Product Information Packet

Similar documents
Product Information Packet

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 1500 Btu MODEL # S

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 500 Btu MODEL # S

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 400 Btu MODEL # S AAC-140B-4XT-EP AAC-140B-4XT-HC-EP

Quality Enclosures and cooling solutions for every environment

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

Cooling Solutions for Mission-Critical Electronics

Blade Series Heat Exchanger Operation and Installation

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

Panel Mounted Heat Exchangers by Dantherm, Inc.

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

Desiccant / Pump Dehumidification System. Model Operating Manual

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

KNHX32 SERIES NEMA 4/4X AIR-TO-AIR HEAT EXCHANGERS

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

IW-25-2 Dehumidifier Installation & Operations. Manual

5) Do not start or stop the unit by inserting or pulling out the power plug.

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

Intelligent Electronic Enclosure Thermal Management Systems

PROAIR Air Conditioner

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL. Rev. F 2015 Pentair Equipment Protection P/N

INSTRUCTION MANUAL. T-SERIES Air Conditioner. T29 Model Pentair Equipment Protection P/N McLean Parts 5736 N. Michigan Rd.

SEALED ENCLOSURE COOLING

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

Product Information Packet

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

TL-105 COLUMN HEATER

T-Series Air Conditioner T20 Model

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

SPECTRACOOL Air Conditioner. N17 Model INSTRUCTION MANUAL. Rev. G 2015 Pentair Equipment Protection P/N

ProAir CR43 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

OPENING AN ENCLOSURE and blowing a fan on heat sensitive components

Product Information Packet

T-SERIES Air Conditioner. T53 Model INSTRUCTION MANUAL nvent Rev. G P/N

ACT-HSC Series Heat Sink Coolers Sealed Enclosure Cooling Installation Guide

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

T-Series Air Conditioner T15 Model

BUNN H5E H5M H5X BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

Power Pack Service Manual

GENESIS Air Conditioner. M52 3-Phase Model INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N

RATIO:GUARD Model E-1S EC Monitor

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL. Rev. B 2016 Pentair Equipment Protection P/N

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL. Rev. D 2015 Pentair Equipment Protection P/N

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Installation and Operations Manual

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Equipment Protection P/N

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

INSTRUCTIONS! DO NOT DISCARD!

V LPM Desiccant Air Dryer Installation and Operation Manual

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

T-Series Air Conditioner T53 Model

Power Pack Service Manual

ion Genesis Pump Controller

T-Series Air Conditioner

XC Portable Air Conditioning

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

SEALED ENCLOSURE COOLING

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

Quest Dry 105, 155, and 205 Dual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

ProAir CR29 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

SELF-CONTAINED POWER MISTER

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

ADVANTAGE SERIES KXRP33 AIR-TO-AIR HEAT EXCHANGER

INSTRUCTION MANUAL P Heating and 1 Cooling

Quest Power Electric Heat EHS 62 Pro

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

INSTRUCTIONS! DO NOT DISCARD!

POWER PACK SERVICE MANUAL

VSA Series Air Dryer. User s Guide

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

T-Series Air Conditioner

INSTALLATION AND OPERATING MANUAL

Transcription:

Product Information Packet Model AHP-6200 Series Solid State, Air Conditioner Thank you for your purchase. Information has been enclosed regarding the installation, specifications, and wiring of your solid-state assembly. Please read and follow all instructions carefully before installation. Only qualified technicians should install this equipment. If you have any questions regarding your equipment, please do not hesitate to call us at 773-342-4900, and we will be happy to assist you. We are open from 8:00 am-4:30 pm Central Time. Included in this packet you will find: Installation Notes for Air Conditioners Product Literature and Specifications Mounting Cutout Drawing # SK130301 Installation Drawing # SK130302 Temperature Control Information Warranty Information

