Pipeline Personnel Qualification. ASME B31Q Update. Presented by: Mike Gruenberg Southwest Gas Corporation

Similar documents
Australian/New Zealand Standard

AS/NZS :2008

INTERNATIONAL STANDARD

Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen

rpsa FIRE PROTECTION ENGINEERS

Australian/New Zealand Standard

Performance Based Gas Detection System Design For

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

Australian Standard. Emergency escape lighting and exit signs for buildings. Part 1: System design, installation and operation AS 2293.

Australian/New Zealand Standard

TetraTek, Inc. Regulatory. Compliance. Emergency Response. Nuclear Facility Compliance. Compliance. Fire Protection.

Australian/New Zealand Standard

EXIT ROUTES, EMERGENCY ACTION PLANS, AND. FIRE PREVENTION PLANS. PART 1: INTRODUCTION

Standard Development Timeline

Analysis of Changes for the 5 th Edition (2014) of the Florida Codes

Australian/New Zealand Standard

Small LP Gas Jurisdictional Systems. Kim Lapierre Technical Training Manager John Minchew Area Safety Manager West

SURREY FIRE SERVICE. Construction Fire Safety Plan Bulletin

AS/NZS :1995. Emergency escape lighting and exit signs for buildings AS/NZS :1995. Part 2: Inspection and maintenance

Changes for the New Edition. Senior Engineer, NFPA NFPA

GAS PIPELINE OPERATIONS

Australian/New Zealand Standard

Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope

Adoption of The 2007 Dallas Fire Code

Loss Prevention Standard

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

Compliance Guidance for non-technical managers

AS/NZS 4745:2012. Code of practice for handling combustible dusts AS/NZS 4745:2012. Australian/New Zealand Standard. Superseding AS/NZS 4745:2004

DRAFT TANZANIA STANDARD

Petroleum Gas Systems - 1 -

Major Changes Nova Scotia Building Code 2011 Construction and Maintenance Regulatory Change Industry Briefing

Koffel Associates, Inc.

IIPP. Injury & Illness Prevention Program Hartog Drive San Jose CA Responsibilities. Workplace Hazards. Training. Incident Investigations

Iowa Propane Gas Association 2018 Training Descriptions

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning. Part 1: Fire AS 1670.

NJSP HMRU. Module 5 B HM Operations 1

Fire Safety Plan Information. For Construction and Demolition Sites

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

Australian Standard. Fixed fire protection installations Pumpset systems AS AS 2941

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

Executive Summary of Qualifications

Family Foster Home Fire Safety Evaluation Checklist Instructions

2012 Virginia Residential Fuel Gas Code & 2012 International Fuel Gas Code Update Training

2012 Virginia Residential Fuel Gas Code & 2012 International Fuel Gas Code Update Training

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

WARM WELCOME RISK ASSESSMENTS & HOMESTAY FIRE/GAS SAFETY

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN

NFPA 70E Edition Update

UL268 7 th challenge with single infrared smoke detector

Australian Standard. Gaseous fire extinguishing systems AS (Incorporating Amendment No. 1) AS

AS/NZS :2014. Electrical equipment for coal mines Introduction, inspection and maintenance AS/NZS :2014. Part 1: For hazardous areas

Committee on NFPA 85

Fire Patterns. Introduction. Skills Objectives. Fire Effects and Fire Patterns (2 of 2) 12/20/ Knowledge Objectives

Codes and Standards FFP1510, BFST1510, ATCP1510

Australian Standard. Fire detection, warning, control and intercom systems Control and indicating equipment. Part 1: Fire

RESNET Infrared Inspection Standard and Certification

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

ISO INTERNATIONAL STANDARD

Australian/New Zealand Standard

Australian Standard. Automatic fire detection and alarm systems System design, installation, and commissioning AS

Slot Home Task Force Meeting #5 Phase 2 June 8, 2017

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

Winnipeg Fire Department Fire Prevention Branch

SUPLEMENTAL AGENDA. A17 Hoistway Committee. Doubletree by Hilton New Orleans 300 Canal Street New Orleans, LA

Substations and high voltage installations exceeding 1 kv a.c.

AS 1851:2012 The Use and Adoption of the New Standard The impacts and challenges for the fire protection and property management industries.

Australian Standard. Fire hydrant installations. Part 1: System design, installation and commissioning AS

This document is a preview generated by EVS

Knowledge Objectives (2 of 2) Fuel Gas Systems. Skills Objectives. Introduction. Fuel Gas Systems (1 of 6) 12/20/2013

Australian/New Zealand Standard

GAS SAFETY REGULATION

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Liquefied Petroleum Gas Facility Written Fire Safety Analysis

INTERNATIONAL STANDARD

NFPA 80 Overview January 21, 2016

Title: BFST1505 Syllabus

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

UNDERSTANDING ELECTRICAL SAFETY RISKS

Bold items are particular to the City of Euless

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

Alternative Fuels Applications

INTERNATIONAL STANDARD

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

First Revision No. 20-NFPA [ Section No ]

Iowa Propane Gas Association 2011 Training Descriptions

NFPA Fire Inspector I Study Guide

DRAFT TANZANIA STANDARD

TECHNICAL SPECIFICATION

1.3 REFERENCE STANDARDS

ISO INTERNATIONAL STANDARD. Smoke alarms using scattered light, transmitted light or ionization

