Air heater/cooler in combination with ground source heat pump

Similar documents
Swegon CASA. duct coils for heating. the supply air

Swegon Home Solutions CASA. W3 Smart. Installation, commissioning and maintenance instruction. W3_f_EN-t

Swegon Home Solutions CASA. W9 Smart. Installation, commissioning and maintenance instruction. W9_e_EN-t

CASA. W5 Smart. Installation, commissioning and maintenance instructions. W5_d_EN-t

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

TECHNICAL SPECIFICATION

Swegon Home Solutions CASA. R3 Smart. Installation, commissioning and maintenance instruction. R3_d_EN-t

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

Swegon Home Solutions CASA. W4 Smart. Installation, commissioning and maintenance instruction. W4_c_EN-t

Swegon Home Solutions CASA. R3 Smart. Installation, commissioning and maintenance instructions. R3_f_EN-t

Installation and operation manual

Swegon Home Solutions CASA. R2 Smart. Installation, commissioning and maintenance instruction. R2_a_EN-t

Series VENTS VUT R WH ЕС

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

VERSO Air Handling Units

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

Swegon CASA W80 EC, version B

TopMaster Air Handling unit. Technical data

Primo Hotel. General. Indoor climate units for hotel rooms

Supply air unit VEKA Installation & Maintenance

Danfoss Air Heating Surfaces

VERSO Air Handling Units

KOMFORT EC DB Suspended heat recovery air handling units

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

AC25. Art.nr:

Supply air hood JSI-UV Installation-, adjustment and user guide

Instructions for the BASIC BCRW Fan, Sizes General

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections

NT 35/1 Tact Te. Tact system (Tact Automatic Filter Cleaning System) Ideal connections. High-quality, robust equipment.

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

VEX280H with rotary heat exchanger and EXact control system

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

NT 65/2 Eco Me. On-board storage. Integrated drain hose (oil-resistant)

VEX250H with rotary heat exchanger and EXact control system

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Wet and dry vacuum cleaners NT 65/2 Ap

Operation and maintenance instructions

COOLING / HEATING COILS

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

HEAT RECOVERY AIR HANDLING UNIT

Swegon CASA R120. Instructions for installation, operation and maintenance. R120_h_EN-m

NT 75/2 Ap Me Tc. On-board storage. ApClean (semi-automatic filter cleaning system) Integrated drain hose. Hose and bend attachment

ADAPT Parasol EX. Energy-saving, suspended comfort module QUICK FACTS

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

Planning guide. Atec.

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

Celebrating over 30 years of excellence in manufacturing ultrasonic cleaning equipment, electropolishing equipment and associated chemistries

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

NT 35/1 Tact. Multi-purpose wet & dry vacuum cleaner with Tact automatic filter clean system for heavy duty dust extraction.

Technical data. Danfoss DHP-L

Window Kit Installation Instructions

GREASE INTERCEPTORS. Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS

Scholar III Unit Ventilator

LOW STATIC HYDRONIC DUCTED UNIT

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

Air Handling Units. T F E.

Complements and Accessories

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

NT 75/2 Ap Me Tc. On-board storage. ApClean (semi-automatic filter cleaning system) Integrated drain hose. Hose and bend attachment

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

EC A1/L2 RIS P EKO RIS 400 P E 0.9 EKO 3.0 AIR HANDLING UNITS. Application

NT 65/2 Tact² Tc. Tilting chassis with container lock. Suction tubes and floor nozzles can be stored in any direction in the accessory holders

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

Wet and dry vacuum cleaners NT 65/2 Eco

COMMERCIAL STACKED. Supersedes repair parts list located behind lower panel on washer. Models: CGT8000AQ1 (White)

NT 40/1 Tact Te. Robust bumper and chassis. Ergonomic push handle

Technical data. Danfoss DHP-A

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

Climaster ZerAx. Eco-designkrav. Climaster ZerAx type ZCN-M guide GB

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

READ AND SAVE THESE INSTALLATION INSTRUCTIONS

PARAGON. Compact comfort module. Key figures

CONDOR. Supply air ceiling QUICK FACTS

Vallox INSTRUCTIONS FOR USE AND MAINTENANCE. Compact. Supply and extract air ventilation with heat recovery