Mounting Styles: Important Installation Notes for Air Conditioners Both thru mount and flush mount units can be positioned in any orientation and on any enclosure surface. It is important to consider interior air flow patterns when determining the mounting location. Also of importance is an unrestricted flow of ambient air thru the hot side heat exchanger. Ease of access and inspection must be considered for those applications in particularly severe environments which may require occasional maintenance. Vertical (Side/Front/Back) Mounting: Vertical mounting refers to the vertical direction of the cold side or interior fins and is recommended for applications with high humidity, poor and incomplete cabinet seals or any condition which may cause the cold side fins to be maintained at temperatures below the dew point for long periods of time allowing for the formation of condensation. The vertical fin direction provides a drip path whereupon condensation can be collected via a moisture removal system (standard on FHP-units) or a drip pan positioned below the cold side fins. Drip pans are optional for thru mount units. Ambient Air Path Enclosure Internal Air Path Seal Condensate Removal System: All FHP-Series and AHP-1400 air conditioners contain a built-in condensate removal system. The condensate kit consists of a antifungal sponge with a condensate wick. PVC tubing is also provided for drainage. Drip pans are optional for thru mount units which must be evaluated on an individual basis. Equations defining a relationship between the cold side fin and enclosure temperatures are provided to assist in the evaluation. Top Mounting: Though often the easiest location to mount it is often the most difficult to protect from condensation in this orientation due to the fin orientation, gravity and any susceptible components below. If a drip pan is employed by the end user use caution to place the pan far enough away from the internal fan to minimize the restriction of air flow. The pan should cover the fin ends as well as the fan area. When there is a choice, the vertical orientation is preferred by most users. Maintenance: Since the technology is solid-state, there are no filters, compressors, or fluorocarbons to maintain. The only moving parts are the fans. It is recommended for harsh or dirty environments that the heat sinks be cleaned from time to time. This can be accomplished by directing compressed air over the external fins or on NEMA 4 versions by hosing the unit down. This will increase the overall life and performance of the system. Cautions: Take care when mounting not to damage the seal between the hot and cold side sinks. Do not attempt to mount a unit to a warped surface or try to make the units mounting surface conform to an unflat surface. Do not pinch or damage any leads when mounting. Do not over tighten any installation screw, use reasonable force. Always mount with any condensate drain down. Do not compress the cold side between the hot side and any other surface. Do not obstruct the airflow on either side. When mounting consider the natural air flows of the enclosure. Connect power only after the installation is complete. Notes on condensation: Condensation occurs at the cold side fins when the surface temperature goes below the dew point. To reduce or remove condensate, consider the following: Regulate the Fin Temperature above the Dewpoint. Keep Enclosure Closed and Sealed from Outside Humidity. Use Desiccant (Moisture absorbing Granules.) Employ Condensate Removal System/Drip Pans. If you have any questions regarding your installation, Please feel free to contact our technical department for assistance at 773-342-4900.

AHP-6250 Air Cooled Through Mounted Nema-12, 4, 4X Air Conditioner/Heat Exchanger 120 VAC Input High Efficiency 4340 BTU/HR FEATURES High capacity thermoelectric design Power saving air to air heat exchanger (ECO-mode) Heavy duty full perimeter mounting Lower profile intrusion into enclosure Central input cord for easy mounting Closed loop design Condensate control and evaporation system Increased efficiency at higher ambients by as much as 10% Virtually maintenance free No compressor Environmentaly friendly and safe Stainless Steel exterior housing Mounts and operates in any orientation Integral temperature controller Weight 170 LBS. CONTROL TEMPERATURES Active Cooling 35 C Heat Exchanger (ECO-Mode) 25 C Active Heating 10 C Typical Hysteresis 5 C Operating Ambient -40/+65 C Operating Enclosure -10/+60 C POWER INPUTS Voltage 120 VAC Current, Active 14 AMPS Current, ECO-Mode 3.0 AMP Frequency 50/60 Hz PERFORMANCE RATINGS Cooling (Traditional) 4340 BTU/HR Cooling (Din 3168) 1273 WATTS Cooling COP (at L35 L35) 0.76 Heating (Traditional) > 5524 BTU/HR Heating (Din 3168) > 1620 WATTS Heating COP > 1.0 Heat Exchanger (ECO-mode) 45 W/ C CONFIGURATIONS INCLUDES Power supply Temperature controller Power saving heat exchanger mode (ECO-Mode) Mounting gasket Mounting hardware Power input cord Circuit breaker 250 VDC configuration for crane applications available MODEL PART NUMBER NOTES TEMPERATURE ENVIRONMENT CONTROL AHP-6250 0-K4J0-0-000 Cool only, industrial fans & power supply TC-4F NEMA-12, IP 52 AHP-6250HC 0-K4I0-1-000 Heat/Cool, industrial fans & power supply TC-7F NEMA-12, IP 52 AHP-6250XE 0-K4J0-4-000 Cool only, sealed hot side fans & power supply TC-4F NEMA-4, IP 56 AHP-6250XEHC 0-K4I0-5-000 Heat/Cool, sealed hot side fans & power supply TC-7F NEMA-4, IP 56 AHP-6250X 0-K4J0-2-000 Cool only, Mil. grade hot side fans & power supply TC-4F NEMA-4X, IP 56 AHP-6250XHC 0-K4I0-3-000 Heat/Cool, Mil. grade hot side fans & power supply TC-7F NEMA-4X, IP 56 TECA 1-888-TECA-USA (832-2872) www.teca-usa.com

