Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Similar documents
Flexible Power Cable DLO

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES

Power Control Cable Iec

SECTION ELECTRICAL GENERAL PROVISIONS

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

A Look at General Cable s GenFree II Product Line

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

Catalogue Power Cables

CONNECTION SYSTEMS TRANSIT APPLICATIONS

AFC Cable Systems: the Cable Industry Leader for Over 80 Years

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Brand Portable Power Cord & Control Cable Solutions

Thermocouple Cable TRANSMITTING, SENSING, MEASURING

Second Revision No. 601 NFPA [ Section No [Excluding

Belden Infinity C-TC+ Cables for Extreme Flexing

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

Catalogue. Instrumentation & Control Cables

Fire Alarm/Life Safety Cable 6

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

Home Theater Cables. Your complete solution for high-end audio transmission, stereo, professional audio systems and home theater systems.

Comtran Cable. Hub-LINK Cables for Transit Applications

Flame Retardant Overall Screened Instrumentation Cables (multicore)

PRODUCT CATALOGUE Norröna

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Multi-Core Fire Resistant Cable

PAIRED UNJACKETED. Insulation Nominal Anixter. Paired Conductors Thickness O.D. Number AWG Strand No. IN IN

Caledonian Flame Retardant Coaxial Cables

BS /1000V XLPE Insulation LSZH Sheath Cables

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

(800) 292- omnicable.com CABLE ACCESSORIES GUIDE

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

APPENDIX C REGULATORY AGENCIES AND INDUSTRY STANDARDS 1.0 APPLICABLE GOVERNMENT CODES AND REGULATIONS

Class 1E Cable Qualification to the Latest IEEE Standards

5. Identification products.

Compact Module. Category 6A FTP Cabling System 1.1

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

High Performance LSZH Fire Resistant Cable

Application and Use of Distributed Temperature Sensing (DTS) Technology in Transmission Cables

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

Your Partner for Custom Interconnectivity Solutions. ISO 9001:2008 AS9100C:2009 ISO 13485:2003 ISO 17025:2005 Qualified

Sensor and transducer cables

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

Fire Alarm Cables. Features: Countdown. New Labeling System on box. Color Coded Boxes. Zone and Room Markings

SECTION (16140) - WIRING DEVICES

Security & Control Cables

Company Profile. We are dedicated to providing our customers competitive price and excellent service.

Honeywell Cable & Custom Electronics

SHIELD TYPE MULTICONDUCTOR MULTIPAIR

ASSOCIATIONS AND REFERENCE STANDARDS

SAS Security and Alarm Safety Cables

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

FIRE RESISTANT CABLES

MINING CABLES POWER YOUR MINE WITH TF KABLE

OIL & GAS INDUSTRY OTHER INDUSTRIES

Caledonian Fire resistant Coaxial Cables

SOUND/SECURITY FIRE ALARM/LIFE SAFETY TEMPERATURE CONTROLS COAXIAL DATACOM HARDWARE FIBER OPTIC SPECIAL APPLICATION CATALOG, VOL.

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

Industrial Wire and Cable Solutions Line Card

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

NEMA Standards Publication WC Standard for Controlled Impedance Shielded Twisted Pairs in Internal Electrical Cable

Catalogue Telecommunication Cables INTRODUCCIÓN

DuraLife TM FPL. Installation Guide. UL 2196 Fire Rated Alarm Cables. Authorities Having Jurisdiction should be consulted before installation.

ELECTRICAL SPECIFICATIONS

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

TYPE APPROVAL CERTIFICATE

Not For General Distribution. For Committee Ballot 4053 Use Only. Draft 6: 10/07/2016

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

AlarmLine Addressable Linear Heat Detector

TECK-40 Series 1000V Class Splice for 4/C Armored Teck Power Cables

electronic wire pocket-picker edition 7/06 Low voltage electronic wire specialists

Installing Protectowire Linear Heat Detector

THE MYSORE UNIT OF RPG CABLES MANUFACTURES A RANGE OF INSTRUMENTATION CABLES

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION

. SECTION CONTROL-VOLTAGE ELECTRICAL POWER CABLES

LOW VOLTAGE SPLICES & TAPS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Understanding Etched Foil Flexible Heaters

