SUNLINE 2000 SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS DESCRIPTION FEATURES

Similar documents
SUNLINE 2000 ELECTRIC / ELECTRIC SINGLE PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTION Supersedes: N7Y (993) 530.

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(HE, HG) 036, 048 & YTG-A-0506

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

MODELS B1PA024, 030 AND 036

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

MODELS B3CH 048 AND 060 (WORLD 50 HZ)

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

MODELS B3CH 090 & 120A25, A46 MODELS B4CH090 & 120A58 (9 EER) 208/230/575 VOLT MODELS ONLY 208/230/460 VOLT MODELS ONLY

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

INSTALLATION MANUAL SUNLINE 2000 SINGLE PACKAGE HEAT PUMP BCH 036, 048 & 060

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Supersedes: N2W (398) N2Z (1298) MODELS BCCB 090 & 120, MODELS BECB090 & 120 (9 EER) 208/230/460 VOLT MODELS ONLY

FLEXIBLE LIGHT COMMERCIAL UNIT TECHNICAL GUIDE CHAMPION PLUS SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 3 AND 4 NOMINAL TON GENERAL

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Supersedes: N2Y (498) N2Y (799) MODELS B1HH018 THRU THRU 5 TON (12 SEER)

FLEXIBLE LIGHT COMMERCIAL UNIT TECHNICAL GUIDE AFFINITY SERIES SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 3 THROUGH 5 NOMINAL TON GENERAL

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

48TF GAS HEATING/ ELECTRIC COOLING UNITS

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DF NOMINAL TONS 10.4 EER YTG-F-0109

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

48PGD/E/F/L/M/N PG20-28

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

R-410A LUXAIRE ACCLIMATE DYX MODELS 2-4 TON 60 Hertz

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

RGE 13 A T - 1 A

INSTALLATION MANUAL AFFINITY SERIES SINGLE PACKAGE AIR CONDITIONERS ELECTRIC/ELECTRIC, AIR-COOLED. MODELS: D1EB036 thru Thru 5 Ton (10 SEER)

50TM TFF COMBINATION HEATING/COOLING UNITS

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Model 655A Sizes

50TM COMBINATION HEATING/COOLING UNITS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

R-410A AFFINITY SERIES DEX DEY Ton

48TM GAS HEATING/ELECTRIC COOLING UNITS

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

INSTALLATION MANUAL SUNLINE 2000 SINGLE PACKAGE HEAT PUMP BP

TECHNICAL SPECIFICATIONS

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

PAR5. Product Specifications

HEAT EXCHANGER Aluminized serpentine clamshell heat exchanger provides corrosion resistance for longer life and efficient heat transfer.

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

PACKAGE AIR CONDITIONER

TECHNICAL SPECIFICATIONS

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Supersedes: N1Y (1099) N1Y (0500) MODELS B1HA018 THRU THRU 5 TON (10 SEER)

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

INSTALLATION MANUAL SUNLINE GAS/ELECTRIC SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & 072 D(HE, HG) 036, 048 & 060

13 GEP A L P - 1 A

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

Supersedes: A-0202 MODELS B1HA018 THRU THRU 5 TON (10 SEER)

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

SUNLINE PLUS GAS / ELECTRIC SINGLE PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTION Supersedes: A A-0204

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

SUNLINE SERIES SINGLE PACKAGE AIR CONDITIONERS. INSTALLATION INSTRUCTION Supersedes: Nothing N3Y (394) MODELS D*SC360 & 480 INSPECTION

SUNLINE 2000 GAS / ELECTRIC SINGLE PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTION Supersedes: N6Y (593) 530.

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

High Heat COP. High/Low Stage

SUNLINE BP 180 SUNLINE MAGNUM - BP 240

Commercial High-Efficiency Condensing Units

SKYPAK II, 3 Ton Series, gives you a

ELECTRIC / ELECTRIC & GAS / ELECTRIC SINGLE PACKAGE AIR CONDITIONERS INSTRUCTION. Supersedes: N11W (1095) N11W(399)

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

Ruud Commercial Achiever Series Package Gas Electric Unit

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

INSTALLATION INSTRUCTION Supersedes: N11Y (195) N11Y (399)

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

4YCC3048A3096A /3/ /

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

SUNLINE 2000 GAS / ELECTRIC SINGLE PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTION Supersedes: N2YI (1096)/ A-0204

SKYPAK II Heating & Cooling Self Contained Packages

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

Product Data. Features/Benefits. 50LJQ Single-Package Rooftop Heat Pump Units. Nominal 3 to 10 Tons

INSTALLATION MANUAL SINGLE PACKAGE HEAT PUMP. MODELS: BA-15 and BA-20. ASHRAE 90.1 Compliant. Model BA-15. Model BA-20

13 SEER PACKAGE GAS / ELECTRIC UNIT (575V -3 Ph -60Hz) 36 to 61 MBtuh

Transcription:

50.TGY (95) SINGLE PACKAGE COOLED CONDITIONERS DCE 0, 0, 00 & DCE 07 0, 0, 00 & 07, AND 5 NOMINAL TONS (0 SEER) AND NOMINAL TONS (9 EER) SHOWN SUNLINE 000 DESCRIPTION YORK Sunline 000 units are convertible single package air conditioners with a common cabinet and a common roof curb for the,, 5 and ton sizes. The units were designed for residential, light commercial and commercial applications. They can easily be installed on a roof curb, slab, roof jack or frame. All units are selfcontained and assembled on rigid full perimeter base rails with fork lift slots on three sides and holes for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to provide for a quick and easy field installation. The units are available in cooling only, and cooling with gas heat. Electric heaters are available as fieldinstalled accessories. The cabinet is constructed of galvanized steel, painted with long lasting, durable, and aesthetically pleasing power paint. Paint finish meets 7 hour salt spray tests per ASTMB7 standards. All models include a 5year limited warranty on compressors and electric heating elements, a 0year limited warranty on gasfired heat exchangers and a year limited warranty on all replacement parts. FEATURES COMMON FOOTPRINT/COMMON CABINET All model sizes and configurations share a common cabinet and a common roof curb. The installer has the flexibility of setting one curb and placing the proper tonnage unit on that curb after the internal load has been determined. He can even decide between gas or electric heat after the curb has been set. HIGH EFFICIENCY All units have a high cooling efficiency, and gas / electric models have a minimum AFUE of 0%. All efficiencies exceed legislated minimum levels and provide low operating costs. CONVERTIBLE FLOW DESIGN Both the side and bottom duct openings are covered when they leave the factory. If a side supply / side return is desired, you simply remove the two side duct covers from the outside of the unit and discard them. If a bottom supply / bottom return is desired, you simply remove the two knockout panels from the base of the unit and discard them. No panel cutting or swapping is required! Convertible airflow design allows maximum field flexibility and minimum inventory. Economizers may be used on either bottom and side duct applications with no modifications required. FACTORYINSTALLED OPTIONS Economizers can be installed at the factory. The economizers are shipped installed and wired. Only the rain hood needs to be field assembled and installed. Field labor dollars can be saved by having the components arrive already installed. Adjustable belt drive blowers are available on most models from the factory for complete airflow flexibility. FIELDINSTALLED ACCESSORIES Accessories were designed for quick and easy installation. The motorized damper and economizers simply slide in, and electrical connections are made by modular plugs. Electric heaters mount easily, and knockouts are provided in the internal partitions to connect the elements to the control box single point kit. The " high roof curb is shipped knocked down. An insulated deck is not required because the bottom of the unit is insulated. Low ambient controls are available to provide stable unit operation at outdoor temperatures down to 0 F. Propane, high altitude and low NOx kits are also available to cover all gas heating applications. WIDE RANGE OF INDOOR FLOWS All, and 5ton models operate over a wide range of design conditions with a speed directdrive fan motor. The ton unit has a single speed directdrive fan motor. Beltdrive blowers are also available on all, and 5ton models and on ton, phase models. FULL PERIMETER BASE RAILS The permanently attached base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails provide fork lift access from sides, and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. Cont d.

