Similar documents
WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

UTICA BOILER. SSV Submittal. Project Name: Project Location: Contractor:

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Engineer: Project Name: Project Location: Contractor:

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

MERIT SERIES Downflow

Engineer: Project Name: Project Location: Contractor:

ELITE SERIES Downflow - High Efficiency Blower Motor

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

MERIT SERIES Downflow

Utica Boilers MAC Submittal

8+* Bulletin No November 1997

Date: Project #: Engineer: Prepared By: Bid Date:

13 GEP A L P - 1 A

Suggested Specifications Prestige Excellence 110

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

RGE 13 A T - 1 A

MERIT SERIES Upflow / Horizontal

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

USER'S INFORMATION MANUAL

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

USER'S INFORMATION MANUAL

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION

INSTALLATION INSTRUCTIONS

MERIT SERIES Downflow

USER'S INFORMATION MANUAL

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

Gas Valve. Combustion Air Intake. Supply Air Blower AM30. Typical Applications

INSTALLATION INSTRUCTIONS

USER'S INFORMATION MANUAL

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

DIVISION FINNED WATER-TUBE BOILERS

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION

DIVISION FINNED WATER-TUBE BOILERS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

G34M Bulletin #69/ August 2003

GSR21Q PULSE21 SERIES

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

DIVISION FINNED WATER-TUBE WATER HEATERS

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

Product Data BW9 WATER BOILER SERIES B

USER'S INFORMATION MANUAL

Raypak Residential Products

DIVISION FINNED WATER-TUBE BOILERS

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Revitalize Building Mechanical Systems (4619)

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

TABLE OF CONTENTS BRADFORD WHITE BOILERS

GB Condensing Gas Boiler

Project Name: Location: Engineer: Contractor: I. GENERAL

Models CHB/CCB APPLICATION GUIDE WALL MOUNTED GAS BOILER

Models UBSSC-050 UBSSC-075 UBSSC-100 UBSSC-150 UBSSC-200 UBSSC-299 WALL MOUNTED GAS BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL

WATER-TUBE POOL HEATERS

WALL MOUNTED GAS BOILER. INSTALLATION, OPERATION & MAINTENANCE MANUAL Models SSV-050 SSV-075 SSV-100 SSV-150 SSV-200

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER HIGH EFFICIENCY CONDENSING BOILER

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

U n i t H e at e r s

WATER-TUBE POOL HEATERS

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

DIVISION FINNED WATER-TUBE BOILERS

FINNED WATER-TUBE POOL HEATERS

Tankless Water Heaters

MERIT Series R-410A - Upflow / Horizontal

Trade Price Book - 816

C1210ES Tankless Water Heater

MERIT Series R-410A - Upflow / Horizontal

FINNED WATER-TUBE POOL HEATERS

NCB-E Combi-boilers. The first high efficiency condensing combi boilers that can do it all... for larger homes

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

LGB Gas fired boiler

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

Transcription:

PRODUCT SPECIFICATIONS WATER HEATERS / BOILERS GWM-IE Gas-Fired, Modulating, Condensing, Wall Hung Hot Water Boiler Bulletin No. 210650 March 2018 Supersedes December 2015 AFUE 95% Heating Input 50,000 to 200,000 Btuh MODEL NUMBER IDENTIFICATION GWM - 075 I E Series GWM = Gas-Wall-Mounted Boiler Ignition E = Electronic Ignition Capacity (Input) 050 = 50,000 Btuh 075 = 75,000 Btuh 100 = 100,000 Btuh 150 = 150,000 Btuh 200 = 200,000 Btuh I = Induced Draft Blower FEATURES CONTENTS Circulating Pump Flow Rate... 9 Dimensions... 7 Features... 1 Installation Clearances... 6 Intake/Exhaust Pipe Vent Lengths... 6 Model Number Identification... 1 Optional Accessories... 6 Optional Accessory Dimensions... 8 Specifications... 6 WARRANTY Heat Exchanger - Limited fifteen year warranty in residential applications. All other covered components - Limited ten year warranty in residential applications and one year in nonresidential applications. Refer to Lennox Equipment Limited Warranty certificate included with equipment for details.

