(Information about THERMAL dampers for gas-fired appliances available on request.) WARNING

Similar documents
WARNING FLAIR INTERNATIONAL CORPORATION 600 OLD WILLETS PATH HAUPPAUGE, NEW YORK U.S.A. TEL.: (516) FAX: (516) AMERICAN

SLANT/FIN AUTOMATIC VENT DAMPER For Galaxy, Sentinel and Sentry Series Boilers INSTALLATION INSTRUCTION MANUAL AND TROUBLESHOOTING GUIDE

POWER VENTER. Model: PVE Series

PVE SERIES POWER VENTER SYSTEM MANUAL

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

D896 Automatic Vent Damper

ELECTRONIC FIREPLACE DAMPER

ELECTRONIC FIREPLACE DAMPER

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

POWER VENTER SYSTEM MODEL: PVO-300, PVO-600

Leisure Line Power Vent Operations & Maintenance Manual And Safety Instructions

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Leisure Line Power Vent Operations & Maintenance Manual And Safety Instructions

EUTECTIC EC-10DV Series

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

X341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:

BGH Series Hot Surface Ignition Control

Do not use this vent pipe or fittings for venting incinerators of any kind.

Model Universal Oil Primary Control

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Direct Vent System Required

Indiana WX Oil Furnace Inspection Guide

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

Installation Instructions Remote Blowers

WARNING FIRE OR EXPLOSION HAZARD.

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

SIDEWALL POWER VENTING KIT

LGB Gas fired boiler

TJERNLUND PRODUCTS, INC.

24 VAC SYSTEM CONTROL KIT

COMMERCIAL COMBUSTION AIR IN-FORCER TM MODELS PAI-3 PAI-4 PAI-5 PAI-6 PAI-7

80% and 95% furnace models feature aluminized steel heat exchangers to conduct heat quickly and increase durability.

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

ML180UH SERIES GAS FURNACE WARNING WARNING

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

Bosch 80% AFUE Gas Furnace BGS80 Model

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

Operator: Save these instructions for future use!

POWER VENTER SYSTEM. Model: PVG-100, PVG-300, PVG-600

XIII Troubleshooting

KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO.

Energy Manager INSTALLATION INSTRUCTIONS. Keep these instructions with the boiler at all times for future reference

INSTALLER'S GUIDE MASONRY CHIMNEY VENT KIT WARNING: BAYVENT800B 18- CH23D2-05

Interrupted Ignition Series Oil Primary Control

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

24 VAC SYSTEM CONTROL KIT

INSTALLATION INSTRUCTIONS

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

Installation and Operating Instructions ISH ELECTRIC STEAM SUPERHEATER

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

Operator: Save these instructions for future use!

EG & PEG Series 5 EGH Series 5

EL195UHE SERIES GAS FURNACE WARNING WARNING

EL296UHV SERIES GAS FURNACE WARNING WARNING

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

MGB CAST IRON GAS FIRED BOILERS FOR FORCED HOT WATER With Hydrolevel Control. Models MGB-50J MGB-75J MGB-100J MGB-125J MGB-150J MGB-170J MGB-200J

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER)

Gallery Electric Fireplaces

USER S INFORMATION MANUAL

Second Revision No. 3 implements the text of Committee Input No. 36 as proposed in the First Draft Report, along with the following amendments:

SYSTEM CONTROL KIT. Model: CK-62. Designed for use on SWG Series Power Vent Hoods for controlling oil fired heating appliances with 120 VAC controls.

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

BEST DRAFT CONTROL: MANUAL DAMPERS IN MULTIPLE BOILER SYSTEMS

USER S INFORMATION MANUAL

CSD-1 COMMERCIAL BOILER CONTROLS

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Draft Control D R A F T C O N T R O L G U I D E w w w. f i e l d c o n t r o l s. c o m August 2007

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

INSTALLATION INSTRUCTIONS

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

USER S INFORMATION MANUAL

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

ENERVEX ADC100 DRAFT CONTROL

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Columbia Boiler Company

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

Operator: Save these instructions for future use!

