TRIO Rx. Portable Ultra- High FAC Decanter Activator Set Instruction Manual

Similar documents
Instructions for set-up, use and cleaning

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

PERSONAL Ultrasonic Cool Mist Humidifier

Instructions for set-up, use and cleaning. babybrezza.com 2017 Baby Brezza Enterprises LLC

User Guide & Warranty Information

Installation Guide. Manufactured for Aero-Spa, LLC Web:

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

Ultrasonic Aroma Diffuser AD-SD1-CE

Sterilizing Washer E2S-7000 Operating Manual

Operator s Manual. Frozen Beverage Granita Machines

A few simple steps to ensure perfect water, every time.

Installation & Operating Instructions

Compact Fabric Steamer

Hydrogen Water Pitcher

BL250. Pulse Blender OWNER S GUIDE

K-COMPACT Use & Care Guide. Get the most from your new Keurig brewer

WARNING: Warns of health hazards and identifies possible risks of injury. CAUTION: Indicates possible dangers to the machine or other objects.

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

USER MANUAL. Bottled Water Dispenser SAVE FOR FUTURE USE. Model #

INSTRUCTIONS FOR OPERATION AND CARE OF

INSTRUCTIONS MANUAL. 1.8L Electric Kettle with Multi-Temp Feature SK-1800R (Red) SK-1800SS (Stainless Steel)

DZ5080 US Index01 19/09/07 10:50 Page 2

STEAM MOP S3251NZGN OWNER S GUIDE

4L Instant Water Boiler Instructions for Use

Instruction Manual. Please read these instructions fully before using this product. Smart Living Steam Mop. With all new design enhancements

Instruction Manual. Nonstick Ceramic Ultra Steam Iron. Wards.com Powerf MODEL: SG Item No.: V~, 60Hz, 1200W

ADORABLE Ultrasonic Cool Mist Humidifier

1600 Watt Professional

PERSONAL COOL MIST ULTRASONIC HUMIDIFIER

CORDLESS GLASS ELECTRIC KETTLE WITH BONUS TEA INFUSER

RJ11-17-TI CORDLESS GLASS ELECTRIC KETTLE. CUSTOMER SERVICE:

SALT WATER CHLORINE GENERATOR. Model: SMC20TA & SMC30TA SMC INSTRUCTION MANUAL

Ultrasonic Cool Mist Humidifier

READ CAREFULLY AND KEEP FOR FUTURE REFERENCE

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

OXYGEN CONCENTRATORS Information For Our Customers

FOR THE FOLLOWING MODELS: If you have any questions about the operation of your ultrasonic humidifier, please contact Crane Customer Care.

Brita. Water Filter & Chiller. Instruction Booklet WF6000. Please read these instructions carefully and retain for future reference.

Table of Contents. English

Contents. AFTER SALES SUPPORT / FJ142L

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR DRYER MODEL C80004

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

P.N User Manual STAINLESS STEEL ELECTRIC KETTLE 5964/5965 Series MODELS

STEAM LITE S3251UKJR OWNER S GUIDE

mini kettle Model # Operating Instructions Warranty 650 Watts / 120 V / 60 Hz

6L PRESSURE COOKER. Instruction Manual. Model: PLA1424

COVER MODEL# GDK240 DIGITAL KETTLE. PHOTO OF PRODUCT

P.N ELECTRIC KETTLE User Manual Series MODEL BVSTKT308

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR DRYER MODEL C80002

ULTRASONIC HUMIDIFIER

Vortex Steam Mop SSM-0418

Dome Kettle. polished stainless steel body BTDK120

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL

JUNEAU JUN. 08/51193/0 Issue 0

Single cup Brewer User Manual

KETTLE WK 6330 ENGLISH

K-SELECT Use & Care Guide. Get the most from your new Keurig brewer

Whynter Portable Ice Maker 33 lb capacity - White

EZ1 XL FLOOR STEAMER INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: EZ1 XL

Dynamo & Dynamo Pro Steam Mop & Sweeper SSS-2618 SSS-5618

Actual product may differ from the one illustrated

INSTRUCTION MANUAL MNBX14

DIGITAL Warm & Cool Mist Humidifier

Professional SLIM STEAM POCKET MOP S3455UKJR OWNER S GUIDE

SF-707 MIGHTY STEAM IRON OWNER S GUIDE

MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL

Electric Digital Kettle

Cool Mist Ultrasonic Humidifier

Programmable Cordless Water Kettle with Variable Temperature Control PRO. Operating Instructions Warranty. Model #275 /#276

