THE PERFECT CONDENSATION

Condensing, pre-mixed, wall-hung gas boilers with water tank

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

Ideasandformsinevolution

1 VICTRIX ZEUS Superior kw I features

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

CITY OPEN - CITY BOX from 25 to 35 kw

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

VICTRIX Superior kw Export VICTRIX Superior kw X Export

BWA. CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

AIREX 2S WOOD PYROLYSIS SUCKING FAN

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

SPECIFICATIONS - NIKE

Ciao Green Condensing Wall-Hung Boilers

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

STILE BEAUTY AND TECHNOLOGY

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

High quality... SEALED PRE-MIXED MODULATING FAN SPECIAL METAL FIBRE BURNER FLAME DETECTION ELECTRODE IGNITION ELECTRODE FLUE OUTLET

Mynute Green Condensing Wall-Hung Boilers

Power X High Power Condensing Wall-Hung Boilers

The iqe Boiler Range. Combination and System T Boilers.

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

Power X High Power Condensing Wall-Hung Boilers

HIGH OUTPUT. Skin design RANGE

CAST IRON ATMOSPHERIC BOILERS

LIBRA DUAL INSTALLATION USE AND MAINTENANCE. Italian product. High quality IST 04 C

WHE 2.24 / WHE 2.24 FF

GAS CONDENSING TECHNOLOGY

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

PCH Heating Condensing Module for Air Handling and Roof Top Units

Exclusive Green E Condensing Wall-Hung Boilers

THE PERFECT CONDENSATION

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

Residential Heating Boilers

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A

KDE. PRESSURIZED STAINLESS STEEL CONDENSING BOILER FROM 124 kw TO 2160 kw

ENERGY TOP. Condensing boiler solutions

MINORCA KC - KR - KRB 24

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

MODULAR GAS CONDENSING UNIT EQUIPPED WITH PRIMARY RING and premix modulating Low NO x. from 100 to 900 kw and in battery up to 8 units

PCH/new Series. High performance, total flexibility

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

LOW NOx MODULATING GAS BURNERS

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

Tower Green HE Hybrid

TAHITI CONDENSING KR 55 - KR 85

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

Rapid. Suspended Warm Air Heater. Caring for the environment!

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

FORMENTERA KC - KRB - KR

4FLOOR-STANDING GAS CONDENSING BOILERS

UP TO 35 kw HE Collection

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

GAS ABSORPTION HEAT PUMP

WALL-HUNG GAS CONDENSING BOILERS MCR-P 24/28 BIC. HOMOLOGATION B 23P - C 13x - C 33x - C 93x -C 53 - C 43x - C 83x *

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

Seradens Super Seradens Super Plus

MODULEX EXT ENBLOC MODULATING BOILER

The guarantee on this appliance is valid for 12 months from the first day of installation.

EVE 05 RTN 24 - RTFS 24 CTN 24 F - CTFS 24 F CTN 24 - CTFS

General catalogue COMMERCIAL AND TECHNICAL INFORMATION. Commercial Range. March 2015 Edition

SGE Condensing Gas - Solar Water Heater

BORA BORA. BORA gas: the best suns THE MODELS BORA GAS ALL INNOVATION STRENGTHS

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

Rinnova Cond X. User manual and installation instructions

AFUE 95% Heating Input 50,000 to 200,000 Btuh

PROTEUS PLUS BLUE HERMETIC MONOTERMIC COMBI BOILER COMBI BOILER

WOLF GAS CONDENSING BOILERS COMFORTLINE

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

Bluehelix Tech RRT Wall-hung condensing boiler with Ferroli Thermobalance heat cell

USERS MANUAL FOR GAS BOILERS

MYdens T 5WARRANTY 1:20. Ti TITANIUM. commercial gas condensing boilers. boilers from 60 to 280 kw AISI 316 YEARS WORKING PRESSURE HEAT EXCHANGER