EL195DFE SERIES GAS FURNACE WARNING

Indirect gas-fired air heater

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

Operator: Save these instructions for future use!

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

IN-FORCER TM MODELS PAI-1G & PAI-2G PAI-10 & PAI-2O

User s Information Manual

Owner s Information Manual

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

Transcription:

FLAIR INTERNATIONAL CORPORATION 600 OLD WILLETS PATH HAUPPAUGE, NEW YORK 11788 U.S.A. TEL.: (516) 234-3600 FAX: (516) 234-3610 SPECIFICATIONS, INSTALLATION INSTRUCTIONS AND TROUBLE-SHOOTING GUIDE FOR STACK PACK MOTORIZED VENT DAMPER SERIES SL89 FOR USE ON OIL/GAS FIRED SYSTEMS ONLY. (Information about THERMAL dampers for gas-fired appliances available on request.) WARNING THIS DEVICE MUST BE INSTALLED ONLY ON AN AUTOMATICALLY OPERATED OIL-FIRED APPLIANCE EMPLOYING AN ATOMIZING TYPE BURNER. ALL WIRING MUST BE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODES, CLASS 1 (REMOTE CONTROL AND SIGNALLING CIRCUITS), AND MUST ALSO COMPLY WITH APPLICABLE LOCAL ELECTRICAL ORDINANCES, CODES AND REGULATIONS. "HOT LEG" MUST HAVE A COMMON DISCONNECT AND MUST BE CONNECTED WITH CORRECT POLARITY. FAILURE TO OBSERVE THIS CAUTION MAY LEAD TO ELECTRICAL SHOCK AND-OR EQUIPMENT DAMAGE OR MALFUNCTION. CLEARANCES OF NOT LESS THAN 18 INCHES (457.2 MM) MUST BE MAINTAINED FROM COMBUSTIBLE MATERIALS, WITH PROVISIONS FOR ACCESS. THIS DEVICE MUST BE INSTALLED IN A VENTING SYSTEM OR SECTION OF A VENTING SYSTEM SO THAT IT SERVES ONLY THE SINGLE APPLIANCE FOR WHICH IT IS INSTALLED. INSTALLATION OF THIS DEVICE SHOULD BE PERFORMED BY A QUALIFIED INSTALLING AGENCY IN COMPLIANCE WITH ALL LOCAL, STATE AND FEDERAL CODES. DO NOT REDUCE VENT PIPE SIZE TO ACCOMMODATE THE STACK DAMPER. STACK DAMPER SIZE MUST BE AT LEAST THE SAME SIZE AS OR LARGER THAN ORIGINAL VENT PIPE. DEVIATION FROM THESE INSTRUCTIONS IN INSTALLATION OR USE MAY LEAD TO A DANGEROUS CONDITION. SHOULD INSTALLATION PROBLEMS ARISE, CONSULT THE TROUBLE-SHOOTING GUIDE ON REAR COVER. IF PROBLEMS PERSIST, CALL OUR TECHNICAL SUPPORT LINE AT (516) 234-3600. U.S. PATENTS 4,039,123 / 4,404,613 PRINTED IN U.S.A. 1995 FLAIR INT'L CORP. 90700850