DIVISION 16. ElECTRICAl

CABLES FOR ALARM AND SAFETY SYSTEMS

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

Transcription:

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

37-754 FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Two Five Conductor + Ground (Two, Three & Four Conductor) 600 V Rated 90 C Conductor* Bare annealed copper conforming to ASTM B3 and Class B stranded in accordance with ASTM B8 *Also available in tinned copper Insulation Flame Retardant EP meeting the requirements of XHHW-2* *XLPE insulation available upon request RATINGS & APPROVALS Ground Bare or tinned copper provided on Two, Three & Four Conductor Cables Jacket A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoset CPE meeting UL 1277 n 90 C temperature rating n Conductors meet Type XHHW-2 per UL 44 n UL Listed as Type TC-ER (E123629) n Flame Retardant IEEE 1202/FT4 n Suitable for use in Class I, Div 2 and Zone 2 environments APPLICATION Type TC or TC-ER tray cable is permitted for use on power, lighting, control, and signal circuits; indoors or outdoors; in cable trays, raceways, direct burial in the ground or where supported in outdoor locations by a messenger wire; for Class 1 circuits as permitted in Article 725 of the NEC; and in cable trays in Class I, Division 2 hazardous locations in industrial establishments where the conditions of maintenance and supervision assure that only qualified persons will service the installation. Cables Marked TC-ER may also be used between a cable tray and the utilization equipment or device, when installed in accordance with NEC 336.10(7). FEATURES n Sunlight resistant. n For direct burial. n Insulated conductors are UL rated VW-1. n Insulation meets UL 1581, ICEA S-73-532 (NEMA WC57) and ICEA S-95-658 NEMA WC70 Type II n 130 C emergency overload rating n 90 C continuous rating in wet or dry locations n 250 C short circuit rating. n Resistant to moisture and most chemical atmospheres. n Thermal stability at elevated temperatures. n Flexible, easy to install and terminate. n Gas & vapor tight impervious to water and air n Grounding Conductor: Where indicated, bare or green insulated stranded copper per ASTM B-8 for sizes #8 AWG and smaller, compact round for sizes larger than #8 AWG per ASTM B-496 and in accordance with NEC Table 250.122. 1 www.nexansamercable.com e-mail: downstream@nexans.com

TWO CONDUCTOR + GROUND FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Size Weight DC Resist. AC Resist. Inductive Voltage Drop Uninsulated AWG/ Part No. Diameter (lbs./ @ 20 C @ 90 C, 60 Hz Reactance @ 90 C Grounding Cond. Ampacity kcmil 37-754 (Inches) MFt) (Ohms/1k ft) (Ohms/1k ft) (Ohms/1k ft) (Volts/Amp/1k ft) Size AWG 90 C 75 C 14-507G 0.415 106 2.62 3.339 0.037 4.660 14 25 20 12-515G 0.460 143 1.65 2.103 0.035 2.947 12 30 25 10-553G 0.490 185 1.04 1.325 0.033 1.868 10 40 35 8-209G 0.655 317 0.654 0.834 0.033 1.188 10 55 50 6-210G 0.745 448 0.411 0.524 0.031 0.758 8 75 65 4-594G 0.875 664 0.259 0.330 0.030 0.488 6 95 85 2-214G 1.005 968 0.163 0.208 0.028 0.317 6 130 115 1-215G 1.125 1203 0.129 0.164 0.029 0.257 6 148 131 1/0-216G 1.225 1479 0.102 0.130 0.028 0.209 6 170 150 2/0-217G 1.320 1799 0.0811 0.103 0.028 0.172 4 195 175 3/0-218G 1.425 2200 0.0643 0.082 0.027 0.141 4 224 199 4/0-219G 1.555 2709 0.0510 0.065 0.027 0.118 3 260 230 THREE CONDUCTOR + GROUND FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Size Weight DC Resist. AC Resist. Inductive Voltage Drop Uninsulated AWG/ Part No. Diameter (lbs./ @ 20 C @ 90 C, 60 Hz Reactance @ 90 C Grounding Cond. Ampacity kcmil 37-754 (Inches) MFt) (Ohms/1k ft) (Ohms/1k ft) (Ohms/1k ft) (Volts/Amp/1k ft) Size AWG 90 C 75 C 14-508G 0.415 106 2.62 3.339 0.037 4.660 14 25 20 12-516G 0.460 143 1.65 2.103 0.035 2.947 12 30 25 10-308G 0.490 185 1.04 1.325 0.033 1.868 10 40 35 8-309G 0.655 317 0.654 0.834 0.033 1.188 10 55 50 6-310G 0.745 448 0.411 0.524 0.031 0.758 8 75 65 4-312G 0.875 664 0.259 0.330 0.030 0.488 6 95 85 2-314G 1.005 968 0.163 0.208 0.028 0.317 6 130 115 1-315G 1.125 1203 0.129 0.164 0.029 0.257 6 148 131 1/0-316G 1.225 1479 0.102 0.130 0.028 0.209 6 170 150 2/0-317G 1.320 1799 0.0811 0.103 0.028 0.172 4 195 175 3/0-318G 1.425 2200 0.0643 0.082 0.027 0.141 4 224 199 4/0-319G 1.555 2709 0.0510 0.065 0.027 0.118 3 260 230 250-330G 1.740 3267 0.0432 0.055 0.027 0.104 3 290 255 350-331G 1.970 4423 0.0308 0.039 0.026 0.081 3 350 310 500-333G 2.340 6289 0.0216 0.028 0.026 0.066 2 430 380 750-334G 2.735 9146 0.0144 0.018 0.026 0.052 1 535 475 Manufactured by Nexans AmerCable 800-506-9473 713-896-5800 Fax: 713-849-9009 2

