Latest developments in TPO stabilization for Automotive applications ANTEC MAY 8-10 TH 2017 ANAHEIM, CA

Similar documents
Protecting, Coloring and Testing Textile Sports Surfaces

Ci4000. Weather-Ometer. Accelerating Your Expertise. Setting the Standard for Xenon Weathering

ALPHA+ Light Exposure and Weathering Testing Instrument. Xenotest Alpha+ Features. Xenotest Alpha+ Specifications. Sample Capacity

Ci5000. Weather-Ometer. Accelerating Your Expertise. Setting the Standard for Xenon Weathering

Market-Leading Non-Metallic Enclosure Brands

IWASAKI ELECTRIC CO., LTD

ANTEC SUSTAINABILITY OF PVC (VINYL) PIPE: A COMPREHENSIVE ENVIRONMENTAL REVIEW. May 9, 2017

Firestone Reinforced Polypropylene (fpp-r) Geomembrane

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames.

UV Weather Resistance Test Chambers

Overview of UV and EB Technologies

Molekule Produces No Ozone or Other Secondary Pollutants, and Actually Reduces Ozone in the Air.

Horsehead Holding Corporation Relies on XR-5

PERFORMANCE POLYMER SOLUTIONS

Firestone Lining Systems. Dependable Performance in Demanding Environments

Latin American Coatings Show 2017 WACKER Presents Silicones and Polymer Binders for High-Quality Paint and Coating Applications

o Clear instruction for operation o Measurement and control of o Stationary sensor for o Programming capabilities of o Countdown timer selectable

EUROPEAN COATINGS SHOW 2011: WACKER Presents Novel Polymer Dispersions and Alpha-Silanes for Ecologically Sound Adhesives and Sealants

UV Weather Resistance Test Chamber Technical Data

The Growing Viability of UV LED for Wide Web Coating Applications. Tuesday, October 11, 2016

..the International Leader in Thermoplastic Powders for the Protective Coating of Metals

Equipment specifications (D6)

COMPARING PLASTIC STAKING TECHNOLOGIES

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

Durability summary of Saflex Structural interlayer France regulatory compliance

PRESS RELEASE. Number 11

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

JAG group microwave manual. (updated October ) Table of contents. 1 General information 2. 2 General safety rules 2. 3 The microwave reactor 3

Firestone EPDM Geomembrane Review of technical performances

Version: 1603 UV Accelerated Weathering Testers Weice Testing Instrument Co., Limited

State-of-the-Art on the Applications of Geosynthetics for Dam Repair and Rehabilitation

Heat Management Methodology

Pneumatic Tubing POLYTUBING O.D. 5/32"

Type approval qualification of Photovoltaic Modules Procedures and test experiences

Royal Grass. ...for responsible green cities

Real-time Monitoring Technology for Preservation Environment of Archives

The Premium Experience in Plastic Drinkware. Featuring:

The WWA Standard for manufacturing wood windows and window performance

Next Generation Coatings Update on Engineered Siloxane Hybrid Coatings

transport handle gas ballast valve robust design for long life easy to clean integrated oil level window quiet running, minimized vibrations

Woolmark Specification

Fitoclima Pharma. Stability and Photostability Chambers for the pharmaceutical industry

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

DISCOVER KRAIBURG TPE

Firestone GeoGard EPDM Review of Technical Performances

Durability of the Reaction to Fire Performance for FRT Wood Products in Different End Use Applications A Ten Years Report

ISO 7491 INTERNATIONAL STANDARD. Dental materials Determination of colour stability. Produits dentaires Détermination de la stabilité de couleur

FLEXIBLE NON-METALLIC COVERING FOR INDUSTRIAL INSULATION. Specially developed for use in offshore and industrial environments

Developing UV LED Curing Processes for Converting Applications

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Draft for Comment Please comments to Part A(i)

BUREAU OF METEOROLOGY

Food Contact and how we got there for SPE

fresh style. perfect finish. C o l o r I n n o v a t i o n s f o r T o d a y s B e a u t i f u l w i n d o w s