I. INTRODUCTION This product is an automatic, motorized stack damper that has been developed to increase the efficiency of heating systems by reducing standby losses from the heating apparatus and the conditioned air space surrounding it. The damper closes the chimney vent when the burner is off and fully opens it again when combustion is required. The concept is similar to the opening and closing of a fireplace flue, except that the operation is completely automatic. A safety interlock has been added, which prevents burner operation unless the damper is in an open position. A closed damper substantially reduces standby losses on boilers, furnaces and water heaters. Motorized stack dampers are not to be installed on sealed combustion systems or on oil fired appliances having a constant burning pilot. Motorized dampers do not "Reclaim Wasted Heat". Motorized dampers prevent heat from being wasted by the natural draft of the chimney when the burner is off. II. DESCRIPTION The damper should be mounted on the vent pipe directly after, on the chimney side of, the barometric damper for oil systems only. (This is the recommended location for maximum efficiency. If installation difficulties arise, the damper may be installed between the appliance and the barometric damper, resulting in a loss of efficiency.) When the damper is in the closed position, it will prevent residual heat in the heating appliance from being drawn up the chimney vent by its natural draft. A closed damper will also prevent conditioned air from being pulled through the barometric damper and up the chimney by the same stack effect. When combustion is required, the damper will rotate to its open position BEFORE an integral end switch activates the burner circuit. If the damper does not rotate to its open position, the burner circuit will not be activated. If installed properly, the electrical circuits in this product are designed not to override existing limit controls. When the combustion requirement has been satisfied, the burner will go off immediately, and after a three-minute time delay (optional), the damper will slowly rotate to its fully closed position. This delay has been designed to provide a post-purge which reduces nozzle "coking" and eliminates annoying combustion odors. The damper is spring loaded and will return to an open position on power failure. This feature enables the normal stack draft to effectively vent any unburned fumes that may accumulate during the power outage. Aluminum die cast vent section construction allows for close tolerance manufacture and a tight fitting damper blade which gives maximum system efficiency. Potential fuel savings can vary from 10% to greater than 40% based on the following factors: 1. geographical location of dwelling; 2. the size of heating plant relative to heat loss of dwelling; 3. location of heating plant within dwelling; 4. diameter of venting system; 5. total height of chimney above heating plant; 6. outdoor temperature and sustained wind velocities over a given period of time; 7. settings of operating and limit controls on heating plant; 8. type of heating plant used (furnace, boiler or hot water heater); 9. source of domestic hot water, temperature of water, and amout used; 10. room thermostat settings; 11. infiltration factors of dwelling; 12. number of heating zones; 13. day/night thermostat being used, and the hours and degrees of setback; 14. chimney vent friction; 15. type and model of stack damper used. Motorized dampers for oil fired equipment are available through all normal heating distribution channels. Although we have attempted to make field installation simple and safe, a faulty mechanical installation or improper electrical wiring can make the damper inoperative or potentially dangerous. IT IS FOR THIS REASON THAT WE STRONGLY RECOMMEND INSTALLATION BY TRAINED, QUALIFIED HEATING CONTRACTORS OR OIL BURNER SERVICEMEN. When properly installed, the unit is maintenance-free. It is designed to provide many years of dependable service, giving both comfort and economy. III. GENERAL INFORMATION VENT DAMPER VENT SIZE SECTION MATERIAL VANE MATERIAL SHIPPING WEIGHT 4" sand cast aluminum.062 aluminum 2.9 lbs 5" die cast aluminum.062 aluminum 3.2 lbs 6" die cast aluminum.062 aluminum 3.5 lbs 7" die cast aluminum.062 aluminum 3.8 lbs 8" die cast aluminum.062 aluminum 4.1 lbs 9" sand cast aluminum.062 aluminum 5.2 lbs 10" sand cast aluminum.062 aluminum 5.9 lbs 12" sand cast aluminum.062 aluminum 7.3 lbs PAGE 2 STACK PACK SL89 SERIES FLAIR INTERNATIONAL CORPORATION

