VPAP COPD. H5i. Welcome Guide. Making quality of care easy. Respiratory Care Solutions. English NONINVASIVE VENTILATOR HEATED HUMIDIFIER

Similar documents
VPAP Auto VPAP ST VPAP S. H5i. Welcome Guide. English POSITIVE AIRWAY PRESSURE DEVICE HEATED HUMIDIFIER

VPAP Adapt. H5i. Welcome Guide. English. adaptive servo-ventilator

AutoSet AutoSet for Her Elite Escape Auto Escape. H5i H5i for Her. Welcome Guide. English. POSITIVE AIRWAY PRESSURE DEVICEs HEATED HUMIDIFIER

VPAP Adapt. H5i. Welcome Guide. English POSITIVE AIRWAY PRESSURE DEVICE HEATED HUMIDIFIER

VPAP ST with ivaps. Welcome Guide. Making quality of care easy. English. Respiratory Care Solutions NONINVASIVE VENTILATOR

S9 AutoSet & S9 Elite

S9 Escape. Welcome Guide. English POSITIVE AIRWAY PRESSURE DEVICE

AutoSet CS POSITIVE AIRWAY PRESSURE DEVICE. Welcome Guide. English

AutoSet & Elite. Welcome Guide / S9 Series. AutoSet & Elite WELCOME EUR2 / APAC. English Svenska Norsk Suomi Dansk Eesti 简体中文 繁體中文

heated humidifier H5i Welcome Guide English

User guide User guide English

User guide User guide English

H4i. User Guide HEATED HUMIDIFIER. English

H4i HEATED HUMIDIFIER

Adult and paediatric ventilators. Quick Setup Guide. English

Quick start guide. English

Quick setup guide. English

S9 Series AutoSet & Elite

English Please read the entire Information and Welcome Guides before using your device.

VPAP ST VPAP S AutoSet CS S9 Auto 25

Non-invasive/invasive ventilators. User Guide. English

User guide User guide English

User guide User guide English

User guide User guide English

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

User guide. User guide. English

User guide User guide English

Quick start guide. CPAP Pro. Auto CPAP. Navigating in the menu. Caring for my. Setting up my therapy. DreamStation. Additional help and tips

H5i disinfection guide

Positive airway pressure therapy may be contraindicated in some patients with the following preexisting

User guide User guide English

User guide User guide English

System Contents Your REMstar Pro C-Flex+ system includes the following items: Reusable gray foam filter Disposable ultra-fine filter (optional)

Contraindications Positive airway pressure therapy may be contraindicated in some patients with the following preexisting

Bipap A30/40 ventilator and System One humidifier

Clinical guide. English

User guide User guide English

DreamStation Service & Technical Reference Manual

User guide User guide English r2 cover.indd 2 8/04/2016 4:17:25 PM

Clinical Use Only. ResMed HumidAire 2i. Disinfection and Sterilisation Guide. English

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

LINE. Patient compass. Welcome Guide English. Your guide to the therapy device

Clinical guide. English

REMstar Auto A-Flex USER MANUAL

USER Manual JR 10/02/06

REMstar Auto A-Flex USER MANUAL

BiPAP Pro Bi-Flex USER MANUAL

Instructions For Use. Hybernite ROC 2300 Rainout Control System

DreamStation. BiPAP Pro. Auto BiPAP. User manual

System One Heated Humidifier USER MANUAL

A U T O S E R I E S Operating Manual

SleepEasy. User Manual

Disconnection Alarm Guide. English

I N S T R U C T I O N S

Operating Manual. Model HC254

Oxygen Concentrator Instruction Booklet

VPAP III ST-A with QuickNav

Clinical guide. English

PAP Disinfecting Device User Guide. For all PAP Devices (Positive Airway Pressure) CPAP, APAP, Bi-PAP

