Say Goodbye to your old flickering fluorescent tubes. Say HELLO to the new tube-free Claris LED Retrofit Kit. [think outside the tube.] 10 YEAR WARRAN T Y Copyright LED Living Technology. All rights reserved.
how to Use This Guide The Claris LED Retrofit Kit is designed with versatility and customer-driven solutions in mind (Section B); based on experience and performance data, we have also put together a list of our recommendations as a guide to building your kit (Section A). Section A BUILD-YOUR-KIT RECOMMENDATION HUB An express route to choosing your Claris LED Retrofit Kit. Use this Guide to find manufacturer-recommended replacements for existing systems in standard 2 x2, 2 x 4, and 1 x4 direct recessed troffer housings. Section B 2 x2 Direct Recessed Troffers pages 3-4 FL T8 2 Lamp F17T8 3 3 Lamp F17T8 4 2 Lamp FB32T8 U-Bend 4 FL T12 2 Lamp F20T12 3 3 Lamp F20T12 4 2 Lamp FB34/FB40 T12 U-Bend 4 2 x4 Direct Recessed Troffers pages 5-7 FL T8 2 Lamp F32T8 5 3 Lamp F32T8 5 4 Lamp F32T8 6 FL T12 2 Lamp 34/40T12 6 3 Lamp 34/40T12 7 4 Lamp 34/40T12 7 1 x4 Direct Recessed Troffers page 8 FL FL T8 T12 1 Lamp F32T8 8 2 Lamp F32T8 8 2 Lamp 34/40T12 8 BUILD-YOUR-OWN-KIT GUIDE This section is for the explorers. Free your mind, and discover the wide versatility and modularity of the Claris LED Retrofit Kit design. Kit Performance Tables 9 Exploring Kit Modularity 10 Disclaimer: LED Living Technology is not responsible for the accuracy of recommendations included in this guide, as they are based on field experience and generalized troffer characteristics - meant to be used as suggestions. We encourage users to contact LED Living Technology representatives for lighting layouts in regards to their specific project needs. ledlivingtechnology.com I Claris LED Retrofit Kit I 1
CLARIS LED RETROFIT KITS Revolutionary By Design modularity. Discover the world of possibilities made open to you with LED Living Technology's patent-pending Think Outside The Tube design. controllability. Increase your energy savings with 0-10V dimming and daylighting capabilities. performance. Let us show you what Quality of Light means, with up to 130 lm/w, 86 CRI, Rapid Thermafuse Technology, and Isotropic Diffusion. Advanced LED Technology Think Outside The Tube THERMAL MANAGEMENT I Rapid Thermafuse Technology. Proper thermal management plays the biggest role in LED lifetime. Patent-pending Rapid Thermafuse Technology works to transfer heat from the LEDs to the existing fixture housing, which acts as an effective heat dissipator. This technique results in LED core temperatures of only 5-10º above room temperature and an LED lifetime exceeding 168,000 hours. LED Strip Rapid Thermafuse Technology Existing Housing Rapid Thermafuse Technology provides a freeway for heat dissipation from the LEDs to the existing housing. Because Precise Means Efficient. Not only are LEDs a more efficient light source 2, but when their precise directional nature is designed for correctly, they can illuminate the same space equally or better than alternate light sources with fewer lumens. Deliver illumination where it counts: with Isotropic Diffusion, LEDs are diffused as they leave the housing, ensuring minimal light loss and making the most out of your LED technology. Standard Lens Isotropic Lens LEDs CONTROLLED OPTICS Say goodbye to the pinprick glare associated with LEDs. With nearly two decades of experience in LED applications, LED Living Technology takes glare management to the next level with Isotropic Diffusion. Lightweight, isotropic diffuser lens sits on top of existing prismatic lens, generating evenly diffuse and comfortable imaging 1. isotropic diffusion NEA Non-Rigid Beam-Shaping Isotropic Lens notes 1 Claris Retrofit Kits utilizing the technologies above are patent pending. 2 Claris Rapid Thermafuse strips feature up to 130 lumens/w. 10 YEAR WARRAN T Y All Content Copyright LED Living Technology. All rights reserved. ledlivingtechnology.com I Claris LED Retrofit Kit I 2