ARTICLE 25. FUEL GAS CODE

Australian/New Zealand Standard

Are You Prepared? The impending impact of Code on Servicing Security Systems

Based on NFPA 1003: Standard for Airport Fire Fighter Professional Qualifications 2015 Edition

AS/NZS :2015

FIRE & LIFE SAFTEY STANDARD

Hydrostatic Retest Requirements for ANSUL Pressure Vessels

Australian/New Zealand Standard

Transcription:

Pipeline Personnel Qualification ASME B31Q Update Presented by: Mike Gruenberg Southwest Gas Corporation

Historical Perspective 1999: PHMSA published Operator Qualification (OQ) rule 2002: NTSB labeled Operator Qualification as unsatisfactory 2003: PHMSA issued 13 areas they considered as gaps in the rule 2003: Four public meetings held to address the 13 issues 2003: ASME B31Q Project Team formed to develop a technically sound, holistic, consensus standard for the qualification of pipeline personnel 2005: PHMSA amended OQ rule to address training, on-the-job performance and reporting significant plan changes 2006: ASME published the first edition of B31Q 2010: ASME published the second edition of B31Q

Underlying Principles of ASME B31Q Scope covers tasks that impact the safety or integrity of the pipeline Technically based Prescriptive and Performance options Performance options should have higher expectations on processes Limited number of simple processes for each technical issue with freedom to develop operator s own methods

Underlying Principles of ASME B31Q Clear should be clear and concise Durable adequate for multiple cycles Complete answers all known technical issues Sound technically sound foundation Use existing rule where practical Not a regulatory document

ASME B31Q Benefits Standardized task list Standardized requalification frequencies Identifies key qualification components Allows for portability Rationales are embedded in document Accepted by PHMSA Reduction in future changes to OQ rule

Work-in-Progress from 2006 Standard Editorial refinement Portability Jobs vs. Tasks Qualification exemptions New construction New tasks Expanded task criteria

Integrated Task List Examples Task 1231 Inside Gas leak Detection L G D Difficulty Importance Interval Method Span of Control X X 3 5 3 YRS. Initial/Sub: P&W/O Task Guidance: This task includes the investigation of reported or discovered leaks of operator s lines inside a building in relation to emergency response. This also includes initiation of precautionary actions (make safe). Repairing and proving the integrity of customer piping and lighting customer utilization equipment are not included. 1:1 1) Identify requirements 2) Perform test equipment check 3) Perform leakage investigation 4) Initiate precautionary actions 5) Recognize and react to AOCs 6) If required, complete documentation

Additional Guidance: Identify requirements: Leak investigation procedures Select the appropriate leak investigation equipment Combustible gas indicator Laser Methane detector Flame Ionization Infrared Soap Field start up of equipment Check filters, probes, fuel supply, batteries, etc. Operational check as required by manufacturer Periodic calibration check

Additional Guidance: Perform leak investigation Make customer/caller contact Check for the presence of a combustible gas throughout the structure Include areas such as: floor drains, electrical outlets, at ceiling level, and other areas where gas could accumulate Initiate precautionary actions Eliminate sources of ignition Evacuate the structure Implement emergency response actions Continue to monitor Recognize and react to AOCs If required, complete documentation

Integrated Task List Components Task 1291 Locate Underground Pipelines L G D Difficulty Importance Interval Method Span of Control X X X 3 3 3 YRS. P&W/O 1:1 Task Guidance: This task includes locating underground pipelines utilizing maps, records, and locating equipment. It also includes placing temporary markers or markings. 1) Identify requirements 2) Select method for locating 3) Perform test equipment check 4) Visually inspect locate area 5) Locate pipelines and place temporary marker(s) 6) Recognize & react to AOCs 7) If required, complete documentation

Additional Guidance: Identify requirements: Line Locate Procedures One-call ticket Select the method for locating Direct connection Indirect connection Documentation Perform test equipment check (if applicable) Split box Single frequency Multi frequency Ground penetrating radar Acoustic

Additional Guidance: Visually inspect locate area Identification of the locate area (white lines) Pipeline markers Pipeline facilities (valve box, meter sets, regulator stations, etc.) Evidence of excavations Evidence of other utilities Previous locate marks (paint, whiskers, flags, etc. ) Locate Pipeline Validate/compare physical locate to existing documentation Maps Service cards As-builts Construction drawings

Additional Guidance: Pothole/expose facility if documentation and physical locate do not match Place temporary markers on successfully located facility Paint Flags/chasers/whiskers Stakes If required, complete documentation Create work order to correct errors in facility location documentation

New Covered Tasks Under Consideration Operations and maintenance of auxiliary equipment Dehydrators Separators Heaters Coolers

Other Non Task Related Items Under Consideration New technology Long-term degradation of physical abilities New appendix for interpretations

PHMSA Perspective B31Q addresses the OQ noncompliance issues found to date. PHMSA has publicly stated If you meet ASME B31Q, you will meet the regulation.

Standards vs. Regulations Keeping Things in Perspective International standards No jurisdictional bounds Regulators can adopt all or part of a standard

Ways to Participate Comments to secretary Work through members Attend meetings Upcoming meetings Dallas, March 24-25, 2009 Denver, August 2009 Web site: www.asme.org Search on B31Q Committee

Summary Value of current standard More work to be done Your participation is welcome Using the standard now and in the future

Questions

Contact Information ASME: http://www.asme.org/ Mike Gruenberg Michael.gruenberg@swgas.com (702) 668-6401