Table of Contents. isleep 20 users manual

User guide User guide English

1 Intended Use of the Breas HA 01 Humidifier

Piccolo Cyclonic Vacuum Cleaner

User guide User guide English

DreamStation. BiPAP autosv REF R04 HM 01/30/2017 EN-DOM. User manual

User guide User guide English

User manual. DreamStation Heated Humidifier

User guide User guide English

User manual. DreamStation CPAP DreamStation CPAP Pro DreamStation Auto CPAP DRAFT

NIPPY junior+ Quick Reference Guide

Quick start guide. BiPAP AVAPS

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

ACCESSORIES ISLEEP VIVO Z1

Quick start guide. BiPAP AVAPS

Attention. Please handle this product with care and inspect it regularly to ensure it is in good working order.

Dome Kettle. polished stainless steel body BTDK120

Administration of AMBISOME Using the GemStar Pump

Cl inician Training Packet

STAINLESS STEEL JUICER - BLENDER COMBO. 600 Watt / 2 Speed & Pulse INSTRUCTION MANUAL

Instructions for set-up, use and cleaning

FILLING & CLEANING GUIDE

Download the FREE application. on your Smartphone or on your tablet. and

Home Medical Equipment Oxygen

IMPORTANT NOTICE FOR CLEANING AND REASSEMBLY

DreamStation Go. Heated Humidifier. User manual. Instructions for use

Achieva. Ve nt i l at or with Flow Acceleration Limit and Apnea Backup. User s Manual

MODEL 7000 SUCTION UNIT

CPAPSolutions. Product Profile. Overview: The Family of SleepStyle TM CPAP Solutions

Ultrasonic Humidifier TALL. Product Manual

Installation and Setup

DreamStation CPAP. CPAP Pro. Auto CPAP. User manual

DIGITAL ULTRASONIC HUMIDIFIER WITH HUMIDISTAT

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

CLINICAL MANUAL REF JH 6/7/10 CLINICAL MANUAL

Monsoon RS400. Operating Instructions Mode d emploi Bedienungsanleitung Manual de Instrucciones Istruzioni per il funzionamento Gebruiksaanwijzing

Due to continual improvement in design or otherwise, the product you purchase may differ slightly from the illustration in this book.

User guide User guide English

POWERSHRED 425Ci/425i/485Ci/485i

1.5 GALLON ULTRASONIC HUMIDIFIER MODEL # EE-5303W

Transcription:

VPAP COPD NONINVASIVE VENTILATOR H5i HEATED HUMIDIFIER Welcome Guide English Respiratory Care Solutions Making quality of care easy

Respiratory Care Solutions Making quality of care easy

Welcome Thank you for choosing the VPAP COPD or H5i. Before operating the device, please read the entire Welcome and Information Guides. DC power inlet Module/Adapter port Air filter Air outlet SD card slot VPAP COPD at a glance The VPAP COPD system comprises the following elements: VPAP COPD device Air tubing 90W power supply unit S9 Travel bag SD card S9 SD card protective folder. Optional components include: H5i heated humidifier Standard air tubing SlimLine air tubing 3 m air tubing ClimateLine heated air tubing ClimateLine MAX heated air tubing ClimateLine MAX Oxy heated air tubing 30W power supply unit (does not support H5i) Power Station II battery pack DC/DC Converter 24V/90W. Traveling tips When traveling with your VPAP COPD only: Ensure you pack the SlimLine or Standard air tubing as the ClimateLine, ClimateLine MAX and ClimateLine MAX Oxy heated air tubing are not designed to connect directly to the device. Ensure you purchase and travel with the approved power cord for the region where you will be using the device. 1 English

Flip lid seal Flip lid Air outlet ClimateLine, ClimateLine MAX or ClimateLine MAX Oxy connection port H5i at a glance Release button H5i water tub The H5i system comprises the following elements: H5i heated humidifier H5i standard water tub ClimateLine MAX Oxy heated air tubing (if sold as a Climate Control Kit). Optional components include: ClimateLine MAX heated air tubing ClimateLine heated air tubing H5i cleanable water tub. Traveling tips When moving or traveling with your H5i: Ensure that the water tub is empty. Disconnect the H5i from the device by using the release button. Latch 2

