Instruction Manual. Laser Attachment. Valid for Hardware SN 100 and higher

Similar documents
Important Safety Notice

Class 1 laser beam sensor safe for your eyes

HXL. Operating instructions

VISION H. Instruction manual

PLX. Operating instructions

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Class 1 laser beam sensor safe for your eyes

Instruction manual EN

1. Key Features and Benefits

Laser Use at Subaru Telescope (NAOJ) Laser Safety Policy

Class 1 laser beam sensor safe for your eyes

CONTRACTOR WHS HAZARD STANDARD LASER SAFETY EXTERNAL USE ONLY

Instruction Manual. Model No and Self-Leveling Cross-Line Laser Level

West Virginia University Laser Safety Program

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

Instruction Manual. Self-Leveling Laser Level Model No

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

G4 Pulsed Fiber Laser

LaserPoint srl - Via Burona, Vimodrone (Milano) - Italy Phone Telefax

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

3R, 3G 5R, 5G Point Laser Levels

CATALOGUE LASER POINTERS

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

Laser Distance Sensor Type M Analog-Output

Reflective Optical Beam Smoke Detector User Guide

WIO200 Water in oil sensor

TSLC 6 UV LED 24v Strips

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

3kW 6kW, QUBE Fiber Lasers

L / -014L / -015L

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

Self-Leveling Five-Beam Laser Pointer Model No Instruction Manual

Laser Radiation and High Voltage/Electrical Shock. Disclaimer and Limitation of Liability. Shipping Damage. Trademarks

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

Rice University Laser Safety Manual

Owner & Operator s Manual. Table of Contents

ML520G55 FEATURES. Package: φ5.6mm TO-CAN PKG APPLICATION. Reverse voltage

Lawnmowers (pedestrian controlled, battery powered)

Instruction Manual. Self-Leveling Rotary Laser Level Model Nos and

Laser Collimated Beam Sensor

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

USER MANUAL Please read this manual carefully before use!

Laser Safety Self-Audit Checklist

ML562G84 APPLICATION. Display system. Symbol Parameter Conditions Ratings Unit. Pulse (Duty 40%)

6R, 6G 180R, 180G. Users Manual. Point and Line Lasers. Line Laser Levels

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

NLC C61 Air-Cooled Argon-ion Laser

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Operator's Manual. LIGHTNING 2 Laser Detector

LASER SAFETY BARRIER

Only for operating with ATEX certificated sensors DMT 99 ATEX E056/N5 Maximum optical input power Maximum radiation intensity Detection pattern

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

ML501P73 TYPE NAME. FEATURES High Output Power: 1.0W (Pulse) 0.5W (CW) High Efficiency: 1.0mW/mA (typ.) Visible Light: 638nm (typ.) 5.

This document is a preview generated by EVS

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

LaserGuard2. Laser Collision Avoidance System. Part Number: R1 April 2015 Copyright 2015 Magnetek Material Handling

en Inverter FU 4/5. Operator s Manual

Installation and Operation Manual

SAFETY DEVICE 3 WITH VISIBLE LASER EMISSION MSD

Operating Instructions Bühler Infrared Heater POWERCUBE IRB 6. These operating instructions are protected by copyright. Modifications reserved.

TTK 70 S OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK70S-TC-001-EN

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding

Translation of the assembly instructions with operating instructions and technical appendix

Operating Manual. English. Refrigerators for chemicals KRC 50 KRC 180

PERSONAL CUEING DEVICE MODEL NO. BDAAU100 INSTRUCTION MANUAL.

An FT-NIR Primer. NR800-A-006

Analisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH

Prizmatix UV Torch. User Manual

Laser Safety Citations

Flame Simulator User Manual. Publication Rev. A

235L G. Original-Gebrauchsanleitung V1/1115

A. Administrative. B. Labeling and Posting. C. Control Measures. Laser Safety Self-Audit Checklist. Building Room Principal Investigator Date

PROCESSING UNIT II V Hz V Hz. Table of Contents

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

NLC 210 Air-Cooled Argon-ion Laser

ML60171C FEATURES. φ5.6mm TO-CAN PKG (with monitor PD) APPLICATION Motion sensor Printing. Reverse voltage (PD)

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

Test Lamp for 210 series flame detectors Non EX

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

LASER SAFETY PROGRAM

*For inquiries and questions about lasers, see the Yellow-Page.

