VENTILATION SOLUTIONS STRONG RELIABLE QUIET
WHY VENTILATION IS SO IMPORTANT It is important to understand what contributes to poor indoor air quality and the potential affects and harm that can be caused by poor ventilation in a home. Poor ventilation can cause a number of problems such as condensation, mould, allergies, dust mites and air pollutants (odours). These can potentially lead to structural building issues and health problems for residents. A properly ventilated home can create a safe, comfortable and healthier environment. MOISTURE that is not properly ventilated can cause mildew and mold formation, which can potentially lead to structural and health problems. Exhaust ventilation solutions from HPM remove humidity at the source to help maintain the optimal humidity balance of 40 to 60 percent. OFF-GASSING from construction materials, carpeting, adhesives and synthetic materials as well as solvents from common household cleaners can accumulate in tightly built homes. PARTICULATES from dust, allergens, pet dander, and more can contribute to poor indoor air quality up to 100 times dirtier than outside air. With a properly ventilated home, you create a more enjoyable, comfortable, and healthier environment. COOKING EFFLUENTS from food preparation can infiltrate the whole house in minutes. Grease, oils and aromas settle permanently into carpets, furniture, clothing and other surfaces. Kitchen ventilation solutions help eliminate cooking effluents for a cleaner, more comfortable and healthier environment. VENTILATION SOLUTIONS FOR EVERY ROOM CEILING EXHAUST FANS NON-DUCTED IN-LINE EXHAUST FAN FANLIGHT NON-DUCTED Combined 00mm ceiling fan and light Low profile ceiling exhaust fans with round or square grille EF00RDWE, EF00RDMS, EF00SQWE page (0) EF50RDWE, EF50RDMS, EF50SQWE page () Fan motor is mounted inside roofspace. This connects two locations so air conditioning can be shared EFIL100SQWE, EFIL150SQWE page (6) HEAT 1, or 4 lamp exhaust fan and light R60LED, R60 page (8) BH1WE, BHNDWE, BH4NDMS page (34) WALL/CEILING EXHAUST FANS 100MM CEILING FANS 3 or 4 blades with quick-fit wiring With or without time delay optional mounting kits for ducting through walls EF100SQWE, EF100RDWE, EF100, RDWE page (14) White Aluminum, 430 Series, 304 Series, Rattan Series page (5) HEAT DUCTED or 4 lamp ducted centrifugal exhaust fans and light R6D, BH4DWE page (4) CEILING EXHAUST FANS DUCTED Ducted centrifugal fan EFD01RDWE, EFD01RDMS, EFD01RSQWE page (4) WALL/CEILING EXHAUST FANS 150MM Heavy duty models with optional window mounting kits WALL EXHAUST FANS WITH AUTOSHUTTERS Heavy duty models with optional window mounting kits EF150SQWE, EF150SQSWE, EF150RDWE, R61/8A page (16) EFS150SQWE, EFS150SQSWE, R61/9A page (18) 4 VENTILATION BROCHURE 5
HEAT 3 VENTILATION BROCHURE 33
HEAT SINGLE LAMP NON-DUCTED Perfect for ensuites and small bathrooms, this handy single heat lamp can help ward off the shivers in those cold months. The infrared heat lamps provide a focused source of fast, radiant heat making them ideal to be placed directly over the drying area for optimal heating performance. BH1WE/BH1MS R615 Heat lamps 1 x 75W 1x 75W 375W 75W Supply voltage 30 40V a.c 30 40V a.c Thermal overload protection 100 C >300mm N/A >300mm Weight 950g 750g Product codes White BH1WE 75W HEAT LAMP SAFE THERMAL OVERLOAD PROTECTION White BH1MS R615 Main applications Perfect for small bathrooms, toilets or ensuites BH1WE and BH1MS R615 10mm 10mm Ø165mm 175 MM 151 MM BH1WE BH1MS R615 34 VENTILATION BROCHURE 35