IV. ELECTRICAL Provide common 110/120 VAC power supply to damper actuator and heating plant, and provide common disconnect means with overload protection as required. Thermostat Anticipator Setting. Set for normal system requirement. Settings do not change with addition of vent damper. MINIMUM WIRING REQUIREMENTS...18 GAUGE, 90 0 C. COPPER WIRE DAMPER DRIVE MOTOR POWER DRAW REQUIREMENT...5 WATTS AT 115 VAC WHEN CLOSED OR CLOSING TORQUE (RUNNING)...20 IN./OZ. MINIMUM AT 97.8 VOLTS TIMING...TO CLOSE, 15 SECONDS (PLUS 3 MINUTE TIME DE- LAY); TO OPEN, 5 SECONDS (NOM.) CHARACTERISTICS...POWER CLOSE, SPRING OPEN TYPE...SYNCHRONOUS SWITCHING...2 PRECISION SNAP ACTING SWITCHES,10.1 AMP RES., 3 AMP IND. AT 125 VAC, 250 VAC P.C. BOARD...2 OZ./FT 2 ONE SIDE COPPER, HEAT RESISTANT, FLAME RETARDANT V. HARNESS DAMPER END APPLIANCE END #1 WHITE #3 RED WIRE SIDE DISREGARD NUMBERS ON RECEPTACLE #2 BLACK #4 BROWN WIRING LEGEND #1 WHITE TO -120 V #2 BLACK TO +120 V #3 RED TO IGNITION #4 BROWN TO PRIMARY CONTROL VI.MECHANICAL Damper vane Drive rod-actuator Mounting plate Actuator cover Maximum allowable stack temperature.062 thick aluminum stainless steel galvanized steel, 14 gauge plastic 930º F above ambient VII. FEATURES Damper opens on power failure - No required change in wiring of existing limit controls - 100,000 trouble-free operations in life cycle test at 1,000 F - Aluminum die cast construction of vent pipe section - 90% open before burner ON signal - Three-minute closing delay after burner OFF (optional) - Burner OFF before start of damper close - Normal burner operations with damper disabled open - No burner operation with damper disabled closed - External damper position indicator - Direct drive, no-linkage end switch for proving damper open - Damper safety circuit disables damper to the open position if damper interlock switch malfunctions closed while maintaining normal burner operation - Free-wheeling lost motion clutch permits free rotation of vane during installation without gear damage - Actuator assembly is replaceable - 5 seconds open does not casue lockout with timed safety controls - Compatible with all cad cell primary controls. FLAIR INTERNATIONAL CORPORATION STACK PACK SL89 SERIES PAGE 3

VIII. DIMENSIONS Vent A B C Size in mm in mm in mm 4" 4.3" 109 6.2" 158 9.3" 235 5" 5.3" 134 6.7" 170 10.3" 260 TOP VIEW DAMPER SHOWN IN CLOSED POSITION B 6" 6.3" 160 7.2" 183 11.3" 286 7" 7.3" 185 7.7" 196 12.3" 311 8" 8.3" 211 8.2" 208 13.3" 337 9" 9.3" 236 8.7" 221 14.3" 362 10" 10.3" 261 9.2" 234 15.3" 387 C A 12" 12.3" 312 10.2" 259 17.3" 438 SIDE VIEW DAMPER SHOWN IN OPEN POSITION CHIMNEY 2.84" (72mm) 4.4" (111mm) IX. INSTALLATION INSTRUCTIONS A. BEFORE YOU START TO INSTALL: 1. Read cautions as listed on cover page. 2. System should be visibly checked for defects such as rusting vent pipe, poor burner adjustment, and oil leaks. Problems should be corrected before proceeding. 3. Turn off electrical power and wait for the system to cool. 4. Select a safe, convenient location allowing a minimum of 18 inches (457.2mm) of clearance between the stack damper and walls, ceilings, floor, or combustible material. (See Fig. 2, 3 and 4). (Installation BETWEEN barometric damper and heating appliance is allowable but will reduce fuel saving efficiency.) 5. Carefully unpack the unit. The damper is spring loaded and should drive to an open position when uit is removed from the packing. DO NOT FORCE IT CLOSED! Forcing the damper may damage the gear train and void the warranty. B. NOW, PROCEED AS FOLLOWS: 1. Separate the vent pipe at the selected installation point and insert the casting. The arrow on the open damper should point in direction of vent gas flow (towards chimney). 2. Reassemble the vent piping. Be sure the casting is well seated. (See Fig. 5 if support or screwtogether assembly is required). 3. Wire the system as shown in the diagrams and in accord with local codes (see diagrams). 4. Restore electrical power. C. AFTER INSTALLATION 1. Operate system through (3) complete cycles to check for opening and closing in proper sequence, and proper hi-limit control of burner operation. (See Fig. 6 for Position Indicator.) REMEMBER, THERE IS A NORMAL THREE MINUTE DAMPER CLOSING DELAY AFTER THE BURNER GOES OFF (optional). 2. If the damper does not come to the fully open or fully closed positions, check for interference by the vent pipe. (See Fig. 6). 3. Check the "trouble-shooting guide" if problems arise with the installation. PAGE 4 STACK PACK SL89 SERIES FLAIR INTERNATIONAL CORPORATION