Heat Recovery Units. Heat Recovery 1

5.0 Installation Instructions

Wet and dry vacuum cleaners NT 35/1 Tact (240V)

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

SKR series Steam Humidifier Kit N (Patent Pending)

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

TopMaster Air Handling unit. Installation instructions

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Maintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE

Transcription:

Swegon CASA Air heater/cooler in combination with ground source heat pump Installation, operation and maintenance instructions for design engineers, installation engineers and service personnel SDHWM_c_EN m

! Important information Only qualified personnel Only qualified personnel should carry out installation, configuration and commissioning. Observe the following during installation The air heater/cooler is installed in the outdoor air duct before the ventilation unit. The air heater/cooler must be mounted so that the air heater/cooler is horizontal in relation to the airflow. The air heater/cooler must not be installed in the immediate vicinity of the ventilation unit or duct bends, as this will prevent an even airflow across the air heater/cooler resulting in impaired output. Commissioning The air heater/cooler s duct sleeves must be covered during transport, storage and installation. Make sure that the air heater/cooler and the ducts are clean and that there are no loose objects in them before you commission the ventilation system. Ensure that the heating medium pipe system is mounted and insulated and that the venting sleeves are mounted. Do not commission the air heater/cooler until all work that produces large quantities of sanding dust or other impurities has been completed. Sizing the heating medium circuit Consideration must be taken during planning to the effect of the air heater/cooler. Ensure that the ground source heating well cannot freeze on account of the heater/cooler being added to the system. Supplement with the necessary protection. Included in the delivery: CASA W250F air heater/cooler, fully insulated Temperature sensor (T8) cable length 3 m SET connection unit RJ45 cable, 3 m, 2 pcs. Wall mounting bracket/ceiling mounting frame Wide-mesh filter Instructions Accessories: Condensate hose W2504F for the air heater/cooler: 502130 381 250 350 22 22 22 22 477 425 479 NOTE! The manual s original language is Finnish. 2 www.swegonhomesolutions.com Swegon reserves the right to make changes.

1. General Description In the winter the air heater/cooler heats the air taken in and ensures that the ventilation unit operates with the greatest efficiency even in extreme cold. In the summer, the medium in the ground circuit is used to cool the building. The control technology in CASA Smart ventilation units automatically enables the best utilisation of the air heater/cooler all year round. 2. Planning To observe during planning: when sizing the depth of the ground source heating well, review the capacity tables in the brochure and take into account the air heater/cooler s capacity for the established airflows. To size the pump, find out the heating medium flow and the air heater/cooler s pressure loss. Take the pressure loss caused by the air heater/cooler into consideration when sizing the airflows. The air heater/cooler must always be mounted horizontally, as condensate is formed during the summer and this must be led to a drain. Reserve servicing space at the sides of the unit in the plans. 3. Installation 3.1. Installation of the air heater/cooler in the duct system The unit is installed in the outdoor air duct when connected as preheater/chiller. The air heater/cooler must be mounted horizontally. Remember that the condensate outlet must be connected to the building's drainage system. There should be at least 500 mm free space in front of the hatch. The condensate hose is connected to the condensate outlet (G3/8"). The condensate is led off to a floor drain or the like using a hose with an inner diameter of at least 12 mm. The condensate hose (502130) is available as an accessory for air heater/cooler W2504F. The hose must not be led off directly to the drain. There must be two water traps or a horizontal section on the condensate hose. The damming height of the water trap should be at least 100 mm. Check that the condensate discharge outlet is not clogged and check its outflow by pouring water on the bottom of the ventilation unit. The condensate pipe must be placed in a heated space. A condensate pipe that is installed in a cold space must always be insulated with at least 50 mm mineral insulation or 30 mm cellular rubber insulation and fitted with a heating cable. The ducts are mounted on the air heater/cooler s Ø250 mm connection sleeves. The ducts are slid into the sleeves and locked with pop rivets. Keep in mind that the ducts insulation must run right up to the unit. After the air heater/cooler, the supply air duct must be insulated using 10 mm thick mineral wool in both the heated and cold areas (remember moisture insulation). The outdoor air duct, the ducts after the air heater/ cooler as well as the outgoing exhaust air duct must also be insulated against moisture (for example with a layer of plastic film above the layer with insulation or cellular-rubber insulation). 3.2. Pipe connections for the heating medium The pipes for the air heater/cooler s heating medium is connected to the unit s pipe connections (Cu 22 mm) for the outgoing solution and the return solution. Remember the need to vent the heating medium pipes in connection with the pipe installation. The air heater/ cooler s coarse filter must always be installed on the unit s outdoor side. The following must be taken into consideration when the air heater is connected to the pipe system: 1. The air heater/cooler s connection pipes must not be subjected to distortion or bending movements when the connections are made. Counterhold with a tool when assembling the couplings. 2. Ensure that the unit s expansion forces or the pipe system s own weight does not load the connections on the air heater/cooler. 3. To facilitate venting of the air heater/cooler, heating medium is generally supplied through the lowermost pipe on the heater/cooler. The venting valve is normally placed at the highest point of the pipe system. 4. The air heater/cooler and its connections must be checked for leakage once the pipe system has been completely filled. Swegon reserves the right to make changes. www.swegonhomesolutions.com 3

