A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

Similar documents
D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

TECHNICAL. Series 18. Pump Packages

SECTION STEAM CONDENSATE PUMPS

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

A. Codes and Standards that are Standard at the University:

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

SECTION PUMPS. 6. Section Steam and Condensate Piping and Specialties.

Design and Construction Standards SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

dualarm Vertical In-Line Pumps

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

SECTION HEATING BOILER FEEDWATER EQUIPMENT

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING

SECTION PLUMBING EQUIPMENT

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

University of Delaware

SECTION DOMESTIC WATER PUMPS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

SECTION PLUMBING EQUIPMENT

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

REFRIGERANT PIPING SYSTEM

SECTION HYDRONIC PIPING

WET AUTOMATIC FIRE SPRINKLER SYSTEMS

References are in agreement with UMRL dated April 2018 **************************************************************************

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Wilo IL Vertical Split-Coupled Inline Pumps

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Horizontal Split Case Pumps Type U

UNDP / PAPP OFFICE BUILDING RAMALLAH HVAC WORKS

MARLOW PUMPS RECIRCULATION

Division 23 - HVAC Switzerland Beallsville K-12. Section HYDRONIC PIPING SECTION HYDRONIC PIPING PART 1 - GENERAL

SECTION STEAM CONDENSATE PUMPS

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

SECTION WET-PIPE SPRINKLER SYSTEMS

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Ratio Architects, Inc. Section Refrigerant Piping

SPRINKLERS TABLE OF CONTENTS

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

A. Standard-Pressure Piping System Component: Listed for 175-psig minimum working pressure.

Full-line Product Overview

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

FLANGE-MOUNT CENTRIFUGAL PUMPS

SECTION STEAM CONDENSATE PUMPS

PROJ. NO SECTION REFRIGERANT PIPING

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

SECTION AIR COOLED WATER CHILLERS

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

UNIVERSITY OF MISSOURI Building Hydronic Piping and Pump Systems 2017 Q3

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. Open Impeller ASME (ANSI) B73.1 Pump for continuous use in Chemical Process Services

B. Shop Drawings: Detail fabrication of pipe anchors, hangers, special pipe support assemblies, alignment guides, expansion joints and loops,

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

B. Related Sections: The following Sections contain requirements that relate to this Section.

SECTION WET-PIPE SPRINKLER SYSTEMS

380 Series Multi-Stage Centrifugal Pumps

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

Transcription:

PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is to apply the principles of this section such that the University may achieve a level of quality and consistency in the design and construction of their facilities. Deviations from these guidelines must be justified through LCC analysis and submitted to the University for approval. 1.02 References: A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping. B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards." C. UL Compliance: Design, manufacture, and install pumps in accordance with UL 778 "Motor Operated Water Pumps." D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.. 1.02 Requirements: A. Avoid 3-1/2 and 5-inch pipe in chilled-water systems, except that 5 chilled water meters are acceptable. B. Drains and vents on chilled-water distribution piping shall consist of Schedule 80 thread-o-lets with stainless steel pipe nipples and bronze gate valves. C. All taps shall be constructed of 3/4" Schedule 80 Thread-o-Let, 3/4" 304/316 stainless steel nipples, and 3/4" bronze gate valve D. Provide means for access where valves and fittings are not exposed. E. Chilled water systems serving secondary loads shall be independently circuited from the primary chilled water system within the building and serve mechanical systems such as standalone computer HVAC, refrigeration equipment, etc. Each loop shall be provided with independent circulating pump. Pump shall be located in easily accessible areas for service and not above ceiling. Secondary loads shall be consolidated into a minimum number of separate chilled water circulating loops. Aggregation of equipment on such loops shall be approved in advance by the University. Design & Construction Standards, Revised November 2007 5.23.20-1

F. Chilled water design supply water temperature shall be 42 degrees F, with a minimum return water temperature of 58 degrees F to maximize the usable lifetime (optimize pipe size of existing piping) of water systems. This shall be accomplished without the use of blending stations. G. Provide sectional valves on each branch and riser, close to main, where branch or riser serves 2 or more hydronic terminals or equipment connections H. Provide drain valves on each mechanical equipment item located to completely drain equipment for service or repair. Install at base of each riser, at base of each rise or drop in piping system, and at any low point required to completely drain hydronic-piping system. I. Route groups of pipes parallel to each other, spaced to permit applying full insulation and servicing of valves. J. Select pumps on the ascending side of the efficiency curve. All pumps shall be non-overloading. K. In all cases, the PSP shall evaluate system conditions and select the optimum pump type and configuration based on efficiency and pump characteristics. 1. Recommend in-line circulating pumps or close-coupled end suction pumps for low flow (up to 50 GPM) circulating systems. 2. Recommend base-mounted end suction pumps for circulating systems with flow rates between 50 and 500 GPM. 3. Recommend horizontal split case, double-suction pumps for applications with flow rates exceeding 500 GPM. 4. Vertical in-line pumps shall be considered for applications with limited floor space and shall require University approval L. Provide pumps design to operate to 1,750 RPM unless directed otherwise. M. Provide pumps free of flashing and cavitation at all flow rates between 25% and 125% of design flow under the suction conditions of the pump installation. N. Provide pumps sized for critical speed of at least 115% of operating speed. O. Provide base-mounted pumps on minimum of 4" high concrete base equal or greater than 3 times total weight of pump and motor, with anchor bolts poured in place. P. Provide manufacturer s recommended clearances as a minimum. Indicate on Drawings required access space around pumps for service. Design & Construction Standards, Revised November 2007 5.23.20-2