2'x2' direct recessed Section A Section A of this Guide is a ready-made recommendation hub for choosing a Claris LED Retrofit Kit configuration, based on your existing system. Navigate this section by Housing Type and Fluorescent Lamp Type (T8 or T12). FL I T8 / T12 2 Lamp F17T8 / F20T12 Recommended Claris LED Replacement Kit ( ) CLA-22-2-UNV-DW-1K 22 2 2500 lm CLA-30-4-UNV-DW-1K 30 4 3720 lm CLA-34-4-10D-DW-1K 34 4 3927 lm ledlivingtechnology.com I Claris LED Retrofit Kit I 3
direct recessed 2'x2' FL I T8 / T12 3 Lamp F17T8 / F20T12 Recommended Claris LED Replacement Kit [0-10V Dimming/Daylighting] () CLA-22-3-UNV-DW-1K 22 3 2700 lm CLA-22-2-UNV-DW-1K 22 2 2500 lm CLA-30-3-UNV-DW-1K 30 3 3540 lm CLA-34-3-10D-DW-1K 34 3 3729 lm 2 Lamp FB32T8 / FB34T12 / FB40T12 U-Bend Recommended Claris LED Replacement Kit Model () CLA-30-4-UNV-DW-1K 30 4 3720 lm CLA-30-3-UNV-DW-1K 30 3 3540 lm CLA-22-2-UNV-DW-2K 44 4 5000 lm CLA-34-4-10D-DW-1K 34 4 3927 lm ledlivingtechnology.com I Claris LED Retrofit Kit I 4
2'x4' direct recessed FL I T8 2 Lamp F32T8 Recommended Claris LED Replacement Kit QTY. () CLA-30-4-UNV-DW-1K 30 4 3720 lm CLA-22-4-UNV-DW-1K 22 4 2860 lm CLA-22-2-UNV-DW-2K 44 4 5000 lm CLA-34-4-10D-DW-1K 34 4 3927 lm 3 Lamp F32T8 Recommended Claris LED Replacement Kit () CLA-22-3-UNV-DW-2K 44 6 5400 lm CLA-22-2-UNV-DW-2K 44 4 5000 lm CLA-60-6-UNV-DW-1K 60 6 7080 lm CLA-60-6-10D-DW-1K 60 6 7080 lm ledlivingtechnology.com I Claris LED Retrofit Kit I 5
direct recessed 2'x4' FL I T8 4 Lamp F32T8 Recommended Claris LED Replacement Kit MAXIMUM OUTPUT OPTION [Highest output option, Improves upon Quality of Light ] () CLA-60-8-UNV-DW-1K 60 8 7440 lm CLA-60-6-UNV-DW-1K 60 6 7080 lm CLA-34-4-10D-DW-2K 68 8 7854 lm CLA-60-8-10D-DW-1K 60 8 7440 lm FL I T12 2 Lamp F34T12 / F40T12 Recommended Claris LED Replacement Kit () CLA-22-4-UNV-DW-1K 22 4 2860 lm CLA-30-4-UNV-DW-1K 30 4 3720 lm CLA-34-4-10D-DW-1K 34 4 3927 lm ledlivingtechnology.com I Claris LED Retrofit Kit I 6
2'x4' direct recessed FL I T12 3 Lamp F34T12 / F40T12 Recommended Claris LED Replacement Kit () CLA-22-3-UNV-DW-2K 44 6 5400 lm CLA-22-2-UNV-DW-2K 44 4 5000 lm CLA-60-6-UNV-DW-1K 60 6 7080 lm CLA-60-6-10D-DW-1K 60 6 7080 lm 4 Lamp F34T12 / F40T12 Recommended Claris LED Replacement Kit () CLA-22-4-UNV-DW-2K 44 8 5720 lm CLA-22-2-UNV-DW-2K 44 4 5000 lm CLA-60-8-UNV-DW-1K 60 8 7440 lm CLA-60-8-10D-DW-1K 60 8 7440 lm ledlivingtechnology.com I Claris LED Retrofit Kit I 7
direct recessed 1'x4' FL I T8 / T12 1 Lamp F32T8 / F34T12 / F40T12 Recommended Claris LED Replacement Kit () CLA-22-2-UNV-DW-1K 22 2 2500 lm CLA-30-4-UNV-DW-1K 30 4 3720 lm CLA-34-4-10D-DW-1K 34 4 3927 lm 2 Lamp F32T8 / F34T12 / F40T12 Recommended Claris LED Replacement Kit () CLA-30-4-UNV-DW-1K 30 4 3720 lm CLA-22-4-UNV-DW-1K 22 4 2860 lm CLA-22-2-UNV-DW-2K 44 4 5000 lm CLA-34-4-10D-DW-1K 34 4 3930 lm ledlivingtechnology.com I Claris LED Retrofit Kit I 8