M7100 Pressure Transducer

Shading STRaTEgY BEnEFiTS ManUal ShadES

PRODUCT: SEL-SV-MCQ-O5- K6 VERSION TECHNICAL SHEET 1/5 SAC

PALLET CARD PROGRAM LABORATORY REPORT

AASHTO s National Transportation Product Evaluation Program (NTPEP) Evaluation Program for Plants Producing Geotextiles. Pre-Audit Application Form

MIDDLE EAST COATINGS SHOW 2017 WACKER Launches New Polymeric Binders for Adhesives and Construction Applications

Henkel Automotive Display Solutions

Page 1 - MAINTENANCE OIL

Flame Retardant Polyethylene Tubing

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

UV LED Curing: The Time is Now

TUFFAK polycarbonate. A new generation of engineered sheet products for signage

HEAT SHRINK CABLE ACCESSORIES: A 40 YEARS PROVEN TECHNOLOGY FOR APPLICATIONS IN HARSH ENVIRONMENTS

Daniels Professional Plant Food. Pansy Study

Automatic Cyanoacrylate Fuming Chamber 24 33T 60T 72XL. Safely Detect Quality Latent Prints and Reproducible Results

Douglas Gray -Sales Director

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Sample Preparation Solid Phase Extraction Disks Cartridges. Horizon Technology, Inc. Salem, NH USA

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

THE ROLE OF DESICCANT IN INSULATING GLASS

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T

How The Air Oasis Air Purifiers Work The Air Oasis Mini, 1000, 3000, 3000 Xtreme, 5000 Commercial and Air Oasis Induct air purifiers utilize a

Modern Consumer Laundry Will Protecting the Environment Protect our Clothes? Vikki B. Martin Cotton Incorporated

ADDITIVES & PLASTICS INDUSTRY COLORS FOR THE BUILDING & CONSTRUCTION PRODUCT RANGE

OPERATION MANUAL Model 800 Nanoimprint Controller

Coil coated metals Test methods

LiteEarth Advanced Synthetic Grass Geomembrane Liner INDEPENDENT THIRD PARTY PERFORMANCE TESTING REPORT. U.S. Patent No.

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

Bernd Eichler Sales Manager

SCREEN VISION SV 3% KOOLBLACK TM

SYSTEM DATA SHEET Sikafloor MultiDur ES-44 ESD

GEA Niro drying systems. We know what makes outstanding polymers. engineering for a better world. GEA Process Engineering

Improving Productivity, Quality and Security

Certificate of Compliance

SCOPE OF ACCREDITATION

Secador Automatic Desiccator. vs. Comparable Competitor

Fire resistance testing of technical cabinets in accordance with EN

Durability of a Polypropylene Woven Geotextile under Climatic and Chemical Agents

PRODUCT DATA SHEET (ver.04/ )

Benefit from our experience and competence Application-focused solutions from UV to IR

testing corrosion resistance to the limit Cyclic Corrosion Test (CCT) Chambers

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

A measured step forward

D DAVID PUBLISHING. 1. Introduction. Dr. Vivek Ganesh Bhartu

A Look at General Cable s GenFree II Product Line

Transcription:

Latest developments in TPO stabilization for Automotive applications ANTEC MAY 8-10 TH 2017 ANAHEIM, CA Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2103

2 ATR Segment sub-segmentation applications Requirements Exterior Interior Low VOCs Low discoloration LS LTHS Non-blooming Aesthetics LS Paintability LTHS Non-blooming Aesthetics Under the Hood Low VOCs LTHS Non-blooming Aesthetics SPE ANTEC Anaheim 2017 / 2104

3 ATR sub-segmentation Featured AddWorks solutions Interior Exterior AddWorks ATR 945 for LS of PP AddWorks ATR 146 for LS and LTHS of PP AddWorks LXR 355 for LS of PP Under the Hood AddWorks LXR 568 for LTHS of PP SPE ANTEC Anaheim 2017 / 2105

Interior Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2106

Interior PP ADDWORKS ATR 945 Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2107

6 AddWorks ATR 945 AddWorks ATR 945 - Main features Light stability acc. OEMs Automotive interior standards Oven ageing at 150 C SPE ANTEC Anaheim 2017 / 2108

AddWorks ATR 945 MAIN FEATURES Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2109

