THE UK'S ONLY NOx CLASS 6 RATED FLOOR STANDING BOILER IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING The Imax Xtra EL range of dual condensing boilers is available in 5 models with outputs from 715 to 1240kW. Suitable for floor standing applications. FEATURES AND BENEFITS Simple control interface with large backlit display Volt free contacts 0-10v BMS operation standard Robust aluminium silicon alloy heat exchanger Up to 109.8% part load efficiency 2 year parts and labour warranty NOx <40mg/kWh Natural Gas Optional extras include: Flow & return headers 5 connection Gas header 3 connection Dual air inlet DIMENSIONS AND CLEARANCES DIM A DIM B DIM C 1674 1567 1685 The following minimum clearances must be maintained for operation and servicing: TOP R SIDE B L SIDE REAR 1000mm FRONT A C For full details of all configurations & specifications, please refer to the Imax Xtra EL installation manual. All dimensions in mm IDEAL COMMERCIAL BOILERS PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN F: 0844 5436181 IDEALCOMMERCIALBOILERS.COM
IMAX XTRA EL 715kW TECHNICAL SPECIFICATIONS. GENERAL Dry Weight kg 918 Boiler Dimensions mm 1567 (H) x 1674 (W) x 1685 (D) Boiler Clearances mm Front: 700 Left Side: 700 Right Side: 700 Top: 700 Rear: 1000 Seasonal Efficiency (Building Regs L2) Gross % 96.8 Min/Max Gas pressure (Nat Gas) mbar 15-20 BURNER PRE MIX Fuel (Type G20) Natural Gas Fuel Consumption (Nat Gas) m³/h 72 Flame Protection Ionisation Ignition Spark Boiler Output (Mean 70 C) kw 131.5-666.7 Boiler Output (Mean 40 C) kw 147.2-722.6 Boiler Input (Gross cv) kw 755.8 Gas Inlet Size 2 x G2 NOx Rating/emissions at 0% O mg/kwh Class 6 (<40) HYDRAULICS Hydraulic Resistance (11 C T) mbar 25 Hydraulic Resistance (20 C T) mbar 102.9 Nominal Flow Rate (11 C T) l/s 15.5 Nominal Flow Rate (20 C T) l/s 8.5 Min Flow Rate (20 C T) (MAX MOD) l/s 1.7 Min Flow Temperature C 30 Max Flow Temperature C 90 Min Working Pressure bar 1 Max Working Pressure bar 6 Max Static Head Of Water metres 61 Condensate Connection mm 21.5 x 2 High Limit Set Point C 100 flow, 100 return 105 H/Ex Flow & Return Size 2 x G3 Water Content litres 94.6 FLUE/AIR INLET Flue Size mm 300 Flue Gas Volume m³/h 1055.9 Min-Max Flue Gas Temperature 80/60 C 50-63 Max Flue Resistance Pa 100 ELECTRICAL Electrical Supply 230/240V 50Hz 1 Ph Current (Max No Pump) Amp 2 x 2.65 Power Consumption Watt 1202 Modulating Input V/dc 0-10V Fuse Rating Amp 2 x 7 Controls Voltage V 24 or 240 Insulation Class IP IP20 CONTROL OPERATION On/Off 0-10V DC OpenTherm High Limit Protection Low Water Protection Volt Free Common Alarm Boiler Run Indication OPTIONAL EXTRAS Modulating Sequencer Kit, including DHW Tank Kit, Plant Room Sensor Kit, 6 Zone Expansion Kit Programmable Room Thermostat Kits Outside Sensor Kit DHW Tank Sensor Kit Safety Interlock Kit BACNet Gateway Kit LONWorks Gateway Kit MODBus Gateway Kit Remote Access Kit Sealed System Services Flow Manifold Kit Inlet Air Filter Kit Condensate Pump Kit Room Sealed Air Duct Kit Header Kit (flow/return) Header Kit (gas) Header Kit (air) FLOOR STANDING NOx CLASS 6 BIM *2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation. GET A QUOTE. W: IDEALCOMMERCIALBOILERS.COM Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification. 211221
