Performance investigation of Air-conditioning system using ejector as expansion device

Similar documents
Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Performance characteristics of low global warming potential R134a alternative refrigerants in ejector-expansion refrigeration system

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

International Engineering Research Journal Performance Analysis of Ejector Based Solar Air Conditioning System

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Experimental analysis of condensation heat transfer enhancement of steam at low pressures using modified twisted tape insert

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

ABSTRACT. Research Professor Yunho Hwang, Ph.D. Department of Mechanical Engineering

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

(Refer Slide Time: 00:00:40 min)

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

International Journal of Informative & Futuristic Research ISSN (Online):

Energy and Exergy Analysis of an Ejector-Absorption Refrigeration Cycle with Using NH3-H2O as the Working Fluids

A study of Transient Performance of A Cascade Heat Pump System

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Week 9. Refrigeration Cycles I. GENESYS Laboratory

II. OBJECTIVE OF RESEARCH

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

ENSC 388. Assignment #6

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN

SAMPLE STUDY MATERIAL

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Adsorption refrigeration system using waste heat

Purdue e-pubs. Purdue University

Numerical Simulation of Window Air Conditioner

Global Journal of Engineering Science and Research Management

SSC-JE STAFF SELECTION COMMISSION MECHANICAL ENGINEERING STUDY MATERIAL REFRIGERATION CYCLES REFRIGERATION CYCLES REFRIGERATION CYCLES

*Corresponding author;

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Experimental and Numerical Study on the Performance of R410A Liquid Recirculation Cycles with and without Ejectors

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

Enhancement of COP using Nanoadditives in Domestic Refrigerator

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

Performance Analysis of Solar Assisted Cascade Refrigeration System of Cold Storage System

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Thermodynamic Calculations of Two-Stage Vapor Compression Refrigeration Cycle with Flash Chamber and Separate Vapor Mixing Intercooler

Performance of an Improved Household Refrigerator/Freezer

Experimental assessment of a PCM to air heat exchanger storage system for building ventilation applications

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Performance Enhancement of Mini Refrigerator with Phase Change Materials

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

Capillary Tube and Thermostatic Expansion Valve Comparative Analysis in Water Chiller Air Conditioning

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

EXPERIMENTAL INVESTIGATION OF VAPOUR ABSORPTION SYSTEM

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Enhancement of COP in Vapour Compression Refrigeration System

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

DEEPAK PALIWAL, S.P.S.RAJPUT

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Chapter 9. Refrigeration and Liquefaction

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

The analysis and experimental investigation of heat pump system of R404A and R410A using thermobank and a two-phase ejector

Effects of Non-Uniform Refrigerant and Air Flow Distributions on Finned- Tube Evaporator Performance

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Transcription:

International Journal of Current Engineering and Technology E-ISSN 2277 416, P-ISSN 2347 161 216 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Performance investigation of Air-conditioning system using ejector as expansion device Harish Choudhary *, B.S.Kothavale and K.V.Mali Department of Mechanical Engineering, MIT College of Engineering, Savitribai Phule Pune University, India Accepted 1 June 216, Available online 2 June 216, Special Issue- (June 216) Abstract This paper discusses the use of Ejector as an expansion device as an energy efficient alternative to expansion valve in air conditioning system to improve the system performance. Expansion Process in Vapour Compression refrigeration system represents one of the important sources of irreversibility. Ejector was used instead of conventional expansion device which not only recover the expansion process loss by generating isentropic expansion process but also by increasing the cooling capacity and decreasing the power consumption. Initially experimental test was conducted on window air conditioner with standard expansion valve and then with ejector.test were also conducted to re-circulate the liquid at the outlet of evaporator if any by using separator through valve to ejector. These act as secondary flow which was controlled by using hand valve. The coefficient of performance (COP) values for both conventional and modified ejector systems were experimentally investigated under same external conditions. Modified ejector refrigeration system shows 2% improvement in COP as compared with conventional system. Keywords: Ejector, window air conditioning system, cooling capacity, power consumption. 1. Introduction 1 Vapour compression cooling cycles deviate from the Carnot refrigeration cycle in several ways, such as isenthalpic expansion of saturated liquid at the condenser outlet and desuperheating of refrigerant vapour at the compressor outlet. Therefore, COPs of vapour compression cooling cycles are always lower than those of a Carnot cycle under the same working conditions. Isenthalpic expansion imposes a double penalty on cycle performance compared with isentropic expansion in the Carnot cycle: the cooling capacity is reduced and the compressor work is increased. Expansion work recovery devices such as ejectors which recover the kinetic energy released during the expansion instead of wasting it in a throttling process are known to be useful to cycle performance. This loss is due to kinetic energy consumption by swirl flow in the expansion valve. No studies regarding the expansion-valve cycle have focused on this energy loss in the expansion valve. If expansion energy loss can be eliminated and the energy otherwise lost used as compressor power, it is possible to improve refrigerating capacity while at the same time lowering compressor power consumption. An ejector is an ideally isentropic expansion device capable of recovering the work that is otherwise lost *Corresponding author: Harish Choudhary by the isenthalpic throttling process associated with the expansion valve in conventional air-conditioning cycles. In an ejector, a high-pressure motive stream is expanded through a converging-diverging nozzle (motive nozzle) to a low pressure and high velocity. At the same time, a low-pressure suction stream enters the ejector through a separate, generally converging only, nozzle (suction nozzle) and is entrained by the motive fluid through momentum transfer between the two streams. After mixing has occurred between the two streams, they enter a diffuser, where they are further decelerated and compressed to a pressure higher than the initial pressure of the suction stream. Thus, the effect of the ejector is to provide a pumping effect to the suction stream by means of expansion of the motive stream. 2. Literature Review Disawas and Wongwises experimentally investigated the performance of ejector refrigeration system. They proposed that, in addition to serving as an expansion device, the ejector can also act as a refrigerant pump for the low-pressure side of the system. The evaporator is therefore flooded with refrigerant and operates as in a liquid recirculation system. Their experimental results showed that the COP of the two-phase ejector refrigeration cycle using R134a was higher than that of the baseline cycle using expansion valve over the whole range of experimental conditions. The maximum 188 MIT College of Engineering, Pune, India, MECHPGCON 216, INPRESSCO IJCET Special Issue- (June 216)