37-754 FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Two Five Conductor + Ground (Two, Three & Four Conductor) 600 V Rated 90 C FOUR CONDUCTOR + GROUND FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Size Weight DC Resist. AC Resist. Inductive Voltage Drop Uninsulated AWG/ Part No. Diameter (lbs./ @ 20 C @ 90 C, 60 Hz Reactance @ 90 C Grounding Cond. Ampacity kcmil 37-754 (Inches) MFt) (Ohms/1k ft) (Ohms/1k ft) (Ohms/1k ft) (Volts/Amp/1k ft) Size AWG 90 C 75 C 14-509G 0.450 129 2.620 3.339 0.040 4.663 14 20 16 12-517G 0.5 174 1.650 2.103 0.038 2.950 12 24 20 10-408G 0.570 247 1.040 1.325 0.035 1.871 10 32 28 8-409G 0.715 391 0.654 0.834 0.036 1.191 10 44 40 6-410G 0.815 558 0.411 0.524 0.034 0.760 8 60 52 4-412G 0.965 837 0.259 0.330 0.032 0.490 6 76 68 2-414G 1.110 1225 0.163 0.208 0.031 0.320 6 104 92 1-415G 1.245 1539 0.129 0.164 0.031 0.260 6 120 104 1/0-416G 1.350 1874 0.102 0.130 0.031 0.212 6 136 120 2/0-417G 1.46 2292 0.0811 0.103 0.030 0.174 4 156 140 3/0-418G 1.580 2812 0.0643 0.082 0.030 0.144 4 180 160 4/0-419G 1.785 3563 0.0510 0.065 0.029 0.120 3 208 184 250-430G 1.930 4177 0.0432 0.055 0.029 0.107 3 232 204 350-431G 2.185 5699 0.0308 0.039 0.029 0.084 3 280 248 500-433G 2.600 8178 0.0216 0.028 0.029 0.068 2 344 304 750-434G 3.105 12024 0.0144 0.018 0.028 0.055 1 428 380 FIVE CONDUCTOR FLAME RETARDANT EP/CPE TYPE TC OR TC-ER POWER CABLE Size Weight DC Resist. AC Resist. Inductive Voltage Drop AWG/ Part No. Diameter (lbs./ @ 20 C @ 90 C, 60 Hz Reactance @ 90 C Ampacity kcmil 37-754 (Inches) MFt) (Ohms/1k ft) (Ohms/1k ft) (Ohms/1k ft) (Volts/Amp/1k ft) 90 C 75 C 14-510 0.495 158 2.907 3.705 0.041 5.170 20 16 12-560 0.585 231 1.826 2.327 0.039 3.261 24 20 10-561 0.625 303 1.153 1.469 0.036 2.072 32 28 8-566 0.795 485 0.708 0.902 0.037 1.287 44 40 6-563 0.940 722 0.445 0.567 0.035 0.822 60 52 4-565 0.060 1032 0.300 0.382 0.033 0.564 76 68 2-566 1.230 1522 0.184 0.235 0.032 0.358 104 92 1-567 1.390 1901 0.147 0.187 0.032 0.293 120 104 1/0-568 1.505 2335 0.117 0.149 0.032 0.240 136 120 2/0-569 1.620 2853 0.093 0.119 0.031 0.197 156 140 4/0-746 1.970 4423 0.058 0.074 0.030 0.134 208 184 Ampacities are based on Table 310.15(B)(16) of the National Electrical Code (NEC) for conductors rated 90 C, in a multi-conductor cable, at an ambient temperature of 30 C. The 75 C column is provided for additional information. The ampacities shown apply to open runs of cable, installation in any approved raceway. Derating for more than three current carrying conductors within the cable is in accordance with NEC Table 310.15(B)(3)(a). The ampacities shown also apply to cables installed in cable tray in accordance with NEC Section 392.80. 3 www.nexansamercable.com e-mail: downstream@nexans.com

