EC736 Grain Drying with Forced Air Circulation

Similar documents
CC196 Guide for Batch-Drying in a Bin

CC196 Revised with no date Guide for Batch- Drying in a bin

CC197 Guide to In-Storage Drying with Supplemental Heat

Aerating Farm -Stored Grain

Selecting Fans and Determining Airflow for Grain Drying and Storage

Management of In-Bin Natural Air Grain Drying Systems to Minimize Energy Cost

Aerating Grain in Storage

Grain and Soybean Drying on Georgia Farms

EC735 Hay Curing with Forced Air

AE-701 (Revised), November Dr. Kenneth J. Hellevang, PE Extension Agricultural Engineer

SQ SERIES DRYERS GRAIN MANAGEMENT SYSTEMS

9 - On Farm Storage and Drying

INSTALLATION AND INSTRUCTION MANUAL FOR BAC AERATION CONTROLLER

This circular is issued in cooperation with the Economic Research Service, U.S. Departmenf of Agriculture.

Seed Drying. 1. Surface moisture of the seed that initially removed by the drying air.

Monitoring Natural Air Corn Drying A Demonstration Project

EC738 Revised 1948 Conditioning and Storing Corn

TOWER DRYERS TOTA TOT L VA AL V LUE. TOTA ALUE. TOT L SYSTEMS. AL SYSTEMS.

EasyDry. Grain Drying Systems

i ;, ct. 6 COSTS OF DRYING AND STORING SHELLED CORN ON ILLINOIS FARMS I_(t e_

STORED GRAIN MANAGEMENT Roger C. Brook and Dennis G. Watson Department of Agricultural Engineering Michigan State University

Introduction to Fans. The Basics of Fan Principles and Terminology

A D VA N C E D E L E C T R O N I C G R A I N D RY I N G C O N T R O L S S Q S E R I E S D R Y E R S

Portable Dryers. Portable Grain Drying

DAE Systems. Fan Selection Guide. Section 1: Terminology

EC Shopping for a Mechanical Water Softener

PORTABLE GRAIN DRYING

Drying Groundnuts: Adapting the EasyDry M500 Portable Maize Dryer for Groundnuts

, 'I... " ENTILATION FOR SWINE / I / / I / I / UNIVERSITY OF flunois / I / SGRICULTUR~.uBRM~ '" ""'... I I \ / I I. , I \ CIRCULA~~G COpy I 1// 1\\

Grain Drying and Storage on Florida Farms 1

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

EC Energy Conservation in the Home : Heating

Fans: Features and Analysis

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

Chore-Time Fan Guide For Tunnel and Other Applications

F-Series Tower Drying

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Grain Dryer Efficiency. Presented by: Steven Morreim, President QED Dryer Sales & Mfg. Inc th Street Rockford, IL 61104

Ambient (ºF) Temperature Rise Above

Evaluation Report 578

SEED DRYING. Definitions 8/31/2017. Potential mechanisms involved in desiccation tolerance. Phases of Seed Development and Maturation

Solar Heat for Grain Drying --Selection, Performance, Management

Evaluation Report 422

for Growing Vegetables

ENGINEERING LETTER 4

Grain Handling, Drying and Storage Management

Installation, Operation, and Maintenance Manual

VENTILATING POULTRY laying HOUSES

INTERNATIONAL PORTABLE GRAIN DRYINGPAGE

RECIRCULATING BATCH & AUTOMATIC GRAIN DRYERS

Centrifugal Fans, Non-Overloading, Backward Inclined

Evaluation Report 521

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Select an agricultural ventilation fan for the

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Fan Selection. and Energy Savings

EZEE-DRY I 1 Tel Toll Free Outside Nebraska Toll Free Inside Nebraska I

mixed flow dryer one of the most efficient dryers on the market. Now CSA approved for Canada in 16, and 24' models.

Mixed Flow Dryer. One of the most efficient dryers on the market.

