DX2002 OPERATING AND PROGRAMMING INSTRUCTIONS

Similar documents
PRODUCT INFORMATION IMPORTANT SAFETY INFORMATION PROGRAMMING MAINTENANCE TROUBLESHOOTING PARTS LIST WIRE DIAGRAMS

Models Product Information. Important Safety Instructions REV

User Guide. Color Touchscreen Programmable Residential Thermostat. ComfortSense Model: 13H /2015 Supersedes 7/2015

ComfortSense 7500 Thermostat. User Guide

HELPY QUICK-TL GSM INTL

Digital Programmable

BURGLAR ALARM PANEL BS-468

ComfortSense 7500 Commercial Thermostat. User Guide

Owner s Manual. Part Number 33CSCPACHP-01

T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

User Manual. Dryer Controller M720

Programmable Load Management Thermostat

Elegance. SMT-700 User manual. Ver

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V

DYGIZONE GJD910 Lighting Controller & Enunciator

Modbus RTU RS485 Manual

Version 1.03 January-2002 USER S MANUAL

T7350 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

SmarTemp Control fx 2.0

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON

Watchguard WGAP864 User Manual

GSM RFID VOICE Alarm System

Memcom Emergency Telephone

1F97-51 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 7-Day Programmable Electronic Digital Thermostat

USERS GUIDE. Electronic Timer, 7 day. LOGIC+ Combi, LOGIC Combi & LOGIC Combi E 24, 30, 35

Energy Plannersm Programmable Thermostat Customer Guide. Take control of your comfort and energy savings

SC Installation, Operation & Application Guide

Dryer Controller M720

Drayton Digistat +3RF

Destiny Destiny Owners Manual

Instruction manual. Aluminium radiator with ceramic heart. Smart Electric Heaters

Customer Information Pack

CONTENTS. Backup Batteries

Summit 3208GLD USER MANUAL. Electronics Line

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

Operating Manual. Series Touchscreen Programmable Demand Control Thermostat. UtilityPRO TM

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Product Manual SZ1009

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

AUS. Devireg TM 535 Installation and user manual

Installation and User Instructions

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology )

INITIALIZATION / INSTALLATION

EasyTech.One Temperature Controller for Pellet Burner

COMMERCIAL WASHERS MODELS T-300/350/400/450/600/650/750/900/950/1200/1450 VENDED C-SERIES CONTROL

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

PHASE COIN USER S MANUAL

Sensor Control Panel

Programmable Load Controller USER S GUIDE

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

Installation, Start-Up, and Operating Instructions

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Using the QRAE Plus personal multigas monitor

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

ALARM SYSTEM USER S MANUAL Rev

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

FreezeAlarm Dialer Pro

Each reader connected to the Challenger LAN system is programmed as an Arming Station.

Smart Temp. Model

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad.

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

BURGLAR ALARM PANEL BS-468/A

SAS6000UTK-7 UNIVERSAL THERMOSTAT

EXPERT TRI-STAR. Temperature controller. User s Manual

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

VCM-X / RNE Controller Operator Interface SD Technical Guide

On initial power up the thermostat will guide you through set up procedure for the following:

Installation Guide. ECL Comfort 210, application A Table of Contents

VIDEO CONTROLS LIMITED

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

ETN1000/MIGA - Operating manual

Pioneer Z100 Smart Thermostat Operating and Installation Manual

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System. Quick-Start Installation Guide

Contents. Glossary

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

Z100 Pioneer 2 Smart Thermostat Operating and Installation Manual

Product Manual SZ1022/SZ1031/SZ1035/

FreezeAlarm. General Description FA-D /FA-D-AAB. Applications. Features. Specifications. Dimensions

Installation, Start-Up, and Operating Instructions

Operating Manual PU-27 Control Panel

The Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will

Operation 8085C ENGLISH. Customer Support: or Visit our webiste Printed in China

INSTALLATION AND OPERATION MANUAL ISM-4081 INTEGRATED SHUTDOWN MODULE

Operating your heating system with the Prefect PRE5701 Programable Thermostat

Owner s Manual. Part Number 33CS250-01

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

Installation, Operating and Maintenance Manual

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Transcription:

DX2002 OPERATING AND PROGRAMMING INSTRUCTIONS The four pushbuttons located at the bottom right of the circuit board are used to do all programming. Each button has more than one function. Alternate Settings Exit Alternate Schedule Adjust down View Inventory Adjust up Standard Settings Next Item Set Clock S1 S2 S3 S4 S1 is used to exit to standby while in programming or to enter alternate schedule program settings. S2 is used to adjust down or to enter alternate schedule time settings. S3 is used to adjust numbers up or to view inventory. S4 is used to advance to next menu item, to enter standard program settings and to set clock. PROGRAMMING To enter standard program settings press S4. Timer will display standard settings and then show menu item 1. To enter alternate schedule settings press S1. Timer will display alternate settings and then show menu item 1. MENU ITEMS Default values are shown. Menu items are the same for standard program settings and alternate schedule program settings. Some menu items are explained in more detail later in the instructions. 1. COIN Monetary value of one coin pulse. Adjustable from 0.05 to 5.00 $.25 Hold S4 to turn dollar sign off and on. 2. COIN Time per coin. Adjustable from 0:01 to 9:59. 00:30 3. START Number of coins to start. Adjustable from 1 to 200. 008 COINS 4. AUX Pulse multiplier for auxiliary input. Adjustable from 1 to 80. 04 COINS 5. BONUS Coins until bonus. Bonus time is issued when this coin is deposited. 009 COINS 6. BONUS Amount of time added when bonus coin is received. 00:00 Adjustable from 00:00 to 99:59. 7. BONUS Single or multiple bonus. SINGLE 8. DEBIT Debit mode, Credit mode. MODE 9. DELAYED Delayed start (2 second) or instant start. START

10. HORN Length of warning horn at one minute of time remaining. 00:10 Adjustable from 00:00 to 00:59 11. HORN Pulsed or continuous. Horn sounds for amount of time set above or PULSED horn is on continuous for the entire last minute. 12. RE-START Enable or disable 25 second courtesy time. DISABLED 13. WELCOME Welcome message choice. Standard, User or Mix. STANDARD 14. WASHDOWN Length of wash down cycle using remote control. 05:00 Adjustable from 0:01 to 10:00. 15. PASSWORD Remote control password. 1 2 3 4 16. LANGUAGE Choice of language for welcome message. English, Spanish or Both. ENGLISH 17. DIMMING Auto dimming mode. Preset for the led blocks on the circuit board. Do not reset. 1 18. EXIT Timer exits to standby. INVENTORY Timer keeps a running count of coins deposited, auxiliary input pulses and manual cycles. To display inventory press S3. Timer will display INVENTORY then COINS 0000 (number of coin pulses since last cleared). S4. Timer will display AUX 0000 (number of pulses on auxiliary input). S4. Timer will display MANUAL 0000 (number of manual cycles used since last cleared). ing S4 again will show either CLEAR INV? or RESET TO DEFAULT?. This is used to either reset all inventories to zero (CLEAR) or reset all timer programming to factory defaults (RESET). If there are counts in any inventory CLEAR INV? will appear if inventories have been cleared RESET TO DEFAULT? will appear. Bonus Time Settings Amount of time set in bonus time is added to time remaining on timer when bonus coin pulse is received. Bonus is disabled by setting bonus tome to 00:00. If SINGLE BONUS is selected, bonus time is only added once, when bonus coin pulse is received. Any coins deposited after that bonus coin will receive the regular time per coin. If MULTIPLE BONUS is selected, every coin deposited after bonus coin pulse is reached will receive amount of time set in BONUS TIME. Debit/Credit Mode: Debit Mode: As coins are deposited display shows $1.75 MORE, $1.50 MORE, $1.25 MORE etc. until start price is reached. Once start price is reached display switches to time accumulating until no more coins have been deposited. Credit Mode: As coins are deposited display shows money accumulating ($.25, $.50, $.75 etc.). If timer is also set to Delayed Start Mode timer will continue to show money accumulating until no more coins have been deposited. If timer is set to Instant Start mode, as soon as start price is reached, timer will change to time counting down. If start price is not reached, after 5 seconds timer will alternate between ADD $X.XX MORE and amount of money already deposited.