50.TGY FEATURES CONT D. SYSTEM PROTECTION Crankcase heat and internal overload protection are standard on all compressors. Every unit has a liquid line filterdrier, high and low pressure/lose at charge switches and a suction line freezestat to protect all system components. All units will provide cooling at ambient temperatures down to F. UTILITY CONNECTIONS MADE EASY Gas and electric utility knockouts are provided in the unit base as well as the side of the unit. A clearly identified location is provided to mount a field supplied electrical disconnect switch. Utility connections can be made quickly and with a minimum amount of field labor. SIMPLE CONTROL CIRCUIT A low voltage printed circuit board contains a compressor lockout indicator light and a low voltage terminal strip. An additional set of pin connectors is also provided to simplify the field interface of external controls. Matenlock plug connectors are used where line and low voltage wires pass thru internal bulkheads. This allows for easier troubleshooting and component replacement. The electrical control box is not located in the compressor compartment so the access cover can be removed for troubleshooting without affecting the normal system operating pressures. All wiring internal to the unit is color/number coded. FILTERS Units are shipped with " disposable filters. The unit filter racks can accommodate " or " filters without any modifications. SUNLINE 000 LOW VOLTAGE RELAY BOARD AND TERMINAL STRIP ELECTRICAL DISCONNECT MOUNTING LOCATION (Field Installed) 0 GAUGE ALUMINIZED STEEL TUBULAR HEAT EXCHANGER DIRECT DRIVE BLOWER MOTOR (Belt Drive Option also available on some models) ELECTRIC HEAT ACCESSORY LOCATION (Elec/Elec Units) POWER VENTER MOTOR COPPER TUBE / ALUMINUM FIN CONDENSER COIL ECONOMIZER HOOD OUTDOOR OPENING FOR SLIDEIN/PLUG IN INTERNAL ECONOMIZER (OPTION/ A CCESSORY) HIGH EFFICIENCY COMPRESSORS WITH CRANKCASE HEAT SIDE RETURN DUCT OPENING (Return Air & Supply Air Side by Side) BASE RAILS WITH FORKLIFT SLOTS AND LIFTING HOLES BOTTOM RETURN DUCT OPENING (Return Air & Supply Air Side by Side) KNOCKOUT FOR SIDE GAS ENTRY /" PVC FEMALE CONDENSATE DRAIN KNOCKOUTS FOR SIDE POWER AND CONTROL ENTRY TERMINAL BLOCK (For Single Point Power Supply on Elec/Elec Units) KNOCKOUT FOR BOTTOM GAS ENTRY KNOCKOUT FOR BOTTOM POWER ENTRY (Gas Heating) Description... Features... Ratings... Physical Data... Component Weights... Cooling Capacities Ton... Cooling Capacities Ton...5 Cooling Capacities 5 Ton... Cooling Capacities Ton...7 Blower Performance & Ton w/beltdrive... Blower Performance 5 & Ton w/beltdrive...9 Blower Performance Ton w/directdrive...0 TABLE OF CONTENTS Option and Accessories...0 Static Resistances... Motor and Drive Data... Electrical Data Basic Units... Elec. DataClg./Elec. Htg. & Ton w/directdrive... Elec. DataClg./Elec. Htg. 5 & w/directdrive... Elec. DataClg./Elec. Htg. & w/beltdrive... Elec. DataClg./Elec. Htg. 5 & w/beltdrive...5 Field Wiring... Unit Dimensions...7 Roof Curb Dimensions...9 Typical Applications...0 Unitary Products Group

RATINGS CAPACITY RATINGS Cooling / Electric Heating ARI RATINGS NOMINAL COOLING CAPACITY SOUND ELECTRIC HEAT CAPACITY 0 / 795 F RATING (KW) MBH SEER EER (bels) V V 00V DCE0 0.0 9.0. 5, 7, 0, 7, 0, 0, 5 & 0 5 & 0 5 & 0 DCE0 0. 9.. 5, 7, 0, 7, 0, 0, 5 & 0 5 & 0 5 & 0 DCE00 59 0.5 9.. 5, 7, 0, 7, 0, 5 0, 5, 5, 0 & 0 0 & 0 0 & 0 DCE07 7 9.00. 5, 7, 0, 7, 0, 5, 0, 5, 5, 0 & 0 0 & 0 0 & 0 CAPACITY RATINGS Cooling / Gas Heating 0N0 0N079 0N00 0N099 00N079 00N099 07N079 07N099 ARI RATINGS COOLING CAPACITY 0 / 795 F MBH SEER EER 0.0 9.0 0.0 9.0 0. 9. 0. 9. 59 0.5 9. 59 0.5 9. 7 9.00 7 9.00 SOUND RATING (bels)........ INPUT (MBH) 00 75 5 00 5 00 5 OUTPUT (MBH) 79 59 99 79 99 79 99 GAS HEAT CAPACITY AFUE (%) 0.9 0.5 0.9 0. 0.5 0. 0.5 0. S.S.E. (%). 0.. 0. 0. 0. 0. 0. S.E. (%) 75.9 7. 77. 77.9 7. 77.9 7. 77.9 TEMP. RISE ( F) 5 555 75 555 5 555 5 GAS LINE SIZE (in. OD) / / / / / / / / Ratings are in accordance with ARI Standard 0. Sound ratings are in accordance with ARI Standard. Heaters are available as accessories all with single point power supply. SEER = Seasonal Energy Efficiency Ratio the total cooling output in BTU s during a normal annual usage period for cooling divided by the total electric power input in watthours during the same period. EER = Energy Efficiency Ratio the cooling capacity in Btu s per hour (Btuh) divided by the power input in watts at any given set of rating conditions, expressed in BTUH per watt (BTUH/watt). AFUE = Annual Fuel Utilization Efficiency determined in accordance with DOE test procedure. S.S.E. = Steady State Efficiency. (Percent Output). S.E. = California Seasonal Efficiency determined in accordance with test procedures as specified by the State of California Energy Commission. Furnaces are available with a low NOx accessory. = Not ARI Listed. PHYSICAL DATA BASIC UNITS EVAPORATOR BLOWER EVAPORATOR COIL CONDENSER FAN CONDENSER COIL FILTERS (SEE NOTE) Basic Unit Options and Accessories NOTE: Weights are given in pounds. S CENTRIFUGAL BLOWER (Dia. x Wd. in.) FAN MOTOR HP (DIRECTDRIVE) FAN MOTOR HP (BELTDRIVE) ROWS DEEP FINS PER INCH FACE AREA (Sq. Ft.) PROPELLER DIA. (in.) FAN MOTOR HP NOM. TOTAL ROWS DEEP FINS PER INCH FACE AREA (Sq. Ft.) QUANTITY PER UNIT (" X 0" X ") QUANTITY PER UNIT (" X 5" X ") TOTAL FACE AREA (sq. ft.) DCE/ 0 0 00 07 x 0 x 0 x 0 x / /.5.5.5 COMPONENT S DCE & TON TON 5 TON TON DCE (Cooling only) 5 55 0 Mbh 05 (Gas / Electric) 0 Mbh 79 Mbh 5 75 99 Mbh 55 0 7 Economizer Motorized Outdoor Air Damper Electric Heat 5 7 KW (Nominal KW) 0 5 KW (DCE only) 0 0 KW Roof Mounting Curb 9 Relief / Fixed Air Damper 0 BeltDrive Blower 5. /,0 7.. /,00 9 7. 5. /,0.... CHARGE REFRIGERANT (lbs./oz.) /0 / 7/ 0/ NOTE: Filter racks are adapted for " or " thick filters. COMPONENT WEIGHTS 7. 50.TGY Unitary Products Group 5. /,0.7