FEATURES D C I H B B HEATING SYSTEM Stainless Steel Helical Heat Exchanger Assembly Stainless steel (316L/444) fin and tube heat exchanger features a wide diameter stainless steel tube with laser welded heat transfer fins. Helical design and inner finned tubing results in overall compact boiler with superior heat transfer characteristics. Self-cleaning design helps to remove hard water desposits and prevent scaling. Sight glass on top of heat exchanger permits easy viewing of the burner flame. F APPROVALS Low pressure, stainless steel boilers are design certified by CSA for use with natural gas or LPG/Propane. Annual Fuel Utilization Efficiencies are based on US DOE test procedures and FTC labeling regulations. Units are certified by AHRI. Boiler heat exchanger assemblies are constructed and hydrostatically tested in accordance with American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Section IV Standards for stainless steel heating boilers. Energy Star certified units are designed to use less energy, help save money on utility bills, and help protect the environment. APPLICATIONS Five models with heating inputs of 50,000 to 200,000 Btuh. AFUE - 95%. G Direct spark ignition. E Natural gas or LPG/propane. LPG kit is furnished with unit. Boiler applications include radiant floor heating, baseboard heating, radiators and zoned heating systems. Compact units allow easy mounting on a wall in a closet, alcove, basement or utility room. All units are completely factory assembled with all controls installed and wired. Each unit is factory test operated to ensure dependable performance. GWM-IE / Page 2 C D E F Stainless Steel Mesh Modulating Burner Provides efficient, trouble-free operation. Mixes air and gas in correct proportion for proper combustion. Direct Spark Igniter Electronic spark igniter provides positive ignition on each operating cycle. Automatic Gas Control Silent operating gas controls provide 100% safety shut-off. 115 volt redundant combination gas control valve combines manual shut off option (On-Off), automatic electric valve (dual) and gas pressure regulation into a compact combination control. Dual valve design provides double assurance of 100% close off of gas to the main burners on each off cycle. Should a loss of flame occur, the main valve closes, shutting down the unit. Gas shutoff valve is furnished in gas supply line to gas valve. Combustion Air Blower Heavy duty blower safely vents flue products. Motor is permanently lubricated and has ball bearings. Loss of flame signal prevents unit operation in case of flue blockage of flue outlet. Polypropylene Flue Condensate Collector Corrosion resistant polypropylene flue condensate collector collects flue condensate for disposal through condensate drain on bottom of unit. Condensate drain trap is included with the unit. Circulating Pump Heavy duty pump is constructed of cast iron. Pump motor is impedance protected. Motor and impeller is removable as a single unit for servicing.

FEATURES HEATING SYSTEM (continued) Relief Valve and Air Vent Furnished as standard for field installation in top of cabinet. Valve provides for pressure relief of heating system in case of abnormal operating conditions. Valve opens at 30 psig and is approved by ASME. Combination Temperature/Pressure Gauge Furnished for field installation in supply water line at bottom of unit cabinet. Monitors system for safe and reliable operation. Brass Drain Valve 3/4 in. brass drain valve is furnished for field installation in return water line at bottom of unit cabinet. LPG/Propane Conversion Kit (Furnished) Conversion kit is required for field changeover from natural gas. DIRECT VENT SEALED COMBUSTION SYSTEM Boiler features a sealed combustion system that can be installed in Direct Vent (single or two pipe) applications. In Direct Vent applications, combustion air is supplied from outdoors and flue gases are discharged outdoors. G H INTEGRATED PRIMARY/SECONDARY PIPING WITH PUMP Primary and secondary piping with circulator pump are factory installed and piped internal to the unit. Reduces installation costs. CABINET Constructed of heavy gauge steel with a baked-on enamel paint finish. Front cover slides on and off for easy servicing. Combustion air and vent connections are located on the top of the cabinet. Condensate drain connection is furnished on bottom of cabinet. Water supply and return connections are furnished on bottom of cabinet. Knockouts are provided in bottom of cabinet for line and low voltage connections. Wall Hanging Support Bracket Furnished with boiler to facilitate hanging boiler on a wall. Flange on back of boiler cabinet engages support bracket installed on wall for easy mounting. VENTING Vent Temperature Sensor Loss of flame signal prevents unit operation in case of flue blockage. Vent temperature sensor is furnished as standard and factory installed on the polypropylene flue condensate collector. Optional Accessories Termination Kit - Concentric 2 or 3 inch kit contains concentric termination assembly, reducer bushing and 45 elbow. Kit requires single hole penetration of roof or wall for installation. Roof penetration applications requires field supplied boot/flashing. CSA certified. GWM-IE / Page 3