Auxiliary Input The auxiliary input allows for the connection of a second coin acceptor or a bill validator to the timer. The AUX COINS menu item acts as a pulse multiplier for this input. For example, if you are using a bill validator with this input and a dollar bill puts out one pulse and a coin pulse is worth $0.25 then the AUX COINS would be set to 004. If the validator sends 4 pulses for a dollar bill then AUX COINS would be set at 001. The timer keeps a separate inventory of pulses received by this input. Credit Card Input: Credit card input is either standard or serial. If timer is serial version, all credit card functions are controlled, via serial interface, by credit card system. Standard model modes: Count up mode: No pre-set amount is charged to card. Timer will count up and run until terminated by credit card system. For count up: Close pin #9 (input) to 24 VAC common for more than 400ms. Timer will continue to count up until closure is released for more than 400ms. To have timer display amount charged to card at end of cycle: Close input as above. Credit card system sends a string of pulses to timer equal to the number of coins that timer would require in order to reach the amount of time used when customer stops cycle. Pre-pay mode: A pre-determined amount is charged to credit card each time card is swiped and credit card system sends pulses to input. Pulses between 16ms and 200ms will register on timer like coin pulses. A pulse between 200ms and 400ms will cause timer to display VERIFYING CARD. Should a second pulse of 200ms to 400ms be received on input timer will display TRY DIFFERENT CARD. Minimum time between pulses is 16ms. Note: Not all credit card systems can utilize all modes of operation. Contact your credit card system manufacturer for more information on what your system can do. Messages Choices If welcome is set to standard the following messages will be displayed. Standard greeting message (English): PLEASE DEPOSIT $2.00 TO START. Standard greeting message (Spanish): POR FAVOR DEPOSITO $2.00 PARA EMPEZAR Standard exit message (English): THANK YOU Standard exit message (Spanish): GRACIAS If welcome is set to user the custom message that you have programmed will be displayed. If welcome is set to mix the standard message and the custom message will be displayed. Dimming Mode The DX2000 has a unique built in dimming feature that allows the display to be as bright as possible under different lighting conditions without being uncomfortable to look at (i.e. more ambient light means brighter display, less ambient light means dimmer display).

Custom Message Programming A custom message of up to 128 characters may be programmed into the DX2000. Characters available for message programming include upper and lower case letters, numbers and standard keyboard symbols. The character V represents a variable, and the character E represents the end of the message. You must use this character at the end of the message. Variables are used in messages so that the message will automatically change when changes are made to timer programming. Following is variable menu and what the timer will show when they are used. COST OF BONUS - Timer will display the dollar amount needed to reach the bonus time. BONUS TIME - Timer will display the amount of time given as a bonus. BONUS TOTAL - Timer will display the total amount of time that will be shown on timer when bonus time is reached. TIME PER COIN - Timer will display the time per coin. COIN VALUE - Timer will display the monetary value of one pulse. START COST - Timer will display the amount of money needed to start wash. START TIME - Timer will display the amount of time needed to start wash. CLOCK - Timer will display the time of day. DAY OF WEEK - Timer will display day of week (sun-sat). DATE - Timer will display the date. (1-31). MONTH - Timer will display the month (1-12). YEAR - Timer will display the year (2000-2099). Caution: when using the date as part of the message you must program a character such as / or - between the variables in order for the date to display correctly. To program a custom message: S4 to enter standard settings. S4 until the welcome message menu item is displayed. Use S3 to select either USER or BOTH. and hold S4 until E appears on right side of display. Use S2 or S3 to select the first letter of your message. S4 to advance to the next space (the first letter will move to the left). Use S2 or S3 to select the second letter of the message. Continue in this manner until the complete message has been programmed. Push S4 to advance to the next space, push either S2 or S3 to select the letter, number, symbol, or variable required in that space. Note: If using a variable, with V displayed on the timer, pushing S4 will display variable menu so that you may use S2 or S3 to select variable required in that space. Pushing S4 after selecting variable required will advance you to the next space. Remember - you must use E to signify the end of the message.

