & Control Cable Solutions

.2 Section Waste Management and Disposal..4 Section Electrical General Requirements.

Texas Based UL Alarm System Monitoring. Alarm System Monitoring Up to 128 zones $34.95 per month 25.00% $26.22

SIGA-CC1 Single Input Signal Module Installation Sheet

SECTION COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

SECTION ELECTRICAL IDENTIFICATION

TAA COMPLIANT. 15Year Limited Warranty. 1Year Limited Warranty. 25Year Limited Warranty. Intertek. Intertek SPECIAL STANDARD EXTENDED

commercial-type cabling and connectivity products into the industrial landscape.

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

Oberon s National Electric Code (NEC)Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

SECTION COMMUNICATIONS HORIZONTAL CABLING

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

E3 Series Broadband System

4120 Fire Alarm Network Reference

System Accessories, LCD Annunciators

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247

Wire and Cable The Industry Standard for Rugged, Reliable Performance

Special Provision No. 683S28 December 2017

FEB. 17 Rev. A1

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

. SECTION CONTROL-VOLTAGE ELECTRICAL POWER CABLES

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

SECTION INTRUSION DETECTION SYSTEM

Fee $15 Course: NEC Changes 5 This course is valid for these credentials: Credential Description Cred Code Credit Hours

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

High Performance LSZH Fire Resistant Cable

E3 Series Broadband System

Telecommunication Cables

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 27 COMMUNICATIONS SECTION PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEMS

NEC 2017 Changes and Their Effect Upon the ICT Industry

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Speedlock AMC Connectors...KA1. Armored Cable Connectors...KB1-KB5 Metal Clad Cable Connectors...KB1-KB5 Flexible Metal Conduit Connectors...

Transcription:

electronic wire edition 7/06 pocket-picker Low voltage electronic wire specialists

Contact Guide TOLL FREE Henry Coffey 800-37-3 Frank Conaty 888-3-897 Clark Feland 800-8-7137 Kathy Knoch 800-677-3 Jodi Lauren 800-37-3 Krysta McCrea 800-37-3 Richard Moon 800-37-3 Dan Pritchard 800-997-3 Brad Schneider 800-997-3 Roxanne Tobia 800-37-3 Linda Todaro 800-37-3 www.paigeelectric.com

electronic wire edition 10/0 pocket-picker

APPLICATION INDEX USE SECTION PAGE VDC Power (Distinguisher) Fire Alarm Systems 3 Annunciator Comm. (Distinguisher) Fire Alarm Systems 3 Annunciator Power (Distinguisher) Fire Alarm Systems 3 Category 3, 5e & 6 LAN, Data, Networking Solutions 9 CATV Coaxial Cables 1 CCTV Coaxial Cables 1 Contacts Sound & Security Systems 5 Data Comm. SLC (Distinguisher) Fire Alarm Systems 3 Data Comm. SLC Fire Alarm Systems 3 Data Sound & Security Systems 5 Fire Phone Fire Alarm Systems 3 Glass Break Sensors Sound & Security Systems 5 Heat Detector Fire Alarm Systems 3 Heater Power Coaxial Cables 1 Horn (Distinguisher) Fire Alarm Systems 3 Horn Fire Alarm Systems 3 Intercom Sound & Security Systems 5 Keypad Fire Alarm Systems 3 Keypad Sound & Security Systems 5 Lock Power Sound & Security Systems 5 Microphone Sound & Security Systems 5 Motion Detectors Sound & Security Systems 5 Networking LAN, Data, Networking Solutions 9 Paging / Sound Sound & Security Systems 5 Pan / Tilt / Zoom Coaxial Cables 1 Panic Station Fire Alarm Systems 3 Patch Cables Coaxial Cables 1 Power Sound & Security Systems 5 Power (camera) Coaxial Cables 1 Reader Cable Sound & Security Systems 5 Request To Exit Sound & Security Systems 5 Smoke Detector Fire Alarm Systems 3 Sounder Base Fire Alarm Systems 3 Sounder Cable Sound & Security Systems 5 Speakers (Distinguisher) Fire Alarm Systems 3 Speakers Sound & Security Systems 5 Strobe (Distinguisher) Fire Alarm Systems 3 Strobe Fire Alarm Systems 3 Telephone LAN, Data, Networking Solutions 9 Thermostat Thermostat 59 Video Signal Coaxial Cables 1 Water Sensors Sound & Security Systems 5

TABLE OF CONTENTS Sound & Security Systems 5 Multi-Conductor, Unshielded, Non-Plenum 7-9 Multi-Conductor, Unshielded, Plenum 15-16 Multi-Conductor, Shielded, Non-Plenum 10-1 Multi-Conductor, Shielded, Plenum 17-18 Multi-Pair, Individually Shielded, Non-Plenum 13 Multi-Pair, Individually Shielded, Plenum 19 Multi-Pair, Shielded + Unshielded, Non-Plenum 1 Multi-Pair, Shielded + Unshielded, Plenum 0 Composite Cable, Plenum 1- Fire Alarm SystemS 3 Circuit Integrity (CI), Non-Plenum 36 Distinguisher Circuit Tracer 3-3 Metal Clad 38-0 Multi-Conductor, Unshielded, Non-Plenum 6-7 Multi-Conductor, Unshielded, Plenum 9 Multi-Conductor, Shielded, Non-Plenum 7 Multi-Conductor, Shielded, Plenum 30 Mid-Capacitance, Shielded, Non-Plenum 8 Mid-Capacitance, Shielded, Plenum 31 Non-Twisted, Plenum 37 Sounder Base, Plenum 3 TFN / THHN Non-Plenum 5 Zip Wire, Non-Plenum 37 Coaxial Cable 1 CATV Non-Plenum 3 CATVP Plenum 6 CATV RGB Composite Video (RGBHV) 5 CCTV Non-Plenum CCTV Plenum 7 Patch Cables 8 Outdoor 71 LAN, Data & Networking Solutions 9 Category 3 UTP, Non-Plenum 51 Category 3 UTP, Plenum 5 Category 5e UTP, Non-Plenum 53 Category 5e STP, Non-Plenum 53 Category 5e UTP, Plenum 5 Category 5e STP, Plenum 5 Category 5e Powersum, Plenum 55 Category 5e Direct Burial 75 Category 5e Patch Cables 56-57 Category 6 UTP, Non-Plenum & Plenum 58 Thermostat CabLE 59 Multi-Conductor, Unshielded, Plenum 61 Outdoor Cable 63 Aerial or Direct Burial Multi-Conductor, Unshielded 66-67 Multi-Conductor, Overall Shielded 68 Multi-Pair, Overall Shielded 69 Aerial or Conduit Burial Multi-Pair, Individually Shielded 70 Coaxial 71 Category 5 7 Messenger Cable 73 Fiber Optic CabLE 75 Indoor Plenum 80 Indoor / Outdoor Riser 81 Indoor / Outdoor Plenum 8 Self-Supporting Aerial 83 ADSS Hardware & Accessories 8 Connectors & Accessories 85 Technical Information 87 NEC Made Easy 88-91 Copper Wire 9-93 Installation Calculations 9-96 Conversion Tables 97 Custom CabLES 99 Electronic Cable Design 100 Parameter Punch List 101 Cross References 103 Belden Cross Reference 10-106 West Penn Cross Reference 107-109 Quick Reference 110-118 3

SOUND & SECURITY SYSTEMS Paige sound and security cables are designed for a wide range of applications in low voltage sound and security systems. They carry the following listings in common. 75 C Temperature rated 300 volt UL Listed and Canadian UL Listed Meet NEC Articles 800 and 75 Most are dual listed to also meet NEC Articles 760 permitting cross application in fire alarm systems Dual NEC / UL Listings for cables in this section: Gauge Sizes Non-plenum Non-plenum Riser Plenum AWG 16 AWG CM/FPL CMR/FPLR CMP/FPLP 1 AWG 1 AWG CL3/FPL CL3R/FPLR CL3P/FPLP For additional information on NEC / UL see p. 88-91 in the technical section. Additional features of cables in this section: Twisted conductors for reduced cross-talk ASTM bare copper conductors Premium grade PVC for improved strength and flexibility When shielded, corrosion resistant tinned copper drain wires are used Color-coded conductors 5

SOUND & SECURITY SYSTEMS CONDUCTOR COLOR CHART Color Code 1 1 Black Red 3 White Green 5 Brown 6 Blue 7 Orange 8 Yellow 9 Purple 10 Gray 11 Pink 1 Tan 13 White / Black 1 White / Red 15 White / Green 16 White / Orange 17 White / Blue 18 White / Brown 19 White / Yellow 0 White / Purple 1 White / Gray Black / Red 3 Black / Green Black / Yellow 5 Black / Blue 6 Black / Brown 7 Black / Orange 8 Black / Gray 9 Black / Purple 30 Red / Green Color Code 1 3 5 6 7 8 9 10 11 1 Black Red Brown Blue Orange Yellow Purple Green Red / Black Red / White Red / Green Red / Blue Color Code 8 Pair # 1st/nd 1 Black / Red Black / White 3 Black / Green Conductor Colors BE Beige PK Pink BK Black PR Purple BL Blue RE Red BR Brown VI Violet GN Green WH White GR Gray YW Yellow OR Orange Pair # 1 3 5 6 7 8 9 10 11 1 13 1 15 16 17 18 19 0 1 3 5 6 7 Color Code 1st Conductor Black / Red Black / White Black / Green Black / Blue Black / Yellow Black / Brown Black / Orange Red / White Red / Green Red / Blue Red / Yellow Red / Brown Red / Orange Green / White Green / Blue Green / Yellow Green / Brown Green / Orange White / Blue White / Yellow White / Brown White / Orange Blue / Yellow Blue / Brown Blue / Orange Brown / Yellow Brown / Orange nd Conductor Red White Green Blue Yellow Brown Orange White Green Blue Yellow Brown Orange White Blue Yellow Brown Orange Blue Yellow Brown Orange Yellow Brown Orange Yellow Orange 6