Harish et al improvement achieved was about 13% at low heat sink and heat source temperatures. Less attention has been given to low-pressure working fluids in the literature for ejector cooling cycles compared with R744 due to their lower work recovery potential. However, ejector cooling cycles using low-pressure refrigerants, such as R134a or R1234yf, can still have noticeable performance improvements. Nehdi et al. numerically investigated that replacing the throttle valve with a two-phase ejector improved COP up to 22% in a vapour compression system using R-141b as refrigerant. Bilir and Ersoy performed experiment refrigeration system using two phase ejector as expander. It was found that depending on operating condition, the work recovery in the ejector was 14% and 17%.Their experimental showed that COP of ejector refrigeration system was 6.2-14.% higher than that of conventional system. Pottker and Hrnjak experimentally tested an R41A EEC and reported improvements from 8.2% to 14.8% over the basic system. Lawrence and Elbel experimentally investigated the performance of an alternate two phase ejector refrigeration system. Maximum COP improvement of 8% with R134a and 12% with R1234yf was found. Sumeru et al numerically and experimentally investigated alternate ejector refrigeration cycle in air conditioning system which shows increased in COP of 4.17, 11.14 and13.78% at ambient temperature of 3, 3 and 4 o C respectively. 3. Standard and modified ejector cycle inlet pressure, work of compression is reduced as compared with basic cycle. Evaporator cooling capacity is also increased since evaporator is flooded with liquid refrigerant at the inlet of evaporator. Hence COP of the system also increases. Fig. 1 Ejector refrigeration cycle with P-h diagram 3.2 Modified Ejector refrigeration system Fig.2 Modified ejector refrigeration cycle 3.1 Standard Ejector refrigeration system Two-phase ejector-expansion refrigeration cycle along with P-h diagram is shown in figure. It consist of two extra components i.e. ejector and separator as compared with conventional system. The high pressure liquid refrigerant coming out from condenser is expanded through motive nozzle of the ejector. This expansion of the high-pressure liquid refrigerant is useful to entrain and raises the vapour pressure of refrigerant at the outlet of the evaporator. This expansion of the high-pressure liquid refrigerant is useful to entrain and raises the vapour pressure of refrigerant at the outlet of the evaporator. Liquid refrigerant coming from outlet of condenser is called primary flow and flow coming from evaporator outlet is called secondary flow. Mixing of both the fluid takes place in mixing chamber. At Diffusion nozzle, fluid is decelerated, hence pressure will increase. This pressure is higher than initial pressure of suction stream. At the outlet of the ejector the two-phase fluid is sent to the liquid-vapour separator, where the vapour refrigerant enters the compressor and finally becomes the motive stream, while the liquid refrigerant returns to the evaporator through a throttle valve and finally becomes the suction stream. Due to higher compressor Figure shows the layout diagram of modified ejector refrigeration system. It has small modification as compared to standard ejector refrigeration system. High pressure liquid refrigerant at the outlet of condenser is expanded in motive nozzle, which act as primary flow.at proper position, liquid at lower part of separator is sucked due to pressure difference and act as secondary flow. In the mixing chamber, fluid is decelerated further in diffusion section and compressed to a pressure higher as compared with initial pressure of the suction stream. The fluid at the outlet of the ejector is sent to the evaporator. Outlet of evaporator is send to liquidvapour separator, where the vapour enters the compressor which act motive stream, while the liquid refrigerant which returns to the evaporator through a hand valve becomes the suction stream. Hence flow can be controlled by regulating hand valve. 4. Experimental setup without Ejector First the performance of air conditioning system was tested without ejector and theoretical and actual coefficient of performance was calculated for existing window air conditioning system. 189 MIT College of Engineering, Pune, India, MECHPGCON 216, INPRESSCO IJCET Special Issue- (June 216)