50.TGY COOLING CAPACITIES TON (DCE / 0) Air On Temperature of Air on Condenser Coil Evaporator 5 F 95 F Coil Sensible Capacity, MBH Sensible Capacity, MBH WB Cap. Input Entering Dry Bulb, F Cap. Input Entering Dry Bulb, F F MBH KW 0 77 7 7 MBH KW 0 77 7 7 7 9. 7.7 7 7 7 7. 7. 9 0 5. 0 5. 9 7 57. 0 5. 7 7. 9 5. 9 5 0 7. 7 9 5.5 9 7 0. 9.5 9 9 0 57. 7 9 9. 9 9 9 7 7 7.. 7 0 0 7. 9 5.5 7 0 7 9. 9 9. 9 9 7 0 57. 7 0. 7 7. 9 5 9. 5 9 00 7. 9 0.5 9. 9 9 9. 7 57 9. 9 9 7 7. 5 7. 0.5 0 7 0 7. 0 7 9. 9 0 7 7. 7 0 7. 9 0 57 7.0 7 7 9. 9 7 7. 9 9. 9 0 7 9. 0 7 5 0. 9 9 7.0 0 5 0. 9 7 9 57.0 9 7. 0 7 5 0 Air On Temperature of Air on Condenser Coil Evaporator 05 F 5 F Coil Sensible Capacity, MBH Sensible Capacity, MBH WB Cap. Input Entering Dry Bulb, F Cap. Input Entering Dry Bulb, F F MBH KW 0 77 7 7 MBH KW 0 77 7 7 7.0 0. 9 5 0 7 7.9 7 7 9 0 7. 9.9 7 9 0. 0 7 57. 7 9 0.0 0 7 7.9 7 0. 0 0 7 9. 0.0 9 5 7. 0.0 9 5 57.7 0.9 9 5 9 7.9 0 9. 9 5 0 7 9. 9 5.0 7.7 7 0.0 9 5 57.7 0.9 9 5 7.9 7 7 9. 9 00 7 7. 0 7 0 7.0 0 9 5 9.7 9 5 9.0 0 0 7 57.7 9 9.9 0 0 7 7 9. 5 9 7.0 5 0 7.7 0 7 5 9.9 9 0 5. 9 7 0.9 0 0 7 9 57. 0 7 0. 0 0 7 9 7 7.7 0 5.0 9 0 7.7 7 5 0 5.9 9. 9 7 5 0 7 9. 9 7 5 0 7 5 57.5 0 7 5 0 7 9. 9 7 5 0 7 5 These capacities are gross ratings. For net capacity, determine the KW of the supply air blower motor from the Blower Performance Table, multiply this value by. MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0. KW. Refer to the Blower Performance Table for the KW of the supply air blower motor. NOMINAL RATING ALL SENSIBLE CAPACITY Unitary Products Group

COOLING CAPACITIES TON (DCE / 0) 50.TGY Air On Temperature of Air on Condenser Coil Evaporator 5 F 95 F Coil Sensible Capacity, MBH Sensible Capacity, MBH WB Cap. Input Entering Dry Bulb, F Cap. Input Entering Dry Bulb, F F MBH KW 0 77 7 7 MBH KW 0 77 7 7 7 5. 7 57 5. 7 000 7 55.0 7 7 5 5. 7 5.0 5 5 0 5. 7 7 57 5.9 5 5 9 9 5. 9 9 9 7 7 57. 0 5 55.5 9 0 5 00 7 5.0 9 0 5. 7 9 9 5.9 9 9. 7 7 57.9 9 0. 7 7 7 5.0 7 9 5. 7 00 7 5.9 7 9 5 5. 7. 9 7 9. 57.. 7 7 5.0 0 5. 0 0 7.9 7. 0 7 7. 7 0 7. 0 57 7. 7 7 9. 9 7 7 5.9 0 7 0. 00 7.9. 5.. 9 9 5 57.7 0.0 9 9 Air On Temperature of Air on Condenser Coil Evaporator 05 F 5 F Coil Sensible Capacity, MBH Sensible Capacity, MBH WB Cap. Input Entering Dry Bulb, F Cap. Input Entering Dry Bulb, F F MBH KW 0 77 7 7 MBH KW 0 77 7 7 7 5.7 5 5. 0 5 000 7 9. 0.9 9 9. 9 9.9 0 5 0 57.5 9 9. 0 5 0 7 5.7 9 5. 7 00 7..9 7.5 9.9 9 0 57.5 9. 0 7 5. 7 9 5.0 00 7 7.5 7. 0 5. 9 5. 9 0 57. 9 5.7 9 0 7 9.5 9 5 5.0 7 0 0 7.5 9 5. 7 9. 7.7 7 0 57. 7 7.7 7 7 7 0 7. 9 9.9 7 7 00 7. 9 9.7 0 7 0 7 9. 9 7 5. 57. 5. These capacities are gross ratings. For net capacity, determine the KW of the supply air blower motor from the Blower Performance Table, multiply this value by. MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0. KW. Refer to the Blower Performance Table for the KW of the supply air blower motor. NOMINAL RATING ALL SENSIBLE CAPACITY Unitary Products Group 5

