BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS

Similar documents
USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V

VIGÖR HRV PLUS AND VIGÖR ERV

USER GUIDE HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+, MODEL ERV 90H-V ECM PLEASE READ AND SAVE THESE INSTRUCTIONS

USER MANUAL HRV150S* HRV190S* AND ERV180S READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1.

HEAT RECOVERY VENTILATORS MODELS AVS E15 ECM HRV, AVS E15 HRV, AVS E10 HRV AND ENERGY RECOVERY VENTILATOR MODEL AVS E15 ECM ERV

Address of your installer

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

Heat Recovery Ventilators models:

HEAT RECOVERY VENTILATORS AND ENERGY RECOVERY VENTILATORS CONSTRUCTO 1.0 MODELS: Model no.: (HRV with ports on top)

Address of your installer

HEAT RECOVERY VENTILATORS HRV 60H ERV 60H. User Guide AND ENERGY RECOVERY VENTILATORS. Model no.: (HRV with ports on top)

INSTALLATION GUIDE VB0180 VB0148

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

Installation Information

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER

INSTALLATION GUIDE FOR VENMAR AVS CONSTRUCTO 1.5* AND CONSTRUCTO 2.0

Maintenance Matters. Maintaining Your Heat Recovery Ventilation System

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

Heat Recovery Ventilation Systems OWNER S GUIDE

HE365A,B Powered Flow-Through Humidifier with

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

HE360A,B Powered Flow-Through Humidifier

INSTALLATION GUIDE VÄNEE HRV 60H AND ERV 60H

Bosch Split-Type Ductless Air Conditioner / Heat Pump

HEAT PUMP A GUIDE TO OPERATING AND MAINTAINING YOUR RESIDENTIAL HEAT PUMP UNIT NOTE TO INSTALLER: THIS MANUAL SHOULD BE LEFT WITH THE EQUIPMENT USER.

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

INSTALLER MANUAL RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS

OPERATING INSTRUCTIONS

user s information manual

For Models Superventor Series

INSTALLATION GUIDE FOR VENMAR AVS UNIT CONSTRUCTO 1.0 HRV AND CONSTRUCTO 1.0 ERV

INSTALLER AND USER MANUAL VENTILATION SYSTEM

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

Inverter Split-type Room Air Conditioner

FOR MODELS: VENMAR 1.3, 1.8 & 2.6 HE VENMAR 3055 & 5585 COMPACT vänee 1000, 2000 & 3000 HE

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

PORTABLE AIR CONDITIONER

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

Condensation on Your Windows?

NEXXOS INVERTER USER MANUAL

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

CMHC HOME MAINTENANCE CHECKLIST

HE420A,B and HE460A,B Steam Power Humidifiers OWNER S GUIDE

RXIH-AB12A and RXIH-AB17A By-Pass Flow-Through Humidifiers

INSTALLATION INSTRUCTIONS AND USER GUIDE

Owner s Manual CMC100 Dehumidifier

Indoor Air Quality Product Brochure.

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Owner s Manual CMC100 Dehumidifier

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

HE360 Powered Flow-Through Humidifier

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

Using the Remote Control Unit

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

Put the V back in HVAC

INSTALLATION INSTRUCTION & OWNER S GUIDE

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

CENTRAL AIR CONDITIONER

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

TR Series - The Ultimate ERV

ROTARY CONTROL AIR CONDITIONER

ENERGY RECOVERY VENTILATOR

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

USER S INFORMATION MANUAL (2,4)SG13B

INSTALLATION MANUAL MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Fig. 1 - Unit PHD4 and WPH4

Novofit 2.0 (Part no )

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Owner s Manual TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS OWNER S MANUAL FOR BYPASS AND FAN POWERED HUMIDIFIERS. Small or Large Bypass 12 Water Saver Bypass 13 Fan Powered 14