Custom Message Example To program timer to read: Deposit $2.00 to Start or $5.00 for 20:00. Push S4 until message standard appears on display. Use S3 to select user. and hold S4. Timer will display E on right side of display. S2 or S3 until D appears on right side of display. S4. D will move to the left. S2 or S3 until e appears on right of display. S4. S2 or S3 until p appears on right of display. S4. S2 or S3 until o appears on right of display. S4. S2 or S3 until s appears on right of display. S4. S2 or S3 until i appears on right of display. S4. S2 or S3 until t appears on right of display. S4. S2 or S3 until V appears on right of display. S4. S2 or S3 until start cost appears on display. S4. S2 or S3 until t appears on right of display. S4. S2 or S3 until o appears on right of display. S4. S2 or S3 until S appears on right of display. S4. S2 or S3 until t appears on right of display. S4. S2 or S3 until a appears on right of display. S4. S2 or S3 until r appears on right of display. S4. S2 or S3 until t appears on right of display. S4. S2 or S3 until o appears on right of display. S4. S2 or S3 until r appears on right of display. S4. S2 or S3 until V appears on right of display. S4. S2 or S3 until cost of bonus appears on display. S4. S2 or S3 until f appears on right of display. S4. S2 or S3 until o appears on right of display. S4. S2 or S3 until r appears on right of display. S4. S2 or S3 until V appears on right of display. S4. S2 or S3 until bonus total appears on display. S4. S2 or S3 until E appears on right of display. (If not there already). S1. Timer will display welcome user. S1 timer will return to standby. Message programming is now complete. The above example assumes the following timer programming settings: Time per coin = 00:30, Start Coins = 008, Bonus Coins = 020, Bonus = 10:30.

ALTERNATE SCHEDULE The DX2000-2 contains an alternate schedule program allowing for the timer programming to change automatically at a pre-determined time for a specified length of time. ALTERNATE SCHEDULE PROGRAMMING For the alternate schedule to work correctly three sections in the timer must be set - alternate settings, clock settings, and alternate schedule. ALTERNATE SETTINGS S1. Timer displays ALTERNATE SETTINGS then menu item 1. Menu items for alternate settings are the same as standard settings and are programmed in the same manner. S4 to advance from item to item. S2 or S3 to adjust settings for that item. CLOCK SETTINGS Hold S4. Timer displays CLOCK SETTINGS then YEAR 20XX. S2 or S3 to adjust year. S4. Timer displays MONTH. Use S2 or S3 to set month. S4. Timer displays DATE. Use S2 or S3 to set date. S4. Timer displays DAY. Use S2 or S3 to set day of week. S4. Timer displays CLOCK XX:XX. Use S2 or S3 to set time of day. S1. Timer exits to standby. ALTERNATE SCHEDULE S2 to enter alternate schedule menu. Display will show ALTERNATE SCHEDULE then SUNDAY 12: PM. This represents the day of the week and the time of day that the alternate schedule will start. S2 or S3 to set the hour (12:00 PM is noon 12:00 AM is midnight). S4. The will change to 00. press S2 or S3 to set the minutes. S4. Display will show SUNDAY 00 HOURS. this represents the length of time, in hours, that the alternate settings will be in effect (adjustable from 00 to 24). S2 or S3 to adjust the number of hours. S4. Timer will display MONDAY 12: PM. S2 or S3 to set the hour. Continue in this manner until days of week and duration of alternate settings have all been programmed. S1 to exit menu and return to standby. EXAMPLE: To run an overnight special Monday-Thursday from 7:00PM to 7:00am. Set alternate schedule start time for Monday, Tuesday, Wednesday, and Thursday for 7:00 PM. Set Monday, Tuesday, Wednesday, and Thursday hours to 12. All other day s settings can be left at default settings. SPECIAL NOTES FOR ALTERNATE SCHEDULE PROGRAMMING If an alternate schedule start time is reached during a wash cycle, the timer will wait until cycle is complete before changing to alternate settings. If an alternate schedule overlaps into the next day, that day s alternate schedule start time will override the previous day s settings. For example: Alternate settings are set to activate on Tuesday at 2:00 PM and last for 24 hours, but the settings for Wednesday are still at the default settings of 12:00 PM start time for a duration of 0 hours. Because the time overlaps, the alternate settings would deactivate at 12:00 PM instead of 2:00 PM. To have this example work, Wednesday s start time would need to be set to 2:00 PM. If time does not overlap, it is not necessary to change the next day s settings.