Setting up 6 4 1 3 5 2 7 3 English

Setting up with supplemental oxygen If oxygen is prescribed by your clinician, set up the VPAP COPD with the H5i and the ClimateLine MAX Oxy as follows: 1. Align your H5i with the VPAP COPD and push them together until they click into place. 2. Connect the DC plug of the power supply unit to the rear of the device. 3. Connect the power cord to the power supply unit. 4. Plug the other end of the power cord into the power outlet. 5. Connect one end of the air tubing firmly onto the air outlet. 6. Connect the assembled mask system to the free end of the air tubing. 7. Connect the oxygen supply tubing to the oxygen connector of the ClimateLine MAX Oxy. Ensure that it is attached firmly. Note: Before adding oxygen, familiarize yourself with the specific warnings relating to the use of supplemental oxygen. These can be found at the end of the Information Guide. Setting up without supplemental oxygen If you use the VPAP COPD with the ClimateLine MAX Oxy but without supplemental oxygen, perform steps 1-6 above. Ensure that the cap of the oxygen connector is attached firmly. Notes: Always ensure that the VPAP COPD and H5i are placed on a stable, level surface for proper operation. Always ensure that the VPAP COPD is placed in an area where the alarm LED indicators are clearly visible. Place the power supply unit away from the H5i to allow for adequate ventilation. For more information on assembling your mask see your mask user guide. Recommended masks are available on www.resmed.com on the Products page under Service & Support. 4

Filling the water tub 1. Slide the latch and lift open the flip lid. 2. Remove the water tub. 3. Fill the water tub (through the center hole) with distilled or deionized water up to the maximum water level mark (12.5 fl oz / 380 ml). 4. Return the water tub to the H5i. 5. Close the flip lid ensuring that it clicks into place. 5 English

VPAP COPD basics Info menu* Allows you to view your sleep statistics or exit from the menu. LCD screen Displays the menus, treatment screens and reminders. Start/Stop button Starts or stops treatment. Key: Home Humidity Level Ramp Heated Tube Climate Control Start/Stop Push dial Alarm mute Setup menu Info menu Alarm mute Press once to mute alarms. Press a second time to unmute. Setup menu* Allows you to make changes to settings or exit from the menu. Push dial Turning the dial allows you to scroll through the menu and change settings. Pushing the dial allows you to enter into a menu and confirm your choice. Alarm and therapy LEDs Yellow flashes during an alarm. Blue on during therapy (if enabled by clinician). *The Info and Setup menus are disabled if S9 Essentials has been enabled by your clinician. 6

Adjusting humidity level Ranging from OFF to 6, you can adjust the humidity level at any time to find the setting that is most comfortable for you. To adjust the humidity level: 1. From your HOME screen, turn until the HUMIDITY LEVEL screen is displayed in blue. 2. Press. The selection is highlighted in orange. 3. Turn until the humidity level that you require is displayed. 4. Press to confirm your choice. Warming the H5i The warm-up feature is used to pre-heat the water before starting treatment. To start warming: 1. Navigate to the humidity level icon. 2. Push and hold for three seconds. The Warming Up status bar is displayed. You can stop warm-up at any time by pressing for at least three seconds. You can start treatment at any time by pressing. Note: In order to assist the heater plate in cooling, your device will continue to blow air for up to an hour after treatment has stopped. However, you can unplug the device from the power outlet at any time and allow the heater plate to cool without air flow. 7 English