SOUND & SECURITY SYSTEMS NON-PLENUM CMR ASTM Bare Copper High Grade PVC Insulation Twisted/Cabled Conductors Riser Rated Gray PVC Jacket MULTI-CONDUCTOR UNSHIELDED AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 5606Axx 5607Axx 5665AGR 5608Axx* Solid 7 x 30 7 x 30 Solid 3.13.13.158.116 Access Control Security Devices Sound & Audio Intercom Paging Background Music 5609Axx 7 x 30.135 5610AGR Solid 6.173 5611AGR 7 x 30 6.180 561AGR Solid 8.181 5613AGR 7 x 30 8.186 561AGR Solid 10.187 5615AGR 7 x 30 10.0 5616AGR Solid 1.05 5617AGR 7 x 30 1.50 5666AGR 0 7 x 8.136 5618AGR 0 7 x 8 3.160 5667AGR 0 7 x 8.183 590AGR 0 7 x 8 8.1 Conductor color code 1. Chart on page 6. Non-Stock, Call for Availability. *Conductor colors are RE, GN, YW, BK and have a random twist. 7

SOUND & SECURITY SYSTEMS NON-PLENUM CMR ASTM Bare Copper High Grade PVC Insulation Twisted/Cabled Conductors Riser Rated Gray PVC Jacket MULTI-CONDUCTOR UNSHIELDED AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 59AGR 5703Axx 560AGR 5668AGR 0 7 x 8 18 Solid 18 7 x 6 18 7 x 6 1 3.65.161.17.179 Access Control Security Devices Sound & Audio Intercom Paging Background Music 570Axx** 18 Solid.175 563AGR 18 7 x 6.00 56GR 18 7 x 6 5.85 5669AGR 18 7 x 6 6.90 5670AGR 18 7 x 6 8.71 59AGR 18 7 x 6 10.87 5671AGR 18 7 x 6 1.76 5656AGR 16 19 x 9.198 5673AGR 16 19 x 9 3.19 5619AGR 16 19 x 9.36 Conductor color code 1. Chart on page page 6. Non-Stock, Call for Availability. **Conductor color code 8

SOUND & SECURITY SYSTEMS NON-PLENUM CL3R ASTM Bare Copper High Grade PVC Insulation Twisted/Cabled Conductors Riser Rated Gray PVC Jacket MULTI-CONDUCTOR UNSHIELDED AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 567AGR 5671GR 5675AGR 5676AGR 1 19 x 6 1 19 x 6 1 19 x 6 1 19 x 5 3.39.58.75.90 Access Control Security Devices Sound & Audio Intercom Paging Background Music 56761GR 1 19 x 5 3.310 Conductor color code 1. Chart on page page 6. Non-Stock, Call for Availability. 9

SOUND & SECURITY SYSTEMS NON-PLENUM MULTI-CONDUCTOR, OVERALL SHIELDED CMR ASTM Bare Copper High Grade PVC Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Riser Rated Gray PVC Jacket AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 5677AGR 560AGR 5678AGR 561AGR Solid 7 x 30 7 x 30 7 x 30 3.10.13.10.155 Access Control Security Devices Sound & Audio Intercom Paging Background Musi 56AGR 7 x 30 6.180 563AGR 7 x 30 8.190 5679AGR 7 x 30 10.10 565AGR 7 x 30 1.0 5680AGR 0 Solid.1 5681AGR 0 7 x 8 3.19 568AGR 0 7 x 8.16 5683AGR 18 Solid.15 565AGR 18 7 x 6.155 568AGR 18 7 x 6 3.160 566AGR 18 7 x 6.189 566AGR 18 7 x 6 6.11 5685AGR 18 7 x 6 8.30 Conductor color code 1. Chart on page page 6. * Non-Stock, Call for Availability. 10

SOUND & SECURITY SYSTEMS NON-PLENUM MULTI-CONDUCTOR OVERALL SHIELDED CMR ASTM Bare Copper High Grade PVC Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Riser Rated Gray PVC Jacket AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 567AGR 597AGR 5686AGR 16 19 x 9 16 19 x 9 16 19 x 9 3.19.07.36 Access Control Security Devices Sound & Audio Intercom Paging Background Music CL3R 568AGR 5687AGR 1 19 x 6 1 19 x 5.3.90 Access Control Security Devices Sound & Audio Intercom Paging Background Music Conductor color code 1. Chart on page page 6. Non-Stock, Call for Availability. 11

SOUND & SECURITY SYSTEMS NON-PLENUM Data and Communications Grade Multi-Conductor, Overall Shielded Low & Mid Capacitance CM ASTM Bare or Tinned Copper Polypropylene or Polyethylene Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Gray PVC Jacket AWG & STRANDING NO. OF COND. NOM CAPACITANCE 56001AGR 7 x 3.18 1.5 pf / ft 560GR 7 x 30 TC.160.9 pf / ft 599AGR 18 7 x 6.0.0 pf / FT Microphone Cable, Mini-Audio Multi-Conductor, Overall Shielded Mid-Capacitance 5601BK 7 x 30 TC.135 3.0 pf / ft Conductor color code 1. Chart on page page 6. * Non-Stock, Call for Availability. 1

SOUND & SECURITY SYSTEMS NON-PLENUM CMR ASTM Bare or Tinned Copper High Grade PVC Insulation Aluminum Polyester Foil Shields with individual drains Paired Conductors Gray PVC Jacket MULTI-PAIR INDIVIDUALLY SHIELDED AWG & STRANDING NO. OF PAIRS NOM POSSIBLE USE & APPLICATIONS 5655AGR 561GRB 55EQGY 5681GR* 7 x 30 7 x 30 Solid TC 0 7 x 8 3 3 15 3.19.35.390.51 Access Control Security Devices Sound & Audio Intercom Paging Background Music 5910AGR* 18 7 x 6 3.307 MULTI-PAIR INDIVIDUAL & OVERALL SHIELDED 561GRR 7 x 30.30 Conductor color code. overall shielded pairs Non-Stock, Call for Availability. *Conductor color code 8. Chart on page page 6. 13

SOUND & SECURITY SYSTEMS NON-PLENUM Intercom and Sound Systems Multi-Pair, Shielded & Unshielded CMR ASTM Bare Copper High Grade PVC Insulation Aluminum Polyester Foil Shield with drain Paired Conductors Riser Rated Gray PVC Jacket AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 5601GR 5611GR 5631GR 7 x 30 7 x 30 Solid 3 ( Shielded) (1 Unshielded) ( Shielded) ( Unshielded) 3 ( Shielded) (1 Unshielded).1.19.117 Access Control Security Devices Sound & Audio Intercom Paging Background Music 56GRB Solid ( Shielded) ( Unshielded).161 560GR Solid 6 ( Shielded) ( Unshielded).197 56801GR 0 7 x 8 3 ( Shielded) (1 Unshielded).155 56803GR 0 7 x 8 ( Shielded) ( Unshielded).168 59091GR 18 7 x 6 ( Shielded).197 Conductor color code: SHIELDED: 1. Black,. Red UNSHIELDED: 3. White,. Green, 5. Brown, 6. Blue Non-Stock, Call for Availability. 1

SOUND & SECURITY SYSTEMS PLENUM CMP ASTM Bare Copper Premium LS PVC Insulation Twisted/Cabled Conductors Plenum Rated White Poly-flex Jacket MULTI-CONDUCTOR, UNSHIELDED AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 568Axx 569Axx 591AWH 569AWH Solid 7 x 30 7 x 30 Solid 3.115.10.13.15 Access Control Security Devices Sound & Audio Intercom Paging Background Music 5650AWH 7 x 30.139 565AWH 7 x 30 6.159 5689AWH 7 x 30 8.170 5690AWH 7 x 30 10.00 5653AWH 7 x 30 1.11 56511WH 0 7 x 8.130 5630AWH 18 Solid.13 561Axx 18 7 x 6.150 5691AWH 18 7 x 6 3.160 56AWH 18 7 x 6.175 5659AWH 18 7 x 6 6.08 569AWH 18 7 x 6 8.7 5693AWH 18 7 x 6 10.68 Conductor color code 1. Chart on page page 6. Non-Stock, Call for Availability. 15

SOUND & SECURITY SYSTEMS PLENUM CMP ASTM Bare Copper Premium LS PVC Insulation Twisted/Cabled Conductors Plenum Rated White Poly-flex Jacket MULTI-CONDUCTOR, UNSHIELDED AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 569AWH 569WH 5695AWH 16 19 x 9 16 19 x 9 16 19 x 9 3.170.181.10 Access Control Security Devices Sound & Audio Intercom Paging Background Music CL3P 5696AWH 56961WH 5697AWH 5698AWH 1 19 x 6 1 19 x 6 1 19 x 6 1 19 x 5 3.13.7.7.8 Access Control Security Devices Sound & Audio Intercom Paging Background Music Conductor color code 1. Chart on page page 6. * Non-Stock, Call for Availability. 16