37-754 FLAME RETARDANT EP/CPE TYPE TC OR TC-ER INSTRUMENTATION CABLE Individually Shielded Pairs & Triads 600 V Rated 90 C Insulation Flame Retardant EP meeting the requirements of XHHW-2* *XLPE insulation available upon request RATINGS & APPROVALS n 90 C temperature rating n Conductors meet Type XHHW-2 per UL 44 n UL Listed as Type TC-ER (E123629) n Flame Retardant IEEE 1202/FT4 n Suitable for use in Class I, Div 2 and Zone 2 environments VALUES: 16 AWG Capacitance (nf/1000 feet) = 18 Inductance (mh/1000) = 0.22 Resistance (Ohms/1000 feet) = 2.62 (@ 20 C) 14 AWG Capacitance (nf/1000 feet) = 20 Inductance (mh/1000) = 0.21 Resistance (Ohms/1000 feet) = 4.19 (@ 20 C) Conductor* Bare annealed copper conforming to ASTM B3 and Class B stranded in accordance with ASTM B8 *Also available in tinned copper Pairs/ Triads Each pair/triad is twisted with a bare tinned drain wire. Each pair/triad is shielded with polyesterbacked aluminum foil tape to afford 100% coverage. Pair to pair, or triad to triad, isolation plus overall shielding is provided. Jacket A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoset CPE meeting UL 1277 APPLICATION Shielded instrumentation cables are designed for use on Class 1 Remote-Control Signaling circuits or where a 600V cable is desired, as instrumentation, process control, or computer cable transmitting signals at levels above 100 millivolts in circuits. They are designed for use indoors or outdoors; wet or dry locations; in cable trays; in raceways; supported by a messenger wire; for direct burial; in Class I, Division 2, Class II, Division 2 hazardous locations in industrial establishments where the conditions of maintenance and supervision assure that only qualified persons will service the installation. Cables Marked TC-ER may also be used between a cable tray and the utilization equipment or device, when installed in accordance with NEC 336.10(7). FEATURES n Sunlight resistant. n For direct burial (14 AWG). n Insulated conductors are UL rated VW-1. n Insulation meets UL 1581, ICEA S-73-532 (NEMA WC57) and ICEA S-95-658 NEMA WC70 Type II n 90 C continuous rating in wet or dry locations n 130 C emergency overload rating n 250 C short circuit rating. n Resistant to moisture and most chemical atmospheres. n Thermal stability at elevated temperatures. n Flexible, easy to install and terminate. n Gas & vapor tight impervious to water and air Size Part No. Diameter Weight AWG 37-754 Pairs Triads (Inches) (lbs/mft) 16-610 1 0.437 106 16-611 2 0.700 279 16-613 4 0.790 340 16-616 8 1.075 702 16-618 12 1.275 1062 16-699 24 0.164 1560 14-620 1 0.397 85 14-621 2 0.655 234 14-623 4 0.730 341 14-630 8 0.960 600 14-628 12 1.195 874 16-668 1 0.467 128 16-698 4 0.930 453 16-677 8 1.130 825 16-734 12 1.380 1235 Manufactured by Nexans AmerCable 800-506-9473 713-896-5800 Fax: 713-849-9009 4