Steam Iron Instruction Manual MODEL: SG Ginnys.com

1.5 L Electric Kettle

1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER

Garment Steamer Model SC620

Eco-Steamer SSC-0312 INSTRUCTION MANUAL CONTENTS

EVAPORATIVE COOL MIST HUMIDIFIER Instruction Manual

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

MONSTER FLOOR (SC1Z1) INSTRUCTION MANUAL. CUSTOMER SERVICE: (AUS) (NZ) Model #: SC1Z1 AUS, NZ

CLEAN MIST DUAL TANK SMART HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A

S3501 N2 S3501BB N OWNER S GUIDE

BarAid 400. Installation and. Starting from Serial No.:

Pre-Installation Instructions. Installation Instruction. Installation Instructions. kah. wall. Warning. User s Manual and warranty

INSTRUCTIONS AND WARRANTY

USE AND CARE MANUAL. Before operating the iron, please read these instructions carefully and keep them for future reference.

S3501SP N2 OWNER S GUIDE

LIGHT & EASY STEAM MOP S3251 OWNER S GUIDE

Contents. AFTER SALES SUPPORT CCW /

Aqua Laser, Aqua Pro, Aqua Pro V Steam Mop SSM-0618 SSM-3618 SSM-4618

ROX-10WB-E WATER ELECTROLYZER INSTRUCTION MANUAL FOR END USER L188AU111 (100507)

CLEAN MIST SMART HUMIDIFIER TABLETOP & FLOOR STANDING WITH REMOTE CONTROL. Instruction Manual and Warranty Information

EcoMaster - Residential Pools up to 40,000 Gallons

Installation Guide. Manufactured for Aero-Spa, LLC Web:

OPERATION MANUAL. Model: IC702/703 Ice Maker

EN Variable Temperature Electric Kettle

product safety Please read these instructions before operating the appliance and retain them for future use.

HANDHELD STEAM SCRUBBER S3401 OWNER S GUIDE

1.7L Kettle Model Number KE2400 INSTRUCTION MANUAL. After Sales Support Telephone:

FagronLab NP-1 UV. Negative pressure workbench. User Manual

2 IN 1 JUICER AND BLENDER

AI-215 Series Portable Ice Maker

Arrow HIGH PERFORMANCE CORDLESS VACUUM LET S GET STARTED. 20V TBTSV1B1

Transcription:

TRIO Rx Portable Ultra- High FAC Decanter Activator Set Instruction Manual Point of use production of activated cleaner and sanitizer/disinfectant Environmentally responsible Effective on hard surfaces Removes the need for transport and storage GenEon Technologies, Inc. Corporate Offices 16026 University Oak. San Antonio, Texas 78249 T: (866) 217-0205 F: (210) 547 2750 www.geneontechnologies.com GenEon Technologies, Inc. Houston Distributor Center & Office 4268 Clark Rd. Houston, Texas 77040

Contents Introduction and notices..2 Pack contents.3 Safety instructions.4 Quick Start Guide 5 Base station lights..6 Setting Up Your TRIO Rx.....6 Creating Disinfectant....7 What Is GenEon Disinfection Solution Chemistry...8 Test the GenEon Disinfecting Solution...8 Filling Your Spray Bottle...9 Disinfecting Surfaces with GenEon Solution...9 Clean.9 Disinfect.....9 Water Quality....10 Warranty..10 Troubleshooting...11 Product specification.. 11 ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

Congratulations on purchasing a GenEon TRIO Rx. You now have the assurance and peace of mind from a product made to the highest manufacturing standards backed by a comprehensive warranty. Please complete and return the warranty card provided. We hope that you will enjoy using your product for many years to come. These instructions will show you how to use the TRIO Rx safely. /////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// Notice for customers in the countries applying EU Directives This product has been tested and found compliant with the limits set out in the EMC Directive and is fully CE compliant. Disposal of Old Electrical & Electronic Equipment (applicable in the European Union and other European countries with separate collection systems) The symbol on this product or on its packaging indicates that this product shall not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. Contact your local civic offices for further information.

Pack Contents Thank you for purchasing the GenEon TRIO Rx. The GenEon TRIO Rx is the first and only table top disinfectant generator that produces hospital grade disinfectant on demand using tap water and minerals! Parts Supplied: (1) Pitcher with lid for Solution Activation (64 fl. oz. / 2 Liters) (1) Base Unit (1) Power Transformer and cord (VAC 100~240, 50~60Hz.) (1) Instruction Booklet (1) Box (12 Electrolyte Packs creates 6 Gal. / 23 liters of Disinfectant) (1) FAC Pack of Test Strips (3) Secondary Labels These instructions will show you how to use the unit safely and protect you from danger or damaging the unit (The following images of the product might be slightly different from the one supplied.) Activator Base Pitcher & Lid Electrolyte Packs Transformer & Power Cord. FAC Test Strips