SOUND & SECURITY SYSTEMS PLENUM MULTI-CONDUCTOR, OVERALL SHIELDED CMP ASTM Bare Copper Premium LS PVC Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Plenum Rated White Poly-flex Jacket AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 56991WH 5699AWH 5900AWH 5631AWH Solid 7 x 30 7 x 30 7 x 30 3.115.118.15.139 Access Control Security Devices Sound & Audio Intercom Paging Background Music 5660AWH 7 x 30 6.158 5901AWH 7 x 30 8.175 590AWH 7 x 30 10.10 5903AWH 7 x 30 1.0 5937AWH 0 7 x 8.15 563AWH 18 Solid.138 56Axx 18 7 x 6.153 590AWH 18 7 x 6 3.161 565AWH 18 7 x 6.183 567AWH 18 7 x 6 6.08 5905AWH 18 7 x 6 8.30 5906AWH 18 7 x 6 10.300 5907AWH 16 19 x 9.185 597AWH 16 19 x 9.10 Conductor color code 1. Chart on page page 6. * Non-Stock, Call for Availability. 17

SOUND & SECURITY SYSTEMS PLENUM CL3P ASTM Bare Copper Premium LS PVC Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Plenum Rated White Poly-flex Jacket MULTI-CONDUCTOR, OVERALL SHIELDED AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 5908AWH 5913AWH 593AWH 1 19 x 6 1 19 x 6 1 19 x 5.3.5.80 Access Control Security Devices Sound & Audio Intercom Paging Background Music Data and Communications Grade Multi-Conductor, Overall Shielded Low Capacitance CMP ASTM Bare Copper LoCap FPR Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Plenum Rated White Poly-flex Jacket AWG & STRANDING NO. OF COND. NOM CAPACITANCE 5600AWH 7 x 3.136 1.0 pf / ft 5699WH 7 x 30.18 1.5 pf / ft Conductor color code 1. Chart on page page 6. Non-Stock, Call for Availability. 18

SOUND & SECURITY SYSTEMS PLENUM CMP ASTM Bare or Tinned Copper Premium LS PVC Insulation Aluminum Polyester Foil Shields with individual drains Paired Conductors Plenum Rated White Poly-flex Jacket MULTI-PAIR, INDIVIDUALLY SHIELDED AWG & STRANDING NO. OF PAIRS NOM POSSIBLE USE & APPLICATIONS 5631WH 5630WH* 56601WHB 568WH 7 x 30 7 x 30 7 x 30 7 x 30 3.19.00.05.0 Access Control Security Devices Sound & Audio Intercom Paging Background Music 5630WH 7 x 30 6.58 55EQPL Solid TC 15.350 5939AWH 18 7 x 6.58 590AWH 18 7 x 6 3.78 * Individually shielded pairs + overall shield Conductor color code 1. Chart on page page 6. Non-Stock, Call for Availability. 19

SOUND & SECURITY SYSTEMS PLENUM CMP ASTM Bare Copper Premium LS PVC Insulation Aluminum Polyester Foil Shield with drain Paired Conductors Plenum Rated White Poly-flex Jacket Intercom and Sound Systems Multi-Pair, Shielded & Unshielded AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 56307WH 563WHR 5631WHR 7 x 30 Solid 7 x 30 3 ( Shielded) (1 Unshielded) ( Shielded) ( Unshielded) ( Shielded) ( Unshielded).137.133.19 Access Control Security Devices Sound & Audio Intercom Paging Background Music 56WH Solid 6 ( Shielded) ( Unshielded).185 56WH 7 x 30 6 ( Shielded) ( Unshielded).199 5635AWH 0 7 x 8 ( Shielded) ( Unshielded).159 590WH 18 7 x 6 ( Shielded).180 Conductor color code: SHIELDED: 1. Black,. Red UNSHIELDED: 3. White,. Green, 5. Brown, 6. Blue Non-Stock, Call for Availability. 0

SOUND & SECURITY SYSTEMS PLENUM CMP ASTM Bare Copper Premium LS PVC Insulation Aluminum Polyester Foil Shield with individual drains Twisted/Cabled Conductors Individual Plenum Rated Component Jackets Overall Plenum FPR Jacket Access Control Composite Multi-Conductor, Individually Shielded & Jacketed Components Overall Jacket AWG & STRANDING NO. OF COND. NOM APPLICATION 593AYW 18 7 x 6 6 Shielded.51 Card Reader 18 7 x 6 Shielded Motion/Rex 7 x 30 Shielded Door Contacts 16 19 x 9 Shielded Lock Power Paige will custom design and specify any combination of ACCESS control composite cable. Just call Paige. Conductor color code 1. Chart on page page 6. 1

SOUND & SECURITY SYSTEMS PLENUM Access Control Composite Multi-Conductor, Individually Jacketed Components Shielded & Unshielded Components Bundled & Wrapped with Clear TapRibbon CMP ASTM Bare Copper Premium LS PVC Insulation Aluminum Polyester Foil Shield with individual drains Twisted/Cabled Conductors Individual Plenum Rated Component Jackets Clear Skip Wrapped Individually Jacketed White w/orange Stripe AWG & STRANDING NO. OF COND. OR PAIRS NOM APPLICATION 5W05 18 7 x 6 3 PR* OAS.5 Reader 16 19 x 9 C Unshielded Lock 7 x 30 C Unshielded Door Contacts 7 x 30 C Unshielded Rex Product Features a ribbon wrapped bundle to secure the individual components. Ribbon wrap offers better flexibility and lower cost than overall FPR plenum jackets. Clear ribbon allows for high visibility color coding of the access control components. Paige will custom design and specify any combination of ACCESS control composite cable. Just call Paige. Conductor color code 1. *Conductor color code 8. Chart on page page 6.

FIRE ALARM SYSTEMS Power Limited Cables Paige fire alarm cables are designed for a wide range of applications in low voltage fire alarm systems. They carry the following listings in common: NFPA MEMBER 006-007 75 C Temperature rated 300 volt UL Listed and Canadian UL Listed Most are dual listed to also meet NEC Articles 760 permitting cross application in sound and security systems Meet NEC Articles 800 and 75 Dual NEC / UL Listings for cables in this section: Gauge Sizes AWG 16 AWG Non-plenum FPL/CM Non-plenum Riser FPLR/CMR Plenum FPLP/CMP 1 AWG 1 AWG FPL/CL3 FPLR/CL3R FPLP/CL3P For additional information on NEC / UL see p. 88-91 in the technical section. Additional features of cables in this section: Twisted conductors for reduced cross-talk ASTM bare copper conductors Premium grade PVC for improved strength and flexibility When shielded, corrosion resistant tinned copper drain wires are used Color-coded conductors Cables Installed in Raceway For maximum installation flexibility, Paige offers a series of TFN and THHN, 600 volt cables, permitted for use in power limited fire alarm circuits under NEC Article 760.5 Wiring Methods and Materials on Load Side of the PLFA Power Source and sub-section 760.5(A) NPLFA Wiring Methods and Materials. When installed in accordance with NEC Chapter 3, these cables deliver a number of speedy installation advantages: Rated TFN (18 and 16 AWG) or THHN (1 and 1 AWG) 90 C dry / 75 C wet Rated 600 volts Available in singles or Easy-pull pre-twisted, color-coded pairs Available in flexible metal armor 3

FIRE ALARM SYSTEMS CONDUCTOR COLOR CHART Color Code 1 Black Red 3 Brown Blue 5 Orange 6 Yellow 7 Purple 8 Green 9 Red / Black 10 Red / White 11 Red / Green 1 Red / Blue Color Code 7 Cond # 18-16 AWG 1 Black Red 3 Blue Orange 1-1 AWG Black White Red Blue Conductor Colors BE BK BL BR GN Beige Black Blue Brown Green GR OR PK PR Gray Orange Pink Purple RE VI WH YW Red Violet White Yellow

FIRE ALARM SYSTEMS NON-PLENUM TFN or THHN ASTM Solid Bare Copper PVC & Nylon Insulation Twisted/Cabled Conductors Unjacketed PAIRED, UNJACKETED, UNSHIELDED 600V Low Capacitance AWG & STRANDING NO. OF COND. NOM CONDUCTOR COLORS 5318BR 18 Solid.165 Bk / Re 5316BR 16 Solid.190 Bk / Re 531BR 1 Solid. Bk / Re THHN ASTM Bare Copper PVC Insulation Nylon Jacket SINGLE CONDUCTOR, UNSHIELDED 600V AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 700151 1 19 x 6 1.11 BK, BL, BR, GN, PK, RE, VI, WH, YW 713 1 Solid 1.11 GN 5