Q. Design pipe changes off pumps using long radius reducing elbows or eccentric reducers to maintain top of pipe level. Provide piping support such that piping weight is not transferred to pump flanges or casing. Provide supports under elbows attached to inertia bases on pump suction and discharge. R. Provide a minimum of five straight pipe diameters at pump inlet connections. Suction diffusers only allowed if space constraints require their use. Provide line size isolation valve and strainer on pump suction piping. Provide line sized, sprint-loaded silent check valve and isolation valve on pump discharge piping. PART 2: PRODUCTS 2.01 Piping: A. Pipe Size 1/2" (connections to fan coil units): Type "L" copper w/ wrought copper fittings. B. Pipe Size 2" and Smaller: Black steel pipe; Schedule 40; Class 150 malleable iron fittings with threaded joints. C. Pipe Size 2-1/2" and Larger: Black steel pipe, Schedule 40, wrought-steel buttwelded fittings with welded joints. Mechanical/grooved fittings and couplings may be specified by the PSP. 2.02 Piping Specialties: 2.03 Pumps: A. Provide pipe escutcheons with inside diameter closely fitting pipe outside diameter, or outside of pipe insulation where pipe is insulated. Select outside diameter of escutcheon to completely cover pipe penetration hole in floors, walls, or ceilings; and pipe sleeve extension, if any. Furnish cast brass or sheet brass pipe escutcheons with nickel or chrome finish for occupied areas, prime paint finish for unoccupied areas. B. Provide strainers full line size of connecting piping, with ends matching piping system materials. Select strainers for working pressure of the piping system, with type 304, stainless steel screens. C. Provide dielectric unions as recommended by manufacturer for use in service indicated, which effectively isolate ferrous from non-ferrous piping (electrical conductance), prevent galvanic action, and stop corrosion. D. Sleeve Seals shall be modular mechanical type, consisting of interlocking synthetic rubber links shaped to continuously fill annular space between pipe and sleeve, connected with bolts and pressure plates which cause rubber sealing elements to expand when tightened, providing watertight seal and electrical insulation. Design & Construction Standards, Revised November 2007 5.23.20-3

A. In-Line Circulator Pumps: 1. Provide maintenance free units design for the working pressure of the piping system and 225 F continuous water temperature. 2. Wetted surfaces shall be non-ferrous materials. 3. Body: Cast iron with bronze or stainless steel fitted construction. 4. Shaft: Stainless steel; metal impregnated carbon thrust bearing. 6. Coupling: Self-aligning, flexible coupling. 7. Impeller: Bronze or stainless steel enclosed type, hydraulically and dynamically balanced, and keyed to shaft. B. Base-Mounted End Suction Pumps: 1. Provide horizontal base mounted, single stage, vertical split case, flexible coupling, designed for the working pressure of the piping system. piping system, and tappings for gage and drain connections. 3. Shaft: Steel with replaceable shaft sleeve. 4. Shaft Sleeves: 316 Stainless Steel with Buna O Ring Sealing between the impeller and the hub. Threaded to tighten when rotating in normal service direction. 5. Impeller Ring: Bronze. Easily replaceable. 6. Construction: Bronze fitted. C. Horizontal Split Case Pump: 1. Provide centrifugal, single stage, base mounted, direct connected. piping system, and tapping for gage and drain connections. 3. Shaft: 316 Stainless Steel. Design & Construction Standards, Revised November 2007 5.23.20-4

4. Shaft Sleeves: Bronze or Stainless Steel. 6. Impeller: Bronze 8. Drive: Flexible coupling with coupling guard. 9. Baseplate: Cast iron or steel. D. Vertical Inline Pump: PART 3: EXECUTION 1. Provide centrifugal, single stage, close coupled in-line, back pullout design. piping system, and tapping for gage and drain connections. 3. Shaft: 316 Stainless Steel. 4. Shaft Sleeves: Bronze or Stainless Steel. 6. Impeller Ring: Bronze, statically and dynamically balanced, and keyed to shaft. 8. Coupling: Axially split spacer coupling. 2.01 Pipe Testing Procedures: A. Refer to Appendix for hydronic pipe testing procedures. END OF STANDARD Design & Construction Standards, Revised November 2007 5.23.20-5