Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

Similar documents
CCD and CID solid-state detectors

SOLAR CELL PRODUCTION REQUIRES EFFECTIVE METROLOGY

Technological developments in infrared imaging: a fast growing market Dr. François Simoens, CEA-Leti, Marketing & Strategy Manager

IR IN MODERN TECHNOLOGY 1. Infrared Radiation in Modern Technology. Brian D. Dold. Brigham Young University - Idaho

Stand-off Detection of Trace Explosives by Infrared Photothermal Imaging. Trace Contamination

for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

Gas Temperature Measurements with High Temporal Resolution

Understanding total measurement uncertainty in power meters and detectors

THE PLACE TO BE FOR AUVERGNE RHÔNE-ALPES COMMITTED FRENCH TECH MEMBER

MULTI-FUNCTION InGaAs DETECTOR FOR SWIR IMAGING

64 Max IR Thermometer

An FT-NIR Primer. NR800-A-006

Bright, Chromatic and Distinct - Perception and Detection of LED-based Airfield Lighting

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

T2SL technology for Mid-IR detectors

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

Lasers Technical Seminar at Bruno Events Center on March 27 th, Next generation of SPADs - Single Photon Avalanche Detectors

Autonomous Vehicles. Pushing the Boundaries of Sensors and Emitters Reader Issue Beacons of the Industry Annual Reader Poll

The FEL Facility Optical Diagnostics and FEL Characterization

Wildland fire phenomenology experiments:

Dual Laser InfraRed (IR) Thermometer

The new generation Teledyne NIR detectors for the SNAP/JDEM mission spectrograph.

for Microelectronics Packaging Dave Vallett PeakSource Analytical, LLC Fairfax, Vermont, USA

Dual Laser InfraRed (IR) Thermometer

Uncooled Infrared Imaging: Higher Performance, Lower Costs

Automatic Detection of Defects on Radiant Heaters Based on Infrared Radiation

Date: Wednesday, January 31, 2018 Time: 8:30 am 5:00 pm Location: Moscone West (Room 2018, Level 2)

WHAT IS LASER ULTRASONIC TESTING?

Customization of Optoelectronic Detectors Part Two in a Six-Part Series

Spot on Fraunhofer IAF

CCTV, HOW DOES IT WORK?

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

User Detection Sensors

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

Leveraging Thermal Imaging for Gas Detection

LEARNING SPECIAL HAZARD DETECTION TYPES

1.1. SYSTEM MODELING

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

How SWIR Imaging contributes to the optimization of automatic quality control in the food industry

Dated 15-Dec-2000; J. Schilz, subject to change

Recent Advances in Large Area Micro-channel Plates and LAPPD TM

Instrumental technique (MCP detectors) - Kamalesh ( )

Measurement of Light. Photosensors

6340(Print), ISSN (Online) Volume 4, Issue 2, March - April (2013) IAEME AND TECHNOLOGY (IJMET)

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

Industrial presentation. Philippe Marchais - July 3rd, NDIP Tours

Smart Fire Prevention

Variable Temperature Microprobe Systems

Building and Characterizing 14GHz InGaAs Fiber Coupled Photodiodes

North Dakota State University Laser Safety

62 MAX/62 MAX + Infrared Thermometer. Users Manual

Wavelengths: From UV to Visible and IR COBRA TM Max

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

ENHANCED VISION - INFRARED 1

SPECTRAL INSTRUMENTATION

Why is Laser Safety Important Laser usage is growing rapidly e.g. laser points, CD/DVD, industrial applications Heavy use now in laboratories for

February 12, PHY357 Lecture 11. Experimental Methods. Accelerators. Particle Interactions. Particle Detectors. Full experiment (eg.

Surface Acoustic Wave Technology based Temperature Monitoring of High Voltage and High Current Switchgear Boxes

Laser Diagnostics and Optical Measurement Techniques

R&D for the improvement of O&M in CSP plants. Dr. Marcelino Sánchez. - November,

Automated Infrared Thermography Complete Solutions from a Single Source

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

Research on Key Technologies of Photoelectric Guided Weapons and Their Development Trends

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

A Sense of Light. Visit our Light-Shop: Order No. OS30016P / Printed in Germany

Multitel develops components and full instruments for in-vitro and in-vivo diagnostics in the biomedical, food and drug sectors.