FIRE ALARM SYSTEMS NON-PLENUM FPLR ASTM Bare Copper High Grade PVC Insulation Twisted/Cabled Conductors Riser Rated Red PVC Jacket MULTI-CONDUCTOR, UNSHIELDED AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 5606Axx 5703Axx 570Axx 5705ARE Solid 18 Solid 18 Solid 18 Solid 6.13.161.175.0 I/O SLC Loop Addressable Devices Power Horns/Strobes Panel Interconnects Speaker 5706ARE 18 Solid 8.0 5707ARE 18 Solid 10.80 5731Axx 16 Solid.186 576ARE 16 7 x.198 57ARE 16 Solid.16 5718Axx 1 Solid.0 5718RE 1 7 x.30 573ARE 1 Solid.6 570ARE 1 Solid.6 5733ARE 1 Solid.303 For non-twisted zip fire alarm cables, see page 37. Conductor color code. Chart on page. Non-Stock, Call for Availability. 6

FIRE ALARM SYSTEMS NON-PLENUM FPL ASTM Bare Copper Low Density PE Insulation Twisted/Cabled Conductors Red PVC Jacket DATA ADDRESSABLE CABLE Multi-Conductor, Unshielded Low Capacitance AWG & STRANDING NO. OF COND. NOM CAPACITANCE 5703RE 18 Solid.17 16.0 pf / FT 57311RE 16 Solid. 18.6 pf / FT MULTI-CONDUCTOR, OVERALL SHIELDED FPLR ASTM Bare Copper High Grade PVC Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Riser Rated Red PVC Jacket AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 57ARE 573ARE 5735ARE 5736ARE 18 Solid 18 Solid 18 Solid 16 Solid 6.161.189.31.161 I/O SLC Loop Addressable Devices Power Horns/Strobes Panel Interconnects Speaker 5737ARE 16 Solid.18 576ARE 1 Solid.18 5738ARE 1 Solid.6 5739ARE 1 Solid.6 Conductor color code. Chart on page. Non-Stock, Call for Availability. 7

FIRE ALARM SYSTEMS NON-PLENUM DATA ADDRESSABLE CABLE Multi-Conductor, Overall Shielded Mid Capacitance FPL ASTM Bare Copper Low Density Polyethylene Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Red PVC Jacket AWG & STRANDING NO. OF COND. NOM CAPACITANCE 57AREM 18 Solid.169 9.7 pf / ft 5736AREM 16 Solid.190 30.0 pf / ft 576AREM 1 Solid.38 3. pf / ft Conductor color code. Chart on page. Non-Stock, Call for Availability. 8

FIRE ALARM SYSTEMS PLENUM FPLP ASTM Bare Copper Premium LS PVC Insulation Twisted/Cabled Conductors Plenum Rated Red Poly-flex Jacket MULTI-CONDUCTOR, UNSHIELDED AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 5709ARE 5711ARE 5713ARE 571ARE 18 Solid 18 Solid 18 Solid 18 Solid 6 8.15.170.00.10 I/O SLC Loop Addressable Devices Power Horns/Strobes Panel Interconnects Speaker 570ARE 16 Solid.170 571ARE 16 Solid.0 5719Axx 1 Solid.06 573ARE 1 Solid.35 575ARE 1 Solid. 57ARE 1 Solid.303 Conductor color code. Chart on page. Non-Stock, Call for Availability. 9

FIRE ALARM SYSTEMS PLENUM MULTI-CONDUCTOR, OVERALL SHIELDED FPLP ASTM Bare Copper Premium LS PVC Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Plenum Rated Red Poly-flex Jacket AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 5717ARE 575ARE 576ARE 577ARE 18 Solid 18 Solid 18 Solid 16 Solid 6.15.156.15.170 I/O SLC Loop Addressable Devices Power Horns/Strobes Panel Interconnects Speaker 578ARE 16 Solid.06 577ARE 1 Solid.08 579ARE 1 Solid. 5750ARE 1 Solid.8 Conductor color code. Chart on page. Non-Stock, Call for Availability. 30

FIRE ALARM SYSTEMS PLENUM DATA ADDRESSABLE CABLE Multi-Conductor, Overall Shielded Mid Capacitance FPLP ASTM Bare Copper Mid Cap FPR Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Plenum Rated Red Poly-flex Jacket AWG & STRANDING NO. OF COND. NOM CAPACITANCE 5717AREM 18 Solid.19 30.1 pf / ft 577AREM 16 Solid.178 9.0 pf / ft 577AREM 1 Solid.0 9.9 pf / ft Conductor color code. Chart on page. Non-Stock, Call for Availability. 31

FIRE ALARM SYSTEMS WIRE DISTINGUISHER Circuit Tracer System Distinguisher approved Fire Alarm Cables with Color-Striped Jackets A color code stripe is embedded in the red cable jacket not an imprint! All cables are dual marked per the latest articles of the NEC Code. Examples: Horns & Strobes Speakers Data Communication (SLC) Annunciator Communication VDC Power Annunciator Power alternative color stripes available. Simplifies system servicing and expansion. 3

FIRE ALARM SYSTEMS NON-PLENUM FPLR ASTM Bare Copper Mid Cap PVC Insulation Twisted/Cabled Conductors Riser Rated Red Poly-flex Jacket with imbedded Stripe DISTINGUISHER Multi-Conductor, Unshielded Mid-Capacitance AWG & STRANDING NO. OF COND. NOM STRIPE COLORS 7518MRN 18 Solid.1 BL, BR, GR, PR, YL 7516MRN 16 Solid.170 BL, BR, GR, PR, YL 751MRN 1 Solid.10 BL, GY, OR, PR 751MRN 1 Solid.38 GY, OR DISTINGUISHER Multi-Conductor, Overall Shielded FPLR ASTM Bare Copper Mid Cap PVC Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Riser Rated Red Poly-flex Jacket with imbedded Stripe 7518SRN 18 Solid.17 BL, BR, YL 7516SRN 16 Solid.168 BL, BR, YL Conductor color code. Chart on page. Non-Stock, Call for Availability. 33

FIRE ALARM SYSTEMS PLENUM DISTINGUISHER Multi-Conductor, Unshielded Mid-Capacitance FPLP ASTM Bare Copper FPR Insulation Twisted/Cabled Conductors Plenum Rated Red Poly-flex Jacket with imbedded stripe AWG & STRANDING NO. OF COND. NOM STRIPE COLORS 7518MPN 18 Solid.150 GR 7516MPN 16 Solid.171 BL, GR, WH, YL 751MPN 1 Solid.06 BL, GY, PR, YL 751MPN 1 Solid.0 GY FPLP ASTM Bare Copper FPR Insulation Aluminum Polyester Foil Shield with drain Twisted/Cabled Conductors Plenum Rated Red Poly-flex Jacket with imbedded stripe 7518SPN 18 Solid.150 BL, BR, YL 7516SPN 16 Solid.169 BL, BR, GR, OR, PR, YL Conductor color code. Chart on page. Non-Stock, Call for Availability. 3

FIRE ALARM SYSTEMS PLENUM FPLP / CL3P ASTM Bare Copper Premium LS PVC Insulation Twisted/Cabled Conductors Overall Red LS Plenum Rated PVC Jacket SOUNDER BASE Multi-Pair, Unshielded Composite Cable AWG & STRANDING NO. OF COND. NOM Capacitance 75118MP 1 Solid.379 1 AWG 33.30 pf/ Ft 18 Solid 18 AWG 30.60 pf / Ft Ideal for hotels, apartments and multi-unit dwellings where there is a need for individual unit alarms combined with group, zone or general alarms. This cable simplifies the installation of multiple sounder base units by combining the individual unit signal cable with a group signal cable. The cable is designed with individually twisted pairs combined in an overall twisted pattern providing optimum electrical properties for Sounder Base installation. Conductor color code. Chart on page. 35

FIRE ALARM SYSTEMS NON-PLENUM CIRCUIT INTEGRITY (CI) Multi-Conductor, Overall Shielded FPLR-CI ASTM Bare Copper UL196 Twisted/Cabled Conductors Copper Shield with drain Flame Retardant, LS Zero Halogen Polyolefin Jacket AWG & STRANDING NO. OF COND. NOM CAPACITANCE 5160SCI 16 Solid.30 30.0 pf / ft 510SCI 1 Solid.30 36.0 pf / ft 510SCI 1 Solid.380 0.0 pf / ft TYPE CI: Among the many features of this hour fire rated cable is the fact that it does not need to be installed in conduit. This product passed the UL196 fire test and fire hose test without being installed in conduit and therefore was given the designation of CI (Fire Alarm Circuit Integrity Cable) as defined in Article 760 of the National Electrical Code. Whether installing in conduit or not, this feature can provide considerable cost savings over other hour rated installations that typically require fire-rated walls and strict conduit support spacing standards. Meets survivability requirements and NFAC. Both conductors are black with words 1. Black &. Red. 36

FIRE ALARM SYSTEMS NON-PLENUM FPL ASTM Bare Copper High Grade PVC Insulation Red, Parallel Conductors Unjacketed PARALLEL ZIP WIRE, UNSHIELDED AWG & STRANDING NO. OF COND. NOM CONDUCTOR COLORS 5700ARE 18 Solid.110 x.13 RE 5701ARE 16 Solid.115 x.30 RE 570ARE 1 Solid.16 x.5 RE FPLP PLENUM ASTM Bare Copper Premium LS PVC Insulation Non-Twisted Conductors Plenum Rated Red Poly-flex Jacket MULTI-CONDUCTOR, UNSHIELDED Non-Twisted Color Coded Conductors Overall Jacket AWG & STRANDING NO. OF COND. NOM ALTERNATE JACKET COLORS 5758ARE 16 Solid.173 5755ARE 1 Solid.06 WH With tracer and stripe. Conductor color code. Chart on page. Non-Stock, Call for Availability. 37