37-754 FLAME RETARDANT EP/CPE TYPE TC OR TC-ER CONTROL CABLE Multi-Conductor 600 V Rated 90 C Insulation Flame Retardant EP meeting the requirements of XHHW-2* *XLPE insulation available upon request RATINGS & APPROVALS Conductor* Bare annealed copper conforming to ASTM B3 and Class B stranded in accordance with ASTM B8 *Also available in tinned copper Jacket A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoset CPE meeting UL 1277 APPLICATION Type TC or TC-ER tray cable is permitted for use on power, lighting, control, and signal circuits; indoors or outdoors; in cable trays, raceways, direct burial in the ground or where supported in outdoor locations by a messenger wire; for Class 1 circuits as permitted in Article 725 of the NEC; and in cable trays in Class I, Division 2 hazardous locations in industrial establishments where the conditions of maintenance and supervision assure that only qualified persons will service the installation. Cables Marked TC-ER may also be used between a cable tray and the utilization equipment or device, when installed in accordance with NEC 336.10(7). FEATURES n Sunlight resistant. n For direct burial (14 AWG and larger). n Insulated conductors are UL rated VW-1. n Insulation meets UL 1581, ICEA S-73-532 (NEMA WC57) and ICEA S-95-658 NEMA WC70 Type II n 90 C continuous rating in wet or dry locations n 130 C emergency overload rating n 250 C short circuit rating. n Resistant to moisture and most chemical atmospheres. n Thermal stability at elevated temperatures. n Flexible, easy to install and terminate. n Gas & vapor tight impervious to water and air n 90 C temperature rating n Conductors meet Type XHHW-2 per UL 44 n UL Listed as Type TC-ER (E123629) n Flame Retardant IEEE 1202/FT4 n Suitable for use in Class I, Div 2 and Zone 2 environments 5 www.nexansamercable.com e-mail: downstream@nexans.com

FLAME RETARDANT EP/CPE TYPE TC OR TC-ER CONTROL CABLE Weight Size Part No Number of Diameter (lbs./ Ampacity AWG 37-754 Conductors (Inches) MFt) 90 C 75 C 16-529 4 0.433 97 14 16-559 5 0.469 117 14 16-505 7 0.515 147 12 16-503 8 0.581 202 12 16-504 10 0.635 251 9 16-546 16 0.720 333 9 16-687 20 0.786 382 9 16-525 24 0.900 549 8 16-526 37 1.048 731 7 16-577 44 1.175 947 6 16-527 60 1.262 1117 6 16-581 91 1.550 1612 6 14-509 4 0.450 129 20 16 14-510 5 0.495 158 20 16 14-511 6 0.580 205 20 16 14-521 7 0.575 217 17 14 14-512 10 0.720 304 12 10 14-585 12 0.740 347 12 10 14-523 14 0.780 393 12 10 14-513 20 0.960 589 12 10 14-571 24 1.075 710 11 9 14-573 30 1.115 808 11 9 14-514 37 1.200 964 10 8 14-574 44 1.345 1299 8 7 14-582 91 1.840 2254 8 7 12-517 4 0.500 174 24 20 12-560 5 0.585 231 24 20 12-547 6 0.645 275 24 20 12-518 10 0.800 412 15 12 12-519 20 1.065 792 15 12 12-572 24 1.200 973 13 11 12-520 37 1.340 1333 12 10 Ampacities are based on Table 310.15(B)(16) of the National Electrical Code (NEC) for conductors rated 90 C, in a multi-conductor cable, at an ambient temperature of 30 C. The 75 C column is provided for additional information. The ampacities shown apply to open runs of cable, installation in any approved raceway. Derating for more than three current carrying conductors within the cable is in accordance with NEC Table 310.15(B)(3)(a). The ampacities shown also apply to cables installed in cable tray in accordance with NEC Section 392.80. Equipment Grounding Conductor: Any conductor in these cables may be permanently re-identified during installation as the equipment grounding conductor in accordance with Section 250.119(B) of the NEC. Manufactured by Nexans AmerCable 800-506-9473 713-896-5800 Fax: 713-849-9009 6