FEATURES I CONTROL MODULE/USER INTERFACE Boiler is equipped with programmable Electronic Control Module and User Interface Control. Fully Modulating Electronic Control Automatically adjusts heat input in increments from to 20% to 100% (full input) for greater water temperature control. User Interface Control Buttons (MENU, ENTER, RESET and UP/DOWN ARROWS) allow access to the Boiler Status Screens. RESET - Manual Lockout Boiler Reset. MENU - Enter/Exit user menu, Go to the previous screen. ENTER - Select a menu item, Confirm a new parameter value. UP/DOWN ARROWS - Scroll up/down to next menu item. Increase/decrease value. LCD Display Displays information about the boiler operation and service reminders. BLOCKING ERROR - Error code and short text description displayed. Boiler automatically returns to Standby Mode when the condition corrected. BOILER STATUS Current Water Supply Setpoint and CH or DHW Supply Water Setpoint Supply (leaving) and Return (entering) Water Temperatures DHW Thermostat Open or Closed System Water Temperature (if used) Vent System Temperature Outdoor Temperature (if used) Heat Exchanger Pump Status (On or Off) CH or DHW Pump Status (On or Off) USER MENU Settings Central Heating Setpoint (104 to 195 F, default is 140 F) DHW (Domestic Hot Water) Setpoint (104 to 195 F, default is 180 F) Temperature Units ( F or C, default is F) Bold indicates default setting. SCREENS Boiler Status Indicator F = Flame Detected P = Central Heating (CH) System Pump On B = Combustion Air Blower On S = Safety Relay Check G = Gas Valve Open D = Direct Hot Water (DHW) Pump On PERCENT (%) - Combustion Air Blower Speed Indicator SERVICE REMINDER - Service Reminder Indicator STANDBY: NO DEMAND - Boiler in Standby Mode F or C - Boiler Supply Water Temperature Indicator CENTRAL HEATING - Boiler Running in Central Heating Mode DOMESTIC HOT WATER - Boiler Running in Direct Hot Water (DHW) Mode. LOCKOUT ALARM - Error code and short text description displayed. Press RESET key for manual reset. GWM-IE / Page 4