FIRE ALARM SYSTEMS CORRA/CLAD MC CABLE CORRA/CLAD Corrugated Aluminum Sheath Separator Tape Fillers Type TFN, TFFN or THHN Insulation Copper Conductor UL LISTED MC CABLE Corra/Clad is constructed in accordance with Underwriters Laboratories, Inc., standard for Metal-Clad Cable (UL 1569). Corra/Clad meets or exceeds interlocked MC cable. Corra/Clad can be used everywhere interlocked MC cable can be used plus additional places MC cable can t be used. HEALTH CARE FACILITIES Corra/Clad s outer jacket is an approved grounding means of a listed cable assembly and employs a continuous, gas/vapor tight metal sheath. Corra/Clad is permitted for use in hospitals and health care facilities, including all patient care areas per Article 517-13(a) and (b). A properly sized ground must also be a part of the listed assembly. When Corra/Clad is ordered with a separate ground the green ground wire is marked ISOLATED GROUND COND. For Health Care Facility wiring Corra/Clad has quickly become the preferred method of wiring for these facilities. (Consult local authorities for special inclusions or restrictions.) FIRE RESISTANT Due to its solid fill construction, smoke can not chimney through the continuous sheath. This lack of oxygen makes Corra/Clad and Metal Clad squared fire resistant. Corra/Clad may be used in a plenum area per Article 300-(b) of the NEC. FIRE/CLAD MC CABLE Our Fire/Clad MC Cable is Corra/Clad cable with a red ink coloring on the aluminum sheath to designate the cable as part of a fire alarm system. Fire/Clad and Corra/Clad is dual rated as MC Cable and as FPL Cable. 38

FIRE ALARM SYSTEMS SUITABLE FOR PLENUM MC / FPL ASTM Bare Copper Type TFN/TFFN & THHN PVC and Nylon Insulation Cabled Conductors Aluminum Sheath Water and Fire Resistant CORRA/CLAD MC CABLE Multi-Conductor, Unshielded AWG & STRANDING NO. OF COND. NOM CONDUCTOR COLORS 5180MC 18 Solid.335 BK, RE 5180MC 18 Solid.370 BK, RE, BL, OR 5160MC 16 Solid.355 BK, RE 5160MC 16 Solid.395 BK, RE, BL, OR 510MC 1 Solid.380 BK, WH 510MC 1 Solid.5 BK, WH, RE, BL 510MC 1 Solid.05 BK, WH 510MC 1 Solid.60 BK, WH, RE, BL Operating Temperature 90 c / Max Voltage 600v Suitable for plenum per NEC Article 300-(b) Protective metal sheath marked with red color stripe (other colors available upon request) Conductor color code 7. Chart on page. Non-Stock, Call for Availability. 39

FIRE ALARM SYSTEMS SUITABLE FOR PLENUM MC / FPL ASTM Solid Bare Copper Type TFN/TFFN & THHN PVC and Nylon Insulation Aluminum Sheath Water and Fire Resistant CORRA/CLAD MC CABLE Multi-Paired Unshielded Composite Cables 5MC01 5MC0 5MC03S 5MC301 5MC01 PAIR NO. 1 1 1 1 1 3 1 3 AWG & STRANDING 1 Solid 1 Solid 18 Solid SHIELDED 1 Solid 16 Solid 1 Solid 16 Solid 1 Solid 1 Solid 16 Solid 1 Solid 1 Solid 1 Solid USE Speaker Strobe EIA-85 v DC SLC MidCap v DC SLC MidCap Strobe v DC SLC MidCap Strobe Speaker v DC CONDUCTOR COLORS Re / Bk Yw / Bl Re / Bk Or / Bl Re / Gr Pk / Vi Re / Gr Yw / Bl Pk / Vi Re / Gr Yw / Bl Re / Bk Pk / Vi Operating Temperature 90 c / Max Voltage 600v Suitable for plenum per NEC Article 300-(b), 33 & 760 Protective metal sheath marked with red color stripe (other colors available upon request) 0

COAXIAL CABLE Paige coaxial cables are designed for sophisticated security surveillance, and today s high tech multi-media distribution systems that require wide bandwidth transmissions and low loss signals. They carry the following listings in common: 75 C Temperature rated UL Listed and Canadian UL Listed Meets NEC Article 80 UL Listings for cables in this section: CATV / MATV CCTV Non-Plenum Plenum Non-Plenum Plenum RG59 & RG6 CATV / CM CATVP / CMP CM CMP RG11 CATV / CL3 CATV / CL3P CL3 CL3P For additional information on NEC / UL see p. 88-91 in the technical section. Additional features of cables in this section: Sunlight resistant jackets Solid bare copper cores and 95% bare copper braids for reduced dc resistance and improved CCTV low frequency transmissions Foil and braid shield combined for CATV transmissions to protect both high and low frequencies from ambient noise 1

COAXIAL CABLES NON-PLENUM CATV / CL3 or CM ASTM Bare Copper or Copper Clad Steel Low Density Polyethylene Insulation Overall Black Sunlight Resistant PVC Jacket RG59 5818ABL AWG & STRANDING SHIELD Solid CCS 0% Al Braid +100% Al Foil NOM. CATV POSSIBLE USE & APPLICATIONS RG6 581ABL 18 Solid BC 65% Al Braid + 100% Al Foil.75 CATV 5810AWH 18 Solid BC 60% Al Braid +100% Al Foil 0% Al Braid +100% Al Foil.300 RG11 581ABL 1 Solid BC 65% Al Braid + 100% Al Foil.05 CATV For Outdoor Versions see Page 71. Non-Stock, Call for Availability. 3

COAXIAL CABLES NON-PLENUM CL3 or CM ASTM Bare Copper Foamed Polyethylene Insulation Bare Copper Shield Overall Black Sunlight Resistant PVC Jacket RG59 AWG & STRANDING SHIELD NOM POSSIBLE USE & APPLICATIONS 5800ABLS 0 Solid BC 95% BC Braid. CCTV 5806ABL 0 Solid BC 18/ 7 x 6 (Siamese) 95% BC Braid. x.60 CCTV & POWER RG6 580ABLS 18 Solid BC 95% BC Braid.70 CCTV 58ABK 18 Solid BC 16/ 19 x 9 (Siamese) 95% BC Braid.60 CCTV & POWER RG11 5807ABL 1 Solid BC 95% BC BRAID.05 CCTV For Outdoor Versions see Page 71.

COAXIAL CABLES NON-PLENUM CATV / CM Tinned Copper Foamed Polyethylene Insulation Aluminum Polyester Foil Shield with drain Individually Jacketed Mini Coaxial Cables Overall Black Sunlight Resistant PVC Jacket RGB COMPOSITE VIDEO (RGBHV) 58ABK AWG & STRANDING SHIELD NOM INTERNAL JACKET COLORS 6 7 x 3 TC 93% TC Braid.05 Re/GN/Bl/BK/YW Each coax is individually jacketed with color coded PVC. The coax cables are cabled together and shielded with an overall aluminum / polyester foil tape. To complete construction an overall black PVC jacket is applied. Non-Stock, Call for Availability. 5

COAXIAL CABLES PLENUM CATVP / CMP or CL3P ASTM Bare Copper Fluoropolymer Insulation Plenum Rated White Poly-flex Jacket RG6 AWG & STRANDING SHIELD NOM POSSIBLE USE & APPLICATIONS 5813AWH 18 Solid BC 90% Al Braid + 100% Al Foil.50 CATV MATV 5811AWH 18 Solid BC 75% Al Braid +100% Al Foil 55% Al Braid +100% Al Foil.6 RG11 5815AWH 1 Solid BC 65% Al Braid + 100% Al Foil.36 CATV MATV 6

COAXIAL CABLES PLENUM CL3P / CMP ASTM Bare Copper Fluoropolymer Insulation Plenum Rated White Poly-flex Jacket RG59, CCTV AWG & STRANDING SHIELD NOM POSSIBLE USE & APPLICATIONS 5801Axx 0 Solid BC 95% BC Braid.190 CCTV & POWER 580AWH 0 Solid BC 18/ 7x 6 (Siamese) 95% BC Braid.19 x.360 RG6, CCTV 5803Axx 18 Solid BC 95% BC Braid.76 CCTV & POWER 583AWH 18 Solid BC 16/ 19 x 9 (Siamese) 95% BC Braid.75 x.90 Non-Stock, Call for Availability. 7

COAXIAL CABLES NON-PLENUM RG59 CCTV PATCH CABLE BNC Male to Male CM ASTM Bare Copper Foamed Polyethylene Insulation Bare Copper Shield Overall Black Sunlight Resistant PVC Jacket Terminated each end with crimp on BNC 75 ohm connectors AWG & STRANDING SHIELD NOM LENGTH 391310 0 SOLID BC 95% BC Braid. 1 391315 0 SOLID BC 95% BC Braid. 1.5 391330 0 SOLID BC 95% BC Braid. 3 391360 0 SOLID BC 95% BC Braid. 6 391399 0 SOLID BC 95% BC Braid. 10 8