3.3 Electric and control cables Install the SET-connection unit in an appropriate position in the vicinity of the sensor and actuator. Connect the RJ45 cables (2 pcs.) supplied with the SET unit to the specified connections on the ventilation unit. Install the supplied temperature sensor in the outdoor air duct, before the air heater/cooler seen from the direction of flow. Connect the sensor to the SET module s free Sensor connection. Connect the heating medium pump s power supply to the SET-connection unit s other relay output according to the function diagram. Install any actuators according to the manufacturer s instructions and connect the control cable to the SET connection unit s relay outputs according to the function diagram. NOTE! If the SET module is used for 230 VAC control, the module must be installed, according to the electrical safety directives, in a separate enclosure. NOTE! Make sure that the strain relief is arranged for the connections according to the electrical safety directives.! Important! Only a qualified electrician may make the electrical connections. 4. Commissioning Commissioning the air heater/cooler is performed with a Smart control panel. Main menu/settings/(1234)/ Heating and cooling Commissioning of the air heater/cooler Select operation of the unit by highlighting the menu item External after heater. Limit value (heating) Select the required start temperature for external preheating. When the outdoor temperature (transferred outside temperature) measured before the air heater/ cooler drops below the limit value, the relays in the SET unit selected for the heat medium pump are activated. The operating signal is received from the relay output, for example, the heat medium pump and/or solenoid valve. Limit value (cooling) Select the required start temperature for external precooling. When the outdoor temperature (transferred outside temperature) measured before the air heater/cooler rises above the limit value, the relays in the SET unit selected for the heat medium pump are activated. The operating signal is received from the relay output, for example, the heat medium pump and/or solenoid valve. Select the functions for the temperature sensors used and fine adjust the measurements if necessary from the Sensor/Control menu. Sensors / controls Supply air Fine tuning Room air Room air sensor Fine tuning Supply air Supply air sensor 22,2 C 18,2 C 0,0 C Internal 0,0 C Internal Heating and Cooling Control type Sensors / controls Setpoint Setpoint (Away) Setpoint (Travelling) Internal post heater External post heater Post heater out limit External post cooling Supply air 17 C 17 C 17 C 8 C Outside air sensor Water radiator sensor SET Relay 1 SET Relay 2 Internal Internal Off Off Outdoor air sensor Select the SET sensor input (T6 T9) to which outdoor air sensor is connected: SET T6 -T9 = SET-connection unit s Sensor inputs. Internal = The unit s internal outdoor air temperature sensor. External electric preheater External liquid coil Liquid heating out limit -2 C Liquid cooling out limit 15 C Relay control functions Select the heat medium pump function for the SETconnection unit s relays. SET Relay 1 / SET Relay 2 = Heat medium pump. 4 www.swegonhomesolutions.com Swegon reserves the right to make changes.