50.TGY COOLING CAPACITIES 5 TON (DCE / 00) Air On Temperature of Air on Condenser Coil Evaporator 5 F 95 F Coil Sensible Capacity, MBH Sensible Capacity, MBH WB Cap. Input Entering Dry Bulb, F Cap. Input Entering Dry Bulb, F F MBH KW 0 77 7 7 MBH KW 0 77 7 7 7 5.0 5 9 5. 5 0 7.9 59 57 5 5 5. 57 5 5.9 0 5 5. 5 57 55 5 9 57. 0 5 9 59 5. 59 59 5 5 9 7 9.9 9 0 7 5. 9 7 7 5.9 5 55 9 0 5. 55 5 0. 59 5 7 59 5. 59 5 5 5 9 57. 59 5 7 5 5. 5 5 55 5 9 7.9 9 5. 9 000 7. 57 5 0 5. 55 5 0 0.7 0 0 5 5 5 5. 5 5 5 9 57 0.7 0 0 5 5 7 5 5.0 5 5 5 9 7. 7 7 5. 9 7 7. 5 0 5. 5 9 9 0 59.7 59 5 5 7 5 5.0 5 5 5 9 9 57 5.7 5 5 5 55 5.0 55 55 5 9 9 7. 0 5. 0 7. 7 5 5. 5 7 0 57.7 5 5 5 5.0 5 5 7 9 57 5. 5 5 7 5.9 5 5 5 7 9 Air On Temperature of Air on Condenser Coil Evaporator 05 F 5 F Coil Sensible Capacity, MBH Sensible Capacity, MBH WB Cap. Input Entering Dry Bulb, F Cap. Input Entering Dry Bulb, F F MBH KW 0 77 7 7 MBH KW 0 77 7 7 7 5. 0. 7 0 7 0 5. 5 5 0 5 5.9 7 55 5.5 55 55 5 7 7 5. 9 57 5 5.5 5 5 5 7 7 5. 7 9 7 5.7 0 59. 9 7 59 5. 5 5 7 9 5 5.9 9 7 5 5.5 5 5 5 5. 7 0 57 5 5. 5 5 5 9 7 5.7 7 7 0 7 5.7 9 5. 7 000 7 57 5.5 9 5 5. 7 5 5. 5 5 0 7 5.7 7 57 5 5. 5 5 5 0 5.7 7 7 0 5. 7 55.0 0 5 7 7 55 5.5 7 7 9 5. 9 9 5 5. 5 9 9 0 5.7 57 5. 9 9 0 5. 9 9 7 57 5.5 0 5 5 5.9 7 0 7 5 5. 9 0 7 5.7 9 9 5. 9 7 7 9 5. 9 0 57 5. 7 5.5 9 7 These capacities are gross ratings. For net capacity, determine the KW of the supply air blower motor from the Blower Performance Table, multiply this value by. MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.7 KW. Refer to the Blower Performance Table for the KW of the supply air blower motor. NOMINAL RATING ALL SENSIBLE CAPACITY Unitary Products Group

COOLING CAPACITIES TON (DCE / 07) 50.TGY Air On Temperature of Air on Condenser Coil Evaporator 5 F 95 F Coil Sensible Capacity, MBH Sensible Capacity, MBH WB Cap. Input Entering Dry Bulb, F Cap. Input Entering Dry Bulb, F F MBH KW 0 77 7 7 MBH KW 0 77 7 7 7 9. 5 9.7 5 7 7. 75 0 5 7 77. 9 7 59 75.0 75 7 7 5 9. 7 5 9 57 7 5.9 7 7 7 7 0 5. 55 7 7 5. 0 5 7 0. 59 5 0 7 79.0 7 5 5 5 75. 57 9 7 5.9 7 7 9 55 5. 5 5 5 0 5 7 57 9 5. 9 9 9 5 5 5. 5 7. 57 7 7. 55 00 7 7.0 9 55 9 7. 5 7 9 5. 9 7 0 5 7. 57 7 57 5.7 5 9.0 59 5 7 79. 5 7.5 5 9 00 7 7 5.9 5 5. 57 5.7 5 57 5 9. 0 5 7 57 5. 0 5 0.0 0 0 0 55 9 7 7 7. 7 7.5 7 0 7 7 5.9 59 5 7. 57 5 0 5.7 57 5 7 5. 5 5 5 9 57 5.5 0 55 9 57.0 57 57 5 9 Air On Temperature of Air on Condenser Coil Evaporator 05 F 5 F Coil Sensible Capacity, MBH Sensible Capacity, MBH WB Cap. Input Entering Dry Bulb, F Cap. Input Entering Dry Bulb, F F MBH KW 0 77 7 7 MBH KW 0 77 7 7 7 7 7. 5 7 7 7. 0 5 7 7.9 57 9 7. 55 7 9. 5.9 5 9 57. 5.9 55 0 7 7 7. 5 5 7 7. 5 0 7 9.9 55 7. 5. 5 5 59. 59 59 59 5 0 57. 59 5 59. 59 59 59 5 9 7 7 7.0 5 9 7. 7 00 7.7 5 5 7. 5 55 0 0. 0 0 0 5 7 5. 5 5 5 7 57 0. 0 0 0 55 5. 5 5 5 9 7 0 7 7 7.0 9 7 7 7. 7 0 00 7.7 5 5 7 5 7. 5 5 9 5. 5 5 5 5.7 5 5 5 9 57 5. 5 5 5 5 9 5.7 5 5 5 9 7. 9 9 7. 7 7 0 7. 5 5 7.0 7 5 5. 5 5 5 0 9.7 9 9 7 57 5. 5 5 5 7 9. 9 9 7 These capacities are gross ratings. For net capacity, determine the KW of the supply air blower motor from the Blower Performance Table, multiply this value by. MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.5 KW. Refer to the Blower Performance Table for the KW of the supply air blower motor. NOMINAL RATING ALL SENSIBLE CAPACITY Unitary Products Group 7

50.TGY BLOWER PERFORMANCE 0 & 0 with BeltDrive 0 SIDE DUCT APPLICATIONS (0//575 VOLTS) 0 FLOW Available External Static Pressure IWG* 0.0 0.0 0. 0. 0.0 0. 0.0 RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 0 5 0 7 9 795 99 0 0 9 00 55 5 95 9 7 9 7 9 09 0 0 7 0 7 7 5 97 70 775 00 5 0 5 0 79 595 9 0 9 975 75 0 7 00 5 7 75 95 75 995 7 00 55 0 97 5 9 5 00 09 5 55 5 0 5 9 5 000 7 9 5 7 5 99 5 0 797 0 5 50 FLOW Available External Static Pressure IWG* 0..00.0.0.0.. RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 0 00 0 0 055 75 0 00 0 0 00 0 7 07 75 075 00 00 97 0 00 7 0 775 000 9 55 005 0 0 95 0 75 09 7 0 9 5 00 0 0 05 0 0 NOTE: FOR 0 VOLTS, MULTIPLY VALUES BY 0.95. *INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, " FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT FLOWS. 0 SIDE DUCT APPLICATIONS (0//575 VOLTS) 0 0 FLOW Available External Static Pressure IWG* 0.0 0.0 0. 0. 0.0 0. 0.0 RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 000 0 0 95 99 005 95 05 99 00 95 07 0 7 775 5 9 90 995 9 05 00 5 0 00 7 0 70 7 5 9 95 0 05 00 0 0 7 5 0 9 9 00 00 00 5 5 7 9 0 9 9 0 95 755 9 9 95 0 7 5 75 9 0 00 5 5 9 75 9 75 00 7 0 0 9 70 FLOW Available External Static Pressure IWG* 0..00.0.0.0.. RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 000 0 0 05 0 00 0 0 0 0 0 075 0 5 00 00 005 00 0 00 05 0 00 9 0 995 0 0 0 9 0 0 07 95 07 000 00 9 00 05 099 00 95 99 5 0 55 00 5 NOTE: FOR 0 VOLTS, MULTIPLY VALUES BY 0.95. *INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, " FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT FLOWS. Unitary Products Group