Section B Section B of this Guide is for those who want to explore the vast potential & flexibility of the CLARIS LED Retrofit Kit. Using the performance tables below for single and doubled kits along with your imagination, generate the best kit to replace your existing system, whatever it may be. For standard retrofitting recommendations, refer to Section A of this Guide (p.3). Think Outside The Tube. Finally -- there is a modular and versatile fluorescent replacement solution that offers unprecedented lifetime, efficacy, ease of installation, and affordability: effectively redefining the LED Retrofit Kit. Tables below indicate strip performance specifications and light levels for the various Claris LED Retrofit Kits, both single and doubled. Please request Claris LED Retrofit Kit Data Sheets for further info regarding lifetime, payback, driver performance, polar plots, etc. Please note that the "Doubled Kit" Table below shows the specs for 2 Single Kits installed in one housing. For Doubled Kits, use a 2K designator at the end of your model # upon ordering (see page 11). 1 When ordering a Single Kit, one kit is installed in each existing housing. Requires a 1K designator in upon ordering (pg. 11). 2 When ordering a Doubled Kit, two Single Kits are installed in one housing. Requires a 2K designator in upon ordering (pg. 11). efficiency Go Ahead, Think Outside The Tube KEY CRI STRIPS MODEL quickest ROI SINGLE CLA-22 22 2 11 114 2500 Kit (1K) 1 3 7.33 123 2700 4 5.5 130 2860 CLA-30 30 3 10 118 3540 4 7.5 124 3720 CLA-34* 34 3 11.33 113 3729 4 8.50 119 3927 CLA-60* 60 6 10 118 7080 MODEL WATTAGE TOTAL WATTAGE Up to 86 CRI for all kits Size: 21.3" length, 1" width, 0.11 lbs # OF STRIPS 8 7.5 124 7440 TOTAL # OF STRIPS WATTS/STRIP WATTS/STRIP DOUBLED CLA-22 44 4 11 114 5000 Kit (2K) 2 6 7.33 123 5400 8 5.5 130 5720 CLA-30 60 6 10 118 7080 8 7.5 124 7440 CLA-34* 68 6 11.33 113 7458 LM/W LM/W TOTAL LUMENS TOTAL LUMENS 8 8.50 119 7854 Note: LED Living Technology maintains a tolerance of +/- 6% for all measurements. All Content Copyright LED Living Technology. All rights reserved. *0-10V Controllable for Dimming & Daylighting To ensure LED lifetime and efficacy, maximum /Strip = 11.5 ledlivingtechnology.com I Claris LED Retrofit Kit I 9
/ sample kit configurations / KEY: Indicates Doubled Kit options and the corresponding additional driver. CLA-22-2-UNV-XX-1K CLA-22-3-UNV-XX-1K CLA-30-3-UNV-XX-1K CLA-34-3-10D-XX-1K CLA-22-4-UNV-XX-1K CLA-30-4-UNV-XX-1K CLA-34-4-10D-XX-1K CLA-22-4-UNV-XX-1K CLA-30-4-UNV-XX-1K CLA-34-4-10D-XX-1K CLA-22-2-UNV-XX-2K CLA-22-3-UNV-XX-2K CLA-30-3-UNV-XX-2K CLA-34-3-10D-XX-2K CLA-60-6-UNV-XX-1K CLA-60-6-10D-XX-1K 2 x2 Troffer 2 x4 Troffer CLA-22-4-UNV-XX-2K CLA-30-4-UNV-XX-2K CLA-34-4-10D-XX-2K CLA-60-8-UNV-XX-1K CLA-60-8-10D-XX-1K CLA-22-4-UNV-XX-1K CLA-30-4-UNV-XX-1K CLA-34-4-10D-XX-1K CLA-22-2-UNV-XX-2K CLA-22-2-UNV-XX-1K CLA-22-2-UNV-XX-1K Wrap Light flexi bility 1x4 Troffer CLA-22-4-UNV-XX-1K CLA-30-4-UNV-XX-1K CLA-34-4-10D-XX-1K CLA-22-2-UNV-XX-2K CLA-22-4-UNV-XX-2K CLA-30-4-UNV-XX-2K CLA-34-4-10D-XX-2K CLA-60-8-UNV-XX-1K CLA-60-8-10D-XX-1K 1 x8 Troffer 2 x2 Direct-Indirect Troffer Explore. The Claris LED Retrofit Kit is the most versatile fluorescentreplacement LED Retrofit Kit on the market a door opener for specifiers looking to embrace LED in a way that best supports their performance and energy savings needs. CLA-22-4-UNV-XX-2K CLA-30-4-UNV-XX-2K CLA-34-4-10D-XX-2K CLA-60-8-UNV-XX-1K CLA-60-8-10D-XX-1K CLA-22-4-UNV-XX-1K CLA-30-4-UNV-XX-1K CLA-34-4-10D-XX-1K CLA-22-2-XX-UNV-2K CLA-22-4-UNV-XX-1K CLA-30-4-UNV-XX-1K CLA-34-4-10D-XX-1K CLA-22-2-UNV-XX-2K CLA-22-2-UNV-XX-1K flexibility. ledlivingtechnology.com I Claris LED Retrofit Kit I 10 All Content Copyright LED Living Technology. All rights reserved.