B-1151 February Karen L. Panter, University of Wyoming Cooperative Extension Service Horticulture Specialist, Department of Plant Sciences

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan

Task Force. Rewarming Supercold Grain. Dirk E. Maier, Agricultural Engineering

The authors, William F. Wilcke and R. Vance Morey, are associate professor and extension engineer, and professor and head of the University of

Ducted Propeller. Airflow Volume

Minimize Shrink from Grain Drying and Aeration

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

KCC Centrifugal Fan Air Cooled Condensers

EC Sulfur for Alfalfa Production in Nebraska

Day after day, Season after season, Generation after generation.

How to Install an Attic Fan

www. ElectricalPartManuals. com INSTRUCTIONS DRY TYPE TRANSFORMERS OPERATION AND MAINTENANCE OF

1.. I.. I.. Large round balers. Bill Hires Charles Ellis Agricultural Engineering Department College of Agriculture

Competitor Series Dryers

Drying and Cooling Stored Grain and Preserving its Quality

Carrying on GSI s proud history of innovation in grain drying, the new X-Stream dryer features fans and heaters mounted in a staggered fashion on

Ultra Clean LAMBTON CONVEYOR LIMITED. Installation and Operation Manual ONE SOURCE ONE SOLUTION

CALDWELL HEATER INSTALLATION AND OPERATION MANUAL

QUALITY. Task Force. Shifting from Corn Drying to Corn Storage. Dirk E. Maier, Agricultural Engineering. Average Temperature F

CALDWELL HEATER INSTALLATION AND OPERATION MANUAL

Selecting the Correct Fan

Stulz CyberMOD EC Fan Retrofit Kit Switch & Save

EFFICIENT GRAIN DRYING + STORAGE TOPDRY GRAIN DRYER PROVEN & DEPENDABLE

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

The Advantages of Choosing Centrifugal Fans

GRAIN STORAGE AERATION PRESENTED BY: BRENT BLOEMENDAAL AERATION EXPERT

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION

EVALUATION OF SWINE FACILITIES VENTILATION

EC Guide to Kitchen Storage

PAVER BLOCK FIXING INSTRUCTIONS VYARA ROTATIONAL INTERLOCK

Energy Efficient Corn Drying. Kenneth Hellevang, Ph.D., P.E. Professor & Extension Engineer

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Direct Fired Heater Model AD Specification

Managing your Dryer And Shrink NGFA / Grain Journal Conference Aug 1 - Aug 2, Bob Marlow, The Andersons, Inc

Evaluation Report 509

Tower Dryers U Bu/Hr. QuadraTouch Controls Industrial Grade Components

CHOOSING A COOLING SYSTEM

Explosion Venting and Suppression of Bucket Elevator Legs, G90-990

RICE TECHNOLOGY Bulletin

Glossary of Terms Laboratory & Fume Exhaust Fans

Transcription:

University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Historical Materials from University of Nebraska- Lincoln Extension Extension 6-1949 EC736 Grain Drying with Forced Air Circulation E. A. Olson G. M. Petersen F. D. Yung Follow this and additional works at: http://digitalcommons.unl.edu/extensionhist Olson, E. A.; Petersen, G. M.; and Yung, F. D., "EC736 Grain Drying with Forced Air Circulation" (1949). Historical Materials from University of Nebraska-Lincoln Extension. 2262. http://digitalcommons.unl.edu/extensionhist/2262 This Article is brought to you for free and open access by the Extension at DigitalCommons@University of Nebraska - Lincoln. It has been accepted for inclusion in Historical Materials from University of Nebraska-Lincoln Extension by an authorized administrator of DigitalCommons@University of Nebraska - Lincoln.

. 736 JUNE 19 49 W ITH RYING R CIRCULATION., COOPERATIVE EXTENSION WORK IN AGRICULTURE AND HOME ECONOMICS UNIVERSITY OF NEBRASKA COLLEGE OF AGRICULTURE, AND THE UNITED STATES DEPARTMENT OF AGRICULTURE COOPERATING, H. G. GOULD, ASSOCIATE DIRECTOR, LINCOLN.

