ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Similar documents
PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

Digital Meters 2002 SINCE 1974 CATALOG. Level Flow Temperature Pressure. PRECISION DIGITAL CORPORATION

4 & 8-POINT ANNUNCIATORS Instruction Manual

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Instruction Manual Model A

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

AO Annunciator Module

Two-Channel Gas Controller

Temperature Controllers

Oxygen (O2) Single-Point Gas Detection System

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

ESSEX ENGINEERING CORPORATION

21-light Remote Annunciator. Owner s Manual

Model 4001 Series Single Channel Controller

Model A1600 Series Annunciator

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Nov 08 PRODUCT SPECIFICATION SHEET

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100

AIS750 Series Alarm Annunciator

Multi-Gas-Controller MGC2

DNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Technical Manual. Level Alarm Unit CARLA & WIDS

PolyGard 2-channel Gas Controller MGC-03

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Power Supply Display Module PSDM. Installation and Operation Manual

UDC100 Universal Digital Controller Specifications

NT DUAL CHANNEL DISPLAY. User Guide

INTRODUCTION / TABLE OF CONTENTS

Exit Stopper. STI-6400 Series

Beacon 110 Gas Monitor Operator s Manual

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

Table of Contents SECTION PAGE

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

Commercial and Light Industrial Fire Alarm Control Panel

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Exit Stopper. STI-6400 Series

Danfoss gas detection units

RAM3 Remote Alarm Module

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

Model A1700 Series Annunciator

MODEL 5100 VOTING LOGIC MODULE

/8 DIN Level Indicator

RTD TEMPERATURE SENSING SYSTEM

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

Water Detection Controllers

Motorised Infrared Optical Beam Smoke Detector. User Guide

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Process Alarm Module RTA 421

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

Combustible Gas Detection and Control System

SINGLE CHANNEL SYSTEM TWO CHANNEL SYSTEM

EUROTHERM ONTROLS. Alarm Unit FULLY COMPLIANT. Product data

Danfoss gas detection units

Pioneer-R16 Gas Monitor Operator s Manual

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

FireNET Plus Wiring Instructions

Soft Start Series MP700 Solid State, Reduced Voltage

AL800ULADA. NAC Power Extender. Installation Guide

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Motorised Infrared Optical Beam Smoke Detector. User Guide

DTA. Motor thermistor relay. Benefits. Description

Across-the-Line SERIES MP300 Combined Manual and Automatic

vibration switch

Alarm Tone Generator Model AG17

Public Safety DAS Annunciator Panel

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

SIL725 Safety Annunciator

ESP TECHNOLOGIES LIMITED

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES

I/A Series 716C 1/16 DIN Temperature Controller

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Annunciation, Remote Monitoring, Control Industrial Control Panels

PMD-MXT -XX -XXX. Ordering Example. Model Input Channels Input Type. THC Thermocouple channels channels channels RTD RTD

PURGE/PRESSURIZATION SYSTEM

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

X11CA COMPUTER ANNUNCIATORS

Operating Instructions. For. Alarm Control Module. Model SSR 500

Variable Frequency Drive SERIES MP800 VFD

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

INSTALLATION INSTRUCTIONS

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Beacon 200 Gas Monitor Operator s Manual

Addendum for STI-6406 with Dual Access Control

20 Light Remote Annunciator

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Transcription:

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual From urgent alarms to routine messages, the PD141AFO VIGILANTE handles all types of operational messages with simplicity and economy. The VIGILANTE delivers clear, eye catching (and ear catching) information to the plant operators. Alarm outputs from Precision Digital meters, alarm relays, logic levels from 5 to 28 VDC, and switches for parameters such as temperature, pressure, flow, level and proximity can all be fed directly into the VIGILANTE. The VIGILANTE can be field programmed for ISA Sequence A or ISA Sequence F2A, (first-out) operation. ISA Sequence A operation detects both momentary and maintained alarms. ISA Sequence F2A also detects momentary and maintained alarms as well as which alarm occurred first. Two VIGILANTE may be connected together to provide up to 8 points of annunciation. If the system is programmed for ISA Sequence F2A, the VIGILANTE will detect which of the 8 inputs was first to alarm. Alarm message labeling may be performed either in the field with a laser printer, or for no charge at the factory. Front panel is NEMA 4X rated. PRECISION DIGITAL CORPORATION 19 Strathmore Road Natick, MA 01760 Tel 800-610-5239 Fax 508-655-8990 www.predig.com