Wall hung combination

thea 35 MR/MN Kondens Wall-mounted condensing boiler

Transcription:

Flue gas condensation... The combustion process occurs when the oxygen in the air, supporting the combustion, and the gas are brought to a temperature such to start a reaction. This reaction is of exothermic type, that means heat releasing. A cubic meter of methane during combustion produces 10.13 kwh under form of thermal energy (sensitive heat), 1.6 kg of water under steam form (H 2 0) and carbon dioxide (CO 2 ). Latent heat recovery In traditional combustion boilers the steam, and its latent heat, is evacuated through the flue together with the flue gases. The purpose of the condensation technique is primarily to drastically reduce the latent heat dispersed in the flue gases, exploiting to the full the energy held in the fuel to obtain high efficiencies, impossible to reach using traditional systems. Use of energy in the flue gases To recover the energy accumulated in the flue gases as latent heat (or of vaporization) the condensing boiler is equipped with an extra large heat exchanger. This exchanger is designed so that the cold water, returning from the C.H. system, runs through its terminal part: the contact of the flue gases with this cold surface turns them from steam to liquid state (condensation), with relevant heat transfer to the water. This process means that it is possible to recover about 11% of the heat that generally would be lost in the flue gases, thus obtaining from the combustion of one cubic meter of methane a thermal energy of 11.25 kwh instead of 10.13 kwh. 1 2 3 1 Smoke ways 2 Cold wall 3 Condensate drops from cold wall 4 Smokes sent to the flue duct, practically without any water steam 5 Condensate drain 5 4

for the maximum energy exploitation (efficiency = 107%) The amount of heat that can be recovered from the flue gases, and therefore the amount of condensation produced, is inversely proportional to the working temperature of the system. The condensation technique is thus ideally suited in systems where the return temperature is as low as possible: the ideal system is, as a result, the heating system using radiant panels (floor heating systems). Efficiency (%) KONDENSAL EFFICIENCY Efficiency higher than 100% The capacity of a fuel to produce thermal energy during the combustion process is calculated by its Calorific Value. In general it can be said that the C.V. is the quantity of heat developed in the combustion of a unitary quantity of fuel 1 m 3 in the case of natural gas. Usually a distinction is made between G.C.V. (Gross Calorific Value) and N.C.V. (Net Calorific Value): the G.V.C. is the quantity of heat, freed through the complete combustion of 1 m 3 of gas, supposing to recover the latent heat contained in the steam present in the flue gases as well; the N.V.C. is the amount of heat, freed by the combustion of 1 m 3 of gas supposing that all the water contained in the flue gases, as steam, stays steam. The difference between the two calorific values is thus given by the value of the steam condensation heat held in the flue gases. Up until now, as it had never been possible to recover this heat with traditional boilers, only the N.C.V. was calculated when evaluating the efficiency. This is why, when speaking of condensing boilers, efficiencies higher than 100% can be reached. TRADITIONAL BOILER Output (kw)

An aluminum motor A high performance enbloc body Like the new car engines, the core of KONDENSAL is a single block made of diecast aluminum, extremely light and resistant. Advantages: highly corrosion resistant, therefore longlasting compactedness maintenance almost zero high silentness WOOD CLOCK 15 20 42 NOISE LEVEL 42 (dba) KONDENSAL 50 LIBRARY 70 OFFICE 75 TELEVISION

Premix combustion: intelligent and ecological output The output of KONDENSAL varies according to the speed of the electronically controlled fan. Whatever the output level, therefore whatever the number of rotations of the fan, the airgas mixture is always right. Advantages: a high powered fan means that long and complex flue ducts can be used maximum output is automatically self adapting to the length of airflue gas ducts, ensuring perfect combustion (CO2=9,4%) the modulation range is very wide all over the modulation range the combustion is always perfect and with low polluting emissions higher efficiency, due to the premix combustion high temperature of the dew point traditional boiler traditional boiler EMISSION COMPARISON maximum environment respect The special structure of the burner, made of stainless steel wool net generates a combustion at a temperature of 1100 C and allows: NOx emissions < 20 ppm CO emissions < 8 ppm and consequently a very low environmental impact. MAXIMUM LENGTH OF DUCTS (total) 50 m MAX OUTPUT 65 m REDUCED OUTPUT 75 m REDUCED OUTPUT LOAD 100% 73% 30%