-2- LAY IN PLACE, REMOVE FOR CLEAN-UP AIR INLET OT LE::iS THAN I SQ. FT. OPENING FOR EACH 100 SO. FT. BIN FLOOR. FIG. No. 2 LATERAL DUCT SYSTEM FOR GRAIN DRYING Nebraska. temperatures and humidity are favorable for drying at harvest time. The use of heated air may present a fire hazard, increase the investment in equipment, and may increase the cost of drying, but may be very important unuer adverse weather conditions in making possible the saving of a crop. SAFE MOISTURE CONTENT FOR STORAGE OF OTHER GRAINS The moisture cont ent for safe storage of shelled corn over long periods of time is 12-13 ~er cent, and for sorghum 13 per cent. At the present time, no definite figures can be gi ven for oats and barley. FIG. No. 3 CANVAS SLEEVE USED TO MAKE MAIN AIR DUCT

ADAPTING BINS FOR FORCED AIR CIRCUlATION -3- I n drying with forced air circulation, arrangements must be made to secure uniform air flow through the grain for satisfactory results. One method of doing this is to install a perforated floor as shown in Figure 1. This perf.orated floor must be placed above the bin floor and supported to allow free air passage to all parts of the air chamber below the grain. Information on new storage structures adapted for drying is available from County Extension Agents. The lateral duct system shown in Figure 2 can also be used for adapting bins for forced air circulation. The main duct can also be built on the outside of the bin and used in drying successive bins of the same size. Waterproof canvas serves as a simple means for forming an outside duct as shown in Figure 3. When the duct system is used in bins wider than 12 feet, the main duct should be placed in the center of the bin floor as shown in Figure 4. Metal perforated flooring is excellent for use in bins with raised floors. (See Figure 5). The total area of the perforations should be at least 7 to 10 per cent of the floor area. Information on obtaining such flooring can be secured from the County Agents' office. Floors can be constructed of such materials as landing mat, hardware cloth, or other wire mesh, properly supported and covered with fly-screen wire. The practical limits on grain depths for forced air drying are about 8 to 10 feet. For satisfactory drying, the grain should be evenly distributed at a uniform depth in the bin. During the filling process, the grain should be leveled fre~uently to reduce packing under the elevator or blower spout and to prevent the accumul ation of chaff or cracked grain in one part of the bin. FOR BIN UP TO 12' WIDE, USE MAIN DUCT AT SIDE OF BIN. FOR BINS OVER 12' WIDE, USE MAIN DUCT THROUGH CENTER OF BIN. FIG. No. 4 PLAN VIEW OF LATE~AL DUCT SYSTEM

-4- Figure 5 One t ype of' perforated floor used in a steel bin in exper i mental drying work by t he Department of Agricultural Engineering at the Nebraska Agricultural Experiment Stat i on. FANS OR BLOWERS Two types of f ans have been used for grain drying; the propeller, taxial flow) and the centrif ugal. Fans will range in cost f r om about $175 t o $250 without the motor. The propell er fans (See Figure 6) have curved blades similar in shape to those of an airplane propeller, mounted on a small hub, and range i n diameter from 24 to 60 inches. This t ype of f an is light in weight, compact, and requir es little space for installation. It is a high speed fan and can be obtai ned wit h pulley drives or for direct connect ion t o electri c motors. Because of its high speed, it emits a t ypical airplane propeller noise. Apparently this noise is not objectionable as many fans of this tn>e have been used on drying installat ions. The power requirement s of the pr opeller fan vary only slightly wit h changing stati c pressures. This character ist ic t ends t o make this fan particularly well sui t ed for grain drying on the farm. In the interest of safety, a shield should be installed t o prevent the operator from getting a hand, arm, or clothing caught i n the f ast moving b J~ des. This shield, which can be purchased from f an manufa ct urers, will also protect t he fan from injury t hat might be caused by rocks and sticks thrown by youngsters. The centrifugal fans or blowers (See Figure 7) are divided i nto t hree classes according to the shape of t ho blades : l. Straight r adial blade f ans. 2. Forward cun ed blade fans with blades curved forward in the d:t rection of r otation. 3. Backward curved blade rect i on of rotation. f ans curved backward opposite to the di