LAN, DATA & NETWORK SOLUTIONS Paige LAN, Data & Network cables are designed for top network performance and reliability. They are available in a variety of colors for fast cable identification. They carry the following listings in common: 75 C Temperature rated 300 volt UL Listed Meets NEC Article 800 ETL Verified to applicable TIA/EIA standards NEC / UL Listings for cables in this section: Gauge Sizes Non-plenum Non-plenum Riser Plenum AWG AWG CM / MP CMR CMP / MPP For additional information on NEC / UL see p. 88-91 in the technical section. Additional features of cables in this section: Staggered twisted pairs for reduced cross-talk ASTM bare copper conductors Premium grade PVC for improved strength and flexibility (CAT 3) DataCap low capacitance insulators for improved signal strength (CAT 5-CAT 6) When shielded, corrosion resistant tinned copper drain wires are used Telco standard color-coded conductors 9

LAN, DATA & NETWORK SOLUTIONS CONDUCTOR COLOR CHART Color Code 6 Pair # 1st/nd 1 White/Blue-Blue White/Orange-Orange 3 White/Green-Green White/Brown-Brown Color Code 9 Pair # 1st Conductor 1 White / Blue White / Orange 3 White / Green White / Brown 5 White / Slate 6 Red / Blue 7 Red / Orange 8 Red / Green 9 Red / Brown 10 Red / Slate 11 Black / Blue 1 Black / Orange 13 Black / Green 1 Black / Brown 15 Black / Slate 16 Yellow / Blue 17 Yellow / Orange 18 Yellow / Green 19 Yellow / Brown 0 Yellow / Slate 1 Violet / Blue Violet / Orange 3 Violet / Green Violet / Brown 5 Violet / Slate nd Conductor Blue / White Orange / White Green / White Brown / White Slate / White Blue / Red Orange / Red Green / Red Brown / Red Slate / Red Blue / Black Orange / Black Green / Black Brown / Black Slate / Black Blue / Yellow Orange / Yellow Green / Yellow Brown / Yellow Slate / Yellow Blue / Violet Orange / Violet Green / Violet Brown / Violet Slate / Violet Conductor Colors 50 BE BK BL BR GN Beige Black Blue Brown Green GR OR PK PR Gray Orange Pink Purple RE VI WH YW Red Violet White Yellow

LAN, DATA & NETWORK SOLUTIONS NON-PLENUM CMR ASTM Bare Copper High Grade PVC Insulation Paired Conductors Riser Rated Gray PVC Jacket CATEGORY 3 Unshielded Twisted Pairs (UTP) AWG & STRANDING NO. OF PAIRS NOM POSSIBLE USE & APPLICATIONS 71051 71051 Solid Solid.130.15 Voice or Data UTP Video 710518 Solid 5.35 710513 Solid 50.50 710519 Solid 100.650 71050 Solid.150 710503 Solid 3.160 Conductor color code 9. Chart on page 50. Non-Stock, Call for Availability. 51

LAN, DATA & NETWORK SOLUTIONS PLENUM CMP ASTM Bare Copper High Grade PVC Insulation Paired Conductors Plenum Rated White Poly-flex Jacket CATEGORY 3 Unshielded Twisted Pairs (UTP) AWG & STRANDING NO. OF PAIRS NOM POSSIBLE USE & APPLICATIONS 710515 710516 Solid Solid.130.155 Voice or Data UTP Video 710517 Solid 5.330 7105 Solid 50.60 71051 Solid 100.60 710510 Solid.155 71050 Solid 5.365 Conductor color code 9. Chart on page 50. Non-Stock, Call for Availability. 5

LAN, DATA & NETWORK SOLUTIONS NON-PLENUM CMR ASTM Bare Copper DataCap FE Insulation Paired Conductors Riser Rated Misc. Colors PVC Jacket CATEGORY 5E Unshielded Twisted Pairs (UTP) AWG & STRANDING NO. OF PAIRS NOM POSSIBLE USE & APPLICATIONS 71058E Solid.185 Voice or Data UTP Video 71055E* Solid 350 MHZ.185 Conductor color code 9. *Conductor color code 6. Chart on page 50. For Outdoor versions see p.7. 53

LAN, DATA & NETWORK SOLUTIONS PLENUM CMP / MPP ASTM Bare Copper DataCap FP Insulation Paired Conductors Plenum Rated Misc. Colors PVC Jacket CATEGORY 5E Unshielded Twisted Pairs (UTP) AWG & STRANDING NO. OF PAIRS NOM POSSIBLE USE & APPLICATIONS 710536E Solid.185 Voice or Data UTP Video 710556E* Solid 350 MHZ.185 Conductor color code 9. *Conductor color code 6. Chart on page 50. 5

LAN, DATA & NETWORK SOLUTIONS PLENUM CMP ASTM Bare Copper LoCap FPR Insulation Paired Conductors Plenum Rated Gray Poly-flex Jacket CATEGORY 5, POWERSUM Unshielded Twisted Pairs (UTP) 710550PL AWG & STRANDING Conductor color code 9. Chart on page 50. For Outdoor version see page 7. NO. OF PAIRS NOM Solid 5.00 Network Trunk POSSIBLE USE & APPLICATIONS 55

LAN, DATA & NETWORK SOLUTIONS NON-PLENUM CM ASTM Bare Copper High Density Polyethylene Insulation Paired Conductors PVC Jacket CATEGORY 5E, PATCH CABLES Unshielded, Unbooted 7105303 7105305 7105307 7105310 7105315 710535 7105350 Modular Plug AWG & STRANDING 7 x 3 7 x 3 7 x 3 7 x 3 7 x 3 7 x 3 7 x 3 NO. OF PAIRS Housing: 3 Clear, Polycarbonate, UL9V09 RJ-5 Contact: 3 High Strength Copper Alloy 3 Gold Plating Over 100 Micro Inch Nickel Gold Plating: 3 50 Micro Inch/1,7 Micron Min. of Contact Number Of Contacts: 3 Eight NOM.00.00.00.00.00.00.00 LENGTH 3 5 7 10 15 5 50 Available jacket colors: BK, BL, GN, OR, PR, PK, RE, WH, YW Conductor color code 9. Chart on page 50. 56

LAN, DATA & NETWORK SOLUTIONS NON-PLENUM CATEGORY 5E, PATCH CABLES Unshielded, Booted CM ASTM Bare Copper High Density Polyethylene Insulation Paired Conductors Booted Design PVC Jacket 710503 710505 710507 710510 710515 71055 710550 Modular Plug AWG & STRANDING 7 x 3 7 x 3 7 x 3 7 x 3 7 x 3 7 x 3 7 x 3 NO. OF PAIRS Housing: 3 Clear, Polycarbonate, UL9V09 RJ-5 Contact: 3 High Strength Copper Alloy 3 Gold Plating Over 100 Micro Inch Nickel Gold Plating: 3 50 Micro Inch/1,7 Micron Min. of Contact Number Of Contacts: 3 Eight NOM.00.00.00.00.00.00.00 LENGTH 3 5 7 10 15 5 50 Available jacket colors: BK, BL, GN, OR, PR, PK, RE, WH, YW Conductor color code 9. Chart on page 50. 57

LAN, DATA & NETWORK SOLUTIONS NON-PLENUM TIA/EIA CERTIFIED CATEGORY 6 Unshielded Twisted Pairs UTP CMR ASTM Bare Copper DataCap FE Insulation Paired Conductors X-Beam Spacer Riser Rated LS PVC Jacket 71068 AWG & STRANDING NO. OF PAIRS NOM POSSIBLE USE & APPLICATIONS 3 SOLID.0 Voice or Data UTP Video PLENUM CMP DataCap FP Insulation 710636 3 SOLID.0 Voice or Data UTP Video These cables are specially designed to exceed the TIA/EIA 568 B.-1 standard for next generation category 6 cabling. They are constructed of four precision balanced pairs, held in correct alignment by means of a unique central X-Beam spacer. For systems operating from 10Mb/s to 1000Mb/s, these cables provide the necessary headroom and bandwidth to support the most robust applications. Conductor color code 9. Chart on page 50. Non-Stock, Call for Availability. 58

THERMOSTAT CABLE Paige thermostat cables can be used for low voltage applications such as thermostat controls or HVAC equipment. They are available with a brown jacket for easy cable identification. They carry the following listings in common: 75 C Temperature rated 300 volt UL Listed and Canadian UL Listed Meet NEC Article 75 NEC / UL Listings for cables in this section: Gauge Sizes 18 AWG Plenum CMP For additional information on NEC / UL see p. 88-91 in the technical section. Additional features of cables in this section: ASTM bare copper conductors Premium grade PVC for improved strength and flexibility Color-coded conductors 59

THERMOSTAT CABLE CONDUCTOR COLOR CHART Color Code 5 Conductor Colors 1 3 5 6 7 8 9 10 11 1 13 1 15 16 17 18 19 0 Red White Blue Green Brown Black Yellow Orange Purple Gray Tan Pink Light Blue White w/blue Stripe White w/black Stripe White w/brown Stripe White w/red Stripe Red w/white Stripe Blue w/white Stripe Green w/white Stripe BE BK BL BR GN GR Beige Black Blue Brown Green OR PK PR RE Gray Orange Pink Purple VI WH YW Red Violet White Yellow 60