37-118 EPR/CPE TYPE RHH OR RHW-2 600 OR 2000 VOLTS POWER & CONTROL 90 C Limited Smoke (Sizes 2/0 and higher) EP/CPE Conductor* Bare, annealed copper conforming to ASTM B3 and Class B stranded, in accordance with ASTM B8 *Also available in tinned copper Jacket Flame retardant, oil and sunlight resistant Chlorinated Polyethylene (CPE) See below for jacket color options (Special order) RATINGS & APPROVALS SAVE TIME SAVE MONEY Separator Suitable separator tape provides easy stripping of insulation Insulation Ethylene-Propylene rubber (EPR) n ICEA S-95-658/NEMA WC-70: Nonshielded Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy n UL Standard 44: Thermoset Insulated Wires & Cables, Types RHH, RHW-2. UL VW-1 n UL Standard 1685: Vertical Tray Fire propagation and Smoke Release Test for Electrical and optical Fiber Cables. (UL,ST-1) n MSHA P-184 n RoHS Compliant Order Your RHH or RHW-2 Cable with Factory Installed Connectors APPLICATION Type RHH or RHW-2 Power and Control Cables are recommended for general power and control applications. These cables may be used in generating plants, substations and industrial plants. Type RHH or RHW-2 may be used up to 90 C in dry or wet locations. These cables may be installed in wet or dry locations, indoors or outdoors, in raceways, underground ducts, cable tray (size 1/0 AWG and larger per NEC 392) or lashed to a messenger for aerial installation. FEATURES n A two layer composite of flame retardant, oil and sunlight resistant Chlorinated Polyethylene (CPE) outer layer and Ethylene-Propylene rubber (EPR) inner layer. The composite design provides significant diameter reductions compared to designs using full thickness jackets. n Suitable for continuous operating temperatures of 90 C, wet or dry n Sizes 1/0 AWG and larger listed and marked for CT use n UL listed as Sunlight Resistant n Insulation and jacket meet hazardous waste regulations, per Code of Federal Regulations 40 Section 261 (40CFR261) for characteristic lead content n Flame Resistance: FT-4/IEEE1202 for sizes 1/0 AWG and larger; UL VW-1 n Meets smoke release and other requirements of Vertical Cable Tray Test UL 1685 and is marked ST-1 for 2/0 AWG 750 kcmil 7 www.nexansamercable.com e-mail: downstream@nexans.com