HEAT 3-IN-1 NON-DUCTED TWO LAMPS The Instant Heat 3-in-1 combines lighting, heating and ventilation in one stylish unit. The heat lamps, exhaust fan and centre light can be used separately or together to create the perfect bathroom environment. While the heat lamps produce instant heat, the centre light provides general illumination and the exhaust fan extracts steam and moisture. Centre Light BHNDWE/ BHNDMS 7W LED R80 E7 600 lm R6/1AC 100W ES Heat lamps x 75W x 75W Exhaust fan 40mm axial 40mm axial 690W 690W Supply voltage 30 40V a.c 30 40V a.c Motor rating 40W 40W Maximum airflow 40m³/h 40m³/h 75W HEAT LAMPS UP TO MAX AIRFLOW 40m 3 /h >500mm >500mm Weight 3.3kg 3.3kg Inclusions Excel Life 3-gang HEAT, FAN, LIGHT Excel 3-gang HEAT, FAN, LIGHT BHNDWE Main applications Perfect for small bathrooms and ensuites BHNDMS Product codes White Fascia BHNDWE Fascia BHNDMS White Fascia R6/1AC BHNDWE and BHNDMS 340mm 300 MM 370mm R6/1AC 340mm 300 MM 00mm 40mm 374mm R6/1AC 36 VENTILATION BROCHURE 37
HEAT 3-IN-1 NON-DUCTED FOUR LAMPS Relish the toasty comfort of four heat lamps for keeping warm in the cooler months. The heat lamps, exhaust fan and light in this stylish unit can be used together or separately so you can create the perfect environment, whatever the reason or season. 4 75W HEAT LAMPS Centre Light BH4NDWE/ BH4NDMS 7W LED R80 E7 600 lm R6/AC 100W ES UP TO MAX AIRFLOW 400m 3 /h Heat lamps 4 x 75W 4 x 75W Exhaust fan 30mm axial 30mm axial 140W 140W Supply voltage 30 40V a.c 30 40V a.c Motor rating 40W 40W Maximum airflow 390m³/h 390m³/h Main applications Perfect for medium-large bathrooms >500mm >500mm Weight 4.5kg 4.5kg Inclusions Excel Life 4-gang HEAT, HEAT, FAN, LIGHT Excel 4-gang HEAT, HEAT, FAN, LIGHT Product codes White Fascia BH4NDWE Fascia BH4NDMS White Fascia R6/AC BH4NDWE BH4NDWE and BH4NDMS R6/AC 00mm 405mm 374mm 3 MM 3 MM 405mm 00mm 40mm 3 MM 3 MM BH4NDMS R6/AC 38 VENTILATION BROCHURE 39
HEAT 3-IN-1 DUCTED TWO LAMPS A combination of light, heater and ducted exhaust fan perfect for smaller bathrooms and ensuites. Ducting to the outside prevents condensation damage to the ceiling. 75W HEAT LAMPS UP TO MAX AIRFLOW 180m 3 /h DUCTING KIT INCLUDED BHDWE R6D1 Centre Light 7W LED R80 E7 60W Incandescent lamp Heat lamps x 75W x 75W Exhaust fan Centrifugal Centrifugal 840W 630W Supply voltage 30 40V a.c 30 40V a.c Motor rating 50W 16W Maximum airflow 180m³/h with 3m x Ø150mm diameter ducting 95m³/h with 3m x Ø100mm diameter ducting Thermal overload protection 100 C N/A BHDWE Main applications Perfect for small bathrooms and ensuites INSTALLATION Draft stopper built-in >300mm Yes >0mm Yes Weight 4.3kg 3.0kg Inclusions Excel Life 3-gang HEAT, FAN, LIGHT. 3m x Ø150mm duct, external grille, duct tape and cable ties Excel 3-gang HEAT, FAN, LIGHT. 3m x Ø100mm duct, external grille, duct tape and cable ties Multi storey application Product codes White Fascia lamp BHDWE White Fascia lamp R6D1 R6D1 BHDWE 395 MM Standard roof application 440mm 50mm 05 MM 40 VENTILATION BROCHURE 41
HEAT 3-IN-1 DUCTED FOUR LAMPS A combination of light, heater and ducted exhaust fan perfect for larger bathrooms and ensuites. Ducting to the outside prevents condensation damage to the ceiling. Main applications Perfect for larger bathrooms and ensuites 75W HEAT LAMPS UP TO MAX AIRFLOW 40m 3 /h DUCTING KIT INCLUDED BH4DWE R6D Centre Light 7W LED R80 E7 100W R80 Incandescent lamp Heat lamps 4 x 75W 4 x 75W Exhaust fan Centrifugal Centrifugal 1570W 140W Supply voltage 30 40V a.c 30 40V a.c Motor rating 50W 30W Maximum airflow 180m³/h with 3m x Ø150mm diameter ducting Thermal overload protection 100 C 135m³/h with 3m x Ø100mm