LUXEON S. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON S Photobiological Safety Report

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

OPTICAL FIBER SOLUTIONS

2018 New Infrared Technologies, S.L.

Office of Nonproliferation and Verification Research and Development University and Industry Technical Interchange (UITI2011) Review Meeting

gray Laser Power Detectors For fast and accurate measurements

FLIM/FFS and Nanoimaging Upgrade of Olympus confocal microscopes

64 Max IR Thermometer

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

Methane to Markets Oil and Natural Gas Technology Transfer Workshop

FPI Detectors Pyroelectric Detectors with Spectrometer Functionality

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

The Art and Science of Being Cool

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

Optical Time Domain Reflectometry (OTDR)

state of the art methane leak detection CHARM and GasCam 2011 October 13 th Dr. Axel Scherello

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

High Temperature InfraRed Thermometer with Laser Pointer

AIDA Advanced European Infrastructures for Detectors at Accelerators. Presentation. LumiCal alignment system, status report

Broadening IR applications through using spectral filters

Source Test and Characterization Program

PIXEL DETECTOR COLLABORATION MEETING

Infrared Business Tips & Insight

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

LASER SAFETY BARRIER

Company profile and Products

Laser Use at Subaru Telescope (NAOJ) Laser Safety Policy

Transcription:

Microsanj LLC 3287 Kifer Road Santa Clara, CA 95051 Application Note Comparing Thermoreflectance (TTI), Infrared (IR), Near Infrared Emission (EMMI), and Optical Beam Induced Resistance Change (OBIRCH) Imaging Techniques: Which characterization method is best for your application? The Future of Thermal Imaging is Here!!! Aug 2013 AN-004 Copyright 2013 Microsanj LLC

Introduction The growing complexity and continued emphasis on speed in today s microelectronic devices has led to smaller and smaller geometries and, in turn, has placed increased demands on the need for adequate thermal and defect characterization techniques to ensure device reliability and performance. Several approaches are commercially available to designers and reliability engineers for electronic and optoelectronic characterization. These systems can be costly and may not always meet all of the requirements necessary to fully understand the properties of the devices being analyzed. In this application note we will provide a brief overview of four commercially available imaging techniques; Infrared (IR), Near infrared Emission Microscopy (EMMI), Optical Beam Induced Resistance Change (OBIRCH), and Thermoreflectance Thermal Imaging (TTI). IR, EMMI, and OBIRCH systems have been commercially available for some time, whereas TTI has only recently evolved from being a university research tool to a commercially available thermal imaging system. Overview of Thermal Characterization Techniques Infrared Microscopy (IR) is a general description for imaging techniques that detect infrared emitted light from the target device. This technique is based on black-body radiation to obtain device thermal profiles. Near room temperature, cameras with a sensitivity of 4-7 microns (InSb) or 8-12 microns (HgCdTe or Quantum Well Infrared Photodetectors QWIP) are typically used. Although IR systems can provide excellent temperature resolution, time and spatial resolution 1 are only fair. At times special sample preparation (e.g. coating by black paint) is required and for accurate temperature measurement, calibration is necessary since surface emissivity is fabrication dependent. Typical temperature resolution is 25 mk at 60 to 80 C. IR systems for microscale chip thermal characterization tend to be expensive. Emission Microscopy (EMMI) detects Near-Infrared light emitted from the target device. There are two failure categories that can be detected by Emission Microscopy: (1) The light wave generated in the target device by electron-hole recombination, and (2) The electron emission by colliding (thermalized) electrons with emissions in the Near-Infrared wavelength region. The light generated by a defect is typically very faint. Therefore to detect the failure, the imaging device must have very high photon sensitivity in the wavelength of interest (typically 1.0 to1.8 microns using InGaAs or deep-depleted Silicon CCDs). 1 See Microsanj application note MS-AN-001 for additional details on Emission Microscopy. Copyright 2013 Microsanj LLC Page 2