IMPORTANT THE STEP-BY-STEP INSPECTION AND INSTALLATION PROCEDURES AS SPECIFIED IN EXHIBITS A AND B MUST BE FOLLOWED THE QUALIFIED INSTALLER MUST FILL IN LABEL ON THE SIDE OF THE OPERATOR AN ADEQUATE ELECTRICAL SUPPLY MUST BE PROVIDED EXHIBIT A PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION The following procedure is intended as a guide to aid in determining that an appliance is properly installed and is in a safe condition for continuing use. This procedure is predicated on central furnace, boiler and water heater installations, and it should be recognized that generalized procedures cannot anticipate all situations. Accordingly, in some cases deviation from this procedure may be necessary to determine safe operation of the equipment: (a) This procedure shall be performed prior to installation of the automatic vent damper device. (b) If it is determined there is a condition which could result in unsafe operation, the appliance should be shut off and the owner advised of the unsafe condition. Do not install the automatic vent damper device until the unsafe condition has been corrected. The following steps are to be followed in making the safety inspection: 1. Conduct a gas leakage test of the appliance piping and control system downstream of the shut off valve in the supply line to the appliance. 2. Visually inspect the venting system for proper size, horizontal pitch and vent termination, and determine there is no blockage or restriction, leakage, corrosion and other deficiencies which and could cause an unsafe condition. 3. Determine that the chimney or vent is acceptable to the authority having jurisdiction. 4. Shut off all gas to the appliance and shut off any other fuel-gas burning appliance within the same room. Use the shut off valve in the supply line to each appliance. 5. Inspect burners and crossovers for blockage and corrosion. 6. Applicable only to furnaces - inspect heat exchanger for cracks, openings or excessive corrosion. 7. Applicable only to boilers - inspect for evidence of water or combustion product leaks. 8. Insofar as is practical, close all building doors and windows and all doors between the space in which the appliance is located and other spaces of the building. Turn on clothes dryers. Turn on any exhaust fans, such as range hoods and bathroom exhausts, so they will operate at maximum speed. Do not operate a summer exhaust fan. Close fireplace dampers. If, after completing Steps 9 through 14, it is believed sufficient combustion air is not available, refer to local codes, or in the absence of local codes, to the National Fuel Gas Code, ANSI Z223.1-(most current edition) (NFPA 54), for guidance. 9. Place in operation the appliance being inspected. Follow the lighting instructions. Adjust thermostat so appliance will operate continuously. 10. Determine that the pilot(s), when provided, is burning properly and that main burner ignition is satisfactory by interrupting and reestablishing the electrical supply to the appliance in any convenient manner. If the appliance is equipped with a continuous pilot(s), test the pilot safety device(s) to determine if it is operating properly by extinguishing the pilot(s) when the main burner (s) is off and determining, after 3 minutes, that the main burner gas does not flow upon a call for heat. If the appliance is not provided with a pilot(s), test for proper operation of the ignition system in accordance with the appliance manufacturer's lighting and operating instructions. 11. (a) Visually determine that main burner gas is burning properly; i.e., no floating, lifting or flash-back. Adjust the primary air shutter(s) as required. (b) If the appliance is equipped with high and low flame controlling or flame modulation, check for proper main burner operation at low flame. 12. Test for spillage at the draft hood relief opening after 5 minutes of main burner operation. Use the flame of a match or candle, or smoke from a cigarette, cigar or pipe. 13. Turn on all other fuel-burning appliances within the same room so they will operate at their full inputs. Follow lighting instructions for each appliance. 14. Repeat Steps 11 and 12 on the appliance being inspected. 15. Return doors, windows, exhaust fans, fireplace dampers and any other fuel-gas burning appliances to their previous conditions of use. 16. Applicable only to furnaces - Check both the limit control and the fan control for proper operation. Limit control operation can be checked by blocking the circulating air inlet or temporarily disconnecting the electrical supply to the blower motor and determining that the limit control acts to shut off the main burner gas. 17. Applicable only to boilers - (a) Determine that the water pumps are in operating condition. (b) Test low water cutoffs, automatic feed controls, pressure and temperature limit controls, and relief valves in accordance with the manufacturer's recommendations to determine they are in operating condition. EXHIBIT B PROCEDURE FOR INSTALLING ELECTRICALLY OPERATED AND MECHANICALLY ACTUATED AUTOMATIC VENT DAMPER DEVICES ON EXISTING APPLIANCES This procedure is intended as a guide to aid in safely installing an electrically operated or mechanically actuated automatic vent damper device on an existing appliance. This procedure is based on the assumption that the history of the specific appliance has been one of safe and satisfactory operation. This procedure is predicated on central furnace, boiler and water heater installations, and it should be recognized that generalized procedures cannot anticipate all situations. Accordingly, in some cases deviation from this procedure may be necessary to determine safe operation of the equipment. The following steps are to be followed in making the modifications: 1. Perform a safety inspection of the existing appliance installation. See Exhibit A for the recommended procedure for such a safety inspection. 