50.TGY BLOWER PERFORMANCE 00 & 07 with BeltDrive 00 SIDE DUCT APPLICATIONS (0//575 VOLTS) 00 FLOW Available External Static Pressure IWG* 0.0 0.0 0. 0. 0.0 0. 0.0 RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 0 059 50 077 5 095 0 0 5 5 0 0 5 05 07 55 09 50 595 0 7 00 005 0 0 75 09 09 0 75 5 5 00 0 00 0 0 0 0 7 00 90 00 957 0 9 00 00 00 09 0 0 0 09 000 77 9 975 9 000 97 00 009 0 0 00 0 5 0 9 5 9 9 0 00 07 095 00 55 5 0 9 5 9 9 0 9 0 5 95 9 0 00 00 7 05 9 97 0 7 9 95 0 FLOW Available External Static Pressure IWG* 0..00.0.0.0.. RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 0 0 9 5 00 50 0 0 00 0 50 00 55 75 00 000 00 5 9 05 0 079 0 0 0 7 0 75 00 05 00 0 5 9 95 0 0 07 00 0 00 75 97 05 00 00 0 05 95 0 0 05 05 0 9 0 00 0 0 0 0 95 0 0 0 5 075 0 NOTE: FOR 0 VOLTS, MULTIPLY VALUES BY 0.95. *INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, " FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT FLOWS. 07 SIDE DUCT APPLICATIONS (0//575 VOLTS) 07 FLOW Available External Static Pressure IWG* 0.0 0.0 0. 0. 0.0 0. 0.0 RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 00 55 000 00 00 9 0 57 5 5 5 0 00 0 0 07 0 9 0 05 075 7 0 00 95 05 75 0 5 075 0 0 75 70 5 0 90 95 00 9 00 0 05 0 0 00 00 5 0 9 0 95 0 997 0 5 00 000 99 05 9 00 9 0 0 0 00 9 95 99 005 9 00 FLOW Available External Static Pressure IWG* 0..00.0.0.0.. RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 00 000 00 07 00 9 9 00 0 75 7 70 05 00 5 00 0 0 55 5 7 9 775 000 0 75 077 00 09 75 0 05 5 00 00 99 0 0 00 05 00 07 075 7 0 NOTE: FOR 0 VOLTS, MULTIPLY VALUES BY 0.95. *INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, " FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT FLOWS. Unitary Products Group 9

50.TGY BLOWER PERFORMANCE 0, 0, 00, 07 with DirectDrive GAS HEAT @ 0//575 VOLTS Side Duct Applications 0 0 00 MOTOR SPEED HI MED LOW HI MED LOW HI MED LOW Available External Static Pressure IWG* 0.0 0.0 0. 0. 0.0 0. 0.0 0..00 Watts Watts Watts Watts Watts Watts Watts Watts Watts 7 99 0 0 00 9 75 70 55 05 00 00 99 5 9 0 7 7 0 5 05 9 7 09 FACTORYINSTALLED OPTIONS 5 7 5 7 795 75 75 5 095 00 9 ECONOMIZERS: Units equipped with a factoryinstalled economizer option have dampers that are positioned by a spring return, fully modulating damper actuator and are capable of introducing up to 00% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrigeration to economizer operation is determined by a single input electronic enthalpy control or by a dual input electronic enthalpy control. Simultaneous compressor and economizer operation is also possible. The single enthalpy system contains a sensor that monitors the outdoor air which automatically operates the damper actuator allowing the dampers to open or close. FIELDINSTALLED ACCESSORIES 7 07 95 SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZER Includes a slidein / plugin damper assembly with fully modulating spring return motor actuator capable of introducing up to 00% outdoor air, one outdoor air electronic enthalpy sensor and a rain hood with filters. The rain hood is painted to match the basic unit and must be fieldassembled before installation. Economizer dampers are % low leakage type. DUAL INPUT ELECTRONIC ENTHALPY ECONOMIZER Includes the same damper system and rain hood with filters as described for a single enthalpy economizer except this accessory contains two enthalpy sensors. It uses a differential enthalpy control that compares the outdoor air versus the return air. The logic module then optimizes the economizer operation for additional savings over the single input economizer. MOTORIZED DAMPER Includes slidein / plugin damper assembly with position springreturn motor actuator and a rain hood with permanenttype filters. The outdoor air dampers open when the indoor fan motor is energized. The rain hood is shipped knocked down and must be field assembled. BAROMETRIC RELIEF / FIXED OUTDOOR INTAKE DAMPER A dual function device that consists of a rain hood with a bird screen and a flexible damper. It provides either of the following: ) a fixed outdoor air intake on units less economizer or ) barometric relief or units with economizer. The rain hood is fully assembled, painted to match the basic unit and ready for installation. ELECTRIC HEATERS Include nickel chromium elements, a terminal block, fuses (where required by UL), all the necessary connectors and hardware. All heaters utilize single point power supply hookup. Capacities from 5 KW thru 0 KW heating are available. FUSE BLOCK KITS These kits have a fuse box with a fuse block and fuses. They re available for all 0 volt heaters and 0/00 volt heaters 7 KW and smaller. OUTDOOR THERMOSTAT A volt thermostat providing two stages of control for units equipped with electric heat accessories. ROOF CURB This " high full perimeter roof curb is shipped knocked down for field assembly and contains duct supports that can easily be 75 5 0 7 75 59 95 0 9 09 9 5 755 0 0 7 00 9 0 9 9 75 0 0 05 5 0 5 5 7 7 7 7 0 0 0 5 5 0 7 9 75 0 0 0 9 77 5 7 00 0 0 0 00 5 00 75 00 95 595 0 5 9 0 7 5 07 HI 95 0 7 05 0 0 000 05 9 55 0 0 *INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, " FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT FLOWS. NOTE: FOR 0 VOLTS, MULTIPLY VALUES BY 0.95. 55 5 5 7 5 575 55 79 The dual enthalpy system contains a second sensor that monitors both the temperature and the humidity of the return air in addition to the outdoor air sensor described for a single enthalpy system. The logic module compares the inputs from both sensors and switches to economizer operation whenever the outdoor air is cooler than the return air for maximum efficiency of the economizer system. The economizer is completely wired and installed at the factory. Only the outdoor air hood, including its filters, need be assembled and installed in the field. BELT DRIVE BLOWERS: Adjustable beltdrive blowers providing maximum flexibility to handle many airflow requirements, are available on all, and 5 ton models and on ton, phase models. shifted for the desired unit duct arrangement. No insulated deck is required because the unit underside is insulated. START ASSIST KIT Provides increased starting torque for single phase units in areas with low voltage conditions. It contains a.5 OHM PTCR temperature resistor with a support clip and hardware for mounting. LOW AMBIENT KIT A head pressure controller maintains stable system operation by reducing the speed of the condenser fan motor when the outdoor temperature is between and 0 F. Condenser fan motors with ball bearings and heavier windings are also available for these low ambient applications. ANTIRECYCLE TIMER A timer to prevent the unit compressor from short cycling. It assures a 5minute offtime between compressor cycles. PROPANE CONVERSION KIT Converts a gasfired heater from natural gas to propane. It contains main burner orifices, a pilot orifice and a regulator spring. LOW NOx KIT (natural gas furnaces only) Contains five stainless steel expanded metal sheets for mounting into the heat exchanger tubes to meet the California low nitrous oxide emission requirements. HIGH ALTITUDE CONVERSION (NATURAL AND PROPANE) Provides orifices for proper furnace operation at altitudes up to 000 feet. For propane applications, the propane conversion kit will also be required. GAS PIPING This kit contains /" pipe nipples, fittings and gas cock (including panel access gaskets) required for bottom gas supply connection with external shutoff. OUTDOOR COIL GUARD Consists of grilletype sections for installation over the outdoor coil to protect it from damage. WALL THERMOSTAT The units are designed to operate with volt electronic and electromechanical thermostats. All units can operate with single stage heat / single stage cool thermostats with or without the economizer. 0 Unitary Products Group