THE UK'S ONLY NOx CLASS 6 RATED FLOOR STANDING BOILER IMAX XTRA EL. 790kW FLOOR STANDING CONDENSING The Imax Xtra EL range of dual condensing boilers is available in 5 models with outputs from 715 to 1240kW. Suitable for floor standing applications. FEATURES AND BENEFITS Simple control interface with large backlit display Volt free contacts 0-10v BMS operation standard Robust aluminium silicon alloy heat exchanger Up to 109.8% part load efficiency 2 year parts and labour warranty NOx <40mg/kWh Natural Gas Optional extras include: Flow & return headers 5 connection Gas header 3 connection Dual air inlet DIMENSIONS AND CLEARANCES DIM A DIM B DIM C 1674 1567 1685 The following minimum clearances must be maintained for operation and servicing: TOP R SIDE B L SIDE REAR 1000mm FRONT A C For full details of all configurations & specifications, please refer to the Imax Xtra EL installation manual. All dimensions in mm IDEAL COMMERCIAL BOILERS PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN F: 0844 5436181 IDEALCOMMERCIALBOILERS.COM
IMAX XTRA EL 790kW TECHNICAL SPECIFICATIONS. GENERAL Dry Weight kg 952 Boiler Dimensions mm 1567 (H) x 1674 (W) x 1685 (D) Boiler Clearances mm Front: 700 Left Side: 700 Right Side: 700 Top: 700 Rear: 1000 Seasonal Efficiency (Building Regs L2) Gross % 96.8 Min/Max Gas pressure (Nat Gas) mbar 15-20 BURNER PRE MIX Fuel (Type G20) Natural Gas Fuel Consumption (Nat Gas) m³/h 72 Flame Protection Ionisation Ignition Spark Boiler Output (Mean 70 C) kw 145.2-736.6 Boiler Output (Mean 40 C) kw 161-799 Boiler Input (Gross cv) kw 835 Gas Inlet Size 2 x G2 NOx Rating/emissions at 0% O mg/kwh Class 6 (<40) HYDRAULICS Hydraulic Resistance (11 C T) mbar 25 Hydraulic Resistance (20 C T) mbar 100.8 Nominal Flow Rate (11 C T) l/s 17.2 Nominal Flow Rate (20 C T) l/s 9.4 Min Flow Rate (20 C T) (MAX MOD) l/s 1.88 Min Flow Temperature C 30 Max Flow Temperature C 90 Min Working Pressure bar 1 Max Working Pressure bar 6 Max Static Head Of Water metres 61 Condensate Connection mm 21.5 x 2 High Limit Set Point C 100 flow, 100 return 105 H/Ex Flow & Return Size 2 x G3 Water Content litres 106.6 FLUE/AIR INLET Flue Size mm 300 Flue Gas Volume m³/h 1166.6 Min-Max Flue Gas Temperature 80/60 C 50-63 Max Flue Resistance Pa 100 ELECTRICAL Electrical Supply 230/240V 50Hz 1 Ph Current (Max No Pump) Amp 2 x 2.57 Power Consumption Watt 1184 Modulating Input V/dc 0-10V Fuse Rating Amp 2 x 7 Controls Voltage V 24 or 240 Insulation Class IP IP20 CONTROL OPERATION On/Off 0-10V DC OpenTherm High Limit Protection Low Water Protection Volt Free Common Alarm Boiler Run Indication OPTIONAL EXTRAS Modulating Sequencer Kit, including DHW Tank Kit, Plant Room Sensor Kit, 6 Zone Expansion Kit Programmable Room Thermostat Kits Outside Sensor Kit DHW Tank Sensor Kit Safety Interlock Kit BACNet Gateway Kit LONWorks Gateway Kit MODBus Gateway Kit Remote Access Kit Sealed System Services Flow Manifold Kit Inlet Air Filter Kit Condensate Pump Kit Room Sealed Air Duct Kit Header Kit (flow/return) Header Kit (gas) Header Kit (air) FLOOR STANDING NOx CLASS 6 BIM *2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation. GET A QUOTE. W: IDEALCOMMERCIALBOILERS.COM Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification. 211222
