Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Similar documents
Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

When You Need a Replacement Coil, Precision Matters.

Modular Supply Make-Up Air Unit

Energy Recovery with Cooling and Heating

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Plenum Fans. Model HPA. Direct Drive

EHH SERIES DRAW THROUGH FAN COILS CFM

SECTION AIR COILS

SECTION AIR COILS

Energy Recovery with Cooling and Heating Model ERCH

Technical Development Program

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services

Indirect Gas-Fired Make-Up Air

Steam Coils. Types HI-F5, HI-F8 and E-F5. Catalog 413-6

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

SSL & SBS Engineering Guide

SECTION AIR COILS

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

PRODUCT CATALOG BLOWER COILS.

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Economical, Flexible, Advanced Performance. Ventilation and Dehumidification for Healthy IAQ

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Daikin Direct Expansion (DX) Cooling Coils

PDF Created with deskpdf PDF Writer - Trial ::

Operation & Maintenance Manual

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

Increased Performance Higher System Efficiency Low Refrigerant Charge Compact Design

************************************************************************************************************************

MAC-120HE-03 Air-Cooled Chiller

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

AIR HANDLER DESIGN WORK SHEET

HEATING & COOLING COIL PRODUCTS

FCC Fan-Coil Units High-Performance, Vertical

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS

Liebert PDX and PCW Thermal Management Systems

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

Heating and Cooling Coils

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

Air-Handling System Cooling Options

INDUSTRIAL HEAT EXCHANGERS

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

Direct Gas-Fired Make-Up Air

FLUID COIL INSTALLATION OPERATION AND MAINTENANCE

COMMERCIAL HVAC EQUIPMENT Coils: Direct Expansion, Chilled Water, and Heating

Daikin Water Cooling, Heating, and High Capacity Booster Coils

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners

SeasonMaker ThinLine Fan-coil Units

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

GreenPark. GreenJet Throw Performance

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Product Specifications. Vertical Floor Consoles By First Co.

Upflow/Downflow A-Coil Specifications

Precise Temperature Control; Compact Footprint

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

COOLING / HEATING COILS

Installation, Start-Up and Service Instructions

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

1.1 This section applies to air handling units for HVAC Systems.

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

ACCESSORY KIT INSTALLATION INSTRUCTIONS

VariCool VAV Engineering Guide

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

MACH N-407 Heat Pump Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller

Water-Cooled Self-Contained Units

Direct Gas-Fired Make-Up Air Models DG and DGX

Mini-Space EC DX and CW 4 12 kw Systems Vertical Floor Mounted, 60 Hz Data

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Commercial/Industrial Products. Partnerships beyond metals

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Convectors Steam / Hot Water November, 2009

The ultimate fresh air solution.

KIC Air Curtains. Technical Guide

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

Condensing Unit Installation and Operating Instructions

SECTION FAN COIL UNITS

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Commercial and Industrial Applications

GUIDE SPECIFICATIONS AQUARIUS ii

Air-Handling System Cooling Options

THE ULTIMATE ROOFTOP SOLUTION

C22FC Bulletin # October 1993 Supersedes May 1993

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

Transcription:

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs 3/8, 1/2 and 5/8 inch OD Tubing March 2010

Custom Coils Custom Coils Configured to Meet Your Needs Greenheck is proud to offer a complete line of competitively priced, quality engineered replacement and OEM coils. Coils are made from the finest materials to your specifications and then tested with high pressure dry nitrogen gas for 100% quality assurance. Greenheck s experienced team of application specialists are only a phone call away and ready to respond to any questions you may have. Quick Build Program At Greenheck, our Quick Build (QB) program ensures that your coils will be manufactured to your specifications and shipped to meet your time requirements. We work together as a team to match the exact measurements and the performance requirements you need. Our efficient system can design and manufacture most custom coils for you in 3-, 5-, or 10-day turnarounds. Contact your local Greenheck Representative for more information on our Quick Build program or to order a coil. World Class Manufacturing Greenheck s custom coils are manufactured using advanced processes, superior engineering, and quality control procedures to guarantee the highest quality product. Highly skilled production workers use cost-efficient machines and unique die designs to add innovative features. And just to be sure you get the performance you expect when you specify Greenheck, our coils are tested in accordance with AHRI Standard 410-2001 and every coils bears the AHRI label. To guarantee your coil is going to perform as required, check for AHRI Certification. Leading Edge Technical Support Greenheck s products are supported by the industry s best product literature, electronic media, and selection software programs. Greenheck Coil technical literature, specifications, Installation, Operation, and Maintenance manual (IOM), and our Coil Selection software program is available at www.greenheck.com You can always count on personal service and expertise from our network of Greenheck representatives. To locate your local Greenheck representative, call 715 359 6171 or visit our Web site. 2