STATIC RESISTANCES EXTERNAL STATIC PRESSURE DROP RESISTANCE, IWG DESCRIPTION 000 00 0 00 00 000 00 0 00 00 000 Economizer/Motorized Damper, 0.07 0.0 0.09 0. 0. 0.5 0.7 0.0 0. 0. 0.0 Electric Heaters 5 5 KW 0.0 0.05 0.0 0.07 0.0 0.0 0. 0. 0. 0.9 0. 0 0 KW 0.0 0.07 0.0 0.09 0. 0. 0.5 0.7 0.0 0. 0. Bottom Duct Connections 0.0 0.07 0.0 0.09 0.0 0. 0. 0. 0. 0.9 0. Cooling Only 0.0 0.0 0. 0. 0. 0. 0.0 0. 0. 0.9 0. Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table. Add these resistance values to the available static resistance in the respective Blower Performance Table. The pressure thru the economizer is greater for 00% outdoor air than for 00% return air. If the resistance of the return air duct system is less than 0.5 IWG, the unit will deliver less during full economizer operation. MOTOR AND DRIVE DATA BeltDrive Blower ELECTRICAL DATA Basic Units with DirectDrive DCE 0 0 00 07 POWER 0/00 0/00 0 5750 0/00 0/00 0 5750 0/00 0/00 0 5750 0/00 0 5750 VOLTAGE LIMITATIONS (SEE NOTE ) COMPRESSOR MIN. RLA LRA 7 7 5 7 7 5 7 7 5 7 5 5 5 0 5 5 0 5 5 0 5 0 9.. 7. 5...7 7....7 9.. 0.7 0.0. 7 0 5 05 0 5 7 59 5 5 COND. FAN MOTOR, FLA............... BLOWER MOTOR, FLA.... 5.0 5.0......... TOTAL UNIT AMPACITY, 0.7..5 0.9. 5.7.5.. 9..7 5..0 5. FUSE SIZE, (SEE NOTE ) 5 5 5 5 5 0 5 0 NOTES:. Utilization Range A in accordance with ARI Standard 0.. Dual element, time delay type.. Based on 0 C copper conductors. DCE 0 0 00 07 POWER BLOWER RANGE (RPM) ELECTRICAL DATA Basic Units with BeltDrive 0/00 0/00 0 5750 0/00 0/00 0 5750 0/00 0/00 0 5750 0/00 0 5750 VOLTAGE LIMITATIONS (SEE NOTE ) COMPRESSOR MIN. RLA LRA 7 7 5 7 7 5 7 7 5 7 5 5 5 0 5 5 0 5 5 0 5 0 MOTOR* HP RPM FRAME SIZE 9.. 7. 5...7 7....7 9.. 0.7 0.0. 7 0 5 05 0 5 7 59 5 5 SERVICE FACTOR COND. FAN MOTOR, FLA............... ADJUSTABLE MOTOR PULLEY PITCH BORE DIA. (in.) (in.) BLOWER MOTOR, FLA 5. 5.... 5...0..0.0. 7..7. TOTAL UNIT AMPACITY,. 5... 9. 5.9.9.. 9....5 7..5 FIXED BLOWER PULLEY PITCH BORE DIA. (in.) (in.) FUSE SIZE, (SEE NOTE ) 0 5 5 5 5 0 5 0 NOTES:. Utilization Range A in accordance with ARI Standard 0.. Dual element, time delay type.. Based on 0 C copper conductors. HACR BREAKER SIZE, 5 5 5 5 HACR BREAKER SIZE, 0 5 5 5 BELT PITCH LENGTH (in.) 50.TGY DESIG NATION DCE / 0 0 00.. 5/.5. A DCE / 0 7 0 / 75 5.5.. 7/ 5.7 7. A DCE / 00 0 / 75 5.5.. 7/ 5. 7. A DCE / 07 0 / 75 5.5.. 7/ 5. 7. A *All motors have solid bases and are inherently protected. These motors can be selected to operate into their service factor because they are located in the moving air, upstream of any heating device. MIN. WIRE SIZE, AWG (SEE NOTE ) 0 0 0 0 0 MIN. WIRE SIZE, AWG (SEE NOTE ) 0 0 0 0 0 Unitary Products Group

50.TGY ELECTRICAL DATA Cooling / Electric Heating (DCE0 & 0) with DirectDrive DCE 0 0 POWER 00 00 00 00 0 5750 00 00 00 00 0 5750 HEATER ACCESSORY NUMBER CE0 CE0 CE00 CE0 CE00 CE0 CE0 CE00 CE0 CE00 CE055* CE075* CE05 CE05 CE05 CE055* CE075* CE05 CE05 CE05 CE07* CE0* CE0* CE0* CE05 CE05 CE05 CE0 CE0 CE00 CE0 CE00 CE0 CE0 CE00 CE0 CE00 CE055* CE075* CE05 CE05 CE05 CE055* CE075* CE05 CE05 CE05 CE07* CE0* CE0* CE0* CE05 CE05 CE05 BLOWER MOTOR FLA...... 5.0 5.0 5.0 5.0.. KW.0 5..0.9 5.9 5. 0. 5.9..0 5..0.9 5.9 5. 0. 5.9.. 0.. 9.5 0. 5.9..0 5..0.9 5.9 5. 0. 5.9..0 5..0.9 5.9 5. 0. 5.9.. 0.. 9.5 0. 5.9. ELECTRIC HEATERS STAGES TOTAL 9. 7.. 57. 7.....0..0 5.....7.0 5.5. 5.0....5 0. 5. 0. 9. 7.. 57. 7.......0 5.....7.0 5.5. 5.0....5 0. 5. 0. TOTAL UNIT AMPACITY 0.7 9. 5. 77. 0... 0.. 5.9. 5.0..9 0...0 7. 5. 9..0 7.9.. 5.5.9... 5. 7.0 0.0...5 9.. 5.7 5..9 7..5 5.7.. 5.0.0.0 7.9.. 5.5.9. FUSE SIZE 0 0 0 5 0 5 0 5 0 5 0 0 0 0 5 0 5 0 5 0 5 0 SIZE HACR BREAKER 0 0 0 5 0 5 0 5 0 0 0 5 0 5 0 5 MIN. WIRE SIZE AWG 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Dual element, time delay type Standard circuit breakers may be used in Canada and on applications over 0 amps where the heaters are separately fused. Based on 0 C copper conductors (up to 00 amps max. or 75 C copper conductors (00 amps and over) Electric Heat Correction Factors Nominal Voltage Voltage KW Cap Multipier 0 0.00 0 0.9 0.9 00 575 0.9 * These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code ((eg., Chicago), the following fuse block accessories are available for field installation. Fuse Block FB0 FB05 0/ Volts Volts Unitary Products Group