Split Portable Air Conditioner

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

INSTALLATION GUIDE FOR AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, HRV 90H-V ECM AND 90H-V UNITS

Owner s Information Manual

Home Maintenance Schedule

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

SLIDER CASEMENT AIR CONDITIONER

Owner s Manual. Fairwind Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

KSD-35 DR11 KUE-35 DVN11

HE365A,B Powered Flow-ThroughHumidifier with

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

HEAT & COOL MODEL (REVERSE CYCLE)

HOME OWNERS GUIDE ERV MODEL PE 7.15 PE SS Product of Imperial Air Technologies

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

DLFEHA. OWNER S MANUAL High Wall Ductless System Sizes 09 to 24 TABLE OF CONTENTS

CPG*CA CPG*CD CGC*CA CGC*CD CIM*CA CIM*CD CPP*CA CPP*CD

!""#$# !%&'())('*+%,-, #./0('*%1,!%&'023'*+%&

HE365A,B Powered Flow-ThroughHumidifier with JI

USER S MANUAL AQV09J Series AQV12J Series AQV18J Series AQV24J Series

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

Transcription:

USER GUIDE VB0110 BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS *This product earned the ENERGY STAR by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US EPA. It meets ENERGY STAR requirements only when used in Canada. 03450 rev. C

CONGRATULATIONS! You have made an excellent choice! We have prepared this User Guide especially for you. Please read it carefully to ensure you obtain full benefits from your Heat Recovery Ventilator unit. About this Guide This guide uses the following symbols to emphasize particular information:! WARNING Identifies an instruction which, if not followed, might cause serious personal injuries including possibility of death. Denotes an instruction which, if not followed, may severely damage the unit and/or its components. NOTE: Indicates supplementary information needed to fully complete an instruction. TABLE OF CONTENTS 1. UNIT DESCRIPTION..........................................................3 1.1 SPECIFICATIONS...........................................................................3 2. FUNCTION OF THE HEAT RECOVERY VENTILATOR...............................3 2.1 HEAT RECOVERY..........................................................................3 2.2 DEFROSTING.............................................................................3 3. CONTROLS...............................................................4-6 3.1 INTEGRATED CONTROL......................................................................4 3.1.1 BOOT SEQUENCE.....................................................................4 3.2 OPTIONAL MAIN WALL CONTROLS..............................................................4 3.2.1 LITE-TOUCH BRONZE..................................................................4 3.2.2 BRONZE...........................................................................5 3.3 OPTIONAL AUXILIARY CONTROLS...............................................................6 3.3.1 HUMIDITY CONTROL...................................................................6 3.3.2 20-MINUTE LIGHTED PUSH BUTTON.......................................................6 3.3.3 60-MINUTE MECHANICAL TIMER..........................................................6 4. MAINTENANCE..............................................................7 4.1 REGULAR................................................................................7 4.2 PROLONGED..............................................................................7 5. TROUBLESHOOTING.........................................................8 1. Some activities create dust or vapors which may damage your unit. You must, therefore, turn off and unplug your unit in the following situations: major renovation work housing construction sanding (e.g. gypsum joints, etc.) varnishing 2. During heavy snow storms, turned off the unit to avoid problems caused by snow penetration, even if it is equipped with anti-gust intake hood. 3. Power disturbances or very short power failures may cause the electronic control microprocessor to malfunction. If it does, disconnect the power plug from the outlet and wait approximately 30 seconds, then plug it back in to resume operation. 2