PERFORMANCE CURVE PERFORMANCE CURVE Air Conditioner - Air Cooled AHP-6250 MOUNTING STYLE Through Mounted ENVIRONMENTS SERVED NEMA-12 IP 52 NEMA-4,4X IP 56 RATING (TRADITIONAL) 4340 BTU/hr @ 0 F T 6060 BTU/hr @ +20 F T RATING (DIN 3168) 1273 Watts L35 L35 600 Watts L35 L50 DIMENSIONS Equation of line: y= ( C) x=capacity (Watts) Enclosure Air y=.022x-28 Cold Sink y=.016x-28 Air Flow Pattern www.teca-eu.com 1-888-TECA-USA (832-2872) TECA

AHP-6252 Air Cooled Through Mounted Nema-12, 4, 4X Air Conditioner/Heat Exchanger 240 VAC Input High Efficiency 5200 BTU/HR FEATURES High capacity thermoelectric design Power saving air to air heat exchanger (ECO-mode) Heavy duty full perimeter mounting Lower profile intrusion into enclosure Central input cord for easy mounting Closed loop design Condensate control and evaporation system Increased efficiency at higher ambients by as much as 10% Virtually maintenance free No compressor Environmentaly friendly and safe Stainless Steel exterior housing Mounts and operates in any orientation Integral temperature controller Weight 170 LBS. CONTROL TEMPERATURES Active Cooling 35 C Heat Exchanger (ECO-Mode) 25 C Active Heating 10 C Typical Hysteresis 5 C Operating Ambient -40/+65 C Operating Enclosure -10/+60 C POWER INPUTS Voltage 240 VAC Current, Active 9.2 AMPS Current, ECO-Mode 1.5 AMP Frequency 50/60 Hz PERFORMANCE RATINGS Cooling (Traditional) 5196 BTU/HR Cooling (Din 3168) 1524 WATTS Cooling COP (at L35 L35) 0.7 Heating (Traditional) > 7365 BTU/HR Heating (Din 3168) > 2160 WATTS Heating COP > 1.0 Heat Exchanger (ECO-mode) 45 W/ C CONFIGURATIONS INCLUDES Power supply Temperature controller Power saving heat exchanger mode (ECO-Mode) Mounting gasket Mounting hardware Power input cord Circuit breaker 250 VDC configuration for crane applications available MODEL PART NUMBER NOTES TEMPERATURE ENVIRONMENT CONTROL AHP-6252 0-K4J2-0-000 Cool only, industrial fans & power supply TC-4F NEMA-12, IP 52 AHP-6252HC 0-K4I2-1-000 Heat/Cool, industrial fans & power supply TC-7F NEMA-12, IP 52 AHP-6252XE 0-K4J2-4-000 Cool only, sealed hot side fans & power supply TC-4F NEMA-4, IP 56 AHP-6252XEHC 0-K4I2-5-000 Heat/Cool, sealed hot side fans & power supply TC-7F NEMA-4, IP 56 AHP-6252X 0-K4J2-2-000 Cool only, Mil. grade hot side fans & power supply TC-4F NEMA-4X, IP 56 AHP-6252XHC 0-K4I2-3-000 Heat/Cool, Mil. grade hot side fans & power supply TC-7F NEMA-4X, IP 56 TECA 1-888-TECA-USA (832-2872) www.teca-usa.com

PERFORMANCE CURVE PERFORMANCE CURVE Air Conditioner - Air Cooled AHP-6252 MOUNTING STYLE Through Mounted ENVIRONMENTS SERVED NEMA-12 IP 52 NEMA-4,4X IP 56 RATING (TRADITIONAL) 5200 BTU/hr @ 0 F T 7000 BTU/hr @ +20 F T RATING (DIN 3168) 1524 Watts L35 L35 800 Watts L35 L50 DIMENSIONS Equation of line: y= ( C) x=capacity (Watts) Enclosure Air y=.021x-32 Cold Sink y=.015x-32 Air Flow Pattern www.teca-eu.com 1-888-TECA-USA (832-2872) TECA

