PNLDII-28 Condensate Drain Instruction Manual

Similar documents
OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

ThermoStar Refrigeration Air Dryers

Installation and Testing of Inverted Bucket Steam Traps Manual

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

Installation and Maintenance "L" and "LS" Series

Dry Air Pac ENGINEERED COMPRESSED AIR DRYING SYSTEMS FOR COLD STORAGE/ FREEZER ROOM DRY PIPE SPRINKLER SYSTEMS

Rotary Screw Compressors UP5 Series kw

INSTALLATION, OPERATION AND MAINTENANCE

UFM-T100H US ES CA Power Alarm Test TM

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS

Ingersoll Rand. Heatless and Heated Blower Desiccant Air Dryers ,900 m 3 /hr

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Installation Manual. Manual P/N rev. B. PRO Series Standard Rack Conveyor Dishwashers LISTED. Models.

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

Installation Instructions PP-AS20 Anti-Scale System

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

INSTRUCTION MANUAL HS-229G

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

SFD. Suburban Filter Dryer. User Manual Installation Instructions

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

H & HC Heat-Of-Compression Air Dryers

INSTALLATION AND OPERATION INSTRUCTIONS

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Clean Steam Generators

Humidistat-Thermostat

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

Armstrong ExpressPack Multi-Tube Steam Dispersion Panel Assembly and Installation Instructions

EMERGENCY DRENCH SHOWER

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

15Hp/20Hp Deluxe Compressor-Dryer System

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Installation, Operation, and Maintenance Manual

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Model NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

Air Dryers & After Coolers Dry Land

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

OPERATING INSTRUCTIONS

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

TORRID MARINE YACHT QUALITY Since Owner s Manual

TrueClean ToteCleaner

Corrosion Dry Air Pak

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

DHW Series INSTRUCTION MANUAL. Pressure Swing Desiccant Compressed Air Dryer Models 7 through 50 scfm

SECTION AIR COMPRESSORS AND ACCESSORIES

Model OP155 Air Dryer

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

TrueClean ToteCleaner

Digital Moisture Control Thermostat

MaxLite LED Round Pendant Highbay Series

PORTABLE AFTERCOOLER MODEL CA-350 PORTABLE AFTERCOOLER/FILTER AFTERCOOLER OPERATION MANUAL

No Touch Door Release Exit Sensor ACA-NTEB

Home Theater Interface Plate INSTALLATION INSTRUCTION

Installation Instructions

SCD. SMALL CYLINDER DRYER with Touchscreen Controller INSTRUCTION MANUAL MANUAL NUMBER Issued March 2015

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.)

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

TITAN FLOW CONTROL, INC.

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer

Ingersoll Rand 5-15 hp. Rotary Screw Compressors

FFP S700 SERIES. Pull-Out Spray Faucet. Installation guide

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

ECCOTEMP. Point of Use Tankless Water Heaters EP-2.4 / EP-7.0. Installation and Operating Instruction Manual. Shop Online.

Superdryer Dehumidifiers

Installation Manual DH6000T-VHR. Ventless Heat Recovery. Manual P/N rev. A

Read and save these instructions! DRANE-KOOLER. Water tempering device Installation, operation and maintenance manual

Indirect Cryogenic Cold Trap System Instructions

Operating Instructions Manual. Condensate Separators. Models 4GNL3 thru 4GNL9 and 53RG84 thru 53RG95

Model Combination Shower Eye/Face Wash

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Storage Tanks. Instruction Manual. To the Installer: Please attach these instructions next to the water heater.

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Installation, Operation and Maintenance Manual for Model 8331 Condensate Accumulator

Installation Manual. PRO Series Ventless Heat Recovery Rack Conveyor Dishwashers LISTED.

RK / RK Methane Detector Operator s Manual

Troubleshooting the MPH 24FP Series Pedestal Hydrant

Instructions Parts List. 150 psi (1.03 MPa, 10.3 bar) Maximum Air Inlet Working Pressure

INSTALLATION INSTRUCTIONS

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Ingersoll Rand. Refrigerated Air Dryers

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

V LPM Desiccant Air Dryer Installation and Operation Manual

OPERATING INSTRUCTIONS

OUTLET HOT INLET COLD INLET INSTALLATION

Transcription:

PNLDII-28 Condensate Drain Instruction Manual Installation and Maintenance More Than Air. Answers. Online answers: CCN:22810568 FEBRUARY 2006