Laser Safety. This Laser Safety Program applies to the acquisition, use, transfer, and disposal of all Class 3B and 4 lasers at UNC Asheville.

Silicon UVAB Sensor E xxx

Laser Safety Products. Edition 20

SWARCO TRAFFIC SYSTEMS GMBH. TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

G4 Pulsed Fiber Laser

Transcription:

Valid for Hardware SN 100 and higher Ident.-No. 229 750 01 Document Version from 20.11.2008

Table of Contents 1. IMPORTANT NOTES... 3 2. INTENDED USE... 5 3. SAFETY NOTES... 5 4. DESCRIPTION OF THE DEVICE... 6 4.1 Design... 6 4.2 Basic principle... 6 5. INSTALLATION... 7 6. ENVIRONMENT CONDITIONS... 8 7. TECHNICAL DATA... 8 8. SERVICE... 8 CE - Declaration WEEE and RoHS Declaration Ident.-Nr.: 229 750 01 2

1. Important Notes Safety Remarks This equipment must only be used following the instruction manual. Please read the instructions first. It is only allowed to use the equipment in the intended way. The equipment is only for use in clean and dry environment. Also see next paragraph. The valid accident prevention regulations of Employer s for Electrical Systems and Operating Materials and for Laser Radiation are to be observed. Special accident prevention regulations may occur out of the specific use of the instrument and have to be considered. The year of manufacturing and the serial number of the equipment is documented on the identification label. Keep this manual for later use. Safety conditions for operating the Equipment The following conditions are to observe for save operating of the instrument: Only for indoor use. Use only in clean and dry environment. No conductance dirt cover or condensation. Equipment must be adapted to the operating conditions in time to avoid any condensation. Operating Temperature 15-30 C. Humidity less 80% up to 32 C linear decreasing to 50% at 40 C. Height above zero normal not more than 2000 m. Tolerance of mains voltage not above 10% from nominal value. Mains voltage 100-240V~ AC depending on country. Operating the equipment in mains, where transient over voltage peaks exceed the common values (more than allowed according to Over Voltage Class III according to EC664) is forbidden. It is not allowed to cover power supplies, to short-circuit the output or to pull them by cable. Defect or damaged supplies and cables must be disabled and substituted by original MÖLLER-WEDEL OPTICAL spare parts. Power plugs are only allowed to clean with a soft and dry cloth. Before cleaning disconnect them from the main voltage and the equipment. Additional restrictions in use may result of the measurement application and are listed in the technical data. There you will also find other base data. Ident.-Nr.: 229 750 01 3

MAINTENANCE AND CARE Modifications or maintenance must only be carried out by persons explicitly authorised by MÖLLER-WEDEL OPTICAL GmbH. Only original parts of MÖLLER-WEDEL OPTICAL must be used for maintenance. After maintenance or technical modifications the equipment must be re-adjusted according to the technical instructions. In case of technical inquiries the numbers on the relevant parts must be indicated. Before cleaning or maintenance always disconnect from the mains and other equipment Liability to Functions and Damage If the equipment is modified or repaired by not explicitly authorised persons, in case of improper maintenance (as far as not performed by MÖLLER-WEDEL OPTICAL) or in case of improper handling, any liability of MÖLLER-WEDEL OPTICAL is excluded. Accessories Electrically driven accessories are permitted on the equipment only if its technically safe application is documented by a notified person (relevant certificate must be available). The Laser Finder is classified as Laser Class 2. Please observe the valid security regulations. Declaration of Conformity The declarations according to CE, environment and disposal are attached in the end of the manual. Ident.-Nr.: 229 750 01 4