8 AddWorks ATR 945 for PP Compounds AddWorks ATR 945 is a low molecular weight hindered amine light stabilizers (LMW HALS) solution specially developed to provide outstanding UV protection to PP compounds AddWorks ATR 945: Outstanding UV protection High stabilization efficiency thanks to its high compatibility with non-polar polymer substrates Lowers side effects like blooming, migration and VOC (volatile organic compounds) emission from PP compounds Reduced odor High resistance to extraction by water or detergent solutions Exceptional handling form SPE ANTEC Anaheim 2017 / 2110

9 AddWorks ATR 945 Color & Appearance before and after storage Competition (MB with same HALS) ATR 945 (Pill) ATR 945 (Micro granule) Initial After storage stability test After 1 day stored in oven 50C SPE ANTEC Anaheim 2017 / 2111

Solubility (g/100 ml) 10 AddWorks ATR 945 Compatibility in PP / Solubility in n-heptane 0.3 Solubility of Samples in n-heptane 0.25 0.2 0.15 0.1 AddWorks ATR 945 Pills AddWorks ATR 945 Micropills LS 3853 PP 0.05 0 1 2 3 Equilibration time (days) Solubility in n-heptane (at 25 C) AddWorks ATR 945 Pills : 0.238 g/100 ml AddWorks ATR 945 Micropills : 0.231 g/100 ml LS 3853 PP : 0.015 g/100 ml SPE ANTEC Anaheim 2017 / 2112

AddWorks ATR 945 LIGHT STABILITY ACCORDING OEMS AUTOMOTIVE INTERIOR STANDARDS SAE J-1885 Toyota Std PSA D 47 1431 PV 1303 Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2113

Delta E 12 AddWorks ATR 945 Light stabilization according SAE J 1885 std. 0.40 Light stability acc. SAE J1885 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 Dark grey - 0.25% LS 3853 Dark grey - 0.25% ATR 945 Dark grey - 0.15% ATR 945 300 hr 600 hr 791 hr 1000 hr SPE ANTEC Anaheim 2017 / 2114

ΔE 13 AddWorks ATR 945 Light stabilization according Toyota Std 0.14 ΔE of samples after ageing according to Toyota standard - TSM0501G 0.12 0.10 0.08 0.06 0.04 0.02 0.00 0.3% AddWorks ATR 945 - Lab Trials 0.3% AddWorks ATR 945 - Ind. Trials 250 hr 500 hr 750 hr 1000 hr Medium gray PP impact copolymer SPE ANTEC Anaheim 2017 / 2115

14 AddWorks ATR 945 Light stabilization according PSA D 47 1431 0.30 Delta-E of PP plaques (black) after WOM ageing 900 hours 0.20 0.10 150 h 300 h 750 h 900 h 0.00 0.2% AddWorks ATR 945 0.2% LS 3853 PP + 14% talc - black SPE ANTEC Anaheim 2017 / 2116

Gray scale 15 AddWorks ATR 945 Light stabilization according PV 1303 6 Gray scale of PP before and after PV 1303 test 5 4 3 2 0 cycle 3 cycles 5 cycles 1 0 LS 3808 AddWorks ATR 945 Formulations Black PP-EPDM-T20 Addition rate 0.2% SPE ANTEC Anaheim 2017 / 2117

ATR 945 PV 1306 (TACKINESS) Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2118

17 Tackiness properties evaluation PV 1306 standard Tackiness : By hands of the persons (average rating) Tackiness properties evaluation according to PV 1306 standard Level Tackiness properties 1 OK S Dull (exudation, but not tacky) 2 Slightly tacky 3 Tacky 4 Very tacky H Resinified W Waxy X Test cancel, specimens crack The samples were exposed on the side of smooth surface and evaluated on color change, grey scale assessment, gloss and tackiness as well as surface cracking after 4 cycles or 56 MJ or 384 hrs and 6 cycles or 84 MJ or 576 hrs. SPE ANTEC Anaheim 2017 / 2119