diameter ducting N/A >300mm >60mm INSTALLATION Draft stopper built-in Yes Yes BH4DWE Weight 5.kg 4.5kg Inclusions Excel Life 4-gang switch engraved HEAT, HEAT, FAN, LIGHT 3m x Ø150mm duct, external grille, duct tape and cable ties Excel 4-gang switch engraved HEAT, HEAT, FAN, LIGHT 3m x Ø100mm duct, external grille, duct tape and cable ties Product codes White Fasica 4 lamp BH4DWE Multi storey application White Fascia 4 lamp R6D BH4DWE R6D R6D 340mm 400mm 380mm 380mm Standard roof application 355 MM 95 MM 300 MM 300 MM 4 VENTILATION BROCHURE 43
POSITIONING OF HEAT & TIPS RANGE OVERVIEW It is important to consider the wet areas of a room when you place an instant heater in a bathroom or ensuite. For safety reasons, there are a few rules to follow when installing an exhaust fan close to a shower: OUTSIDE ZONES OUTSIDE ZONES CAT. NO DESCRIPTION FINISH COLOUR DUCTED MOTOR RATING MAX POWER CONSUMPTION HEAT LAMPS EXHAUST FAN TYPE BH1WE Single Lamp Instant Heat White No N/A 375W 1 x 75W N/A N/A MAX AIR FLOW 1. It is necessary to respect zones of installations Zone 0: This is the interior of the bathtub or shower basin 0.6m 0.6m BH1MS Single Lamp Instant Heat No N/A 375W 1 x 75W N/A N/A R615 Single Lamp Instant Heat White No N/A 75W 1 x 75W N/A N/A Zone 1: This extends above zone 0 and around the perimeter of the bath or shower basin to.5m for NZ and.5m for Australia above the floor level Zone : This extends 600mm beyond Zone 1 and to a height of.5m for NZ and.5m for Australia above floor level 1 BHNDWE -lamp non-ducted White Fascia No 40W 690W x 75W Axial 40m 3 /h BHNDMS -lamp non-ducted Fascia No 40W 690W x 75W Axial 40m 3 /h R6/1AC -lamp non-ducted White Fascia No 40W 690W x 75W N/A 50m 3 /h Where possible we recommended your fan is not installed directly above the shower/bath as condensation may occur causing dripping. Note: Example shown is typical only. Consult AS/NZS 3000 for full definition of installation zones in wet areas. 0 1 BH4NDWE 4-lamp non-ducted White Fascia No 40W 140W 4 x 75W Axial 390m 3 /h BH4NDMS 4-lamp non-ducted Fascia No 40W 140W 4 x 75W Axial 390m 3 /h R6/AC 4-lamp non-ducted White Fascia No 40W 140W 4 x 75W N/A 400m 3 /h. You MUST have your exhaust fan vented /ducted horizontally to an eave AND must have an open window or 0mm off the base of a door to allow cross ventilation. BHDWE -lamp ducted White Fascia Yes 50W 840W x 75W Centrifugal 180m³/h BHDMS -lamp ducted Fascia Yes 50W 840W x 75W Centrifugal 180m³/h BH4DWE 4-lamp ducted White Fascia Yes 50W 1570W 4 x 75W Centrifugal 180m³/h Zone 0 Zone 1 Zone BH4DMS 4-lamp ducted Fascia Yes 50W 1570W 4 x 75W Centrifugal 180m³/h R6D 4-lamp ducted White Fascia Yes 30W 140W 4 x 75W Centrifugal 40m 3 /h TIPS Choose the position where your heat lamp will be installed carefully. It is recommended to place the heater in the middle of the room for it not to be near the wet areas You should also position the heater directly to the place where you will be standing when you will need the heat after you have left your bath or shower Instant heat should be cleaned every 6 months or more often to prevent dust buildup Heat lamps are not designed to heat entire rooms, but to provide instant and focused heat directly below. Position an Instant Heat directly over the drying area for optimal heat performance. closed window The exhaust fan in the Instant Heat requires a balanced air flow to perform at maximum efficiency. This means there needs to be air flowing into the room from sources such as windows, vents or under doors to allow a cross flow of air movement. 44 VENTILATION BROCHURE 45