THE UK'S ONLY NOx CLASS 6 RATED FLOOR STANDING BOILER IMAX XTRA EL. 940kW FLOOR STANDING CONDENSING The Imax Xtra EL range of dual condensing boilers is available in 5 models with outputs from 715 to 1240kW. Suitable for floor standing applications. FEATURES AND BENEFITS Simple control interface with large backlit display Volt free contacts 0-10v BMS operation standard Robust aluminium silicon alloy heat exchanger Up to 109.8% part load efficiency 2 year parts and labour warranty NOx <40mg/kWh Natural Gas Optional extras include: Flow & return headers 5 connection Gas header 3 connection Dual air inlet DIMENSIONS AND CLEARANCES DIM A DIM B DIM C 1674 1567 1685 The following minimum clearances must be maintained for operation and servicing: TOP R SIDE B L SIDE REAR 1000mm FRONT A C For full details of all configurations & specifications, please refer to the Imax Xtra EL installation manual. All dimensions in mm IDEAL COMMERCIAL BOILERS PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN F: 0844 5436181 IDEALCOMMERCIALBOILERS.COM
IMAX XTRA EL 940kW TECHNICAL SPECIFICATIONS. GENERAL Dry Weight kg 1008 Boiler Dimensions mm 1567 (H) x 1674 (W) x 1685 (D) Boiler Clearances mm Front: 700 Left Side: 700 Right Side: 700 Top: 700 Rear: 1000 Seasonal Efficiency (Building Regs L2) Gross % 96.9 Min/Max Gas pressure (Nat Gas) mbar 15-20 BURNER PRE MIX Fuel (Type G20) Natural Gas Fuel Consumption (Nat Gas) m³/h 94.8 Flame Protection Ionisation Ignition Spark Boiler Output (Mean 70 C) kw 170.4-877.2 Boiler Output (Mean 40 C) kw 191.2-951.6 Boiler Input (Gross cv) kw 993.6 Gas Inlet Size 2 x G2 NOx Rating/emissions at 0% O mg/kwh Class 6 (<40) HYDRAULICS Hydraulic Resistance (11 C T) mbar 24 Hydraulic Resistance (20 C T) mbar 98.7 Nominal Flow Rate (11 C T) l/s 20.4 Nominal Flow Rate (20 C T) l/s 11.2 Min Flow Rate (20 C T) (MAX MOD) l/s 2.24 Min Flow Temperature C 30 Max Flow Temperature C 90 Min Working Pressure bar 1 Max Working Pressure bar 6 Max Static Head Of Water metres 61 Condensate Connection mm 21.5 x 2 High Limit Set Point C 100 flow, 100 return 105 H/Ex Flow & Return Size 2 x G3 Water Content litres 118.6 FLUE/AIR INLET Flue Size mm 300 Flue Gas Volume m³/h 1388 Min-Max Flue Gas Temperature 80/60 C 50-63 Max Flue Resistance Pa 100 ELECTRICAL Electrical Supply 230/240V 50Hz 1 Ph Current (Max No Pump) Amp 2 x 2.91 Power Consumption Watt 1340 Modulating Input V/dc 0-10V Fuse Rating Amp 2 x 7 Controls Voltage V 24 or 240 Insulation Class IP IP20 CONTROL OPERATION On/Off 0-10V DC OpenTherm High Limit Protection Low Water Protection Volt Free Common Alarm Boiler Run Indication OPTIONAL EXTRAS Modulating Sequencer Kit, including DHW Tank Kit, Plant Room Sensor Kit, 6 Zone Expansion Kit Programmable Room Thermostat Kits Outside Sensor Kit DHW Tank Sensor Kit Safety Interlock Kit BACNet Gateway Kit LONWorks Gateway Kit MODBus Gateway Kit Remote Access Kit Sealed System Services Flow Manifold Kit Inlet Air Filter Kit Condensate Pump Kit Room Sealed Air Duct Kit Header Kit (flow/return) Header Kit (gas) Header Kit (air) FLOOR STANDING NOx CLASS 6 BIM *2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation. GET A QUOTE. W: IDEALCOMMERCIALBOILERS.COM Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification. 211223