INFO-KEY PROGRAMMING With the optional info-key, it is not necessary to program each timer individually. Simply program one timer, then transfer program to the info-key. The info-key can then be used to program the remaining timers. TRANSFERRING PROGRAM FROM TIMER TO INFO-KEY Insert info-key into receptacle on lower right side of timer circuit board. Timer will automatically detect info-key and display INFOKEY DETECTED then INFOKEY 2=RD 3=WR. S3. Timer will display WRITING TO KEY then DONE then INFOKEY 2=RD 3=WR. Programming is now complete. Remove info-key from receptacle. Timer will return to standby. TRANSFERRING PROGRAM FROM INFO-KEY TO TIMER Insert info-key into receptacle on lower right side of timer circuit board. Timer will automatically detect info-key and display INFOKEY DETECTED then INFOKEY 2=RD 3=WR. S2. Timer will display READING FROM KEY then DONE then INFOKEY 2=RD 3=WR. Remove info-key from receptacle. Timer will return to standby with new program.

REMOTE CONTROL OPERATION Remote control will hold program for 15 minutes without batteries to allow you to change batteries without reprogramming remote. If remote loses its program for any reason use the following instructions. 1. Hold down the set button until the red LED blinks twice, and then release the button. 2. 0000. Remote is now ready to use. WASHDOWN red power button. Display will show PASSWORD 0000. Enter your four digit remote access code. Timer will show OK if correct. red power button on remote control. Timer will display :00 and start counting up. Timer will continue to run until wash down cycle length is reached or cycle is stopped by operator. To stop cycle press red power button. INVENTORY red power button. Display will show PASSWORD 0000. Enter your four digit access code. Timer will show OK if correct. VOL + on remote. Timer will display INVENTRY then COINS 0000. This represents the number of coin pulses received by timer. coin input. on remote. Timer will display AUX 0000. This represents the number of pulses received on auxiliary on remote. Timer will display MANUAL 0000. This represents the number of manual cycles. on remote. If inventories have not previously been cleared, timer will display CLEAR INV? Should you wish to reset all inventories to 0000, press and hold until display shows DONE. If inventories have been reset to 0000, timer will display RESET TO DEFAULT?. and hold at this point if you wish to reset all timer programming to default values. to return timer to standby. Note: timer will display OK for 5 seconds before returning to standby. TIMER PROGRAMMING red power button OK if correct.. Display will show PASSWORD 0000. Enter your four digit access code. Timer will show To enter STANDARD SETTINGS menu press VALUE $. 25. that item. to move to the next item, press VOL + or at any time to return to standby.. Display will show STANDARD SETTINGS then COIN to adjust setting or make selection for To enter ALTERNATE SETTINGS menu press. Display will show ALTERNATE SETTINGS then COIN VOL + VALUE $.25. to move to the next item, press or to adjust setting or make selection for that item. at any time to return to standby. To enter ALTERNATE SCHEDULE menu press. Display will show ALTERNATE SCHEDULE then VOL + SUNDAY 12: PM. to move to the next item, press or to adjust setting or make selection for that item. at any time to return to standby. To enter CLOCK SETTINGS menu, HOLD. Timer will display CLOCK SETTINGS then YEAR 20XX. to move to the next item, press VOL + or at any time to return to standby. to adjust setting or make selection for that item. Note: When exiting any of the menus when using the remote control timer will display EXIT then OK for 5 seconds before returning to standby. This allows you to enter a different menu without having to re-enter the access code. Remember: Use selection for that menu item. Holding to move from item to item in the menus. Use VOL + or VOL + or to adjust settings or make a will cause numbers to move up or down faster.

TIMER WIRING PIN # FUNCTION 1 Coin Common 2 Coin Switch 3 No Connection 4 Horn Negative 5 Horn Positive (12 VDC) 6 24 VAC Common 7 24 VAC Hot 8 Auxiliary Input 9 Credit Card Input 10 Future Use 11 Future Use 12 24 VAC Timed Load 1 2 3 4 5 6 7 8 9 10 11 12 Coin Common Coin Switch Not Used Horn Neg Horn Pos 24 VAC Common 24 VAC Hot Auxiliary Input Credit Card Input Not Used Not Used 24 VAC Timed Load To Coin Acceptor 12 VDC Horn To Bill Validator To Rotary Switch or Relay Transformer COIN ACCEPTOR WIRING 1 2 3 4 5 6 7 8 9 10 11 12 Blue Black Yellow Violet (not used) Slugbuster or Secure Coin 1 2 3 4 5 6 7 8 9 10 11 12 red/green red/green Black Yellow 4 wire Sensortron or IDX