Adjusting ramp time Designed to make the beginning of treatment more comfortable, ramp time is the period during which the pressure increases from a low start pressure to the treatment pressure. To adjust your ramp time: 1. From your HOME screen, turn until the RAMP screen is displayed in blue. 2. Press. The selection is highlighted in orange. 3. Turn until the ramp time you require is displayed. 4. Press to confirm your choice. Using Mask Fit You can use Mask Fit to help you fit your mask properly. This feature delivers CPAP pressure for a three-minute period, prior to starting treatment, during which you can check and adjust your Mask Fit to minimize leaks. 1. Fit your mask as described in the mask user guide. 2. From your HOME screen, push and hold for three seconds. One of the following MASK FIT screens is displayed: 3. If necessary, adjust your mask, mask cushion and headgear until Mask Fit indicates Good. After three minutes, the pressure reverts to the set pressure and treatment will begin. You can end Mask Fit at any time by pressing. 8

S9 Essentials S9 Essentials is designed to make device interaction and menu navigation easier for you. If enabled by the clinician, S9 Essentials disables the Info and Setup functionality so that you can simply start and stop therapy and adjust ramp, humidification and Climate Control. Selecting the mask type To select your type of mask: 1. Press. The SETTINGS screen is displayed. 2. Turn until Mask is displayed in blue. 3. Press. The selection is highlighted in orange. 4. Turn until the mask setting that you require is displayed. 5. Press to confirm your choice. 6. Push to return to the HOME screen. Note: Selecting the mask type is not possible if S9 Essentials has been enabled by your clinician. 9 English

Getting started 1. Make sure the power is connected. 2. Adjust the ramp time or humidification level if required. 3. Fit your mask as described in your mask user guide. 4. To start therapy, simply breathe into the mask and/or press. 5. If you use supplemental oxygen, turn on oxygen. 6. Lie down and arrange the air tubing so that it is free to move if you turn in your sleep. 7. If you use supplemental oxygen and want to stop treatment at any time, turn off oxygen first. 8. Remove your mask and/or press. Notes: If your clinician has enabled SmartStart your device will start automatically when you breathe into the mask and stop automatically when you remove your mask. If power is interrupted during treatment, the device automatically restarts therapy when power is restored. 10

Viewing the treatment screens Depending on how the system has been configured, you will see one of the following example screens once therapy has started: H5i humidifier H5i humidifier ClimateLine or ClimateLine MAX Climate Control Auto H5i humidifier ClimateLine or ClimateLine MAX Climate Control Manual Therapy data without optional accessories Oximetry data via the oximeter adapter Pressure bar: In S mode, the fixed vertical lines on the pressure bar indicate the expiratory and inspiratory pressures. While the treatment is ramping (indicated by an orange ramp icon) or variable, the pressure values appear in orange. When a set pressure is reached these values are displayed in white. In CPAP mode, only a set pressure is shown. 11 English

To toggle between the treatment screens, press from your HOME screen. Treatment with cycle (Ti Max or Ti Min) breath indicators Treatment with spontaneous cycled breaths Treatment with alarm functionality Viewing the Info menu The Info menu has a series of screens showing your sleep quality, sleep report and service information. To view the Info menu, push from your HOME screen. In the Sleep Quality screen, you can always view your usage hours during the last session and if enabled by your clinician, data on Mask Fit and AHI is displayed. To return to the HOME screen, push. In the Sleep Report, only the period can be changed other values are for display only. In the Service information, the total device run hours (includes warm-up/cool-down times for the humidifier) and the software identifications are displayed. 12

Viewing alarms The VPAP COPD is fitted with an alarm module that continuously monitors both therapy and device conditions. Alarms are only activated when therapy is running. An alarm condition is indicated by an audible sound, a flashing yellow alarm LED and a message on the screen. When the device is turned on, the yellow alarm LED will flash, and the alarm will sound to confirm that the alarm is working. Alarm activated Alarm cleared Multiple alarms When an alarm activates, a corresponding alarm message is displayed. If multiple alarms are active, the latest alarm message is displayed and as these are cleared each message can be read. Muting the alarm To clear an alarm message, press. This allows you to return to the previously displayed screen. If the alarm condition remains, the alarm will re-occur. Note: Power Fail and Alarm Fail alarms are cleared by pressing. To view the list of alarm messages, go to the Treatment screen and press until Treatment screen 3 is displayed. To mute an alarm for two minutes, press once. If the condition remains, the alarm will sound again after two minutes. To turn on the alarm again, press a second time. The alarm LED will remain lit for as long as the condition remains. 13 English