-5- Of the centrifugal fans, the backward curved t ype will be most satisfactory for grain drying. Power characteristics of the backward curved fans are not as favorable as those of the propeller type under conditions of varying static pressures. When static pressures are reduced, the power requirements will tend to increase and may cause overloading of the power unit. The major disadvantages of this fan are its wei ght, size, and cost. At present, almost all fans of thir type are especially designed for high efficiencies and quiet, continuous operation. Where electric power is avai lable, an electric motor will be the most convenient source of power for forced air circulation. Where electric power is not available,- gasoline engine power units can be used. When a gasoline power unit is used, the engine may be shrouded so that i ngoi ng air is circulated past the engine before going through the fan. The heat thus gained from the engine will cause some increase in drying rate. If the engine is shrouded, exhaust gasses should be discharged outside the shroud, not permitted to pass through the grain. Figure 6 A typical propeller type f an belted to an electric motor. FAN CAPACITY REQUIRED Fan requirements will vary with the size of grain bin and the depth of grain involved. A r ule of thumb method of figuring t he fan capacity is to allow an air flow of one cubic foot per minute (c.f.m.) for each square foot of bin floor area and for each foot of depth of clean grain. The static pressure (back pressure) against which the fan must operate to produce this air f low increases as the depth of the grain increases.

-6- Static pressure is commonly measured at a small hole in the wall of the duct through which the air is flowing. The pressure is usually expressed in terms of the height of the water column which could be supported by this pressure. The following table shows static pressures which might be expected for different depths of various grains. The figures given are for clean grain. Under field conditions, the grain may contain chaff and cracked kernels which may increase the pressures to as much as twice the figures shown. STATIC PRESSURES REQUIRED TO FORCE AIR THROUGH CLF.AN GRAINS AT VARIOUS DEPTEB (Based on air flow of 1 c.f.m. per square foot for each foot of depth) Grain Depths of Grain 4 Feet 6 Feet 8 Feet 10 Feet Barley 0.15 0.35 o.65* 1.0* Corn (Shelled) 0.055 0.18 0.4 0.8* Oats 0.19 0.45 0.85 1.4* Sorghmn 0.2 0.47 0.9* 1.5* Wheat 0.42 1.0 1.5* 2.5* *These figures are approximations made by extrapolation beyond available data. To determine the fan capacity for a bin.20 feet by 20 feet filled with 8 feet of wheat, the following method is used. First figure the bin area. Bin area = 20 1 x 20 1 = 4oo square feet Multiply the bin area by depth of grain 400 x 8 = 3200 which gives the fan capacity required in cubic feet per minute. As shown in the table above, the static, ~ressure for an 8 foot depth of clean wheat will be 1.5 inches. In actual practice, this may range up to 2.5 inches, depending on the amount of foreign material present. Therefore, a fan will be needed which can deliver 3,200 c.f.m. of air against pressures up to 2.5 inches of water. The power required would be about 3 horsepower for a propeller type fan. POWER REQUIREMENTS Power requirements vary from 2 to 7i horsepower depending upon the type of fan, rate of air flow, and resistance pressures (static pressure). Requirements for any particular installation can be determined from information furnished to the local dealer by the manufacturer. When electric power will be used, the power supplier should be consulted regarding the maximmn size motor which can be used. This will vary in different areas from 5 to 7i horsepower. BIN OPENING FOR INTRODUCING AIR At least li square feet of area should be provided at the air inlet to the bin for each 1,000 bushels of grain stored. The bin used in the example above (20 1 x 20 1 x 8 1 ) with a capacity of 2,500 bu8hels should have an air inlet opening with about 4 square feet of area. The air outlet from the bin should have a t least double the area provided for the inlet. A flexible air duct made f r om waterproof canvas is generally used for connecting the fan outlet and the air