ELECTRICAL DATA Cooling / Electric Heating (DCE00 & 07) with DirectDrive DCE 00 07 POWER 00 00 00 00 0 5750 00 00 0 5750 HEATER ACCESSORY NUMBER CE0 CE0 CE00 CE0 CE00 CE000 CE0 CE0 CE00 CE0 CE00 CE000 CE055* CE075* CE05 CE05 CE05 CE005 CE055* CE075* CE05 CE05 CE05 CE005 CE07* CE0* CE0* CE0* CE00* CE05 CE05 CE05 CE005 CE055* CE075* CE05 CE05 CE05 CE005 CE055* CE075* CE05 CE05 CE05 CE005 CE07* CE0* CE0* CE0* CE00* CE05 CE05 CE05 CE005 BLOWER MOTOR FLA.......... KW.0 5..0.9 5.9. 5. 0. 5.9. 9..0 5..0.9 5.9. 5. 0. 5.9. 9.. 0.. 9.5. 0. 5.9. 0..0 5..0.9 5.9. 5. 0. 5.9. 9.. 0.. 9.5. 0. 5.9. 0. ELECTRIC HEATERS STAGES TOTAL 9. 7.. 57. 7. 0.9.......0 5.....7.7.0 5.5. 5.0 7.....5. 0. 5. 0. 9..0 5.....7.7.0 5.5. 5.0 7.....5. 0. 5. 0. 9. TOTAL UNIT AMPACITY.. 5. 0.0 0..9. 7..5 9... 9. 9..9 9..5 5. 9. 0.. 5.0 7.0 97..7 9...5 7..9. 9...0.0. 9.9.7 5..0.0. 5. 7. 9 9.7.9. 7. 7.. 0.0. FUSE SIZE 0 00 5 75 0 0 00 5 5 5 0 5 0 0 0 00 5 5 5 0 5 0 SIZE HACR BREAKER 0 00 5 75 0 0 00 5 5 5 0 0 00 5 5 5 50.TGY MIN. WIRE SIZE AWG 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 Dual element, time delay type Standard circuit breakers may be used in Canada and on applications over 0 amps where the heaters are separately fused. Based on 0 C copper conductors (up to 00 amps max. or 75 C copper conductors (00 amps and over) Electric Heat Correction Factors Nominal Voltage Voltage KW Cap Multipier 0 0.00 0 0.9 0.9 00 575 0.9 * These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code ((eg., Chicago), the following fuse block accessories are available for field installation. Fuse Block FB0 FB05 0/ Volts Volts Unitary Products Group

50.TGY ELECTRICAL DATA Cooling / Electric Heating (DCE0 & 0) with BeltDrive DCE 0 0 POWER 00 00 00 00 0 5750 00 00 00 00 0 5750 HEATER ACCESSORY NUMBER CE0 CE0 CE00 CE0 CE00 CE0 CE0 CE00 CE0 CE00 CE055* CE075* CE05 CE05 CE05 CE055* CE075* CE05 CE05 CE05 CE07* CE0* CE0* CE0* CE05 CE05 CE05 CE0 CE0 CE00 CE0 CE00 CE0 CE0 CE00 CE0 CE00 CE055* CE075* CE05 CE05 CE05 CE055* CE075* CE05 CE05 CE05 CE07* CE0* CE0* CE0* CE05 CE05 CE05 BLOWER MOTOR FLA 5. 5. 5. 5..... 5. 5...0 KW.0 5..0.9 5.9 5. 0. 5.9..0 5..0.9 5.9 5. 0. 5.9.. 0.. 9.5 0. 5.9..0 5..0.9 5.9 5. 0. 5.9..0 5..0.9 5.9 5. 0. 5.9.. 0.. 9.5 0. 5.9. ELECTRIC HEATERS STAGES TOTAL 9. 7.. 57. 7.....0..0 5.....7.0 5.5. 5.0....5 0. 5. 0. 9. 7.. 57. 7.......0 5.....7.0 5.5. 5.0....5 0. 5. 0. TOTAL UNIT AMPACITY..5 5.5 7. 0...7. 9. 7.0 5.....9 5. 9..5 5... 9.....0 9. 9.. 5..5 0. 9. 9..0 9.. 5.9.0. 7.9.7 5.9 9.. 5...5..7. 5...0 FUSE SIZE 0 0 0 5 0 0 0 0 5 0 5 0 0 0 0 00 5 0 0 5 0 5 0 5 0 SIZE HACR BREAKER 0 0 0 5 0 0 0 0 5 0 0 0 00 5 0 0 5 0 5 MIN. WIRE SIZE AWG 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Dual element, time delay type Standard circuit breakers may be used in Canada and on applications over 0 amps where the heaters are separately fused. Based on 0 C copper conductors (up to 00 amps max. or 75 C copper conductors (00 amps and over) Electric Heat Correction Factors Nominal Voltage Voltage KW Cap Multipier 0 0.00 0 0.9 0.9 00 575 0.9 * These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code ((eg., Chicago), the following fuse block accessories are available for field installation. Fuse Block FB0 FB05 0/ Volts Volts Unitary Products Group

ELECTRICAL DATA Cooling / Electric Heating (DCE00 & 07) with BeltDrive DCE 00 07 POWER 00 00 00 00 0 5750 00 00 0 5750 HEATER ACCESSORY NUMBER CE0 CE0 CE00 CE0 CE00 CE000 CE0 CE0 CE00 CE0 CE00 CE000 CE055* CE075* CE05 CE05 CE05 CE005 CE055* CE075* CE05 CE05 CE05 CE005 CE07* CE0* CE0* CE0* CE00* CE05 CE05 CE05 CE005 CE055* CE075* CE05 CE05 CE05 CE005 CE055* CE075* CE05 CE05 CE05 CE005 CE07* CE0* CE0* CE0* CE00* CE05 CE05 CE05 CE005 BLOWER MOTOR FLA...0.0.0. 7. 7..7. KW.0 5..0.9 5.9. 5. 0. 5.9. 9..0 5..0.9 5.9. 5. 0. 5.9. 9.. 0.. 9.5. 0. 5.9. 0..0 5..0.9 5.9. 5. 0. 5.9. 9.. 0.. 9.5. 0. 5.9. 0. ELECTRIC HEATERS STAGES TOTAL 9. 7.. 57. 7. 0.9.......0 5.....7.7.0 5.5. 5.0 7.....5. 0. 5. 0. 9..0 5.....7.7.0 5.5. 5.0 7.....5. 0. 5. 0. 9. TOTAL UNIT AMPACITY.. 5..5 0... 9..0 9...9 9. 9...9.7. 9. 0. 9. 55. 7. 9.5..9.. 7. 5.7..5 9..5.5.7....5.5.0 5.9 7.9 9. 7. 9. 5..9 7.9.. 9.0. FUSE SIZE 0 0 00 5 75 0 0 00 5 5 5 0 5 0 0 0 0 00 5 5 0 0 5 0 SIZE HACR BREAKER 0 0 00 5 75 0 0 00 5 5 5 0 0 0 00 5 5 0 50.TGY MIN. WIRE SIZE AWG 0 /0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Dual element, time delay type Standard circuit breakers may be used in Canada and on applications over 0 amps where the heaters are separately fused. Based on 0 C copper conductors (up to 00 amps max. or 75 C copper conductors (00 amps and over) Electric Heat Correction Factors Nominal Voltage Voltage KW Cap Multipier 0 0.00 0 0.9 0.9 00 575 0.9 * These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code ((eg., Chicago), the following fuse block accessories are available for field installation. Fuse Block FB0 FB05 0/ Volts Volts Unitary Products Group 5