1. UNIT DESCRIPTION 1. Filters 2. Blowers 3. Condensation tray 4. Heat recovery core 1 2 3 4 1 1 VB0097 1.1 SPECIFICATIONS MODEL WIDTH HEIGHT DEPTH WEIGHT ELECTRICAL SUPPLY POWER CONSUMPTION 90H 30¼ (768 MM) 16½ (419 MM) 17¼ (438 MM) 66 LB (30 KG) 120 V, 60 HZ 150 W 190H 30¼ (768 MM) 16½ (419 MM) 17¼ (438 MM) 68 LB (30 KG) 120 V, 60 HZ 240 W 2. FUNCTION OF THE HEAT RECOVERY VENTILATOR Your ventilation system will help eliminate poor air quality problems by drawing the stale and humid air out of the house and replacing it with fresh outside air. By eliminating accumulated pollutants and humidity, it maintains an optimum air quality and an ideal relative humidity during cold season. The unit is also equipped with a heat recovery core which reduces ventilation costs in winter. Shown with a forced air heating system; can also operate on its own. VH0006 2.1 HEAT RECOVERY Units equipped with a heat recovery core can reduce ventilation costs in winter. The unit draws the heat from the stale air and humid air before it is released and uses it to heat the air coming in from outside. The recovery core is designed in such a way that the stale air is never mixed with the fresh air. Exhaust air to outside 6 C/43 F Fresh air from outside 0 C/32 F Example: (in winter) VF0026 Fresh air to building 16 C/61 F Exhaust air from building 22 C/72 F 2.2 DEFROSTING When the outside temperature is below -5 C (23 F), heat recovery creates frost in the core. To maintain its proper operation, the unit is programmed to defrost the recovery core. The defrosting frequency varies according to outside temperature. Defrosting lasts 7 or 10 minutes, according to outside temperature. During the defrost cycle, the unit shifts to maximum speed and the dampers close. After defrosting, the unit returns to the operating mode previously selected by the user. 3

3. CONTROLS 3.1 INTEGRATED CONTROL All units are equipped with an integrated control, located in front of the electrical compartment. Use the push button (1) to control the unit. The LED (2) will then shows on which mode the unit is in. 1 2 VD0193 Refer to table below to see how to operate the unit using its integrated control. PRESS ON PUSH BUTTON LED COLOR RESULTS ONCE AMBER UNIT IS ON LOW SPEED TWICE GREEN UNIT IS ON HIGH SPEED THREE TIMES NO LIGHT UNIT IS OFF If a problem occurs during the unit operation, its integrated control LED (2) will blink. The color of the blinking light depends on the type of error detected. Refer to Section 5 Troubleshooting on last page for further details. 3.1.1 BOOT SEQUENCE The unit boot sequence is similar to a personnal computer boot sequence. Each time the unit is plugged after being unplugged, or after a power failure, the unit will perform a 30-second booting sequence before starting to operate. During the booting sequence, the integrated control LED will light GREEN or AMBER for 5 seconds, and then will shut off for 2 seconds. After that, the LED will light RED for the rest of the booting sequence. During this RED light phase, the unit is checking and resetting the motorized damper position. Once the motorized damper position completely set, the RED light turns off and the booting sequence is done. NOTE: No command will be taken until the unit is fully booted. 3.2 OPTIONAL MAIN WALL CONTROLS For more convenience, this unit can also be controlled using an optional main wall control. NOTES: 1. The integrated control must be turned OFF to use an optional main control. 2. If an optional auxiliary control is used, if activated, this auxiliary control will override the optional main control. 3.2.1 LITE-TOUCH BRONZE Location: Located in the busiest area of the house. Purpose: To adjust air supply. Activate the push-button. The color of the indicator shows the unit operating mode. Color Mode Suggested Use Green Intermittent Select this mode when you are away from the house for a few days. Also, when you deem the inside air is too dry in heating season, or too humid in cooling season. In this mode, the unit is OFF for 40 minutes per hour and ventilates at minimum speed the remaining 20 minutes of the hour. Yellow Min. Speed For normal daily operation. Ventilation Red Max. Speed For excess pollutants and humidity (parties, odors, smoke, etc.). Ventilation VC0080 MAX MIN INTERMITTENT L-T 4