CAUTION: USE ONLY AS DIRECTED Safety Instructions Use only as directed for disinfection of hard surfaces Follow instructions for use Be certain to train new staff members on use of the machine prior to operating In case of contract with eyes, rinse immediately with plenty of water and seek medical attention Do not use base station near an naked flame During creation of disinfectant use machine in a well-ventilated area Avoid directly inhaling disinfectant during generation Keep out of reach of children and pets Unplug base unit from electrical source after use Do not move the machine during operation as the cycle will not completely finish Do not overfill or under-fill pitcher Follow directions on electrolyte packet. Do not use more than is indicated on the packet. Allow machine to rest 2 minutes between cycles when brewing more than one pitcher Directions for safe use Do Not overfill or under-fill the pitcher. DO NOT pour in too much Electrolyte the device will automatically stop if excessive Electrolyte is used. Use the Electrolyte as directed. Produce only as much solution as necessary and use as instructed. Dispose any unused solution safely. Unused solution can be disposed in a sink. The sanitizing and cleaning potency of electrolyzed water will be reduced if the water is stored for long periods. Keep bottle in an upright position. Important Note: Please follow the instructions in the Making the cleaning and sanitizing solution section before making the solution that will be used to clean and or sanitize. This product can be used with electric source of AC100~240V, 50/60 Hz. Do not use ground water, polluted water or excessively hard water to fill the bottle or pitcher. Use water temperature ranges 41 F to 104 F

Quick Start Guide Plug unit into power source Fill canister to the 2.3 L mark Add Electrolyte solution packet Run cycle Once cycle is complete solution is ready for use. Confirm FAC using a FAC Test Strip (picture not reflective of all FAC Test Strip) High-Range Free Available Chlorine 400+

Base Station Lights Lights on the base station 1. Blue light indicate that decanter is sitting correctly on Base 2. Operation panel with blue/ red start button and round blue light for operation Setting Up Your TRIO Rx Setting up is simple! 1. Select a location (the best locations are the sterilization area or laboratory, find a dry surface near a sink with a power outlet) 2. Connect the base station to the electric power supply using the transformer provided. 3. Plug in the power supply and the red start button on the front of the unit will illuminate and a beep will sound. 4. If the start button fails to illuminate check that the transformer is correctly plugged into the power supply and that there is power at the power outlet.

Creating GenEon Disinfecting Solution Using Liquid Pack 1. Fill pitcher to the 2 liter mark using Tap-Water I. Place the pitcher on a counter top to confirm that the water line is at the 2 liter mark. If the water line is not at the 2 liter mark, correct it as needed. II. Place the pitcher on the base unit. Ensure the pitcher handle is towards the rear and the spout facing forward. If placed correctly you will hear a chime and a blue light will illuminate around an already illuminated red power button. 2. Add the Electrolyte. Take one mineral packet and open it by tearing or cutting along the top of the packet. Pour the entire contents of the packet into the pitcher. Place the lid securely on to the pitcher. You are now ready to activate the machine: 3. Using your finger, lay it flat over the blue and red power button lights ensuring that contact is being made over both colored lights. Just touching the red center of the power button will not activate the machine. Note: Looking into the pitcher you will notice the stirring mechanism will rotate clockwise and counter clockwise in synchronization with the blue light. The machine will run for 15 minutes during its brew cycle. You will notice the water will get cloudy with bubbles as the disinfectant is being made. Please note that this is completely normal. Once the cycle is complete the machine will chime twice and the outer blue light will begin flashing. The outer blue light will continue to flash until you remove the pitcher from the base unit. GenEon disinfectant is now ready. IMPORTANT: In the event you wish to brew multiple pitchers one after the other, please let unit rest for one minute before brewing a new pitcher

What is the GenEon Disinfection Solution Chemistry? The GenEon TRIO Rx uses water, salt, and a ph adjuster and electrolyzes the solution. During the electrolysis cycle, salt (NaCl) is converted to hypochlorous acid (HOCl) and other chlorine species. HOCl is called Free Available Chlorine. Free Available Chlorine is used in water processing plants and swimming pools to disinfect water. HOCl is one of the oldest and well understood disinfecting solutions known to mankind. It is important to note that GenEon use its Propriety Catalyst when conducting the microbiological studies and CANNOT warranty ANY claims when non GenEon catalyst is used. Testing the GenEon Disinfectant Solution To test the strength of the solution, use the following steps: 1. Remove one Free Available Chlorine (FAC) strip from the test strip container provided with your mineral packets 2. Submerse the test strip into the disinfectant for one second 3. Remove the strip and shake it once away from your face or clothes. Wait exactly 60 seconds before comparing the test strip to the color chart on the bottle and then take the reading within 15 seconds The test strip color should be at 250-2000 parts per million (ppm). All microbiological testing was done at 1300 ppm or below.