0.40 [10] 0.46 [12] 3.10 [79] 7.10 [180] 11.10 [282] 13.10 [333] 17.10 [434] 19.10 [485] 23.10 [587] 25.10 [638] 29.10 [739] 33.10 [841] 35.74 [908] 36.20 [919] Ø0.281 [Ø7] Guide Hole AHP-6200 SERIES MOUNTING CUTOUT AA 03/06/2013 SK130301 D8652 MASTER 0.37 [9] 0.40 [10] 4.95 [126] 9.89 [251] 14.84 [377] 19.39 [492] 19.78 [502] Ø0.281 [Ø7] Guide Hole 28 X Ø0.312 AHP-6200 Outline Cutout

Mounting, Monture, Montage, Montaggio Alternate, Alternative, Alternative, Alternativa Enclosure, Armoire, Gehäuse, Armadi Gasket, Joint, Dichtung, Guarnizione Exhaust, Echappement, Abluft, Scarico Guide Hole Mounting Cutout Reference: SK130301 Longer Guide Stud Intake Air, Air d'entrée, Einlaßluft, Aria di presa Insulation, Isolation, Isolierstoff, Isolamento Exhaust, Echappement, Abluft, Scarico Guide Hole Longer Guide Stud Notes: - Lay out the mounting cutout and holes on one of the panels of the enclosure. Note the different size (smaller) guide holes. Reference Mounting Cutout drawing SK130301. - Using an appropriate cutting tool cut the mounting cut out and drill the holes. - Install (2) longer guide studs (10-32 X 1") on the AHP-6200 mounting flange, in the two opposite corners matching the two Ø0.281 guide holes of the cutout. - Install the remaining (28) stud (10-32 X 3/4") on the AHP-6200 mounting flange. - Place the mounting gasket on the AHP-6200 mounting flange, the studs will keep the gasket in place. - Align the two guide studs with the two guide holes of the mounting cutout. - Push the AHP-6200 through the cutout making sure the two guide studs go through the guide holes in the cutout. - Once the guide studs clear the guide holes the rest of the studs will line up and clear the mounting holes. - Push the AHP-6200 flush too the enclosure surface. - From inside the enclosure install the 10-32 flat washers, 10-32 lock washers and 10-32 Hex nuts on the studs and tighten in an "X" pattern. AHP-6200 SERIES INSTALLATION AA 03/07/2013 SK130302 D8653 SK130301