3. CONTROLS (CONT D) 3.2 OPTIONAL MAIN WALL CONTROLS (CONT D) 3.2.2 BRONZE Location: Purpose: Located in the busiest area of the house. To adjust air supply and select desired indoor humidity level. % RELATIVE HUM IDITY Adjusting the AIR SUPPLY CONTROL: a) Select speed MIN. or MAX. using switch A (as shown on diagram). Select speed MIN. (minimum speed) for normal daily operation (24 hours a day all year round). Select MAX. (maximum speed) for excess pollutants and humidity (parties, odors, smoke, etc.) b) To turn the unit off, place selector at the OFF position. However, if optional auxiliary controls are used, they will still be active. B MORE HUMID HUMIDITY CONTROL LESS HUMID -30 C -22 F ZONE COMFORT 20% 25% -20 C -4 F 5 C+ 41 F+ -5 C 23 F 30% COM 40% FORT OFF DURING FALL, WINTER AND SPRING, SET THE DIAL ACCORDING TO THE DESIRED MAXIMUM INDOOR HUMIDITY LEVEL. DURING SUMMER SET THE DIAL TO THE OFF POSITION. Z ON E 50% MIN. OFF 60% 70% MAX. A Adjusting the HUMIDITY CONTROL: Setting during the summer months: VC0039 Normally, there is no condensation on your windows during this period which, therefore, eliminates the need of the humidity control. Set the slide switch A to OFF position during this period (do not exchange in day time, exchange at night time if cool outside or if it is not raining). Setting during the fall, winter and spring months: METHOD 1 (fast and simple for new users): a) Determine approximately the outside daytime temperature. b) Set knob B to this temperature. NOTE: Continue using this method for about a month before trying Method 2 suggested below. METHOD 2 (more precise adjustment): Use METHOD 2 (steps a to f below) if there is condensation on your windows after using METHOD 1 for at least 1 month. As ventilation needs vary from one house to another (depending on cooking habits, frequency of showers, washing, window design, etc.), an adjustment based on outside temperature may not adequately solve the condensation problem in your house. a) Select speed MIN. b) Turn knob B clockwise until you hear a click. c) Turn knob B a notch below the click. d) 12 to 24 hours later, check if there is still condensation on the windows. e) If there is, repeat steps b, c, d above (until desired results are obtained). f) Compare the two values: the one obtained with METHOD 1 and the other with METHOD 2. Use the variance for future reference. For example, if there is a 3-degree variance, you can conclude that, for your house, an adjusment of 3 degrees below the outside temperature is required for optimum condensation control. Do not select a temperature below -20 C. This could lead to excessive dryness in the air causing discomfort for the occupants. It is possible (and normal) to experience condensation on your windows when drastic changes in temperature occur (e.g.: -5 C [23 F] to -20 C [-4 F]). In that case, we suggest waiting a few days to allow the situation to stabilize. 5

3. CONTROLS (CONT D) 3.3 OPTIONAL AUXILIARY CONTROLS 3.3.1 Humidity Control Location: Purpose: Located in the bathroom or in other locations where there is temporary humidity excess. To eliminate excess humidity produced by showers or other periodic activities producing humidity. HUMIDITY CONTROL 20% 25% % RELATIVE HUM IDITY OFF 70% Adjust knob to the desired humidity level. Do not select a humidity level below 30%. This could lead to excessive dryness in the air causing discomfort for the occupants. 30% COM DURING FALL, WINTER AND SPRING, SET THE DIAL ACCORDING TO THE DESIRED MAXIMUM INDOOR HUMIDITY LEVEL. DURING SUMMER SET THE DIAL TO THE OFF POSITION. 40% FORT Z ON E 60% 50% VC0038 3.3.2 20-Minute Lighted Push Button Location: Purpose: Located in the bathroom or in other locations where there is temporary humidity excess or pollutants. To eliminate excess humidity produced by showers or other periodic activities producing pollutants. Press once to activate the push-button. The unit will operate on high speed for 20 minutes and the indicator will light up. To stop activation before the end of the 20-minute cycle, push one more time. The unit will get back to its previous setting. ON VENTILATION VC0040 3.3.3 60-Minute Crank timer Location: Purpose: Located in the bathroom or in other locations where there is temporary humidity excess or pollutants. To eliminate excess humidity produced by showers or other periodic activities producing pollutants. 50 HOLD 60 OFF 10 Turn Past 20 This control makes the system operate at high speed for periods varying from 10 to 60 minutes. 40 MINUTES 30 VC0017 6