Personalized comfort with high energy saving KONDENSAL is fitted with a modern microprocessor that controls all the functions. It can be approached through a simple luminous display and six push buttons. Basic operating values (Combustion ratio, automatically selfadjusting heating program) are preset. The real value of the boiler temperature is compared with the temperature calculated by the microprocessor during the heating or domestic hot water mode by means of the C.H. flow, return and D.H.W. temperature sensors. When the data have been collected the microprocessor regulates the fan speed and then the supply of combustion air. Consequently the burner, designed to recall the exact amount of gas needed in each moment thanks to negative pressure created by the fan always guarantees the ideal air/gas ratio and thus a constantly high efficiency at whatever level. KONDENSAL becomes a refined thermal regulating system when connected to an appropriate outer sensor or to a modulating thermostat (provided as an option). This makes it possible, for the room temperature, to be kept constant despite variations in the external temperature, by regulating the temperature of the heating systems (radiators etc.) completely automatically. KONDENSAL guarantees to the user fully automatic maximum performances. Panel board DHW temperature regulation CH temperature regulation Push buttons for increasing/decreasing selected values Display Possibility of thermoregulation connection OnOff main switch Reset push button Mode selection Digital manometer Digital thermometer (CH and DHW)

The KONDENSAL electronic management evolution allows, in a simple, efficient and economic way, to solve the problems of heating zones at different temperatures. The possibility of connection to the electronic card of the modulating chronothermostat TM 2000 allows, as indicated into the figure, to manage different zones at different temperatures and priorities. The connection flexibility is so high that engineers and installers can choose completely automatic functions controlled at distance by TM 2000, a real remote control. By connecting an outdoor sensor, it will be possible a temperature adjusting as a function of the outdoor temperature. TM 2000 (optional): The information appearing on the main display, always of easy interpretation, indicates all the available data sent by the boiler electronic card. The three push buttons give access to the different modes on the preset programs: antifrost protection mode heating program 1 and 2 setpoint timings for switching ON and OFF the boiler continuous regulation economic reduction 65 Installation at low temperature for floor heating system Installation at high temperature for radiators By opening the small front cover, in correspondence of the three push buttons appear other symbols, that allow to modify the parameters; these functions are also used by technicians for an easier starting up and maintenance of the boiler. Besides the functions of modulating room chronothermostat, the remote control allows: for the user: the visualization and selection of all the control parameters the remote ignition, by phone, using a dedicated interface (not yet available). for the service men: the visualization and selection of all the operation and safety parameters the store of the 4 latest lockout codes detectes.

KONDENSAL R TFS 30 KONDENSAL R TFS 30 is a condensing, wall hung, gas boiler, for heating only. Fitted with a premix burner, it works either with natural gas or LPG and reaches an output of 30,4 kw in condensing conditions. The combustion chamber is airtight, making the boiler suitable for installation in any room, with or without ventilation, with complete safety. It can work at very low temperatures and consequently offers high efficiency, thanks to maximum exploitation of condensation energy. This makes it ideal for floor heating systems. The R version can be fitted with an optional kit, composed of a threeway valve and control sensor for a remote domestic hot water tank. This makes possible to have the most of the boiler s small size and also profit from its high capacity to produce domestic hot water. Furthermore, it s possible to connect this boiler to the exclusive D.H.W. Unical storage tank DSP 120.