ORDERING GUIDE MODEL: PD141AFO-2 PD141AFO-3 PD141AFO-4 DESCRIPTION: 24-48 VDC Power 115 VAC Power 230 VAC Power SPECIFICATIONS NUMBER OF INPUTS: 4 per VIGILANTE ; 8 per system TYPE OF INPUTS: Momentary or maintained: NO or NC switches: Each input circuit contains a pull-up resistor, so it is not necessary to provide external excitation to the switch. Open Collector Transistor: Open circuit voltage is approximately 5 VDC. Logic Levels: Low = 0 to.8 VDC; High = 4.7 to 28 VDC, input impedance - 100 Kohms. OPERATION: User field select: ISA Sequence A or ISA Sequence F2A, (first-out). OUTPUTS: Alarm condition indicated in 3 ways: 1. Relay: 1 SPDT relay (2 A @ 240 VAC) per PD141AFO. For failsafe design, the relay is energized in the Non-alarm State. In the case of a power failure, the relay will go to the Alarm State; (NC contact is connected to common). 2. Audible: Built-in horn, 75 db. 3. Visual: Red LED next to the alarm message. ALARM MESSAGES: Laser-printed, 2 lines at 10 characters per line, per message. Factory or field printable. POWER INDICATION: Front panel green LED. POWER: AC power: 115 VAC ±10%, 50/60 Hz, 3 VA. 230 VAC ±10%, 50/60 Hz, 3 VA. or DC power : 24-48 VDC, 2 W max, 500 VDC isolation. ENVIRONMENTAL: Operating temperature range: -10 to +65 C Storage temperature range: -40 to +85 C Relative humidity: 0 to 90% non-condensing ENCLOSURE: 1/8 DIN, high impact plastic, UL 94V-0. FRONT PANEL: NEMA 4X, panel gasket provided. CONNECTIONS: Removable screw terminal block (provided) accepts #24 to #12 AWG. WARRANTY: 1-year parts & labor. EXTENDED WARRANTY: Warranty may be extended an additional 12 months by returning the Product Registration Form within 2 months from date of purchase. 2

OPERATION The VIGILANTE can be field programmed for either ISA Sequence A or ISA Sequence F2A. ISA Sequence A MOMENTARY ALARM MAINTAINED ALARM CONDITION LED HORN Normal Off Off Alert Flash On Normal Flash On Acknowledge Off Off ISA Sequence F2A (first-out) MOMENTARY ALARM CONDITION LED HORN Normal Off Off Alert Flash On Acknowledge Steady Off Normal Off Off CONDITION LED HORN 1st Pt Next Pt Normal Off Off Off Alert Flash Steady On Normal Flash Steady On Acknowledge Off Off Off MAINTAINED ALARM CONDITION LED HORN 1st Pt Next Pt Normal Off Off Off Alert Flash Steady On Acknowledge Steady Steady Off Normal Off Off Off 3

SETUP The VIGILANTE can be set up without removing it from its case. Setup of the VIGILANTE involves two choices: 1. ISA Sequence A or ISA Sequence F2A 2. Alarm designated by a high (or open) input or by a low (or closed) input. A switch located next to the screw terminals at the rear of the instrument is used to select the sequence under which the VIGILANTE will operate. Slide this switch toward the front of the instrument (marked A on the PCB) for ISA Sequence A operation. Slide this switch toward the rear of the instrument (marked F2A on the PCB) for ISA Sequence F2A (first out) operation. Alarm on a contact opening or closing is determined for each channel by a switch located beside the message LED for that channel. When a switch is in the forward position, that channel will alarm when the input contact is opened. If a switch is in the rear position, that channel will alarm when the input contact is closed. Access to these switches is gained by removing the VIGILANTE ' cover. The VIGILANTE ' cover is held in place by 6 latches that snap into notches on the snapoff cover. To remove the snap-off cover from the VIGILANTE, grasp the cover firmly on its short sides and pull it forward. The latch plate remains around the VIGILANTE ' case. 4