2. Shut off all gas and electricity to the appliance. To shut off gas use the shut off valve in the supplyline to the appliance. 3. Install the automatic vent damper device in strict accordance with the manufacturer's installation instructions. Make certain the device is not located in that portion of the venting system which serves any appliance other than the one for which the damper is installed. 4. Make certain wiring connections are tight and wires are positioned and secured so they will not be able to contact high temperature locations. 5. When an additional automatic valve has been incorporated or an existing gas control replaced, conduct a gas leakage test of the appliance piping and control system downstream of the shut off valve in the supply line to the appliance. 6. Visually inspect the modified venting system for proper horizontal pitch. 7. Check that the damper and gas valve(s) are in the correct operating sequence. (a) The damper must be in the full open position before the gas valve(s) opens. (b) The damper must remain in the full open position while the gas valve(s) is open. (c) The gas valve(s) must be closed before the damper begins it's return to the closed position. (d) The damper shall remain in the closed position during the off cycle of the appliance. 8. Determine the amperage draw of the gas control circuit and damper device. (a) Check appliance transformer for adequate capacity. (b) Check heat anticipator in comfort thermostat to determine it is properly adjusted. 9. Sequence the appliance through at least three normal operating cycles. 10. Insofar as is practical, close all building doors and windows and all doors between the space in which the appliance is located and other spaces of the building. Turn on clothes dryers. Turn on any exhaust fans, such as range hoods and bathroom exhausts, so they will operate at maximum speed. Do not operate a summer exhaust fan. Close fireplace dampers. 11. Place appliance in operation. Follow the lighting instructions. Adjust thermostat so appliance will operate continuously. 12. Test for spillage at the draft hood relief opening after 5 minutes of main burner operation. Use the flame of a match or candle or smoke from a cigarette, cigar or pipe. 13. (a) Visually determine that main burner gas is burning properly; i.e., no floating, lifting or flashback. Adjust the primary air shutter(s) as required. (b) If the appliance is equipped with high and low flame controlling or flame modulation, check for proper main burner operation at low flame. 14. Determine that the pilot(s), when provided, is burning properly and that main burner ignition is satisfactory by interrupting and reestablishing the electrical supply to the appliance in any convenient manner. If the appliance is equipped with a continuous pilot(s), test the pilot safety device(s) to determine if it is operating properly by extinguishing the pilot(s) when the main burner(s) is off and determining, after 3 minutes, that the main burner gas does not flow upon a call for heat. If the appliance is not provided with a pilot(s), test for proper operation of the ignition system in accordance with the appliance manufacturer's lighting and operating instructions. 15. Applicable only to furnaces - Check both the limit control and the fan control for proper operation. Limit control operation can be checked by blocking the circulating air inlet or temporarily disconnecting the electrical supply to the blower motor and determining that the limit control acts to shut off the main burner gas. 16. Applicable only to boilers - (a) Determine that the water pumps are in operating condition. (b) Test low water cutoffs, automatic feed controls, pressure and temperature limit controls, and relief valves in accordance with the manufacturer's recommendations to determine they are in operating condition. 17. Label the damper device (see 1.7.5) with information as to: (a) Name of qualified agency responsible for damper installation. (b) Date of installation. For continued safe operation, the homeowner should check all flue product carrying areas of the appliance, its vent system, and the damper device at least once a year. Particular attention should be given to the replacement of parts deteriorated by corrosion or other sources. Such replacement must be done by a qualified installing agency, who shall carry out an annual inspection of the appliance-device combination. FLAIR INTERNATIONAL CORPORATION STACK PACK SL89 SERIES PAGE 7