FEATURES CONTROL MODULE/USER INTERFACE INSTALLER MENU (CONTINUED) Boiler Configuration Boiler Address (0 to 15, default is 0) Low Water Cutoff (Enabled/Disabled, default is Enabled) Pump Mode (0 and 4, default is 0) Service Reminder Status (ON/OFF, default is ON) Service Reminder Days (1-999 Days, default is 365 Days) CH (Central Heating) Settings CH Mode (0, 1, 2, 3, default is 1) Warm Weather Shutdown (35 to 100 F, default is 70 F) Reset Curve Design Temperature - Boiler (60 to 195 F, default is 180 F) Reset Curve Design Temperature - Outdoor (-60 to 32 F, default is 25 F) Reset Curve Mild Weather Temperature - Boiler (35 to 120 F, default is 100 F) Reset Curve Mild Weather Temperature - Outdoor (35 to 85 F, default is 70 F) Reset Curve Boiler Minimum Temperature (40 to 180 F, default is 70 F) Reset Curve Boiler Maximum Temperature (80 to 195 F, default is 180 F) Boost Function Temperature (0 to 36 F, default is 0 F) Boost Function Time (1 to 120 minutes, default is 20 minutes) Maximum Power CH (1 to 100%, default is 100%) DHW (Direct Hot Water) Settings DHW Mode (0/2, default is 0) DHW Maximum Priority Time (1 to 60 minutes, default is 30 minutes) Refer to Installation Instructions for more detailed information. Bold indicates default setting. ADDITIONAL CONTROLS Flame Sensor Flame sensitive sensor is furnished and factory installed on the heat exchanger. Prevents unit operation in the event there is a loss of flame or unstable flame. Integrated Low Water Cutoff Control Interrupts power immediately in a low water condition. Automatically restarts burner on return of water level. Factory installed and wired. Low water indicator LED. Test button. Transformer Supplies 24V power to Low Water Cutoff Control. Supply Water Switch Monitors boiler water temperature in conjunction with the main boiler control to adjust the heat output of the boiler to meet system demands. Shuts off boiler in case of abnormal supply water temperature. Return Water Temperature Sensor Monitors return water temperature. Terminal Block Removable for easy wiring connections. High Voltage Junction Box For line voltage connections. Located inside bottom of cabinet Optional Accessories High Altitude Control Module Required at altitudes from 2000-4500 ft. Module replaces existing control model in unit. Thermostat See Thermostat bulletins in Controls section and Lennox Price Book for a complete list of thermostats. GWM-IE / Page 5

SPECIFICATIONS Model No. GWM-050IE GWM-075IE GWM-100IE GWM-150IE GWM-200IE Gas Heating Performance Heating capacity input Btuh (Maximum) 50,000 75,000 100,000 150,000 200,000 Btuh (Minimum) 10,000 15,000 20,000 30,000 40,000 Heating capacity output - Btuh 46,000 69,000 91,000 139,000 185,000 1 Net AHRI I=B=R rating - Btuh 40 50 79 121 161 2 AFUE 95% 95% 95% 95% 95% Connections in. Flue size diameter (round) 2 2 2 3 3 Gas piping size 1/2 NPT 1/2 NPT 1/2 NPT 3/4 NPT 3/4 NPT Water supply and return size 1-1/4 NPT 1-1/4 NPT 1-1/4 NPT 1-1/4 NPT 1-1/4 NPT Drain connection size 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Electrical characteristics 120 volts - 60 hertz - 1 phase (less than 12 amps) Shipping Data lbs. - 1 package 111 111 111 182 182 OPTIONAL ACCESSORIES Concentric Vent Kit US - 2 inch 69M29 69M29 69M29 - - - - - - 3 inch - - - 60L46 60L46 60L46 60L46 Canada - 2 inch 44W92 44W92 44W92 - - - - - - 3 inch - - - 44W93 44W93 44W93 44W93 High Altitude Control Module (2000-4500 ft.) 12Y86 12Y86 12Y86 12Y86 12Y86 1 AHRI I=B=R ratings indicate the amount of equivalent direct radiation each boiler will produce under normal conditions and thermostatic control. Ratings based on an allowance of 1.15 in accordance with the factors shown on the I=B=R Standard as published by The Hydronics Institute. Selection of boiler size should be based on Net I=B=R Rating being equal to or greater than the calculated heat loss of the building. 2 Heating Capacity and AFUE (Annual Fuel Utilization Efficiency) based on US DOE test procedures and FTC labeling regulations. NOTE - Termination Kits 44W92, 44W93 are certified to ULC S636 standard for use in Canada only. INTAKE/EXHAUST PIPE VENT LENGTHS Model No. Pipe Size Minimum Maximum INSTALLATION CLEARANCES in. mm GWM-050IE 2 inch 6 ft 100 ft. Top 0 0 GWM-075IE GWM-100IE 2 inch 6 ft. 50 ft. 3 inch 6 ft. 100 ft. Top Service 14 356 Left Side 0 0 GWM-150IE GWM-200IE NOTES: One 90 elbow = 5 ft. One 45 elbow = 3.5 ft. One 2 x 3 in. adaptor = 0 ft. Concentric Vent Kit (optional) = 5 ft. 3 inch 6 ft. 100 ft. Right Side 0 0 Front 0 0 Front (Service) 6 152 Back 0 0 Bottom 0 0 Bottom (Service) 12 305 Combustion Air/Vent Piping 0 0 Combustion Air/Vent Piping (Service) 6 152 Hot Water Piping 1/2 13 Hot Water Piping (Service) 6 152 NOTE - Air for combustion must conform to the methods outlined in the National Fuel Gas Code (NFPA 54/ANSI-Z223.1) or the National Standard of Canada CAN/CSA-B149.1 Natural Gas and Propane Installation Code. NOTE - In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA 54/ANSI-Z223.1) or applicable provisions of local building codes. In Canada flue sizing must conform to the methods outlined in National Standard of Canada CAN/CSA-B149.1. GWM-IE / Page 6