Harish et al thermocouples which measure temperature at various places namely T1,T2,T3,T4,T,T6,T7 and three pressure gauges P1,P2,P3 were used. Hand valve was used to control the flow from separator to ejector. Fig. 3 Schematic of experimental setup without ejector Figure shows schematic layout of experimental setup without ejector. Two pressure gauges were used to measure inlet and outlet pressure of compressor. Five thermocouples were used at various positions as shown in figure. Power consumed by window air conditioning system was calculated by using wattmeter. To have steady reading, total ten reading were taken at an interval of 1 minutes. Coolpack was used to draw actual and ideal cycle. Coolpack is a collection of simulation tools for refrigeration prepared by Department of Energy Engineering, Technical University of Denmark. Actual cooling capacity was calculated by one of the simplest methods where dry and wet bulb temperature were calculated at lower compartment where air flows in over the cooling coils of evaporator and at upper compartment where cooled air thrown out were calculated by pychrometer. Mass flow rate was calculated by measuring velocity at lower and upper compartment. Anemometer was used to measure velocity. Fig. Schematic of experimental setup with ejector.1 Experimental procedure Initially valve was totally closed and tests were conducted. Temperature and pressure reading were taken at various positions, at the same time a wet and dry bulb temperature were calculated at lower and upper compartment of window air conditioner. Velocity of air was calculated using anemometer. Separator Hand Valve Ejector Fig. 4 Actual cycle drawn in coolpack software Figure shows cycle of vapour compression system without ejector drawn using Coolpack. Cycle shows Evaporation cooling capacity and heat rejection by condenser.. Experimental with ejector Setup Figure shows the layout diagram of experimental setup with ejector. Ejector,separator,valve were the extra component used to make changes in the system. These changes were made in same window air conditioner. Experimental setup consist Fig. 6 Actual experimental setup Now to re-circulate liquid refrigerant if any present at outlet of evaporator, valve was open gradually. Liquid refrigerant which was collected at the bottom, act as secondary flow to ejector. Hence, by adjusting the position of valve, pressure and temperature reading were noted. 6. Results and discussion Various results were plotted by changing valve position. Hence seven positions were used 19 MIT College of Engineering, Pune, India, MECHPGCON 216, INPRESSCO IJCET Special Issue- (June 216)

Compressor Outlet temperaturet2 Evaporator inlet temperature T4 Compressor inlet temperature T1 Condenser Outlet temperature T3 Harish et al i.e,%,7%,12.%,2%,%,7% and 1%.Therefore % indicates fully closed and 1 % indicates fully open. 6.1 Effect on compressor inlet temperature 6.3 Effect on condenser outlet temperature 4 2 2 1 1 4 3 3 2 Fig. 9 Variation of condenser outlet temperature with Fig. 7 Variation of compressor inlet temperature with The above figure 7 shows variation of compressor inlet temperature at different position. It was seen that between to 2 % of compressor inlet temperature decreases randomly and afterward it almost remain constant for other valve opening position. It indicates that after 7% opening of the valve there was reverse flow taking place from ejector to the separator. Therefore, the compressor inlet temperature decreases. 6.2 Effect on Compressor outlet temperature 96 94 92 9 88 86 84 82 8 Figure shows the variation of condenser outlet temperature with different. Condenser Outlet Temperature remains almost constant at various valves opening position. This indicates that there is no effect of on condenser outlet temperature. 6.4 Effect on Evaporator inlet temperature 9 8 7 6 4 3 2 1 Fig. 8 Variation of compressor outlet temperature with Fig. 1 Variation of evaporator inlet temperature with The above figure 8 shows the variation of compressor outlet temperature with different. Initially from to 7 % opening of valve the compressor outlet temperature increase and after that it decreases. This decrease in outlet temperature was due to decrease in inlet temperature in compressor as shown in figure 7. Figure shows the variation of evaporator inlet temperature with different position. Evaporator inlet temperature decreases with different position. Since after 7% opening of valve, there was reverse flow. Hence due to reduction in compressor inlet temperature, there was also drop in evaporator inlet temperature. 191 MIT College of Engineering, Pune, India, MECHPGCON 216, INPRESSCO IJCET Special Issue- (June 216)