Power and flexibility for floor heating systems The main components Silicon aluminum heat exchanger Flame modulation controlled according to absorbed power Circulating pump Panel board with insulation IP X 4D Safety pressure switch against lack of water Pressure indicator (display) Drain cock Filling cock Automatic airvent Temperature range in heating mode from 20 to 85 C Ready for managing a separate D.H.W. storage tank Expansion vessel Modulating P.C.B. (Printed Circuit Board) for electronic control (regulation, diagnostic, safeties) C.H. flow temperature NTC limit thermistor C.H. return temperature NTC limit thermistor Antifrost protection Multifunction digital display Template for plumbing connections Optional: kit for separate DHW tank, including threeway valve and connection pipes DHW tank DSP 120 with accessories

KONDENSAL C TFS 30 KONDENSAL CTFS 30 is a condensing, wall hung gas boiler, equipped with a premix burner, for operation with natural gas or LPG. Max. output is 30,4 kw, both during heating and instantaneous D.H.W. production. It is room sealed, fan assisted. Suction of combustion air and evacuation of combustion gases can be effectuated either by using coaxial type or separate ducts. All models have electronic ignition. Main components Silicon aluminum heat exchanger Flame modulation, controlled according to absorbed power Circulating pump Panel board with insulation IP X 4D Safety pressure switch against lack of water Bargraph pressure indicator (display) Drain cock Filling cock Automatic airvents Heating temperature adjustable from 20 to 85 C Hot water temperature adjustable from 35 to 65 C Expansion vessel Modulating P.C.B. (Printed Circuit Board) for electronic control (regulation, diagnostic, safeties) Thermostatic mixer in the DHW outlet Motorized threeway diverting valve Antifrost protection C.H. flow temperature and return NTC limit thermistors Multifunction digital display Template for plumbing connections

Constant temperature during domestic hot water drawing The KONDENSAL C TFS 30 s special construction has brilliantly resolved one of the main problems of instantaneous D.H.W. production boilers: the constant temperature during hot water drawing. To heat a primary tank having a 13 liter capacity (with inside a copper coil internal diameter 13 mm external diameter 15 mm and containing 1.3 liters of D.H.W.), insulated with high density polystyrene foam, KONDENSAL C TFS 30 exploits its continuous modulating output and characteristic thermal inertia present in the exchanger aluminium body mass. The maximum temperature factory preset is 65 C, but it can be regulated down to 35 C. The D.H.W. storage tank is kept at a constant temperature (factory preset at 65 C, can be regulated down to 35 C). Careful design ensures that exchange and insulation are very high. The domestic water to be heated enters the coil from the bottom and travels upwards through the 11 loops in countercurrent to the primary flow. At the outlet, a device, preset at 60 C, mixes the water to be used with cold water to avoid thermal shocks and sudden changes in temperature. The maximum domestic hot water flow rate that can be drawn with t of 25 K is 16,5 liters/minute.

KONDENSAL B TFS 30 KONDENSAL B TFS 30 is a condensing, wall hung gas boiler for central heating and D.H.W. production with a 60 liter storage tank and output of 30,4 kw. This model has an extremely powerful system for domestic hot water production. The vertical storage tank is enameled according to the Bayer method and offers the following characteristics: 60 liter domestic hot water always readily available at 65 C, adjustable up to 35 C. 9 minute max recovery time continuous flow rate of 16,3 liters/minute. The domestic hot water production Inside the enameled storage tank is present a steel coil of about 10 m in length, also enameled, which, together with the output of 30,4 kw exchanged in instantaneous D.H.W. production provides the fullest guarantee of hot water availability when required from more than one tap at the same time. Flame modulation The flame regulation that KONDENSAL uses even during domestic hot water production allows considerable energy saving. This permits heat delivery to be proportionate and electronically controlled according to the temperature of the domestic hot water in the storage tank. The lower the temperature, the greater the energy delivered.