4. MAINTENANCE! WARNING In order to prevent personal injury, turn off the unit and unplug it before performing maintenance. When cleaning the unit, it is recommended to wear safety glasses and gloves. 4.1 REGULAR Air filters: The air filters are washable. Under normal conditions, we recommend to wash them every 3 months. Use a vacuum cleaner to remove the heaviest portion of accumulated dust. Then, wash in water and mild soap. Let dry completely before reinstalling them in the unit. Heat Recovery Core: Hot water and a strong detergent will damage the heat recovery core. The heat recovery core must be handled with care. We recommend to wash it once a year, at the end of summer, in order to ensure maximum efficiency of the plastic partitions. Allow the heat recovery core to soak for 3 hours in a solution of warm water and mild soap. Rinse under a heavy stream of water. Let dry completely before reinstalling it in the unit. NOTE: When plugging back the unit, it will return to its previous setting after a 30-second delay for boot sequence. Intake hood: Regularly check the screen in the exterior intake hood and clean when necessary. Also check during very cold weather because ice may build up on the screen located in the exterior intake hood. Motor: The motor is factory lubricated for life. Do not oil bushings. 4.2 PROLONGED Annual service should include: Cleaning filters, heat recovery core and the exterior intake hood. Cleaning the blades of the blower wheels. Cleaning the condensation tray with soapy water (make sure that the drain is not clogged). NOTE: Ask your installer for an annual service contract. 7

5. TROUBLESHOOTING If you think your unit is malfunctioning, check some of the following: TYPE OF PROBLEM TRY THIS... 1 Nothing works. See if the unit is plugged in. See if the breaker is receiving power from the house circuit breaker. 2 Condensation on windows Adjust the humidity control knob as per instructions (see Section 3.). (air too humid). Operate the unit at maximum speed (MAX.) during activities generating excess humidity (family gatherings, extra cooking, etc.) Leave curtains half-open to allow air circulation. Store all firewood in a closed room with a dehumidifier or in a well ventilated room or store the wood outside. Do not adjust the thermostat of your heating system below 18 C (64 F). 3 Air too dry. Do not adjust your humidity control below -20 C (-4 F). Operate the unit at low speed (MIN). or in intermittent mode (with Lite-Touch Bronze). Temporarily use a humidifier. 4 Air too cold at the air Make sure the stale air exhaust hood outside the house is not blocked. supply grille. Operate the unit at low speed (MIN.) or in intermittent mode (with Lite-Touch Bronze). Have the system s balancing checked. Have the unit s defrosting system checked. Install a duct heater. 5 The LED of the integrated control is blinking red. There is a problem with the motor. The unit is OFF. Contact your installer. 6 The LED on the integrated There is a problem with the thermistor. The unit is still working, but is always in defrost control is blinking green. mode. Contact your installer. 7 The LED on the integrated There is a problem with the motorized damper. The unit is OFF. For a 12-hour period, control is blinking amber. the unit will try to reset the damper at every 20 to 30 minutes. After 12 hours, if the problem is not solved, the unit stops trying to reset damper. Contact your installer. 8 The integrated control push button does not work. The 30-second boot sequence is not completed. See integrated control on page 4. If the problem continues, contact your installer at the phone number and address listed below or call the following number for authorized service center nearest you: 1-800-567-3855 (CANADA AND U.S.A.) YOUR INSTALLER S ADDRESS REPLACEMENT PARTS AND REPAIR In order to ensure your ventilation unit remains in good working condition, you must use vänee genuine replacement parts only. The vänee genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing. Also, vänee recommends to contact a certified service depot for all replacement parts and repairs. 8