DIMENSIONS - INCHES (MM) Vent Connector Safety Relief Valve Connection Combustion Air Wall Hanging Bracket TOP VIEW A D B BACK VIEW FRONT VIEW Condensate Drain Connection SIDE VIEW Gas Connection Supply Water 2 (51) 4-1/2 (114) C Return Water BOTTOM VIEW Model No. GWM-050IE GWM-075IE GWM-100IE GWM-150IE GWM-200IE A B C D in. mm in. mm in. mm in. mm 20 508 31 787 14 356 28 711 23 584 42 1092 16 406 40 1016 GWM-IE / Page 7

OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) 69M29 / 44W92 2 inch kits 60L46 / 44W93 3 inch kits See Installation Instructions for additional information. Note - Field provided reducer may be required to adapt larger vent pipe size to termination. Cat. No. A B in. mm in. mm ELBOW (Field Supplied) A 3 1/2 (89) 2 in. kits 4 1/2 (114) 3 in. kits TERMINATION ASSEMBLY (Furnished) 6 1/2 (165) INTAKE AIR 6 (152) EXHAUST AIR Outdoor Exhaust Accelerator included with 44W92 69M29 33 3/8 848 16 3/4 425 44W92 (Canada) 29 737 15 1/2 394 60L46 38 7/8 987 21 3/16 538 44W93 (Canada) 36 1/8 918 19 1/2 495 NOTE Typical illustration for dimensions only. Design may vary depending on kit ordered. CONCENTRIC WALL TERMINATION APPLICATIONS CONCENTRIC ROOF TERMINATION APPLICATIONS EXHAUST AIR OUTSIDE WALL INTAKE AIR EXHAUST AIR 12 (305) Minimum Above Average Snow Accumulation FLASHING (Not Furnished) INTAKE AIR CLAMP (Not Furnished) INTAKE AIR 12 (305) Minimum Above Grade or Average Snow Accumulation CLAMP SHEET METAL STRAP (Clamp and sheet metal strap must be field installed to support the weight of the termination kit.) GRADE GWM-IE / Page 8

CIRCULATING PUMP FLOW RATE TOTAL HEAD-FEET 0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 5.1 5.4 16 4.8 1 003B 2 14 005 4.2 3 006 4 006B 12 * 5 007 3.6 6 008 10 8 6 5 2 4 3 6 00 CIRCULATORS FLOW-M3/H 3.0 2.4 1.8 TOTAL HEAD-METERS 4 1 1.2 2 0.6 0 0.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 FLOW-GPM *007 Pump furnished with all boilers. GWM-IE / Page 9

REVISIONS Sections New Description of Change Added circulator pump flow rate chart. C US Visit us at www.lennox.com For the latest technical information, www.lennoxpros.com Contact us at 1-800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 2018 Lennox Industries, Inc.