Coil Applications Heating / Cooling Greenheck coils are designed, manufactured and tested to meet a broad range of heating and cooling requirements. To achieve maximum efficiency and longevity, coils must be properly sized for the intended application. Water Coils can be used for a single purpose such as heating or cooling, or their function can be alternated between heating and cooling by changing the temperature of the water flowing through the coil. Depending on the application, it may be necessary to use a glycol mixture to prevent the liquid from freezing. Greenheck water coils are engineered to operate at pressures up to 250 PSIG and temperatures up to 300 F, but ancillary equipment such as valves and pumps will often dictate lower operating temperatures. All water coils are pressure tested at the factory with 450 PSIG of dry nitrogen. Steam Coils are used for heating applications and are built to operate at pressures of up to 125 PSIG with a maximum temperature of 353 F. They are pressure tested with 600 PSIG of dry nitrogen. The most frequent use of steam coils is for retrofitting or modifying existing steam heat systems. Direct Expansion (DX) Coils are part of a refrigerant filled system consisting of a condenser coil, evaporator coil and a refrigerant compressor. The evaporator coil must be paired with a thermal expansion valve (TXV) intended for the specific capacity and refrigerant type. When used in conjunction with a heat pump and reversing valves, a coil serves for both heating and cooling. DX Cooling Cycle Reheat Coil for Humidity Control Outdoor Air Intake Condenser Coils Evaporator Coil (DX) for cooling Evaporator Coils (DX) are made for heat absorption and generally function at a lower pressure. Coils made with 3/8-inch diameter tubing are rated for 400 PSIG and 300 F maximum operating temperature. Coils made with 1/2- or 5/8-inch diameter tubing are rated for 250 PSIG and a maximum operating temperature of 300 F. All evaporator coils are factory tested at 600 PSIG. These coils are generally used for spot cooling or as part of an air handling system. Condenser Coils are made for heat rejection, such as the heat absorbed by an evaporator coil, and they typically operate under higher internal pressures. Coils made with 3/8-inch tubing are rated for use at 600 PSIG and 300 F while coils made from 1/2- or 5/8-inch tubing are rated for 300 PSIG and 300 F. Condenser coils are sometimes used as part of a heat pump to provide heat in a specific location, but more often they are used to simply exhaust heat energy that is collected elsewhere. These coils are also factory tested to 600 PSIG. 3

Coil Applications Energy Recovery with Run Around Coil Loop Many scientific and industrial ventilation systems require the introduction of large amounts of outdoor air into the building. The expense of tempering that outdoor air can be greatly reduced by recovering energy from the exhaust airstream. Greenheck offers a run around coil loop that is resistant to exhaust air contaminants and also maintains isolation of the exhaust airstream from the intake airstream. A run around coil loop consists of a specially coated corrosion-resistant coil that is inserted into the building exhaust airstream and is connected to a matching coil in the building air intake. The coils are connected by means of a fluid loop filled with a glycol solution and a pump which is used to circulate the fluid. In the winter, the run around coil loop absorbs sensible (heat) energy from the exhaust airstream and transfers it into the intake airstream, and in the summer, sensible energy is absorbed from the intake airstream and transfers into the exhaust airstream. This results in significant energy savings in both summer and winter. Greenheck s custom coils are available with a corrosion-resistant specialty coating that ensures safe and consistent recovery of sensible energy. Diluted High Plume Exhaust Reheat Coil Cooling Coil Vektor Energy Recovery Coil Filters Make-Up Air Unit Energy Recovery Coil Filters VAV Bypass Air Glycol Loop Pump Outside Air Supply Exhaust Vektor Energy Recovery System with Run Around Coil Loop Energy savings resulting from a custom designed run around coil loop are significant. The Greenheck coil selection program can be used to calculate the energy efficiency of the recovery loop. Thermal and economic savings for the run around coil loop used in the Vektor Energy Recovery System can be evaluated in the Greenheck CAPS program. 4