Gray scale 18 AddWorks ATR 945 Light aging for tackiness test 6 Gray scale of PP before and after PV 1306 test 5 4 3 2 0 cycle 4 cycles 6 cycles 1 0 LS 3808 AddWorks ATR 945 Formulations Black PP-EPDM-T20, smooth surface Addition rate 0.2% SPE ANTEC Anaheim 2017 / 2120

19 AddWorks ATR 945 Tackiness results after light treatment (PV 1306 test) Time Tackiness rating after PV 1306 test Reference AddWorks ATR 945 Initial 1 (OK) 1 (OK) 4 cycles 1 (OK) 1 (OK) 6 cycles 1 (OK) 1 (OK) SPE ANTEC Anaheim 2017 / 2121

AddWorks ATR 945 HEAT STABILITY AT 150 C Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2122

de 21 AddWorks ATR 945 Heat ageing test at 150 C 5.000 Delta E of PP plaque (grey) after oven ageing at 150 ºC for 750 hours 4.000 3.000 150h 300h 450h 600h 2.000 750h 1.000 0.000 0.3% AddWorks ATR 945 0.3% LS 3853 0.3% LS 3808 Formulation *Samples burned and brittled after 750 hr (Stopped exposing) SPE ANTEC Anaheim 2017 / 2123

22 AddWorks ATR 945 Conclusion AddWorks ATR 945 is a light stabilizer solution designed as highly compatible and efficient for PP compounds to meet specific requirements of automotive applications. AddWorks ATR 945 brings PP compounds to pass OEMs standards for light stabilization of PP Automotive Interior compounds. AddWorks ATR 945 enhances heat stabilization of PP Automotive Interior compounds at 150 C till 600 hours. AddWorks ATR 945 is available in special handling forms beads and micropills to allow an ideal distribution in the compound. SPE ANTEC Anaheim 2017 / 2124

Interior PP ADDWORKS ATR 146 Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2125

24 AddWorks ATR 146 AddWorks ATR 146 - Main features Light stabilization according PV 1303 exposure Oven ageing at 150 C SPE ANTEC Anaheim 2017 / 2126

AddWorks ATR 146 MAIN FEATURES Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2127

26 AddWorks ATR 146 Heat and Light stabilizer for Latest Automotive PP Interior challenges AddWorks ATR 146 allows to fulfil the most stringent Automotive interior requirements, especially on long term heat stabilization No surface cracking after 700 hours @ 150 C Contains no sulfur-based co-stabilizer AddWorks ATR 146 Outstanding UV protection Reduced VOC emissions Very low blooming High compatibility with PP High resistance to extraction media likewater or detergents Ready-to-use, granulated free flowing form NB: The whole study was conducted on a PP interior grade, medium gray colored, 20% talc filled. SPE ANTEC Anaheim 2017 / 2128

AddWorks ATR 146 LIGHT STABILITY ACCORDING AUTOMOTIVE INTERIOR STANDARD PV 1303 Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2129

ΔE 28 AddWorks ATR 146 Light stabilization according PV 1303 0.2 ΔE of PP plates after PV 1303 test 0.15 0.1 0.05 3rd cycle 5th cycle 8th cycle 10th cycle 0 0.2% LS 3808 0.2% ATR 146 SPE ANTEC Anaheim 2017 / 2130

Gloss unit 29 AddWorks ATR 146 Light stabilization according PV 1303 45 Gloss of PP plates before and after PV 1303 test 40 35 30 25 20 15 10 0 cycle 3rd cycle 5th cycle 8th cycle 10th cycle 5 0 PP no stab. 0.2% LS 3808 0.2% AddWorks ATR 146 AddWorks ATR 146 provides similar performance on color stability, gloss retention and surface protection in PP interior than LS 3808 after 10 cycles of PV 1303 test. SPE ANTEC Anaheim 2017 / 2131

AddWorks ATR 146 LONG TERM HEAT STABILIZATION AT 150 C Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2132

31 AddWorks ATR 146 Surface appearance at 150 C after 700 hr Material Formulation (0.3%) Samples No stab. LS 3808 AdddWorks ATR146 Surface Cracking YES YES NO Brittleness YES YES NO Blooming NO NO NO SPE ANTEC Anaheim 2017 / 2133