Cooling capacity Evaporator Outlet temperature COP Actual Harish et al 6. Effect on Evaporator outlet temperature 6.7 Effect on actual COP 3 2 2 1 1 Fig. 11 Variation of evaporator outlet temperature with Figure shows variation of evaporator outlet temperature with different valve position. It shows that evaporator outlet temperature increases with opening of valve. This shows that, there is superheating of refrigerant at outlet of evaporator due to reduced mass flow rate of refrigerant to evaporator. 6.6 Effect on cooling capacity 2. 2 1. 1. Fig. 13 Variation of Actual COP with Figure shows variation of actual COP with different. COP increases first up to 7 % opening of valve and then gradually decreases up to 2 % opening of valve and then it almost remain constant from 2% to 1%opening of the valve. The actual COP of the system mainly increases due to increase in cooling capacity and decrease in power consumption. Conclusions 4 3 2 1 Valve Opening The performance of window air conditioning system with modified ejector refrigeration system was been tested and analysed for different positions. The focus of this work was to increase the cooling capacity and decrease the power consumption. Table 1 Comparison between two cycle performances Sr.no Description Vapour compression refrigeration cycle Modified Ejector Refrigeratio n cycle 1 Cooling capacity 3.789kW 4.32kW Fig. 12 Variation of cooling capacity with valve opening 2 Work input 2 kw 1.9 KW 3 Coefficients of performance 1.89 2.27 Figure shows variation of cooling capacity at different. Cooling capacity first increases and then decreases. This was mainly due to reversed flow in system after 7% opening of the valve. At 7% opening of the valve maximum, cooling capacity was obtained. After that for almost all other positions, cooling capacity remains constant. Hence when valve was completely closed modified ejector refrigeration system shows improvement of 6% as compared with conventional cycle. But at 7 % opening of valve it shows 14% improvement in cooling capacity as compared with vapour compression refrigeration cycle. The experimental results shows that, 1) Cooling capacity of modified ejector refrigeration system at 7% opening of valve was increase by 14% over the conventional vapour compression refrigeration cycle of window air conditioning system. 2) Power consumption of modified ejector refrigeration system at 7% opening of valve was decrease by % over the conventional vapour compression refrigeration cycle of window air conditioning system. 3) The coefficient of performance of modified ejector refrigeration system at 7% opening of valve was 192 MIT College of Engineering, Pune, India, MECHPGCON 216, INPRESSCO IJCET Special Issue- (June 216)

Harish et al increase by 2% over the conventional vapour compression refrigeration cycle of air conditioning system. References Jingwei Zhu and Stefan Elbel (216), A New Control Mechanism for Two-Phase Ejector in Vapor Compression Cycles for Automotive Applications Using Adjustable Motive Nozzle Inlet Swirl, SAE International,216-1-243. Disawas, S.; Wongwises S., (24), Experimental investigation on the performance of the refrigeration cycle using a two-phase ejector as an expansion device. International Journal of Refrigeration, 27, 87 94. Nehdi, E.; Kairouani, L.; Bouzaina, M.,(27) Performance analysis of the vapour compression cycle using ejector as an expander. International Journal of Energy Recourses, 31, 364 37. Bilir, N.; Ersoy H.K.,(29)Performance improvement of the vapour compression refrigeration cycle by two-phase constant area ejector. International Journal of Energy Recourses, 33, 469 48. Pottker, G.; Hrnjak, P.,(21) Ejector in R41A vapor compression systems with experimental quantification of two major mechanisms of performance improvement: Work recovery and liquid feeding. International Journal of Refrigeration,, 184 192. Lawrence N.; Elbel, S., (214),Experimental investigation of a two-phase ejector cycle suitable for use with low-pressure refrigerants R134a and R1234yf, International Journal of Refrigeration, 38, 31 322. H. K. Kasni Sumeru, Shodiya Sulaimon, Henry Nasution, Farid Nasir Ani,(214), Numerical and experimental study of an ejector as an expansion device in split-type air conditioner for energy savings., Energy and Buildings, 79,98-1. Ersoy, N. Bilir Sag (214), Preliminary experimental results on the R134arefrigeration system using a two-phase ejector as an expander, International Journal of Refrigeration 43, 97-11. Coolpack(collection of simulation tools for refrigeration),department of energy engineering, Technical university of Denmark. 193 MIT College of Engineering, Pune, India, MECHPGCON 216, INPRESSCO IJCET Special Issue- (June 216)