High performances in the D.H.W. storage Main components Silicon aluminum heat exchanger 60 liter glass lined storage tank, with high density CFC free PU insulation Flame modulation regulated according to output absorbed Circulating pump Panel board with insulation IPX4D Safety pressure switch against lack of water Bargraph pressure indicator (display) Drain cock Filling cock Automatic airvents Heating temperature adjustable from 20 to 85 C Hot water temperature adjustable from 35 to 65 C Expansion vessel Modulating P.C.B. (Printed Circuit Board) for electronic control (regulation, diagnostic, safeties) Motorized threeway diverting valve C.H. flow temperature NTC limit thermistor C.H. return temperature NTC limit thermistor NTC sensor for DHW temperature control Antifrost protection Multifunction digital display Template for plumbing connections. Optional: DHW expansion vessel kit FOTO ITALIA

The fan with high manometric head Electronically controlled fan detail The boiler is designed to operate at constant efficiency regardless of the length of the air/flue ducts. KONDENSAL is equipped with a high power fan able to reach a net available manometric head of 80 Pa. When the length and geometry of the air suction and flue ducts varies it selfadjusts.the length with separate ducts of 80 mm dia. in a straight line can reach, at the maximum output, up to 50 meters. L autoadaptation annule tous les problèmes d évacuation The longer the air/flue ducts are and therefore the higher the pressure losses are, the greater the pressure of the fan will be to discharge the combustion gases and, consequently, the lower the gas flow rate sucked in will be. In case of difficult evacuations maximum outputs will be lower than those declared, but always with the maximum efficiency.

Air/flue ducts Air/flue coaxial ducts (type A accessories) The maximum length of the coaxial ducts is 3.5 meters with pipes 60/100 mm dia., and 8.5 m with pipes 80/125 mm dia.; for every bend added the maximum length allowed must be reduced by 1 meter. With Kondensal boilers, all the problems of flue gas evacuation eliminated by selfadjustment. Air/flue separate ducts ø 80/80 (type B accessories) The max. length of separate ducts is 50 meters; for every bend added maximum length must be reduced by 1 meter. Max. length, included coaxial adaptor on the boiler= 3,5 m Max. Hauteur heigth, maximale, included y compris coaxial le terminal terminal d évacuation = 8,5 m= 8,5 m DISCHARGE OF FLUE GAS INTO HORIZONTAL COAXIAL DUCTS ( ø 60/100 mm) DISCHARGE OF FLUE GAS INTO VERTICAL COAXIAL DUCTS ( ø 80/125 mm)

Easy to install... In order to facilitate the boiler installation, Unical provides an optional plumbing template. This allows a quick and easy boiler connection. By fixing to the wall the provided mounting jig with its center line in vertical position, it is possible to determine the exact positioning of all the pipes connections. The template will then allow you to effectuate all connections and carry out soundness tests without having to assemble the boiler. Optional plumbing templates M G R M C G F R R G M C F Optional kit for a DHW storage tank connection (NTC sensor for DHW priority, motorized 3 way valve, connection pipes, wiring). Optional DHW expansion vessel kit for kondensal BTFS 30.

... with mounting and plumbing template KONDENSAL R C cod. 00371030 KONDENSAL B cod. 00371031 389 509 909 883 65 65 65 65 M C G F R 189 65 78 59 R G M C F Key: G Gas connection 3/4 C D.H.W. outlet 1/2 F D.C.W. inlet 1/2 M C.H. flow 3/4 R C.H. return 3/4 Boiler fixing supports Optional accessories for temperature control Outdoor sensor Modulating chronothermostat TM 2000 OnOff room thermostat OnOff weekly programmable room thermostat Special optional accessory Wall fixing kit complete with siphon Conversion kit from Nat to LPG Positioning template kit Expansion vessel anti water hammer