Optical Beam Induced Resistance Change (OBIRCH) is an imaging approach that uses a laser to induce a resistance change in the device-under-test (DUT). This technique can be used to identify differences between areas on the device that are defect-free relative to areas that may have defects. Changes in the device input current are measured to determine the resistance change. A region of interest is selected on the device-undertest and the selected area is scanned by a laser. The current of the DUT is monitored and any changes in the current are noted along with the laser position at the time of the change. In regions with no defects there will be good thermal spreading and very small current change. Regions with defects however, will exhibit greater changes in resistance resulting in a large current change. When displayed on a device image the regions with higher current (resistance) changes are displayed as bright spots. OBIRCH systems can detect temperature changes due to the incident laser illumination in the micro-kelvin range and spatial resolution is somewhat improved over IR systems but is not in the sub-micron range. Some systems have an option for time domain imaging with lock-in capability to the laser scan. This provides hundreds of milliseconds for the time resolution. Due to the scanning laser illumination, systems are also expensive and take up considerable floor space. Thermoreflectance Thermal Imaging (TTI) is a technique that exploits the change in material reflectivity due to a temperature change. Since the thermoreflectance coefficient is very small for most materials of interest, a lock-in technique is employed to enhance the signal-to-noise ratio to achieve good temperature resolution. The illumination sources are in the 400 to 800 nm wavelength range, resulting in sub-micron spatial resolution. Using a Near-IR illumination source, as with the Microsanj NT300Aseries, enables thru-the-substrate imaging. This also enables the collection of emission images along with the thermoreflectance images. TTI Advantages Time Resolution: Thermoreflectance imaging has the highest temporal resolution for measuring temperatures in full-field images. The Microsanj commercial systems, NT210A/NT310A, can achieve 100 nanoseconds in a megapixel image and 800 picosecond time resolution has been achieved with our newest visible wavelength thermoreflectance system, the NT410A. The full-field time resolution of the IR camera on the other hand, is limited by the frame rate which is in tens of milliseconds. It is sometimes possible to go to one millisecond time resolution with IR cameras but this requires pixel binning resulting in lower resolution images. Spatial Resolution: Diffraction-limited spatial resolution for thermoreflectance is 300-600 nm with illumination wavelengths in the visible band and about 1 micron for near-ir with 1.0-1.5 micron illumination wavelength used for through-the-substrate Copyright 2013 Microsanj LLC Page 3

measurements (NT300A-Series and NT410A). This is a factor of 3 to 10 better spatial resolution compared to IR microscopes based on InSb. Sample Heating: With thermoreflectance there is no need to heat the sample to 50 to 70 ºC as is required for most IR imaging systems to get good temperature resolution. Thermoreflectance imaging of chips can be done at room temperature or even below room temperature if there is a need to overdrive the chip. We have done thermoreflectance imaging of devices at cryogenic temperatures as low as 5 K. Simultaneous Emission and Thermal Imaging: With Microsanj TTI systems one can obtain reflection, emission, and thermal images simultaneously and overlay all three images. InSb IR cameras can only obtain thermal images and emission microscopes can only capture emissions in the 0.5-1.8 micron range (InGaAs camera). Transient Thermal Imaging: Transient thermoreflectance imaging adds another dimension to thermoreflectance imaging. By pulsing the device under test at a low duty cycle, the overall heating is concentrated in the device active area as opposed to the surrounding substrate. As a result localized hot spots can be more easily observed compared to a steady-state thermal image. Since today s microelectronic devices often have complex time-varying workloads, the synchronization of various signals in the chip are very important. The thermal response, however, is sometimes not taken into account in the layout of the circuitry thus the temperature distribution resulting from such complex operational modes is often unknown during the design phase. The transient temperature profile therefore, is not characterized until after the devices are manufactured. Time dependent temperature profiles around various active components are critical for predicting the performance and reliability of the circuit. Transient thermoreflectance addresses this requirement. TTI Limitations Thermoreflectance characterization has many advantages but it is not a solution to detect every possible device defect. Some limitations of transient thermoreflectance thermal imaging systems are as follows: Temperature resolution not as good as lock-in IR thermography: Our temperature resolution is typically 0.1 to 1 C with 30 seconds averaging. 0.006 to 0.01 C can be achieved when there is sufficient reflected light and averaging times of 20 minutes to hours. Lock-in InSb infrared cameras can achieve temperature resolution in the range of 10 micro Kelvin if the surface is painted black and long averaging times are employed. However, IR imaging s spatial and temporal resolutions are limited (full-field images in millisecond and single pixel transient response in microseconds). Lock-in IR thermography is typically much more expensive than thermoreflectance because of the high cost of long-wavelength optical components and sensors. Copyright 2013 Microsanj LLC Page 4