32 AddWorks ATR 146 Appearance after oven ageing at 150 C 0.3% AddWorks ATR 146 0.3% LS 3808 700hr 1000hr Exposure was stopped due to breaking of sample SPE ANTEC Anaheim 2017 / 2134

33 AddWorks ATR 146 Surface cracking after oven ageing at 150 C 0hr 400hr 700hr 50X magnifications 0.3% AddWorks ATR 146 0.3% LS 3808 AddWorks ATR 146 provides better performance on surface protection in PP interior than LS 3808 after 700 hr oven ageing at 150 o C. SPE ANTEC Anaheim 2017 / 2135

ΔE 34 AddWorks ATR 146 Discoloration (ΔE) of PP plate after oven ageing at 150 C 30 ΔE of PP after oven ageing at 150ºC 25 20 15 10 200hr 400hr 700hr 5 0 Formulations AddWorks ATR 146 provides better performance on color stability in PP interior than LS 3808 after 700 hr oven ageing at 150 o C. SPE ANTEC Anaheim 2017 / 2136

Gloss unit 35 AddWorks ATR 146 Surface quality after oven ageing at 150 C Gloss of PP plate after oven ageing at 150 C 45 40 35 30 25 20 15 0hr 200hr 400hr 700hr 10 5 0 0.2% LS 3808 0.2% AddWorks ATR 146 Formulations AddWorks ATR 146 provides better performance on surface quality in PP interior than LS 3808 after 700 hr oven ageing at 150 o C. SPE ANTEC Anaheim 2017 / 2137

36 Conclusion ATR 146 AddWorks ATR 146, all-in-one, complies with most stringent OEM requirements in heat and light stability and beyond: - Outstanding color retention under UV test - Exceptional heat resistance at 150 C (700 hours+) - 10 % lower total carbon emissions from PP parts when compared to best alternative Sulfur-free product Low VOC emissions Long lasting surface aesthetics SPE ANTEC Anaheim 2017 / 2138

Under the Hood Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2139

Under the Hood PP ADDWORKS LXR 568 Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2140

39 AddWorks LXR 568 AddWorks LXR 568 LTHS 140 C AddWorks LXR 568 LTHS 150 C SPE ANTEC Anaheim 2017 / 2141

AddWorks LXR 568 LONG TERM HEAT STABILIZATION AT 140 C Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2142

41 AddWorks LXR 568 - Oven ageing at 140 C Surface Appearance of PP plates according PS class No PS PS 168 PS 626 PS 9228 AddWorks LXR 568 Initial 1440 hours AddWorks LXR 568 allows better surface protection under oven ageing test at 140 C compared to other PS classes materials. BS: PP + 0.1% AO 1010 + 0.1% PS + 0.2% Hostanox SE 4 (DSTDP) + 20% Talc SPE ANTEC Anaheim 2017 / 2143

L* 42 AddWorks LXR 568 Surface quality of PP plates under oven ageing at 140 C 90 L* of PP plates before and after oven ageing at 140 C 80 70 60 50 40 30 Initial 30 days 60 days 20 10 0 No PS PS 168 LXR 568 PS 626 PS 9228 Formulations Formulation: PP + 0.1% PS + 0.1% AO 1010 + 0.2% Hostanox SE 4 + 20% Talc SPE ANTEC Anaheim 2017 / 2144

AddWorks LXR 568 LONG TERM HEAT STABILIZATION AT 150 C Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2145

44 AddWorks LXR 568 - Oven ageing at 150 C Surface Appearance of PP plates according PS class No PS PS 168 PS 626 PS 9228 AddWorks LXR 568 Initial 600 hours 720 hours Samples were broken before 720 hours AddWorks LXR 568 allows better surface protection under oven ageing test at 150 C compared to other PS classes materials. BS: PP + 0.1% AO 1010 + 0.1% PS + 0.2% Hostanox SE 4 (DSTDP) + 20% Talc SPE ANTEC Anaheim 2017 / 2146

YI 45 Color retention of PP plates before and after oven ageing at 150 C 140 YI of PP plates before and after oven ageing at 150 C 120 100 80 60 Initial 600 hours 40 20 0 No PS PS 168 LXR 568 PS 626 PS 9228 Formulations Formulation: PP + 0.1% PS + 0.1% AO 1010 + 0.2% Hostanox SE 4 + 20% Talc SPE ANTEC Anaheim 2017 / 2147