Cleaning and maintenance You should regularly carry out cleaning and maintenance as described in this section. Disassembling the H5i water tub 1. Slide the latch. 2. Lift open the flip lid. 3. Remove the water tub. 4. Discard any excess water from the water tub. 5. Unclip all four side latches. 6. Pull apart the tub lid and base. Daily cleaning 1. Remove the air tubing by pulling on the finger grips on the cuff. Hang the air tubing in a clean, dry place until next use. 2. Wash the disassembled tub lid and base in warm water using a mild detergent. 3. Rinse thoroughly in clean water and allow them to dry away from direct sunlight. Notes: Do not hang the air tubing in direct sunlight as it may harden over time and eventually crack. Do not wash the air tubing in a washing machine or dishwasher. Weekly 1. Remove the air tubing from the device and the mask. 2. Wash the air tubing in warm water using mild detergent. 3. Rinse thoroughly, hang, and allow to dry. 4. Before next use, reconnect the air tubing to the air outlet and mask. Monthly 1. Wipe the exterior of the device and H5i with a damp cloth and mild detergent. 2. Check the air filter for holes and blockage by dirt or dust. Replace the air filter if necessary. 3. Peel the flip lid seal from the flip lid and wash it in warm water using a mild detergent. 14

Maintenance checklist Inspect the H5i water tub and flip lid seal for wear and deterioration. Replace the water tub if any component is leaking or has become cracked, cloudy or pitted. Replace the flip lid seal if cracked or torn. Clean white powder deposits in the water tub by using a solution of one part household vinegar to 10 parts water. Reassembling and filling the H5i water tub 1. Place the tub lid back onto the base. 2. Clip all four side latches. 3. Fill the water tub with distilled or deionized water up to the maximum water level mark. 4. Return the water tub to the H5i. 5. Close the flip lid ensuring that it clicks into place. Replacing the air filter Replace the air filter every six months (or more often if necessary). 1. Remove the air filter cover from the back of the device. 2. Remove and discard the old air filter. 3. Insert a new ResMed air filter ensuring that it is sitting flat in the air filter cover. 4. Replace the air filter cover. Notes: Ensure the air filter and air filter cover are fitted at all times. Do not wash the air filter. The air filter is not washable or reusable. Air filter cover Air filter 15 English

SD card An SD card has been supplied to gather therapy data from your device and provide settings updates from your clinician. When instructed to do so, disconnect the device from the power outlet, remove your SD card, insert it in the protective folder and send it to your clinician. Removing the card 1. Push in the SD card to release it. 2. Remove the card. 3. Insert the card into the protective folder. 4. Send the protective folder back to your clinician as instructed. For more information on removing and inserting your card refer to your S9 SD Card Protective Folder provided with your device. Please retain the S9 SD Card Protective Folder for future use. 16 1 2 3 4 Notes: For Troubleshooting information refer to the Information Guide. For more product information see www.resmed.com.

Respiratory Care Solutions Making quality of care easy

368841/2 2017-11 VPAP COPD H5i WELCOME AMER ENG Manufacturer: ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia. See www.resmed.com for other ResMed locations worldwide. For patent information, see www.resmed.com/ip. S9, H5i, ClimateLine, SlimLine, SmartStart and VPAP are trademarks of ResMed Ltd. S9, ClimateLine, SlimLine, SmartStart and VPAP are registered in U.S. Patent and Trademark Office. 2017 ResMed Ltd. Global leaders in sleep and respiratory medicine www.resmed.com