Limited One Year Warranty This product is warranted to be free from defects in material and workmanship, under proper use, installation, application, and maintenance in accordance with the manufacturer s written recommendations and specification for a period of 18 months from the date of shipment from the factory or 12 months from the date of installation, whichever comes first. The manufacturer s obligation under this warranty is limited to, and the sole remedy for any such defect shall be, the repair or replacement (at manufacturer s option) of unaltered products returned to manufacturer within stated period. In order to process a claim, Ingersoll Rand must get from the customer a proof of purchase (date of purchase, invoice number). In no event, shall Ingersoll Rand be liable for business interruptions, loss of profits, personal injury, costs of delay or any other special, indirect, incidental, or consequential losses, cost, or damages. NOTE - Routine maintenance and minor adjustments to this product are not covered under this warranty. Prior to performing any possible warranty service or replacing a possible warranted part, please contact your local Ingersoll Rand authorized representative. All warranty claims must be performed by an Ingersoll Rand certified technician. Failure to comply with this procedure will result in denial of warranty claim. Page 2

Page 3

PRODUCT DESCRIPTION The PNLDII-28 is designed for trouble-free and maintenancefree draining of unwanted accumulations of condensation and other foreign matter from any collection point in a compressed air system without the need for electricity. INSTALLATION CAUTION: COMPRESSED AIR CAN BE DANGEROUS. Before attempting to install the drain, be certain that the pressure vessel on which the drain will be installed is completely depressurized. The drain should not be installed in areas that are exposed to freezing temperatures (heater option is available). Be certain the air system pressure does not exceed the 300 PSI working pressure of the drain and the pressure to the control system does not exceed 130 psi. The inlet temperature should not exceed 180 degrees F. Connecting the drain to the air system should be done by using one of the recommended installation diagrams shown herein. The installation of a strainer is not required or recommended. Install the drain as close to the source to be drained as possible. Since the PNLDII-28 uses gravity to fill the reservoir, the entire drain must be installed below the vessel to be drained when using the top inlet. If flexible tubing is used on the discharge, be certain it is properly fastened to prevent it from whipping when the drain discharges the condensation. The PNLDII-28 will accept condensation from either the top or the bottom of the reservoir. We recommend the use of the top entry port. If the bottom inlet is used, then a vent line must be used. The vent line should be installed down stream from the vessel that is being drained. This will insure that the air in the reservoir will properly exit as the condensation fills the tank and replaces the air. Install the vent line in the 1/8" port located on the side of drain. The other end of the vent line should be run back to the air system to a point just down stream from the source that is being drained. Use non-galling pipe sealant on all joints. The use of shut-off valves, unions and bypass valves is recommended. A backup wrench should be used on the discharge ball valve to prevent it from turning and causing the linkage to bind. The inlet port that is not used must be plugged by using a standard 3/4" npt plug. When using the top inlet, any reduction in the 3/4"pipe size is not recommended and the PNLDII-28 reservoir cannot be higher than the bottom of the vessel that is being drained. It is best to run the drain in a downward pitch from the bottom of the vessel being drained to the PNLDII-28 inlet. The power to operate the PNLDII-28 comes from compressed air. ONLY CLEAN DRY AIR SHOULD BE USED. The supply pressure should be between 55 and 130 psig. The PNLDII-28 is supplied with an inlet filter, which should be installed in the PNLDII-28 head. The use of unfiltered air can cause the drain to fail. Once the drain is installed, close the By-Pass drain valve and open the Shut-Off valve. The pressure vessel can now be repressurized. CHECKING THE DRAIN'S OPERATION After installation is complete and the drain is on line, a check should be made that the condensation is properly entering the reservoir. This can easily be done by looking through the translucent reservoir. If condensation is not entering the reservoir, check for the following: 1. Make sure the auxiliary shut-off valve is open. 2. Do not use the bottom inlet on the PNLDII-28 without installing a vent line. 3. If a vent line is installed, make sure it is down stream from the vessel that is being drained. 4. Be certain that the PNLDII-28 reservoir is not higher than the vessel that is being drained. This is very important when using the top inlet on the PNLDII-28 reservoir. 5. Check to make sure the vessel being drained has condensation in it. If the top inlet is being used and no condensation is entering the PNLDII-28 reservoir, and all the above items have been checked, we recommend that the bottom inlet be used with a vent line out of the top. If condensate fills the reservoir and the drain does not operate, check to see if control line air is supplied to control line port. If the drain is supplied with an optional test button, the supply of control line air can be checked by pushing the test button. If the unit does not operate, then no air is being supplied or the inlet filter is plugged. OPTIONS Cycle Counter High Level Alarm Heater WARRANTY The PNLDII-28 is warranted to be free from defects in workmanship and materials for a period of one year from the date of shipment. The liability of the manufacturer is limited to repair or replacement of the drain at its option. In no event shall the manufacturer be liable for special or consequential damages or for delay in performances of this warranty. CAUTION: Any attempt to repair the drain without authorization will void any warranty. Page 4