Technical data Condensing conditions operation t 50/30 C Traditional operation t 80/60 C R TFS 30 KONDENSAL C TFS 30 B TFS 30 R TFS 30 C TFS 30 B TFS 30 Nominal output kw 10 30,4 10 30,4 10 30,4 8,8 28,4 8,8 28,4 8,8 28,4 Nominal input kw 9,2 29,2 9,2 29,2 9,2 29,2 9,2 29,2 9,2 29,2 9,2 29,2 Efficiency category (According EEC Directive 92/42) CE CE CE CE CE CE NOx class (according EN 483) 5 5 5 5 5 5 NOx (value according EN 483) ppm 30 30 30 30 30 30 Water efficiency at full load (100%)* % 104,6 104,6 104,6 97,1 97,1 97,1 Water efficiency at part load (30%)* % 107,9 107,9 107,9 107,3 107,3 107,3 CO2 level with G20 % 8,9 9,1 8,9 9,1 8,9 9,1 8,9 9,1 8,9 9,1 8,9 9,1 CO2 level with LPG % 10,2 10,3 10,2 10,3 10,2 10,3 10,2 10,3 10,2 10,3 10,2 10,3 Dew point with G20 C 53 54 53 54 53 54 53 54 53 54 53 54 DHW temperature setpoint range C 35 65 35 65 35 65 35 65 Thermostatic mixer preset to: C ADJUSTABLE ADJUSTABLE DHW Flow restrictor l/min 12 12 12 12 DHW production in continuous operation with t 25 K l/min 16,3 16,3 16,3 16,3 Max. boiler temperature C 90 90 90 90 90 90 Water content primary circuit l 4 15 10 4 15 10 Water content CH tank l 12 12 Expansion vessel capacity l 8 8 8 8 8 8 Water content DHW storage tank l 60 60 Max. pressure in CH circuit bar 3 3 3 3 3 3 Min. pressure in CH circuit Max. DHW. pressure Electrical supply Maximum absorbed power CE approval P.I.N. Net weight Max. water content CH circuit (90 C)** Max. acoustic emissions Gas pressure with G20 Gas pressure with G31 Gas consumption with G20 Gas consumption with G31 Fan speed Insulation Protection degree (IP) bar bar V/Hz W kg l dba mbar mbar m 3 /h kg/h rpm 0,5 230/50 130 1312 BM 3473 65 186 42 20 37 0,97 3,09 0,71 2,27 19005900 X 4D 0,5 7 230/50 130 1312 BM 3473 65 186 42 20 37 0,97 3,09 0,71 2,27 19005900 X 4D 0,5 7 230/50 130 1312 BM 3473 100 186 42 20 37 0,97 3,09 0,71 2,27 19005900 X 4D 0,5 230/50 130 1312 BM 3473 65 186 42 20 37 0,97 3,09 0,71 2,27 19005900 X 4D 0,5 7 230/50 130 1312 BM 3473 65 186 42 20 37 0,97 3,09 0,71 2,27 19005900 X 4D 0,5 7 230/50 130 1312 BM 3473 100 186 42 20 37 0,97 3,09 0,71 2,27 19005900 X 4D (*) reference value at 15 C/1013 mbar (**)calculated for a max. temperature of 90 C

Dimensions DIAGRAM FLOW RATE/MANOMETRIC HEAD AVAILABLE FOR THE C.H. SYSTEM Manometric head (m) min. max Flow rate Q (l/h) Key: G Gas connection C D.H.W. outlet F D.C.W. inlet M C.H. flow R C.H. return B Connection for external DHW tank 480 385 85 145 120 85 120 UPPER VIEW KONDENSAL R/C KONDENSAL B 913 880 930 898 600 473 85 232.5 282 120 85 120 K K M C G F R 95.5 72.5 57.5 79 65 110.5 144 BOTTOM VIEW UPPER VIEW 141 BOTTOM VIEW Cod. 28216GB Ed.2 11/2004

Unical AG declines any liability for the inaccuracies that may appear due to errors in transcription or printing. It also reserves the right to introduce those modifications to its products that it considers necessary or useful, without compromising the essential characteristics of the said products.