TROUBLE-SHOOTING GUIDE (listed in order of probability) SYMPTOM POSSIBLE CAUSE REMEDY Heating required and burner will not operate. Damper closed. Thermostat is set wrong. Reset room thermostat to call for heat. Heating required and burner will not operate. Damper open. Burner operates normally, damper will not close. Time delay relay chatters (optional). Burner will not operate. Damper closed and will not open. Burner will not operate. Damper operates normally. Burner and damper operate normally. Bad odor is detectable. Burner operates before damper opens. Damper vane stops in other than fully open or fully closed position. Intermittent burner operation. Damper operates normally. Burner operates with damper closed. No electrical power to damper. Stack switch or cad cell malfunction. Defective burner components. Damaged or defective damper actuator. Time delay (optional) in normal operation. Damper is blocked open. Damaged or defective time delay relay. Incompatible solid state oil burner primary control. Robertshaw SJ4000 series. Damaged or defective time delay. No call for heat. Damper is blocked closed. Broken return spring. Stack switch or cad cell malfunction. Defective burner components. Insufficient draft over fire. Normal time delay insufficient for system. Damper is blocked. Broken return spring. Loose or broken wires. Damaged or defective switch. Boiler equipped with tankless coil or low limit and not wired properly. Turn on swtich, replace fuse, reset circuit breaker or repair wiring. Check reset button; repair or replace control. Check, repair or replace burner components. Replace damper actuator. Wait at least 3 minutes for damper to close, before checking further. Check for free damper movement and remove blockage. Replace actuator. The Robertshaw line of solid state primary controls (SJ400 series) are not compatible. Consult factory for wiring modification. Replace damper actuator. Reset thermostat (heat or hot water) to call for heating. Check for free damper movement and remove blockage. Recheck and correct any wiring errors in line and low voltage circuits. Replace actuator. Check reset button; repair or replace control. Check, repair or replace burner conponents. Clean clogged flue passages and readjust barometric damper. Open vent pipe and remove two kock-outs from damper vane. Be careful not to damage or distort vane. Check for maximum 95 damper movement. If less than 90, remove blockage. Check and correct badly fitting vent piping. Inspect under mounting plate for broken return spring. Replace actuator. Recheck and correct any wiring errors in line voltage circuit. Replace damper actuator. Consult factory for required wiring modifications. INSTALLATION AND SERVICE SHOULD BE PERFORMED BY A QUALIFIED INSTALLING OR SERVICE AGENCY. FLAIR INTERNATIONAL 1995 FLAIR AND STACK PACK ARE REGISTERED TRADEMARKS OF FLAIR INTERNATIONAL SL AND SL89 ARE TRADEMARKS OF FLAIR INTERNATIONAL CORPORATION PAGE 8 STACK PACK SL89 SERIES FLAIR INTERNATIONAL CORPORATION