IN GENERAL In order for the condensate to properly enter the PNLDII-28 reservoir, the condensate line to the PNLDII-28 must always be installed below the bottom of the vessel to be drained. It is equally important to provide a means for the air that is contained in the reservoir to escape (vent) as the condensate enters the reservoir. If the air can not escape, the condensate will not enter the reservoir. Below are suggestions on how to best install the PNLDII-28 on typical types of vessels that have to drained of condensate. However, it is possible to install the PNLDII-28 without a balance line, providing the condensate enters the top inlet and the flow rates are less than 9 GPH (750 cfm for an aftercooler or 1500 cfm drier) for a 1/2" drain line and 19 GPH (1500 cfm for an aftercooler or 3000 cfm drier) for a 3/4" line. The use of unions and shut-off valves are recommended for both the condensate line and the balance line. RECEIVER TANK The preferred installation for a PNLDII-28 on a receiver tank is having the condensate enter the top inlet port and having the balance line go back to the tank at a position that is above the level of the condensate (Dwg. 1). FILTER and AFTERCOOLER MOISTURE SEPARATOR If a cyclone separator or filter has pipe plugs located in the top of the Dwg. 2 head, the plug closest to the discharge pipe should be removed and the balance line should be installed (Dwg. 2). If there is no provision on the cyclone separator or filter for a balance line, install it in the discharge side of the pipe line and as close to the cyclone separator as possible. REFRIGERATED DRYER If a balance line is required, it must be connected to the port located on top of the separator that is closest to the discharge side (Dwg. 2), or between the Vent Line separator and the air-to-air heat exchanger. If a port is not available as described above, then venting to atmosphere is recommended. When venting to atmosphere, the condensate should enter through the bottom entry port on the drain. The bleed or needle valve is installed on the 1/8" NPT vent port and allows the air in the PNLDII-28 reservoir to escape to the atmosphere (Dwg. 3). The bleed valve should be adjusted so that only 3 to 5 bubbles per second are visible. We do not recommend installing a vent line down stream from the dryer. The vent line can be a conduit for transferring moisture from the drain to the previously dried air. This can result in unwanted moisture being sent down stream. INTERCOOLERS Install the condensate drain line into the upper port only. This will prevent the possibility of condensate being drawn back into the intercooler on some systems. It is important that the vent line be installed on the same stage that is being drained or to atmosphere. BALANCE LINE As mentioned above, both the use and the placement of a balance line is very important. Most drain failures are the result of an improper balance line installation. The balance line should be 1/4" tubing or larger, and installed on top of a pipe or vessel, not the bottom. A needle valve is recommended for controlling the air flow. Avoid having any loops or low areas in the balance line that might allow moisture to collect in the line and prevent the passage of air from the drains reservoir. DWG. 1 DWG. 2 DWG. 3 Page 5

Page 6

ITEM CCN DESCRIPTION QTY. 1 38440889 CONTROL HEAD ASSEMBLY 1 2 38440897 INLET HEAD ASSEMBLY 1 3 38440905 FRP CYLINDER 1 4 38440913 RING AND FILTER KIT 1 5 38440921 TIE ROD KIT 1 6 38440939 CONTROL ASSEMBLY 1 7 38440947 CONTROL TUBING ASSEMBLY 1 8 38440954 AIR CYLINDER ASSEMBLY 1 9 38440962 BALL VALVE ASSEMBLY 1 Page 7

DISTRIBUTED BY: Disclaimer: Nothing contained within this brochure is intended to extend any warranty or representation, expressed or implied regarding the products described herein. Any such warranty or other items or conditions of products shall be in accordance with Ingersoll-Rand Standard Terms and Conditions of Sale for such products, which are available upon request. Product Improvement is a continuing goal at Ingersoll-Rand. Designs and specifications are subject to change without notice or obligation. c Ingersoll Rand 2006. Printed in USA. Ingersoll-Rand Co. Ltd Swan Lane, Hindley Green Wigan WN2 4EZ, United Kingdom Tel: +44 (0) 1942 257171 Fax: +44 (0) 1942 254162 www.ingersoll-rand.com Ingersoll-Rand Company 800-A Beaty Street, P.O. Box 1600 Davidson, NC 28036 USA Tel: +1 (704) 896 4000 Fax: +1 (704) 896 4648