Emission resolution is lower than cryogenically cooled InGaAs cameras: Since we are currently using a room-temperature InGaAs camera for thru-the-substrate thermoreflectance imaging, our dark current is not as low as cryogenically cooled systems optimized for emission characterization. The thermoreflectance hardware/software system can easily be adapted with cryogenically cooled InGaAs cameras but this will significantly increase the system cost. Performance Summary The Thermoreflectance Thermal Imaging Technique is one of the most robust and sensitive methods for obtaining full-field transient temperature profiles at a reasonable price. This thermal imaging tool should be viewed as an additional tool which can significantly outperform conventional IR and Emission Microscopy (EMMI) in many applications and provide thermal information that will complement that obtained by EMMI or OBIRCH in other applications. For example, heating in metal interconnects will not produce any detectable emissions for near IR and if the temperature non-uniformity is not large enough, there may not be an OBRICH signal. Spatial Resolution Minimum power ** (1hr average) Temperature Resolution Full Frame Time Resolution Sample Temperature Other TTI IR EMMI OBIRCH 250 nm 1-2 μm* ~2-5 μm ~2 3 μm ~1.0 1.5 μm ~500 μw 0.1 0.5 ºC 1.0 C* (6 mk demonstrated) < 100 ns Typ 800 ps demonstrated -265 C to 500 C demonstrated Simultaneous EMMI & thermal is possible ~100 mw (<10 μw lock-in) 100 mk (10 mk lock-in) 10 s μw 10 s μw Doesn t measure device operating temperature Doesn t measure device operating temperature 10 s ms 10 s ms > 100 ms >50 C to 70 C Metals have low emissivity Can be a wide range Only for defects that emit light Can be a wide range Small resistance changes may be missed Relative Cost $ to $$ $$ to $$$ $$ to $$$ $$$ *These values for TTI apply to Thru-the-Substrate imaging ** Minimum detected power depends on the size and location of the heat source. Typical numbers for micron size hot spots are given. Copyright 2013 Microsanj LLC Page 5

There is much to be considered when evaluating which thermal imaging approach is best suited to any specific application. In some cases more than one imaging solution may be necessary to adequately characterize the thermal behavior of the device in question and/or identify defects. Conclusion In preparing this application note, Microsanj has made a diligent effort, with the information we currently have available, to provide you with a fair assessment of how these four different thermal imaging techniques compare. Hopefully this information will provide you with some insights as to where each of these techniques, based on their respective benefits and limitations, may fit with your thermal analysis requirements. If you feel we have incorrectly stated any performance estimates or miss-characterized any of the thermal imaging techniques described here, please let us know. It is also important to remind you that all of these techniques are subject to ongoing development; thus system configurations, performance, specifications, and relative costs are subject to change over time. Since any of these alternatives represents a significant financial investment it is important to ensure that you have the most up to date information available prior to making a final decision. For Thermoreflectance Thermal Imaging systems (TTI), the Microsanj team is always available for consulting services and they can perform testing on your devices in the Microsanj laboratory. If in doubt, as to how thermorflectance can address your thermal imaging requirements; a try before buy approach may prove to be the best strategy. Microsanj is a leading supplier of Thermoreflectance Imaging Analysis systems, tools, and consulting services. For more information see www.microsanj.com or inquire at: info@microsanj.com Copyright 2013 Microsanj LLC Page 6