Strength (MPa) 46 AddWorks LXR 568 Mechanical properties retention at 150 C Strength at break of PP plates before and after oven ageing at 150 C 50 45 40 35 With LXR 568, still >50% retention after 600 hours 30 25 20 15 10 5 0 Sample was broken before 600 hours No PS PS 168 LXR 568 PS 626 PS 9228 Formulations 0 480 hours 600 hours Formulation: PP + 0.1% PS + 0.1% AO 1010 + 0.2% Hostanox SE 4 + 20% Talc SPE ANTEC Anaheim 2017 / 2148

47 AddWorks LXR 568 Conclusion AddWorks LXR 568 show superior performance on color stability and mechanical properties retention in PP compound vs most common processing stabilizers in long term heat stabilization of talc filled PP compounds. AddWorks LXR 568 shows better appearance than PS 168, PS 626 and PS 9228 after oven ageing at 140 C reaching 1500 hr. AddWorks LXR 568 shows better appearance than PS 168, PS 626 and PS 9228 after oven ageing at 150 C reaching 600 hr. SPE ANTEC Anaheim 2017 / 2149

Exterior Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2150

Exterior PP ADDWORKS LXR 355 Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2151

50 AddWorks LXR 355 AddWorks LXR 355 - Light stabilization of PP compounds AddWorks LXR 355 - Heat stabilization of PP compounds SPE ANTEC Anaheim 2017 / 2152

AddWorks LXR 355 LIGHT STABILIZATION OF PP COMPOUNDS Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2153

Grey scale 52 AddWorks LXR 355 Light Stabilization (Exposure acc. to Renault Ext. Std) 6 5 Grey scale of PP after WOM ageing 4 3 2 1 0 hr 1500 hrs 3500 hrs 4500 hrs 6000 hrs 0 0.3% LS 3808 0.3% AddWorks LXR 355 Formulations AddWorks LXR 355 reveals exceptional performance on color retention during light exposure tests, with grey scale still above 4 after 6000 hours of Exterior artificial weathering Study on black exterior PP exterior SPE ANTEC Anaheim 2017 / 2154

Grey Scale 53 AddWorks LXR 355 Light Stabilization (Exposure according to PV 1303) 6 Grey Scale before and after 10 period (2800 kj/m²) for WOM ageing 5 4 3 2 Initial 6 period 10 period 1 0 LS F-0 3808 AddWorks F-1 LXR 355 Formulations AddWorks LXR 355 reveals also excellent performance on color retention according most stringent interior artificial weathering tests. Study on PP copolymer / 30% EPR, 20% talc, 0.4% CB, 0.4% AO 215, 0.3% LS SPE ANTEC Anaheim 2017 / 2155

AddWorks LXR 355 HEAT STABILIZATION OF PP COMPOUNDS Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2156

Grey scale 55 AddWorks LXR 355 Oven ageing at 150 C - Color retention (Grey scale) 5.5 Grey scale of PP before and after thermal ageing 150ºC 5 4.5 4 3.5 3 initial 200hr 400hr 2.5 2 1.5 1 LS 3808 AddWorks LXR 355 Formulations Study on PP copolymer / 30% EPR, 20% talc, 0.4% CB, 0.4% AO 215, 0.3% LS SPE ANTEC Anaheim 2017 / 2157

de 56 AddWorks LXR 355 Oven ageing at 150 C - Color retention (Delta E) 0.9 ΔE* of PP before and after thermal ageing 0.8 0.7 0.6 0.5 0.4 200hr 400hr 0.3 0.2 0.1 0 LS 3808 AddWorks LXR 355 Study on PP copolymer / 30% EPR, 20% talc, 0.4% CB, 0.4% AO 215, 0.3% LS SPE ANTEC Anaheim 2017 / 2158

57 AddWorks LXR 355 Oven ageing at 150 C - Surface appearance Initial 400 hours LS 3808 50 x Magnification AddWorks LXR 355 Bending test (Brittleness test after 400 hr oven ageing at 150 o C) LS 3808 AddWorks LXR 355 Brittle OK SPE ANTEC Anaheim 2017 / 2159