THERMOSTAT CABLE PLENUM CMP ASTM Bare Copper Premium LS PVC Insulation Cabled Conductors Plenum Rated Brown Poly-flex Jacket Unshielded AWG & STRANDING NO. OF COND. NOM POSSIBLE USE & APPLICATIONS 51805CTP 18 SOLID 5.177 WH 51806CTP 18 SOLID 6.19 WH 51808CTP 18 SOLID 8.5 WH Conductor color code 5. Chart on page 60. Non-Stock, Call for Availability. 61

OUTDOOR APPLICATIONS Paige has put together a complete line of sunlight resistant outdoor cables for aerial or burial applications. Because Paige is #1 in the irrigation control, turf management and landscape markets, we have the expertise to hook you up with just the right product for your outdoor need. In this section you ll find a small sample of what we can do to help you, whether you re flying it, burying it, laying it on a roof, or pulling it through a buried conduit. For example, we can set you up with cables for all of the following applications: Access control Closed circuit cameras CATV distribution FA Panel Communications FA SLC loops Intercom s & paging Perimeter Security Power cable Speakers Sprinkler control And many more. Some of the cable features you ll find in this section: Tough, proven jackets and insulation s 30, 300 and 600 volt rated cables 75, 90 and 105 C temperature ratings ASTM bare or tinned copper Dry tape water-blocking constructions Wide range of UL listings to cover every need: TC / FPL / CM / CL3 / DB 63

OUTDOOR APPLICATIONS CONDUCTOR COLOR CHART Color Code 1 1 Black Red 3 White Green 5 Brown 6 Blue 7 Orange 8 Yellow 9 Purple 10 Gray 11 Pink 1 Tan 13 White / Black 1 White / Red 15 White / Green 16 White / Orange 17 White / Blue 18 White / Brown 19 White / Yellow 0 White / Purple 1 White / Gray Black / Red 3 Black / Green Black / Yellow 5 Black / Blue 6 Black / Brown 7 Black / Orange 8 Black / Gray 9 Black / Purple 30 Red / Green Color Code 3 1 Black White 3 Red Green 5 Brown 6 Blue 7 Orange 8 Yellow 9 Purple 10 Gray 11 Pink 1 Tan Color Code 5 1 Red White 3 Blue Green 5 Brown 6 Black 7 Yellow 8 Orange 9 Purple 10 Gray 11 Tan 1 Pink 13 Light Blue 1 White w/blue Stripe 15 White w/black Stripe 16 White w/brown Stripe 17 White w/red Stripe 18 Red w/white Stripe 19 Blue w/white Stripe 0 Green w/white Stripe 6

OUTDOOR APPLICATIONS CONDUCTOR COLOR CHART Color Code 9 Pair # 1st Conductor 1 White / Blue White / Orange 3 White / Green White / Brown 5 White / Slate 6 Red / Blue 7 Red / Orange 8 Red / Green 9 Red / Brown 10 Red / Slate 11 Black / Blue 1 Black / Orange 13 Black / Green 1 Black / Brown 15 Black / Slate 16 Yellow / Blue 17 Yellow / Orange 18 Yellow / Green 19 Yellow / Brown 0 Yellow / Slate 1 Violet / Blue Violet / Orange 3 Violet / Green Violet / Brown 5 Violet / Slate nd Conductor Blue / White Orange / White Green / White Brown / White Slate / White Blue / Red Orange / Red Green / Red Brown / Red Slate / Red Blue / Black Orange / Black Green / Black Brown / Black Slate / Black Blue / Yellow Orange / Yellow Green / Yellow Brown / Yellow Slate / Yellow Blue / Violet Orange / Violet Green / Violet Brown / Violet Slate / Violet Conductor Colors BE BK BL BR GN GR Beige Black Blue Brown Green Gray PK PR RE VI WH YW Pink Purple Red Violet White Yellow OR Orange 65

OUTDOOR APPLICATIONS ASTM Bare Copper High Grade PVC Insulation Cabled Conductors Black Sunlight Resistant PE Jacket with Nylon Rip Cord AERIAL or DIRECT BURIAL Multi-Conductor, Unshielded (For Outdoor Use Only, Not Indoors) AWG & STRANDING NO. OF COND. NOM UL 180010 18 SOLID.195 DB 180019 18 SOLID 3.05 DB 18000 18 SOLID.5 DB 180030 18 SOLID 5.5 DB 18000 18 SOLID 6.65 DB 180050 18 SOLID 7.80 DB 180060 18 SOLID 8.90 DB 180070 18 SOLID 9.310 DB 180080 18 SOLID 10.35 DB 180090 18 SOLID 1.30 DB 180091 18 SOLID 13.355 DB 30 volts Conductor color code 5. Chart on page 6. 66

OUTDOOR APPLICATIONS ASTM Bare Copper PVC Insulation Water Blocking Twisted/Cabled Conductors Black Sunlight Resistant PVC Jacket Indoor / Outdoor UL Listed AERIAL or DIRECT BURIAL Multi-Conductor, Unshielded, Waterblocked AWG & STRANDING NO. OF COND. NOM UL 5180WDB 18 7 x 6.60 CM / FPL / TC / DB 5160WDB 16 19 x 9.80 CM / FPL / TC / DB 510WDB * 1 19 x 6.310 CL3 / FPL / TC / DB 510WDB * 1 19 x 5.35 CL3 / FPL / TC / DB Conductor color code 1. * Conductor color code 3 Chart on page 6. 67

OUTDOOR APPLICATIONS ASTM Bare Copper PVC Insulation Aluminum Polyester Foil Shield with drain Water Blocking Twisted/Cabled Conductors Black Sunlight Resistant PVC Jacket Indoor / Outdoor UL Listed AERIAL or DIRECT BURIAL Multi-Conductor, Overall Shielded, Waterblocked AWG & STRANDING NO. OF COND. NOM UL 5180SDB 18 7 x 6.65 CM / FPL / TC / DB 5180SDB 18 7 x 6.98 CM / FPL / TC / DB 51806SDB 18 7 x 6 6.333 CM / FPL / TC / DB 5160SDB 16 19 x 9.8 CM / FPL / TC / DB 510SDB 1 19 x 6.31 CM / FPL / TC / DB Conductor color code 1. Chart on page 6. 68

OUTDOOR APPLICATIONS ASTM Bare or Tinned Copper Wet Location Insulation Aluminum Polyester Foil Shield with drain Paired Conductors Black Sunlight Resistant Jacket AERIAL or DIRECT BURIAL Multi-Pair, Overall Shielded AWG & STRANDING NO. OF PAIRS NOM UL 700190 SOLID, FILLED 5.50 DB 5160PSTC* 16 7 x TC.377 TC *Each pair is Black / White and numbered 1 or. Conductor color code 9. Chart on page 65. 69

OUTDOOR APPLICATIONS CM / CL3 ASTM Tinned Copper PVC Insulation Aluminum Polyester Foil Shields with individual drains Water Blocking Twisted/Cabled Conductors Gray Sunlight Resistant PVC Jacket AERIAL or CONDUIT BURIAL Multi-Pair, Individually Shielded, Waterblocked AWG & STRANDING NO. OF PAIRS NOM UL 501SWB SOLID TC 1.150 50SWB SOLID TC (1 Pr Shielded) (1 Pr Unshielded).65 506SWB* SOLID TC 3 (1 Pr Shielded) ( Pr Unshielded).55 515PSWB** SOLID TC 15.50 55PSWB** SOLID TC 5.615 5180SDB 18 7 x 6 (1 Pr, SHIELDED).305 DB * Conductor Color Code 3 ** Conductor Color Code 9 Conductor color code 1. Chart on page 6-65. Non-Stock, Call for Availability. 70

OUTDOOR APPLICATIONS ASTM Copper Clad Steel Foam PE Insulation Aluminum Braid plus Aluminum Foil Shield Black Sunlight Resistant Jacket AERIAL or DIRECT BURIAL Coaxial CATV, RG6 & RG11 AWG & STRANDING SHIELD NOM UL 581FDB 18 Solid CCS Flooded 60% Al Braid + 100% Al Foil.70 RG6 DB 581DB 1 Solid CCS Flooded 65% Al Braid + 100% Al Foil.00 RG11 DB ASTM Bare Copper Foam PE Insulation Bare Copper Braid Black Sunlight Resistant Jacket AERIAL or DIRECT BURIAL Coaxial CCTV, RG6 AWG & STRANDING SHIELD NOM UL 580ABL 18 SOLID BC 95% BC Braid.7 DB 586ABL 18 SOLID BC + 16 AWG HIGH STRENGTH C OOPER COATED SteeL Messenger 95% BC Braid.70 x.00 DB Non-Stock, Call for Availability. 71

OUTDOOR APPLICATIONS AERIAL or DIRECT BURIAL Category 5e, Unshielded Twisted Pairs (UTP) ASTM Bare Copper MIL-C-60A Water Polyolefin Insulation Penetration Requirement Paired Conductors Fully Flooded, Waterproof Black Sunlight and Water Resistant PE Jacket 71058EDB AWG & STRANDING NO. OF PAIRS NOM SOLID.30 DB UL ASTM Bare Copper Polyolefin Insulation Corrugated Aluminum / Polymer Tape Shield Paired Conductors Black Sunlight & Water Resistant PE Jacket AERIAL or DIRECT BURIAL Category 5 Powersum Overall Shielded Twisted Pairs (STP) 710550DB AWG & STRANDING NO. OF PAIRS NOM SOLID, Filled 5.630 DB UL Conductor color code 9. Chart on page 65. 7