THE UK'S ONLY NOx CLASS 6 RATED FLOOR STANDING BOILER IMAX XTRA EL. 1090kW FLOOR STANDING CONDENSING The Imax Xtra EL range of dual condensing boilers is available in 5 models with outputs from 715 to 1240kW. Suitable for floor standing applications. FEATURES AND BENEFITS Simple control interface with large backlit display Volt free contacts 0-10v BMS operation standard Robust aluminium silicon alloy heat exchanger Up to 109.8% part load efficiency 2 year parts and labour warranty NOx <40mg/kWh Natural Gas Optional extras include: Flow & return headers 5 connection Gas header 3 connection Dual air inlet DIMENSIONS AND CLEARANCES DIM A DIM B DIM C 1674 1567 1685 The following minimum clearances must be maintained for operation and servicing: TOP R SIDE B L SIDE REAR 1000mm FRONT A C For full details of all configurations & specifications, please refer to the Imax Xtra EL installation manual. All dimensions in mm IDEAL COMMERCIAL BOILERS PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN F: 0844 5436181 IDEALCOMMERCIALBOILERS.COM
IMAX XTRA EL 1090kW TECHNICAL SPECIFICATIONS. GENERAL Dry Weight kg 1066 Boiler Dimensions mm 1567 (H) x 1674 (W) x 1685 (D) Boiler Clearances mm Front: 700 Left Side: 700 Right Side: 700 Top: 700 Rear: 1000 Seasonal Efficiency (Building Regs L2) Gross % 96.9 Min/Max Gas pressure (Nat Gas) mbar 15-20 BURNER PRE MIX Fuel (Type G20) Natural Gas Fuel Consumption (Nat Gas) m³/h 109.8 Flame Protection Ionisation Ignition Spark Boiler Output (Mean 70 C) kw 201.4-1017.2 Boiler Output (Mean 40 C) kw 226-1105.4 Boiler Input (Gross cv) kw 1152 Gas Inlet Size 2 x G2 NOx Rating/emissions at 0% O mg/kwh Class 6 (<40) HYDRAULICS Hydraulic Resistance (11 C T) mbar 24 Hydraulic Resistance (20 C T) mbar 97.65 Nominal Flow Rate (11 C T) l/s 23.7 Nominal Flow Rate (20 C T) l/s 13 Min Flow Rate (20 C T) (MAX MOD) l/s 2.6 Min Flow Temperature C 30 Max Flow Temperature C 90 Min Working Pressure bar 1 Max Working Pressure bar 6 Max Static Head Of Water metres 61 Condensate Connection mm 21.5 x 2 High Limit Set Point C 100 flow, 100 return 105 H/Ex Flow & Return Size 2 x G3 Water Content litres 130.6 FLUE/AIR INLET Flue Size mm 350 Flue Gas Volume m³/h 1609.4 Min-Max Flue Gas Temperature 80/60 C 50-63 Max Flue Resistance Pa 100 ELECTRICAL Electrical Supply 230/240V 50Hz 1 Ph Current (Max No Pump) Amp 2 x 2.71 Power Consumption Watt 1250 Modulating Input V/dc 0-10V Fuse Rating Amp 2 x 7 Controls Voltage V 24 or 240 Insulation Class IP IP20 CONTROL OPERATION On/Off 0-10V DC OpenTherm High Limit Protection Low Water Protection Volt Free Common Alarm Boiler Run Indication OPTIONAL EXTRAS Modulating Sequencer Kit, including DHW Tank Kit, Plant Room Sensor Kit, 6 Zone Expansion Kit Programmable Room Thermostat Kits Outside Sensor Kit DHW Tank Sensor Kit Safety Interlock Kit BACNet Gateway Kit LONWorks Gateway Kit MODBus Gateway Kit Remote Access Kit Sealed System Services Flow Manifold Kit Inlet Air Filter Kit Condensate Pump Kit Room Sealed Air Duct Kit Header Kit (flow/return) Header Kit (gas) Header Kit (air) FLOOR STANDING NOx CLASS 6 BIM *2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation. GET A QUOTE. W: IDEALCOMMERCIALBOILERS.COM Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification. 211224