SIGNAL & POWER CONECTIONS CONNECTING TWO VIGILANTES TOGETHER Two VIGILANTE may be connected together to form an 8 input system. If the VIGILANTE are programmed for ISA Sequence F2A, they will detect which of 8 inputs was first to alarm. The Acknowledgment switches will be wired together, so either one can be used to acknowledge an alarm. However, each VIGILANTE ' relay will operate independently, so it may be necessary to wire them in parallel to drive a single alarm device. Each VIGILANTE ' horn also operates independently. Connections PD141AFO Terminal PD141AFO Terminal 5

ALARM MESSAGE LABELS Alarm message labels for the VIGILANTE may be factory-printed for no charge, or field-printed using a laser printer with clear self-adhesive labels. Factory Printing of Alarm Message Labels Factory-printed alarm message labels may be ordered at any time, at no charge, by completing the following form. (Note: message #1 is the top message & message #4 is at the bottom.) Make copies of this page for additional alarm message labels that have different messages. Please include label with my order I have the PD141, please send ASAP Quantity Name Company Mailing Address City, St, Zip Phone PO# Message No. 1 Message No. 2 Message No. 3 Message No. 4 6

MOUNTING DIMENSIONS Notes: 1. Dimensions: A: 4.83" (123mm) req'd for installation B: 4.30" (109mm) installed C: 4.25" (108mm) D: 2.30" (59mm) 2. Panel cutout required: 3.62" X 1.77" (92mm X 45mm) 1/8 DIN 3. Panel thickness:.125"-.250" (3.17mm-6.34mm) 4. Weight: 11.4 oz (325g) 5. When mounting two VIGILANTES, either side-by-side or one on top of another, separate cutouts must be made for each VIGILANTE to maintain the NEMA 4X rating. Accessories PDA2407 PDA2411 PDA2412 PDA2444 PDA2446 NEMA 4X enclosure for 1 meter NEMA 4X enclosure for 2 meters NEMA 4X enclosure for 3 meters Explosion-proof enclosure for 1 meter Explosion-proof enclosure for 2 meters 7

OTHER PRECISION DIGITAL PRODUCTS PD690 Universal Process Meter PD691 Universal mv Strain Gauge & Load Cell Meter PD692 Analog Input Flow Totalizer PD693 Frequency/Pulse Input Flow Totalizer PD694 0-200 DC Volt Meter PD695 True RMS AC Volt Meter PD750 Universal Temperature Meter PD696-PD698 Loop-powered Totalizers Loop-powered Meters 3½, 3½ + Extra Zero, & 4½ Digits 0.4, 0.5, 0.7, & 1 Inch High Digits Panel Mount, NEMA 4X, & Explosion-proof PD118 Minimux 8 Point Scanner Adjustable Scan Rate Easy PLC Interface Built-in Horn PD128 PLC Annunciator PD650 NEMA 4X 2.3 Large Display Process Meter PD655 NEMA 4X 1.0 Large Display Process Meter PD656 Explosion-Proof 0.8 Large Display Process Meter PD755 NEMA 4X 1.0 Large Display Temperature Meter PD756 Explosion-Proof 0.8 Large Display Temperature Meter How to Contact Us: For Technical Assistance please call (800) 610-5239 or Fax (508) 655-8990 For Sales Support or to place an order please call (800) 343-1001 or fax (317) 272-2873 For Warranty Registration and Double Your Warranty On-line, please visit our web site @ www.predig.com 8