Construction Features Complete Line of Standard and Custom Built Coils Chilled Water Hot Water DX Evaporator Heat Reclaim Condenser Standard Steam Non-Freeze Steam Distributing Booster / Duct Mounted Construction Features and Options Rows Chilled water and DX coils 1 to 12 rows Hot water coils 1 to 12 rows Steam coils 1 to 2 rows Condenser coils 1 to 12 rows Headers Type L or M from 7 8 in. OD to 4 1 8 in. OD copper Fin Materials.006 in.,.008 in. and.010 in. aluminum.006 in. copper Fin Spacing 1 2 in. OD Tubing - 6 to 14 fins per in. 5 8 in. OD Tubing - 6 to 14 fins per in. 3 8 in. OD Tubing - 10 to 20 fins per in. Brazing All joints are hand-brazed Connections Water and steam coils - Copper, steel or brass - MPT, FPT or sweat connections DX distributors - Standard or hot gas DX, condenser and heat reclaim - Copper sweat connections Supply connections on both ends of steam distributing coils Casings 16 and 14 gauge galvanized steel 16 gauge 304 stainless steel Copper Optional Seamless Rifled Tubing For enhanced performance Tube Material 3 8 in. OD x.016 in. wall, copper 3 8 in. OD x.016 in. wall rifled, copper (optional) 1 2 in. OD x.016 in.,.020 in. wall, copper 5 8 in. OD x.020 in.,.025 in.,.035 in.,.049 in. copper Other Options Nonstandard casing flange widths and casing depths Special coil coatings Additional distributors Nonstandard circuiting Intertwined circuiting (DX Only) Insulated coil sections 5

Quick Reference Chart 3/8 1/2 5/8 Wall Thickness (inches) 0.016 0.020 0.025 0.035 0.049 Fin Type Aluminum Copper Fins Per Inch (FPI) Min 10 6 6 Max 20 14 14 Fin Type Sine wave Lanced Corrugated Flat Connection Size (inches) Min 0.5 0.5 0.5 Max 4.0 4.0 4.0 Fin Height (inches) Min 4.0 5.0 4.5 Max 60 120 120 Increments of 1.00 1.25 1.50 Casing Material Standard Optional 16 gauge galvanized steel 14 gauge galvanized steel 16 gauge stainless steel.06 or.09 in. thick copper Casing Types Std. (1.5-inch flange) Standard Booster (1-inch flange) Slip and drive Endplates only Inverted S.P. flange Connection Types FPT - Female pipe thread MPT - Male pipe thread Sweat Refrigerant Types R-22 R-134a R-404A R-407C R-410A R-502 Fin Material Fin Material Aluminum Copper 3/8 1/2 5/8 Fin Thickness 0.006 0.008 0.010 Fin Type Sine wave Lanced Corrugated Flat Fluid Flow Rates For water coils, connections sizes are based on GPM of water GPM 1-4 4-8 8-16 16-30 30-40 40-70 75-150 Connection 3/4 1 1 1/4 1 1/2 2 2 1/2 3 (5/8 inch only) Coil Selection Program Software Visit www.greenheck.com/software to obtain Greenheck s coil selection software. Use of the self-explanatory software will guide the user in proper sizing and feature selection. Coil Drawing Worksheets Replacement Blank Coil Drawings which are helpful for recording coil construction details when sizing and ordering replacement coils are available from our Web site. The drawings are located on the Coils product Web page under the Other Product Information section. ITEM QTY ROWS FPI SP1 FH SP2 CH EP1 FL P.O. # W.O. # APPROVED BY DATE Performance Data ROWS 1 2 3 4 5 AVAILABLE 6 8 10 12 FPI 6 7 8 9 10 AVAILABLE 11 12 13 14 TUBES.020.025 OD & Wall 5/8 Thickness.035.049 COPPER ONLY 1/2.016 FINS ALUM..006.010 Material & Thickness COPPER.006 16 GA. GALV. STEEL CASING 16 GA. STAINLESS STEEL 5/8 7/8 1 1/8 HEADERS COPPER 1 3/8 1 5/8 2 1/8 ONLY 2 5/8 3 1/8 CONNECTION SIZES DIMENSIONAL DATA IN INCHES SUPPLY RETURN MPT SWEAT FPT CUSTOMER MODEL NO. TAG: NOTES EP2 CL MAX C OAL L CD S E R F SUPPLY RETURN CU STL CFM EDB/EWB LDB/LWB CAPACITY EWT LWT GPM 6