THE UK'S ONLY NOx CLASS 6 RATED FLOOR STANDING BOILER IMAX XTRA EL. 1240kW FLOOR STANDING CONDENSING The Imax Xtra EL range of dual condensing boilers is available in 5 models with outputs from 715 to 1240kW. Suitable for floor standing applications. FEATURES AND BENEFITS Simple control interface with large backlit display Volt free contacts 0-10v BMS operation standard Robust aluminium silicon alloy heat exchanger Up to 109.8% part load efficiency 2 year parts and labour warranty NOx <40mg/kWh Natural Gas Optional extras include: Flow & return headers 5 connection Gas header 3 connection Dual air inlet DIMENSIONS AND CLEARANCES DIM A DIM B DIM C 1674 1567 1685 The following minimum clearances must be maintained for operation and servicing: TOP R SIDE B L SIDE REAR 1000mm FRONT A C For full details of all configurations & specifications, please refer to the Imax Xtra EL installation manual. All dimensions in mm IDEAL COMMERCIAL BOILERS PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN F: 0844 5436181 IDEALCOMMERCIALBOILERS.COM
IMAX XTRA EL 1240kW TECHNICAL SPECIFICATIONS. GENERAL Dry Weight kg 1106 Boiler Dimensions mm 1567 (H) x 1674 (W) x 1685 (D) Boiler Clearances mm Front: 700 Left Side: 700 Right Side: 700 Top: 700 Rear: 1000 Seasonal Efficiency (Building Regs L2) Gross % 97 Min/Max Gas pressure (Nat Gas) mbar 15-20 BURNER PRE MIX Fuel (Type G20) Natural Gas Fuel Consumption (Nat Gas) m³/h 124.4 Flame Protection Ionisation Ignition Spark Boiler Output (Mean 70 C) kw 229.8-1156.4 Boiler Output (Mean 40 C) kw 255.2-1257.8 Boiler Input (Gross cv) kw 1309.6 Gas Inlet Size 2 x G2 NOx Rating/emissions at 0% O mg/kwh Class 6 (<40) HYDRAULICS Hydraulic Resistance (11 C T) mbar 24 Hydraulic Resistance (20 C T) mbar 96.6 Nominal Flow Rate (11 C T) l/s 26.9 Nominal Flow Rate (20 C T) l/s 14.8 Min Flow Rate (20 C T) (MAX MOD) l/s 2.96 Min Flow Temperature C 30 Max Flow Temperature C 90 Min Working Pressure bar 1 Max Working Pressure bar 6 Max Static Head Of Water metres 61 Condensate Connection mm 21.5 x 2 High Limit Set Point C 100 flow, 100 return 105 H/Ex Flow & Return Size 2 x G3 Water Content litres 150.6 FLUE/AIR INLET Flue Size mm 350 Flue Gas Volume m³/h 1829.6 Min-Max Flue Gas Temperature 80/60 C 50-63 Max Flue Resistance Pa 100 ELECTRICAL Electrical Supply 230/240V 50Hz 1 Ph Current (Max No Pump) Amp 2 x 3.35 Power Consumption Watt 1540 Modulating Input V/dc 0-10V Fuse Rating Amp 2 x 7 Controls Voltage V 24 or 240 Insulation Class IP IP20 CONTROL OPERATION On/Off 0-10V DC OpenTherm High Limit Protection Low Water Protection Volt Free Common Alarm Boiler Run Indication OPTIONAL EXTRAS Modulating Sequencer Kit, including DHW Tank Kit, Plant Room Sensor Kit, 6 Zone Expansion Kit Programmable Room Thermostat Kits Outside Sensor Kit DHW Tank Sensor Kit Safety Interlock Kit BACNet Gateway Kit LONWorks Gateway Kit MODBus Gateway Kit Remote Access Kit Sealed System Services Flow Manifold Kit Inlet Air Filter Kit Condensate Pump Kit Room Sealed Air Duct Kit Header Kit (flow/return) Header Kit (gas) Header Kit (air) FLOOR STANDING NOx CLASS 6 BIM *2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation. GET A QUOTE. W: IDEALCOMMERCIALBOILERS.COM Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification. 211225