OUTDOOR APPLICATIONS AERIAL MESSENGER 5MES5 AWG & STRANDING 1/ Galvanized Steel No. OF COND. NOM UL N/A N/A N/A 73

FIBER OPTIC CABLE Fiber optic cables represent the state of the art in high speed, secure communications. For LANs, WANs, long distance CCTV and integrated security and fire products, fiber optics are the cable of choice. Paige Electric has been a leading supplier of Fiber Optic Products for decades. Using our team of highly trained personnel, Paige can help you choose the most cost effective fiber optic solution. We offer products for indoor / outdoor / aerial / burial / chemical or zero halogen installations. The following pages provide a brief primer on fiber optic cables followed by a sample of some of our most commonly used constructions. 75

FIBER OPTIC CABLE BASIC FACTS ADVANTAGES secure transmission RFI/EMI noise immunity Lightning and high voltage interference immunity total electrical isolation wide range of operating temperatures low attenuation high bandwidth small diameter and light weight easy installation custom configurations excellent customer support Optical fiber consists of three basic structures: the core, cladding and coating. Transmission occurs through the glass or plastic core. Light waves are transmitted down the length of the fiber by way of the interaction between the core and the cladding. The cladding provides a lower refractive index at the core interface which causes reflection of light exclusively within the core. Multi-layers of plastic are applied to provide fiber protection. The coating on the glass fibers enables them to be handled and processed into cable form. There are two types of fiber relative to the paths that the light rays, or modes, travel within the fiber core: Fiber Structure Cross Section of Optical Fiber Core Cladding Coating Multimode and single mode. Multimode fiber cores are classified as either step or graded index, depending on the refractive index. Step index multimode fiber has a uniform core and an abrupt change in refractive index at the core/cladding interface. In graded index multimode fiber the core contains many layers of glass, each with a lower index of refraction. 76

FIBER OPTIC CABLE BASIC FACTS ADVANTAGES The light modes taking longer paths travel faster than the modes taking the straighter paths. This allows for all the light modes to be received at the same time. The main characteristic of single modefiber is that only a single light light ray, or mode, is transmitted down the core. Since the light pulses do not overlap, distortion is eliminated. Graded index fibers are commercially available with core diameter/ cladding diameters of 50/15, 6.5/15, and 100/10 microns. Single mode fibers have a smaller core, typically 8.5µm, but also have 15µm cladding diameter. Coatings are available from 50 microns to 900 microns. Step Index (Multimode) Core Source Cladding Graded Index (Multimode) Single Mode (Monomode) A Graphic Representation of How Light Rays Travel in Three Fiber Types 77

FIBER OPTIC CABLE GLOSSARY OF TERMS Attenuation Loss of signal power between points. In optical cables, attenuation is a ratio of input power vs. output power, measured in decibels per unit length, usually db/km. Backbone A high-speed transmission system used to connect relatively distant points. Backbone networks can be used to join autonomous networks within buildings or between different buildings. Bandwidth The information carrying capacity of a fiber. The bandwidth for a given wavelength is the lowest frequency at which optical power has decreased by 3 db and is expressed in MHz-km. Bend Radius The radius of curvature that an optical fiber cable can bend without causing harmful effects on the optical or mechanical performance of the cable. C h r o m a t i c Dispersion Different wavelengths travel along an optical medium at different speeds. Wavelengths reach the end of the medium at different times, causing the light pulse to spread. This chromatic dispersion is expressed in picoseconds (of dispersion) per kilometer (of length) per nanometer (of source bandwidth). It is the sum of material and waveguide dispersion. Cladding The layer of material, usually glass, that immediately surrounds the fiber core. The cladding is usually coated with another material to provide protection when handling. Core The central part of the glass construction through which light is transmitted. Cut-off Wavelength The wavelength at which a single-mode fiber transmits a single mode of light. Dielectric Non-metallic. All-dielectric designs are inherently non-conductive; all-dielectric cables contain no metal and are lightning resistant. Graded Index A core refractive index profile that varies with the radius of the core. Loss Budget The total acceptable loss for a given system from transmitter to receiver. Includes cables, 78

FIBER OPTIC CABLE GLOSSARY OF TERMS splices and connectors. Material Dispersion Pulse dispersion due to the variations in a material s refractive index as a function of wavelength. Microbending Minute but sever bends in fiber that result in light displacement and increased loss. Most microbending can be avoided by the correct selection of materials and proper cabling, handling, and installation techniques. Mode A path of light through a fiber. Mode Field Diameter In single-mode fiber, the region in which light propagates is larger than the glass core diameter. This mode field diameter is a measured value and often listed as a requirement with core diameter in fiber specifications. Numerical Aperture In fiber optics, the sine of half the angle over which a fiber can accept light, it is a function of the relationship between the refractive index of the core and that of the cladding. Optical Time Domain Reflectometer (DTDR) An instrument that measures transmission characteristics of fiber by sending a pulse of light down the fiber and measuring the light scattered across the length and reflected back from the end as a function of time. Used to measure attenuation, point discontinuities and fiber length, as well as to find breaks. Refractive Index The ratio of the speed of light in a vacuum to the speed of light in a material. Also called Index of Refraction. Step Index A refractive index profile characterized by a uniform refractive index within the core and a sharp decrease at the core-cladding interface. Waveguide Dispersion Dispersion caused by the fact that light travels at different speeds in the core and cladding of single-mode fibers. Zero Dispersion Wavelength In single-mode fibers, the wavelength at which the effects of chromatic dispersion and waveguide dispersion are lowest, thus providing the greatest information carrying capacity. 79

FIBER OPTIC CABLE PLENUM OFNP 6.5 / 15 Micron Indoor Premise Fiber Multimode Tight Buffered Fiber Aramid Yarns Outer Jacket Indoor Plenum Rated No. of Fibers DESCRIPTION Nom 7DP0068 6.5 Circular Premise 0.190 7UP0068 6.5 Circular Premise 0.190 7CP0066 6 6.5 Circular Premise 0.170 7CP01655 1 6.5 Circular Premise 0.0 Temperature Range: Operating temperature of F to + 158 F Optical Specs ( 850nm / 1300nm ): Max Attenuation Loss: 3.5 / 1. db/km Type. Attenuation Loss: 3.0 / 1.0 db/km Bandwidth (MHz/km): 160 / 500 ( fiber ) 00 / 600(, 6, 1 fiber ) 80

FIBER OPTIC CABLE NON-PLENUM Optical Fiber(s) Water Blocking Gel OFNR 6.5 / 15 Micron Indoor / Outdoor Riser Rated Fiber Multimode PVC Jacket Water Blocking Strength Member Buffer Tube Ripcord Indoor / Outdoor Riser Rated No. of Fibers DESCRIPTION Nom 7LV0061 6.5 Gel Filled Loose Tube (Single Tube) 0.300 7LV006661 6 6.5 Gel Filled Loose Tube (Single Tube) 0.300 7LV016C1 1 6.5 Gel Filled Loose Tube (Single Tube) 0.300 7LV06C5 6.5 Gel Filled Loose Tube ( Tubes w/1 fibers ea) 0.530 Temperature Range: Operating temperature of 0 F to + 158 F Optical Specs ( 850nm / 1300nm ): Max Attenuation Loss: 3.5 / 1. db/km Bandwidth (MHz/km): 00 / 600 81

FIBER OPTIC CABLE PLENUM OFNP 6.5 / 15 Micron Indoor / Outdoor Plenum Rated Fiber Multimode PVC Buffered Fiber Water, Fungus and UV Resistant Polymer Jacket Water Blocked Strength Member Indoor / Outdoor Plenum Rated No. of Fibers DESCRIPTION Nom 7KP0068 6.5 Tight Buffered 0.190 7KP0068 6.5 Tight Buffered 0.190 7KP006655 6 6.5 Tight Buffered 0.0 7KP01666 1 6.5 Tight Buffered 0.60 Temperature Range: Operating temperature of 0 F to + 158 F Optical Specs ( 850nm / 1300nm ): Max Attenuation Loss: 3.5 / 1. db/km Type. Attenuation Loss: 3.0 / 1.0 db/km Bandwidth (MHz/km): 00 / 600 8

FIBER OPTIC CABLE Water Blocking Core Ripcord Jacket Non- Hygroscopic Core Wrap Polyethylene Inner Jacket Outdoor Aerial or Burial Fiber 6.5 / 15 Micron Multimode PVC Jacket FRP Dielectric Central Member Torque Balanced Aramid Yarns Gel Filled Loose Buffer Tube Self-Supporting Aerial (ADSS) No. of Fibers DESCRIPTION Nom 7AE0066C5 6 6.5 All Dielectric 0.80 7AE016C5 1 6.5 All Dielectric 0.80 83

FIBER OPTIC CABLE OUTDOOR AERIAL SUPPORT ACCESSORIES ADSS Hardware & Accessories 7ADEMS8 Description ADSS Mini-Deadend 7AMB8 7ATG755 7AVD656 ADSS Mini-Bracket (for spans up to 00 ) ADSS Tangent / Trunion (for spans over 00 ) ADSS Vibration Damper 7AGW6956 ADSS Tower Guide Clamp 8