58 AddWorks LXR 355 Conclusion AddWorks LXR 355 reveals the best performance on color stability, surface cracking protection and mechanical stability after thermal treatment and also artificial weathering. Cracks and brittleness observed in sample stabilized with competitor LS 3808 system after 400 hours thermal treatment. AddWorks LXR 355 provides superior surface protection with no crack and no brittleness after both treatments, thermal and artificial weathering. Clariant AddWorks LXR 355 provides superior light and thermal stability to fulfill market needs in Automotive Exterior PP compounds. SPE ANTEC Anaheim 2017 / 2160

Conclusion Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2161

60 Potential benefits along the value chain with the right additives solution MB / Compounders Flowability of highly filled compounds Better pigment dispersion Converters Productivity Dimensional stability Energy saving Surface appearance OEMs Light stabilization Durability Color stability Aesthetics SPE ANTEC Anaheim 2017 / 2162

Back-up OEM STANDARDS Public Emilie Meddah Clariant BU Additives Technical Marketing Polymer Additives 24.01.2017 SPE ANTEC Anaheim 2017 / 2163

62 TOYOTA Interior parts TSM0501G Instrument : Atlas Weathering O-meter (WOM), Model Ci65A (Xenon-arc Artificial Weathering Exposure Test) Parameters Radiation filter Value 340 nm Light or Dark Light Irradiance 0.55 W/m 2 Black Temperature Chamber Temperature 89 C 62 C Relative Humidity 50% Exposure Time and Interval : Taking sample at 250, 500, 750 and 1043 hr (equivalent to 2065 KJ/m2). SPE ANTEC Anaheim 2017 / 2164

63 VW PV 1303 - Non-Metallic Materials Exposure Test of Passenger Compartment Components Instrument : Atlas Weathering O-meter (Xenon-arc Artificial Weathering Exposure Test) Parameters Radiation filter Light or Dark Value 420 nm Light Irradiance 1.20 W/m 2 Black Temperature 100 ± 3ºC Chamber Temperature 65 ± 3ºC Relative Humidity 20% The samples were exposed on the side of grain surface and evaluated on color change and grey scale assessment as well as surface cracking after 3 cycles or 840 kj/m² or 195 hrs and 5 cycles or 1400 kj/m² or 325 hrs. Grey scale is permitted as per ISO105-A02 4.0 and no cracks or holes may appear after 5 cycles SPE ANTEC Anaheim 2017 / 2165

64 PSA - Accelerated exposure for automotive interior materials Instrument: Atlas weathering-o-meter (WOM), Model Ci 4000 (Artificial Weathering Exposure Test) Parameters Radiation filter Light or Dark Value 340 nm Light Irradiance 1.20 W/m 2 Black Temperature 100 ± 3ºC Chamber Temperature 66 ± 3ºC Relative Humidity 30% Exposure time and interval: Every 150 hr until 600 hr SPE ANTEC Anaheim 2017 / 2166

65 SAE J-1885 (Automotive Interior) Instrument : Atlas Weathering O-meter, Model Ci 4000 (Xenon-arc Artificial Weathering Exposure Test) Parameter Value 1 Value 2 Segment number 1 2 Light or Dark Light Dark Irradiance 0.55 W/m 2 0 W/m 2 Black Temperature 89 C 38 C Chamber Temperature 62 C 38 C Relative Humidity 50% 95% SPE ANTEC Anaheim 2017 / 2167

66 RENAULT - D27 1911 (Exterior parts) Instrument : Atlas Weathering O-meter (Xenon-arc Artificial Weathering Exposure Test) Parameter Value 1 Value 2 Segment number 1 2 Light or Dark Light Dark Irradiance 0.55 W/m 2 0 W/m 2 Black Temperature 70±2 C 70±2 C Chamber Temperature 50±2 C 50±2 C Relative Humidity 50% 95% The samples were evaluated on color change and grey scale assessment as well as surface cracking at 1500h, 2250h and 2750h and 3500 h SPE ANTEC Anaheim 2017 / 2168