2. Intended Use The laser attachment is designed to simplify the adjustment of telescopes, autocollimators for alignment to mirrors or other flat optical surfaces (prisms, polygons, plan plates). The laser attachment can be used in conjunction with autocollimators and telescopes with a tube diameter of 65 mm/40 mm depending on ordered type. 3. Safety notes The instrument works contains a laser diode. A stickers at the front panel warns that the instrument contains a laser. Danger! Visible Laser Radiation Don t look into the beam! Laser safety class II as per IEC 825 Use only the laser power supply furnished with the laser attachment. Do not attempt to use the laser attachment with any other power supply. Do not use the laser attachment in the height of your head. Ident.-Nr.: 229 750 01 5

4. Description of the device 4.1 Design The laser attachment consists of the laser attachment unit (figure 1) and the power pack. In case of delivery with an ELCOMAT vario or an ELCOMAT 3000 only a power supply cable is supplied. socket for power supply Figure 1: Laser attachment unit 4.2 Basic principle The emitted laser beam of the laser diode is reflected by a plane reflector (mirror, polished glass plate or prism). The mirror or autocollimator to be aligned is adjusted if the emitted beam is reflected into themselves. To achieve it is necessary to tilt either the autocollimator or the mirror. The basic principle is shown in Figure 2. Ident.-Nr.: 229 750 01 6

Objektivrohr Objective tube Laservorsatz Laser attachment reflektierter Laserstrahl reflected laser beam Reflektor, dejustiert Reflector, disadjusted ausgesandter Laserstrahl emitted laser beam Objektivrohr Objective tube Laservorsatz Laser attachment Reflektor, justiert Reflector, adjusted ausgesandter und reflektierter Laserstrahl emitted and reflected laser beam Figure 2: Basic principle of the alignment with the laser attachment 5. Installation Fix the autocollimator in the adjustable holder or in the fixture D65 respectively D40. Connect the power pack with the laser attachment. If used with an ELCOMAT connect the power cable with the laser attachment and with the plug on the rear side of autocollimation head. Set the laser attachment on the objective tube of the autocollimator. It is hold by magnets at the underside. Connect the power pack to power. If used with an ELCOMAT switch on the ELCO- MAT. The laser diode emits a visible laser beam. Mirror or autocollimator to be adjusted have to be adjusted in height and side in such a way that the laser beam strikes the mirror approximately in the center. Tilt the mirror or the autocollimator with holder untill the reflected beam and the emitted beam are superimposed.(figure 3) Ident.-Nr.: 229 750 01 7

MÖLLER-WEDEL A HAAG-STREIT COMPANY MÖLLER-WEDEL A HAAG-STREIT COMPANY Autocollimator respectively mirror misaligned Autocollimator respectively mirror aligned Figure 3: Position of the reflected laser beam in the misaligned and aligned position After alignment of the mirror respectively of the autocollimator disconnect the laser diode from power and take the laser attachment off from the objective tube. 6. Environment conditions Protect the device against droplet water, gush water or sprayed water. Do not use the device in damp rooms. Working temperature: 15...30 C (limited by the laser diode) Storage temperature: -25...55 C 7. Technical Data Laser safety class: Power supply: Laser wavelength: Total length: Inner diameter: Weight II 220 V AC/5...7 VDC with power pack 633 nm 112 mm 65 H7 respectively 40 H7 ca. 0.35 kg (without power pack) 8. Service In principle the laser attachment is free of service and attendance. Please inform immediately MÖLLER-WEDEL OPTICAL when detecting irregularities and defects. MÖLLER-WEDEL OPTICAL or authorized companies will carry out the service. If the lifetime of the laser diode is exceeded, the laser diode can be exchanged at the facilities of MÖLLER-WEDEL OPTICAL. Ident.-Nr.: 229 750 01 8

Ident.-Nr.: 229 750 01 9

Ident.-Nr.: 229 750 01 10