-7- inlet to the bin. dealers. (See cover). These ducts can be provided or "made-up" by local Air temperature affects the rate of drying -- faster drying at higher temperatures -- but the final moisture content of dried grain is determined by the relative humidity of the air, not the temperature. Tes t s have shown that grain exposed to air of 75 per cent relative humidity will dry only to about 14.5 per cent moisture; when relative humidity of air is about 50 per cent, grain will dry to 12 per cent moisture. Therefore, final drying must be done when relat ive humidity is below 50 per cent. Since relative humidity is such an important factor, a humidity indicator is essential. Instruments of sufficient accuracy are qui t e inexpensive and may be obtained for about the same price as a good thermometer. Figure 7 A centri fugal blower which can be used for forced air circulation. OPERATION OF FAN The fan should be started as soon as the grain can be spread over t he bin floor to a uniform depth. Operation of the fan should be continued unt il the top layer of grain has reached a safe moisture content. The moisture can be determined by taking a grain sample to the local elevator. It is good practi ce to finish drying with as cool dry air as possible, perhaps by operating at night if the air is cool and dry. Then, if the bin is closed while the grain is cool and at a low moisture content, the grain will remain cool and dry for periods up to several months, assuming that the bin is in good repair with a tight roof and sidewalls.

-8- It is a good precautionary measure after the grain has been in storage several weeks to take advantage of a cool dry period to force air through the grain to further dry and cool it. This should not be done unless the r el ative humidity is below 50 per cent and the air temperature below that of t he grai n. This may be done to advantage several times during the year - TJME AND COST OF DRYING The time required for drying may vary from one or two days up t o two weeks. This will depend on weather conditions and also on the amount of moisture to be removed. Power costs f or drying will depend largely upon the length of drying time. The cost may range from below one cent up to five cents per bushel. DRYING BY SHIFTING GRAIN Moving and turning wheat by means of portable farm elevators or by shoveling is of little value in reducing the average wheat moisture content. Such a practice is not reconnnended as a means of preventing "sick" wheat. It is doubtful if wheat could be dried to 12 per cent moisture by this method, and if it were possible, the handling charges might be prohibitively high. Some benefit may be derived from mixing damp wheat with dry wheat, if this is done before heati ng occurs. GRAIN STORAGES Once grain has been dried to a safe moisture content for storage, it is essential that it be kept dry. This requires a bin with a good floor, to prevent the grain from absorbing ground mnisture, and also a tight roof and sidewalls. During long periods of high humidity, grain that is stored in bins with single thickness walls or damp floors may have a tendency to gain in moisture. Bins constructed of double walls and with dry floors will tend to reduce this problem. Outside walls of storage bins should be painted with white, aluminum, or other heat-reflecting paint to reduce absorption of heat from the sun. The resultant lower storage temperatures wil: help eliminate deterioration of the grain in storage. Plans for the construction of new storages (types approved by Production and Marketing Administration for government loan) ere available through County Extension Agents, and also through many lumber dealers. Several of these plans show adaptations for drying.

SUMMA.RY The following steps are suggested for forced air grain drying: 1. Before harvest, check conditions of bins for storage -- make necessary repairs. 2. Determine type of drying system adapted to local needs -- raised perforated floor or lateral duct. Are needed materials available? 3. Figure fan requirements --Allow 1 c.f.m. of air for each square foot of bin area and for each foot of grain depth. Select a fan large enough to allow some reserve capacity. It may be necessary to place orders several weeks in advance or needs to allow for delivery. 4. Determine amount of power needed -- What type is available -- tractor or electric motor? If the latter is used, determine local power supplier's limitations on motor size. 5. If weather conditions are favorable, start drying bperation as soon as bin has been filled to a uniform depth. Continue until moisture in top layer of grain is low enough for safe storage. In the ~ase of wheat, drying should be completed within 30 to 45 days after harvest. 6. Close bin openings to prevent grain "picking up" moisture from the air after drying operation has been completed. 7- Check moisture damp weather. ing moisture. content of grain if it is stored through extended periods of Further forced air circulation may be needed if grain is gain-