Filling Your Spray Bottles Before filling you spray bottle, affix an Approved GenEon Disinfecting Secondary Label to the bottle. Remove the pitcher from the base unit and carefully fill your spray bottles. You may want to use a small funnel. Fill each bottle to the desired level and then securely tighten the spray head to the bottle sealing in your disinfectant. This will ensure that the solution does not degrade. Note: when store correctly solution shelf life can be up to 14 days. However, confirm the strength of the solution using an FAC test strip before using. Disinfecting Surfaces with the GenEon Disinfectant The GenEon disinfectant should only be used for hard surface disinfection. Use the following steps when disinfecting any surface. Note: the CDC recommends that surfaces be cleaned of gross soils before disinfecting. 1) Clean the Surface a. Spray the surface or the cloth, and then wipe the surface dry. i. It is recommended that you use cotton, microfiber or paper wipes. 2) Disinfect a. Spray hard surfaces and follow instructions on the Secondary Label. b. Then wipe dry using a paper towel or synthetic towel. Feel free to use the GenEon solution on all hard surfaces and dental chair fabrics. However, test color-fastness in an inconspicuous area before applying to visible areas. //////////////////////////////////////////////////////////////////////////////////////////////////////////

Water Quality for the Pitcher The water supply (potable water) MUST be from normal tap water with appropriate hardness. PH: 2.5-7 Hardness: less than 200 ppm Low calcium water recommended. Do not use ground water, polluted water or excessively hard water to make the solution. Water temperature range: 41 F to 90 F only. If your water is harder than 200 ppm and you are not using a water softener, we recommend you use distilled water. //////////////////////////////////////////////////////////////////////////////////////////////////// If you have any questions, please refer to your manual or visit us at www.geneontechnologies.com Thank you! GenEon Technologies, Inc. www.geneontechnologies.com Warranty Manufacturing and components defects are covered by a warranty and will be administered through your supplier. The standard warranty covers the base station and power transformer (excluding fuses), and pitcher for twelve (12) months. Replacements are available to purchase from your supplier. This warranty does not cover any malfunction caused by abuse, misuse or improper care including disassembling the Product, or by failure to follow the printed instructions included in the Product package. The Product should only be filled with potable water (tap-water) and with the manufacturer recommended Electrolyte. This warranty does not cover malfunctions caused by filling the sprayer or pitcher with any other liquid, including any cleaning or sanitizing fluids. Warranties implied by state law are limited in duration to twelve (12) months from the date of purchase. For full details of the warranty in your particular country please consult your local supplier. All claims must be made through your supplier.

TROUBLESHOOTING Please read the instructions carefully and use the check list below. Call your local supplier if a problem persists. Issue Check Points Remedy Nothing on the Display Panel. Is the power cord and plug connected properly? Plug in properly and switch on the power to the unit. No clear bubbles rising during operation. Why does the unit keep beeping? Why does the blue operation light lamp and the blue lighting lamp keep flashing? Device won t operate. Did you add the Electrolyte? Does the beep sound for 3 seconds after 15 minute full operation? Did the generating process finish? Is the pitcher sitting correctly on the base During the electrolysis process a complex gas with oxygen, hydrogen and chlorine is generated. Therefore, NO Bubbles means NO Catalyst. Prepare a fresh solution and try again. The normal process of electrolytic activation takes approximately 15 minutes. The beep sound indicates the electrolytic process is complete and sounds for 10 seconds before the full operation ends. The two blue lamps flash during operation. The unit will not run again until the pitcher has been removed and replenished. Lift pitcher and replace it on base. Device won t operate. Did the unit rest for 1 minute? The device will not run without at least 2 minute rest. No run lamp showing - only a flashing light. Display panel is lit up, but unit does not engage when I press the start button Did you press the start button repeatedly? Did you press both the red and blue part of the start button? When the electrolysis process is complete the device will NOT run again immediately for safety reasons. Press the start button engaging both the blue and red illuminate light with the flat of your finger. Issued: April 2015 Blue lamp not on. Did you press the start button? Press the start button. All lamps flash and there is a beeping sound. Did you add too much Electrolyte? PRODUCT SPECIFICATION Product Name TRIO Rx Model 8000 Rx If Electrolyte (s) are used excessively, the device will not run for safety reasons. Make a fresh solution and try again. Rated Voltage VAC 100 ~ VAC240 Distributor GenEon Technologies Electric Consumption 45w Manufacturer Geneon Technologies Generating Method Electrolysis EPA Est. 088681-KOR-001 Technical Term Electrochemical Activation (ECA) Number Supplier Refer to your invoice