50.TGY FIELD WIRING POWER WIRING REFER TO THE ELECTRICAL DATA TABLES TO SIZE THE DISCONNECT SWITCH, OVERCURRENT PROTEC TION AND WIRING. COOLING ONLY ( VOLT THERMOSTAT) THERMOSTAT TERMINALS UNIT TERMINAL STRIP TB VOLT TRANSFORMER CONTROL WIRING COOLING / HEATING ( VOLT THERMOSTAT) THERMOSTAT TERMINALS UNIT TERMINAL STRIP TB ADD JUMPER VOLT TRANSFORMER VOLT THERMOSTAT TH070. IF THE UNIT HAS AN ECONOMIZER, REMOVE JUMPER J FROM TERMINALS AND 0 ON THE RELAY BOARD TO PREVENT SIMULTANEOUS OPERATION OF THE COMPRESSOR AND THE ECONOMIZER. IF YOU WANT TO CONTROL THE ECONOMIZER ON A SECOND STAGE OF COOLING, USE THERMOSTAT TH0. ADD JUMPER COOLING / HEATING (ELECTRONIC THERMOSTAT) MULTISTAGE THERMOSTAT TERMINALS UNIT TERMINAL STRIP TB VOLT TRANSFORMER VOLT THERMOSTAT TH070. IF THE UNIT HAS AN ECONOMIZER, REMOVE JUMPER J FROM TERMINALS AND 0 ON THE RELAY BOARD TO PREVENT SIMULTANEOUS OPERATION OF THE COMPRESSOR AND THE ECONOMIZER. IF YOU WANT TO CONTROL THE ECONOMIZER ON A SECOND STAGE OF COOLING OR HAVE AN ELECTRIC HEAT ACCESSORY WITH TWO STAGES OF HEAT, USE THERMOSTAT TH0. COOLING / HEATING (ELECTRONIC THERMOSTAT) SINGLE STAGE THERMOSTAT TERMINALS UNIT TERMINAL STRIP TB ADD JUMPER NOT USED ADD JUMPER TO REMOTE SENSOR TH0 IF USED ELECTRONIC PROGRAMMABLE THERMOSTAT ET0 (INCLUDES SUBBASE) SECOND STAGE COOLING IS NOT REQUIRED ON UNITS LESS ECONOMIZER. SECOND STAGE HEATING IS ONLY REQUIRED ON UNITS WITH A TWO STAGE ELECTRIC HEATER. VOLT TRANSFORMER ELECTRONIC PROGRAMMABLE THERMOSTAT ET070 (INCLUDES SUBBASE). IF THIS UNIT HAS AN ECONOMIZER, REMOVE JUMPER J FROM TERMINALS AND 0 ON THE RELAY BOARD TO PREVENT SIMULTANEOUS OPERATION OF THE COMPRESSOR AND THE ECONOMIZER. IF YOU WANT TO CONTROL THE ECONOMIZER ON A SECOND STAGE OF COOLING, USE THERMOSTAT ET0. REMOVE JUMPER J FROM TERMINALS AND 9 ON JUMPER PLUG CONNECTOR P ON UNITS WITH ECONOMIZER. TERMINALS A AND A PROVIDE A RELAY OUTPUT TO CLOSE THE OUTDOOR ECONOMIZER DAMPERS WHEN THE THERMOSTAT SWITCHES TO THE SETBACK POSITION. Unitary Products Group

50.TGY UNIT DIMENSIONS (DCE AND,, 5 & TON) All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. FIELDSUPPLIED DISCONNECT SWITCH LOCATION (DirectDrive units) FIELDSUPPLIED DISCONNECT SWITCH LOCATION (DirectDrive units) GAS ENTRY ( NPTI AT GAS VALVE) GAS ENTRY ( NPTI AT GAS VALVE) UTILITIES ENTRY DATA KNOCKOUT HOLE SIZE USED FOR (DIA.) A 7/" * Control Wiring (Side or Bottom)** B " * Power Wiring (Side or Bottom) C 5/" Gas Piping (Front) D /" Gas Piping (Bottom) *Knockouts in the bottom of the unit can be located by the slice in the insulation. **Do not remove the " knockout ring. CLEARANCES Front DCE Units " Units " Back " (Less Economizer) " (With Economizer) Left Side (Filter Access) "(Less Economizer) " (With Economizer) Right Side (Cond. Coil) " Below Unit 0" Above Unit 7" (For Condenser Air Discharge) Units may be installed on combustible floors made from wood or class A, B or C roof covering material. Units must be installed oudoors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. NOTES: DCE Models: Units and ductwork are approved for zero clearance to combustible materials when equipped with electric heaters. Models: A " clearance must be provided between any combustible material and the supply air ductwork for a distance of feet from the unit. The products of combustion must not be allowed to accumulate within a confined space and recirculate. Locate unit so that the vent air outlet hood is at least: Three () feet above any forced air inlet located within 0 horizontal feet (excluding those integral to the unit). Four () feet below, horizontal feet from, or foot above any door or gravity air inlet into the building. Four () feet from electric meters, gas meters, regualtors and relief equipment. RETURN CONDENSER OUTDOOR (Economizer) Unitary Products Group 7

50.TGY UNIT DIMENSIONS CONT D. (DCE and,, 5 & TON) 7 REAR VIEW SIDE AND RETURN DUCT OPENINGS 7 7 7 5 DUCT COVERS Units are shipped with all air duct openings covered. For side duct applications;.remove and discard the supply and return air duct covers..connect ductwork to duct flanges on the rear of the unit. For bottom duct applications;. Remove the side supply air duct cover to gain access to the bottom supply air knockout panel.. Remove and discard the bottom knockout panel.. Replace the side duct cover.. With filter section access panel removed from the unit, remove and discard the bottom return air knockout panel. 5. Replace the filter access panel. 7 5 7 CONDENSATE DRAIN CONN. (Must be trapped) 9 REAR VIEW DETAIL A UNIT WITH ECONOMIZER RAINHOOD 9 7 L.H. END VIEW B 0 7 7 7 REAR VIEW L.H. END VIEW DETAIL B UNIT WITH FIXED OUTDOOR / BAROMETRIC RELIEF RAINHOOD 5 0 7 A 7 BACK DIM. 5 TON TON A 9/" " B /" " B CONDENSER COIL END OF UNIT APPROXIMATE CENTER OF GRAVITY FRONT A CENTER OF GRAVITY Unitary Products Group

50.TGY ROOF CURB DIMENSIONS (DCE and,, 5 & TON) ROOF CURB BENEFITS FRONT VIEW (JOIST SUPPORT) FRONT VIEW (JOIST SUPPORT) ROOF CURB RETURN DUCT 7" SUPPORT RAILS /" " DUCT The space between the ducts allows for jumping an existing roof joist. " ROOF CURB RETURN DUCT 7" SUPPORT RAILS /" " DUCT The 7" curb length allows for spanning roof joists that are spaced on 7" centers. " " " NOTE: Both supply air and return air duct openings are square and are the same size, providing easy duct installation. Ducts can be installed onto the curb from the roof. All electrical wiring connections can be made inside the curb. /" " 7" (ALTERNATE) The overall duct dimension allows ductwork penetration between roof joists that are spaced on " centers. UNIT AND CURB APPLICATION Unitary Products Group 9

TYPICAL APPLICATIONS ROOF JACK INSTALLATION ROOF CURB INSTALLATION SLAB ON GROUND INSTALLATION TYPICAL ROOFTOP INSTALLATION ( SHOWN) FIELDSUPPLIED DISCONNECT SWITCH 0/0, VOLT 0/0, 575 VOLT Unitary Products Group P.O. Box 59, York, Pennsylvania USA 7559 Subject to change without notice. Printed in U.S.A. Copyright by York International Corporation 995. All Rights Reserved. 50.TGY Supersedes: 50.TGY (9)