5. Use and function Preheating with the heating medium is performed automatically according to the outdoor temperature through the unit s incoming air being heated in the winter and cooled in the summer. A minimum operating time (10 minutes) has been set for control of the heating medium pump. 6. Service! Important! Stop the ventilation before servicing. The unit s doors can be lifted from their hinges after their fastening catches have been opened. The radiator in the unit, can e.g. be cleaned by gently brushing the surface or gentle rinsing with water (only at low pressure). Any dirt that has accumulated on the bottom of the condensate tray can be wiped off using a cloth and mild detergent. The function of the water trap and drainage pipes for condensate water should be checked at least twice a year by pouring water in the bottom of the condensate tray. Swegon reserves the right to make changes. www.swegonhomesolutions.com 5

7. Function diagram and connections 9 24V 230V 4 3 2 1 NC NC max 250 V / 6 A Relay 1 4 4 3 2 1 NC NC max 250 V / 6 A Relay 2 SET Smart Extension Temperature module max 50 VDC NC NC NC Smart unit AO1 AO2 AO3 DI 1 2 3 4 5 6 7 8 9 10 11 12 SET2 SET1 Sensor T6 T7 T8 T9 1 0 10 3 T 2 8 1 5 6 M 24VDC 7 M 1: CASA Smart ventilation unit* 2: SDHWM air heater-cooler 3: Outdoor air temperature sensor 4: SET connection unit 5: Heat pump* 6: Solenoid valve* 7: Circulation water pump* 8: Extract air 9: Power source 24 VDC* 10: Operating switch for the circulation water pump ON/OFF* *) Not included in the delivery. 6 www.swegonhomesolutions.com Swegon reserves the right to make changes.

9 6 4 3 2 1 NC NC max 250 V / 6 A Relay 1 SET Smart Extension Temperature module 7 230 V 4 3 2 1 NC NC max 250 V / 6 A Relay 2! Important! If the SET module is used for 230 VAC control, the module must be installed, according to the electrical safety directives, in a separate enclosure. Make sure that the strain relief is arranged for the connections according to the electrical safety directives. max 50 VDC NC NC NC AO1 AO2 AO3 DI 1 2 3 4 5 6 7 8 9 10 11 12 Smart unit SET2 SET1 Sensor T6 T7 T8 T9 1 1 3 1: CASA Smart ventilation unit* 3: Outdoor air temperature sensor 6: Solenoid valve* 7: Circulation water pump* 9: Power source 24 VDC* *) Not included in the delivery. Swegon reserves the right to make changes. www.swegonhomesolutions.com 7

Air heater/cooler s performance data: Air heater/cooler s performance data Cooling: Capacity, kw 0.8 1.2 1.4 Air flow l/s 40 100 150 INCOMING AIR Temperature C 25 25 25 Relative humidity % 55 55 55 OUTGOING AIR Temperature C 13 17 18 Relative humidity % 95 87 82 INCOMING FLUID Temperature C 4 4 4 OUTGOING FLUID Temperature C 9 8.5 9.5 Fluid flow dm³/s 0.04 0.06 0.07 Pre-heating: Capacity, kw 1.0 1.4 1.5 1.7 1.8 Air flow l/s 40 60 70 90 100 Incoming air C -26-26 -26-26 -26 Outgoing air C -5-7 -8-10 -11 Air s velocity, m/s 0.4 0.7 0.8 1.0 1.1 Pressure loss for air Pa 5 9 11 16 19 Incoming fluid ºC 2 2 2 2 2 Outgoing fluid ºC -2-2 -2-2 -2 Fluid flow l/s 0.06 0.08 0.09 0.11 0.11 Fluid velocity m/s 0.3 0.3 0.4 0.4 0.5 Fluid s pressure loss kpa 5.9 7.9 8.7 10.0 10.6 Pipe connection DN 25 25 25 25 25 The unit's function for use as a preheater has been sized with 28% ethanol Pa 40 AIR HEATER/COOLER Pressure loss 30 20 10 0 40 60 70 90 100 150 Airflow rate l/s www.swegonhomesolutions.com