Ordering CLA - 30-4 - UNV - DW - 1K Claris LED Retrofit Kit ordering: Quantity MODEL # ROOT of Rapid DRIVER/ Thermafuse VAC Input COLOR TEMP. KITS PER HOUSING Root Driver LED Color Temp Kits Per Housing CLA 22-2 - 22W, 2 Rapid Thermafuse 22-3 - 22W, 3 Rapid Thermafuse 22-4 - 22W, 4 Rapid Thermafuse 30-3 - 30 W, 3 Rapid Thermafuse 30-4 - 30 W, 4 Rapid Thermafuse 34-3 - 34W, 3 Rapid Thermafuse (Dimming Only)* 34-4 - 34W, 4 Rapid Thermafuse (Dimming Only)* 60-6 - 60 W, 6 Rapid Thermafuse (Dimmable)* 60-8 - 60 W, 8 Rapid Thermafuse (Dimmable)* *Please Note: Only 34 and 60 Watt Kits are compatible with a 10D Driver designator, for dimming Lens ordering: UNV - Uni-Volt 120-277 VAC (On/Off) 10D* - Dimmable 0-10V Uni-volt 120-277 VAC *Please Note: Dimming (10D) is only available for 34W and 60W Kits WW - Warm White 3000K DW 4000K (Standard) CW - Daylight White - Cool White 5000K 3500K - 3500K Root Glare Management Lens Additional Lens Lens Size CLA NB - Nea Beam-Shaping Isotropic Lens [Standard], 0.033" thickness for Prismatic Lens overlay OF - Opalescent Film (non-rigid), 0.010" thickness (For Parabolic/Egg-Crate Conversion Only) OP TP - Opalescent Diffuser (rigid), 0.110" thickness - Traditional Prismatic Diffuser, 0.100" thickness TT - Thick Prismatic Diffuser, 0.125" thickness Blank - Do Not Include Additional Lens 1K - Single Kit 2K - Doubled Kit 22A - 22 1/4 X 22 1/8 22B - 22 3/4 X 22 3/4 14A - 46 1/2 X 10 1/2 14B - 47 3/4 X 11 3/4 24A - 46 1/2 X 22 1/4 24B - 47 3/4 X 23 3/4 XXX - CUSTOM OPTICS / diffusers All Claris LED Retrofit Kits come equipped with an isotropic non-rigid beam shaping lens. Isotropic lenses can be paired with the existing diffuser (prismatic, parabolic, etc). For a more modern feel, try our nonrigid Nea Opalescent Diffuser. CLA-NB Isotropic Beam-Shaping Lens (For overlaying with existing Prismatic Diffuser) RECYCLES EXISTINGHOUSING CLA-OF Opalescent Film Glare Management Lens (For overlaying with existing Parabolic/Egg-Crate Louver) SAMPLE ORDER #: 1 st Line Item (Kit): CLA-34-4-10D-DW-1K 2 nd Line Item (Lens): CLA-NB-22B Before ordering your Claris LED Retrofit Kit, consult your local LED Living representative to discuss options relative to your project. Please also reference the data sheet for your kit to find complete model specifications including CRI, driver performance, polar plots, etc. All Content Copyright LED Living Technology. All rights reserved. LLT 140002R2 LED Living Technology 211 Sinclair Rd. Suite 100 I Bristol, PA, USA 19007 I p: 215.633.1558 I e: sales@ledlivingtechnology.com I 11