37-118 TYPE RHH OR RHW-2 600 VOLTS POWER AND CONTROL Part No. 37-118- Size AWG/ kcmil Minimum Wires per Conductor Insulation Thickness in. Jacket Thickness in. Outside Diameter in. Approx. Weight lbs. per *Ampacity 1,000 ft. 90 C 75 C -101 14 7 0.030 0.015 0.183 26 35 30-102 12 7 0.030 0.015 0.201 36 40 35-103 10 7 0.030 0.015 0.231 51 55 50-104 8 7 0.045 0.030 0.316 88 80 70-105 6 7 0.045 0.030 0.353 124 105 95-107 4 7 0.045 0.030 0.400 181 140 125-109 2 7 0.045 0.030 0.458 266 190 170-110 1 19 0.055 0.045 0.547 349 220 195-111 1/0 19 0.055 0.045 0.586 425 260 230-112 2/0 19 0.055 0.045 0.631 521 300 265-113 3/0 19 0.055 0.045 0.681 640 350 310-114 4/0 19 0.055 0.045 0.737 788 405 360-124 250 37 0.065 0.065 0.845 956 455 405-125 350 37 0.065 0.065 0.946 1299 570 505-126 500 37 0.065 0.065 1.074 1667 700 620-127 750 61 0.075 0.065 1.285 2672 885 785 37-118 TYPE RHH OR RHW-2 2000 VOLTS POWER AND CONTROL Part No. 37-118- Size AWG/ kcmil Minimum Wires per Conductor Insulation Thickness in. Jacket Thickness in. Outside Diameter in. Approx. Weight lbs. per *Ampacity 1,000 ft. 90 C 75 C -201 14 7 0.045 0.015 0.213 31 35 30-202 12 7 0.045 0.015 0.232 41 40 35-203 10 7 0.045 0.015 0.261 58 55 50-204 8 7 0.055 0.030 0.336 94 80 70-205 6 7 0.055 0.030 0.373 131 105 95-207 4 7 0.055 0.030 0.42 188 140 125-209 2 7 0.055 0.030 0.478 275 190 170-210 1 19 0.065 0.045 0.567 359 220 195-211 1/0 19 0.065 0.045 0.606 435 260 230-212 2/0 19 0.065 0.045 0.651 532 300 265-213 3/0 19 0.065 0.045 0.701 652 350 310-214 4/0 19 0.065 0.045 0.757 802 405 360-224 250 37 0.075 0.065 0.866 972 455 405-225 350 37 0.075 0.065 0.966 1317 570 505-226 500 37 0.075 0.065 1.094 1819 700 620-227 750 61 0.090 0.065 1.309 2699 885 785 * Ampacity Calculated with at 90 C conductor temperature and 30 C ambient air, per 2014 NEC Table 310.15(B)(17) Manufactured by Nexans AmerCable 800-506-9473 713-896-5800 Fax: 713-849-9009 8

CONDUCTOR ID Method #1-E2 per ICEA S-73-532 Conductor Insulation Stripe Conductor Insulation Stripe 1st BLACK 19th ORANGE Blue 2nd RED 20th YELLOW Blue 3rd BLUE 21st BROWN Blue 4th ORANGE 22nd BLACK Orange 5th YELLOW 23rd RED Orange 6th BROWN 24th BLUE Orange 7th RED Black 25th YELLOW Orange 8th BLUE Black 26th BROWN Orange 9th ORANGE Black 27th BLACK Yellow 10th YELLOW Black 28th RED Yellow 11th BROWN Black 29th BLUE Yellow 12th BLACK Red 30th ORANGE Yellow 13th BLUE Red 31st BROWN Yellow 14th ORANGE Red 32nd BLACK Brown 15th YELLOW Red 33rd RED Brown 16th BROWN Red 34th BLUE Brown 17th BLACK Blue 35th ORANGE Brown 18th RED Blue 36th YELLOW Brown Method 4 of ICEA S-73-532 Conductor Printing Details Conductor Printing Details 1st 1-ONE-1 5th 5-FIVE-5 2nd 2-TWO-2 6th 6-SIX-6 3rd 3-THREE-3 7th 7-SEVEN-7 4th 4-FOUR-4 8th 8-EIGHT-8 Manufactured by Nexans AmerCable 800-506-9473 713-896-5800 Fax: 713-849-9009 10

DOWNSTREAM OIL & GAS CABLES Nexans AmerCable is an ISO 9001 certified cable manufacturer that combines leading-edge manufacturing technology, innovative thinking, and high quality service to deliver the finest upstream oil & gas cable products available. Nexans AmerCable serves the world from our Oil & Gas Group headquarters in Houston, Texas. Our professional field engineers and sales force work with you to create innovative, cost effective project solutions. Industrial VFD Foil shielded, power cables engineered for use in variable frequency AC drive applications. Available in several constructions Industrial CIR Crush and Impact Resistant cables without external armoring CORFLEX Type MC-HL Cables Nexans Tray Cables Cables for wet or dry locations in cable trays, raceways, open air or direct burial Nexans Instrumentation Cables 300V & 600V Pairs and Triads CLICK HERE TO FOLLOW US! Nexans AmerCable 10633 West Little York Road - Building 1 - Suite 150 800-506-9473 713-896-5800 Fax: 713-849-9009 email: downstream@nexans.com www.nexansamercable.com 2018, AmerCable Incorporated 1_18