Power Temperature Controllers TC-1F POWER TEMPERATURE SWITCHES Models TC-1F power temperature controller, with small tolerance and reset differential, are the simplest and most cost effective way to control a cooling or heating device (VAC or VDC) without a need for a relay. For circuits that have higher current draw simply use them in conjunction with a solid state relay. Part Numbers: Mode Part Number Note Cool TC-1C-XX switch closes on temperature rise Heat TC-1H-XX switch closes on temperature drop XX: Specify temperatures 20 C, 25 C, 30 C, 35 C for cool mode and 10 C, 15 C for heat mode Example: TC-1C-20 and TC-1H-10 VOLTAGE CURRENT SET POINT T RESET AMPS OLERANCE C DIFFERENTIAL C 125 VAC 2 +/- 3 3-6 250 VAC 1.3 +/- 3 3-6 12 VDC 2 +/- 3 3-6 24 VDC 1.3 +/- 3 3-6 Dimensions: Inches [Millimeters] TC-4F COOL ONLY WITH ECO-MODE Model TC-4F is simillar to TC-1F plus it has a 2nd power switch for heat exchanger mode (ECO-Mode). The active cool set point for TC-4F is 35 C and for heat exchanger mode (ECO-Mode) is 25 C. MODEL PART NOTES HX COOL RESET RESET OPERATING SWITCHING ACTIVE MODE ECO-MODE NUMBER NUMBER TEMP. C TEMP. C (MAX) C (TYP) C VOLTAGE VOLTAGE SWITCHING SWITCHING CURRENT CURRENT TC-4F-DC 4F-24G-00-000 24 VDC 25 +/- 3 35 +/- 3 6.5 3 24 VDC 24 VDC.02-20 ADC 1.3 ADC TC-6F COOL ONLY Model TC-6F (Cool Only) thermostat is designed using two temperature power switches in conjunction with a solid state relay. A three position switch is provided to adjust temperature settings. MODEL PART NOTES TEMP @ TEMP @ T1-T2 RESET RESET TEMP @ T3 OPERATING SWITCHING SWITCHING NUMBER NUMBER T1 C T2 C (MAX) C (TYP) C C VOLTAGE VOLTAGE CURRENT TC-6F 6F-00A-00-000 No Relay 35 +/- 5 25 +/- 5 10 +/- 3 6.5 3 Continuous On NA NA NA TC-6F-AC 6F-03T-00-000 VAC Version 35 +/- 5 25 +/- 5 10 +/- 3 6.5 3 Continuous On 85-250 VAC 24-280 VAC 10 TC-6F-DC 6F-43D-00-000 12/24 VDC 35 +/- 5 25 +/- 5 10 +/- 3 6.5 3 Continuous On 12/24 VDC 0-100 VDC.02-20 ADC TC-6F-DC 6F-33D-00-000 48 VDC 35 +/- 5 25 +/- 5 10 +/- 3 6.5 3 Continuous On 48 VDC 0-100 VDC.02-20 ADC TC-3F HEAT AND COOL Model TC-3F (Heat/Cool) thermostat incorporates the same technology as the TC-6F. It contains a single setting each for both heating and cooling as referenced below: MODEL PART NOTES COOL HEAT RESET RESET OPERATING SWITCHING SWITCHING NUMBER NUMBER TEMP. C TEMP. C (MAX) C (TYP) C VOLTAGE VOLTAGE CURRENT TC-3F-AC 3F-04R-00-000 VAC Version 35 +/- 5 15 +/- 5 6.5 3 85-280 VAC 24-280 VAC 10 AMPS TC-3F-DC 3F-44G-00-000 12/24 VDC 35 +/- 5 15 +/- 5 6.5 3 3.5-32 VDC 0-100 VDC.02-20 ADC TC-3F-DC* 3F-44P-00-000 12/24 VDC 35 +/- 5 15 +/- 5 6.5 3 3.5-32 VDC 0-100 VDC.02-20 ADC * H-Bridge relays included TC-7F HEAT/COOL WITH ECO-MODE Model TC-7F (Heat/Cool) thermostat incorporates the same technology as the TC-3F. It contains a single setting each for both heating and cooling and a heat exchanger mode (ECO-Mode). MODEL PART NOTES COOL HX HEAT RESET RESET OPERATING SWITCHING SWITCHING NUMBER NUMBER TEMP. C TEMP. C TEMP. C (MAX) C (TYP) C VOLTAGE VOLTAGE CURRENT TC-7F-DC 7F-24G-00-000 24 VDC 35 +/- 3 25 +/- 3 10 +/- 3 6.5 3 24 VDC 24 VDC.02-20 ADC H-Bridge relays included For custom variations of any of the controls, contact TECA. TECA 1-888-TECA-USA (832-2872) www.teca-usa.com

LIMITED WARRANTY In the event a defect in material or workmanship is discovered in any of TECA s products within one year after the date they are delivered to Buyer, and if: (a) TECA is notified of the defect in writing by certified mail within 14 days of the date of discovery; (b) TECA may then either, at its sole discretion, inspect the product at Buyer s location, or require that the product be made available at Buyer s expense at TECA s premises for TECA s inspection within 14 days of the date of notification; and (c ) the products are defective and the defects result from faulty materials and/or workmanship and not in any way from accident, misuse, misapplication, mishandling, modification, or alteration by the Buyer or the shipper, then TECA shall, at its sole option, repair or exchange defective products free of charge to Buyer, or credit to buyer the price of the defective products. ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, ARE EXCLUDED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL TECA BE LIABLE FOR ANY CLAIM BASED UPON BREACH OF EXPRESS OR IMPLIED WARRANTY OR ANY OTHER DAMAGES WHETHER SPECIAL, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOST PROFITS, BUSINESS INTERRUPTION, OR LOSS OF BUSINESS OR CUSTOMER RELATIONSHIPS. RETURNED GOODS, RESTOCKING CHARGES In order to return merchandise for any reason ( repair, replacement, or credit) a return authorization number must be issued by TECA. New merchandise may not be returned for credit beyond 60 days from shipment. Charges for incidental or other damages may also be made. All returned goods must be sent freight prepaid. A restocking charge of 15% will apply. On special equipment and custom modified equipment orders, additional incremental cancellation charges may be made.