Quick Reference Chart Coil Type (Style) Custom Booster Chilled Water Hot Water Direct Expansion Condenser Standard Steam Steam Distributing Hot Water Standard Steam (inches) Rows 3/8 1/2 5/8 Min Rows 1 1 1 1 1 1 1 1 Max Rows 12 12 12 12 2 2 2 2 Fin Height (inches) Min 6 6 Max 24 24 Fin height is dependent on tube diameter (see chart) Increments 3 3 of Fin Length (inches) Min Minimum fin length is 1 inch 6 6 Max Max fin length is 250 inches with center supports every 50 inches 48** 48** Increments of Recommended Face Velocity (FPM) No restriction on fin length increments 1 1 Min 400 500 400 600 500 500 500 500 Max 550 800 550 750 850 850 800 850 Recommended Fluid Velocity (FPS - for water coils) Min 1.5 1.5 NA NA NA NA 1.5 NA Max 4.0 4.0 NA NA NA NA 4.0 NA Recommended Pressure Drop (ft. of H 2 O or psi) Min 1 1 1.5 3 1 1 1 1 Max 20 10 9 10 125* 125* 10 125* * Higher steam pressures will require heavier tube wall thicknesses. ** Booster coil fin lengths are dependent on fin height. Coil Measuring Tool Greenheck s coil measuring tool helps the user determine the specifications to properly size a replacement coil. It will quickly, easily and accurately check tubing and connection diameters, and fins per inch (FPI). Contact your local Greenheck representative to request a free coil measuring tool today. 5/8 inch 1 inch 1 inch 16 14 12 10 8 6 4 Fins per inch 400 Ross Avenue P.O. Box 410 WI 54476-0410 Tel: 715-359-6171 FAX: 715-355-2382 www.greenheck.com e-mail gfccoils@greenheck.com Connection Diameter 1½ inch 2 inch 2½ inch ½ inch 3 8 inch 7

1 inch Greenheck Coils Model Number Code Z CW 58 S 04 F 10 24 x 36 RH Z = Special Feature Coil Type CW = Chilled Water HW = Hot Water DX = Evaporator HR = Heat Reclaim CD = Condenser SS = Standard Steam SD = Steam Distributing DR = Evaporator, Rifled Tubes CR = Condenser, Rifled Tubes 58 = 5/8 12 = 1/2 38 = 3/8 Fin Type S = Sine wave L = Lanced C = Corrugated F = Flat Rows Deep 01, 02, 03, 04, 05, 06, 08, 10, 12, etc. Circuit D = Double O = One-and-a-Half F = Full T = Three-Quarter H = Half Q = Quarter S = Special A = Single Feed B = 2 Feed Fin Height x Fin Length Fins Per Inch 6-18 RH = Right Hand LH = Left Hand Connection hand is determined by looking at the inlet face of the coil, with the air hitting you in the back. Greenheck s Coil Measuring Tool Visit www.greenheck.com for specific coil worksheets to record the details below to help w/ replacement coil sizing Coil Type : water, booster, steam, steam distributing, DX, DX intertwined, condenser Coil Model # and manufacturer, design conditions and performance if known Dimensional data shown on the drawing, casing material (galvanized, stainless) Rows deep in direction of airflow, FPI, tube diameter, coil hand, connection size O.D. and type (MPT, FPT, Sweat) 5/8 inch 16 14 12 10 8 6 4 1½ inch Connection Diameter Fins per inch 400 Ross Avenue P.O. Box 410 Schoifeld, WI 54476-0410 Tel: 715-359-6171 FAX: 715-355-2382 www.greenheck.com e-mail gfccoils@greenheck.com 2½ inch 2 inch ½ inch 3 8 inch 1 inch Building Value in Air Greenheck delivers value to mechanical engineers by helping them solve virtually any air quality challenges their clients face with a comprehensive selection of top quality, innovative air-related equipment. We offer extra value to contractors by providing easy-to-install, competitively priced, reliable products that arrive on time. And building owners and occupants value the energy efficiency, low maintenance and quiet, dependable operation they experience long after the construction project ends. Our Warranty Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the shipment date. Any units or parts which prove defective during the warranty period will be replaced at our option when returned to our factory, transportation prepaid. Motors are warranted by the motor manufacturer for a period of one year. Should motors furnished by Greenheck prove defective during this period, they should be returned to the nearest authorized motor service station. Greenheck will not be responsible for any removal or installation costs. As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Prepared to Support Green Building Efforts P.O. Box 410 Schofield, WI 54476-0410 Phone (715) 359-6171 greenheck.com 00.TAP.1039 R2 3-2010 RG Copyright 2010 Greenheck Fan Corp.