TECHNICAL SPECIFICATION

Similar documents
GUJARAT NARMADA VALLEY FERTILIZERS & CHEMICALS LTD MTA PAC PROJECT ANNEXURE 6.4 SECTION 10 SPECS FOR AIR CONDITIONING

VOLUME 2 (BOQ & Price Bid)

TENDER DOCUMENT. NIT No: DLI/C&E/WI-721/271 FOR

Centeral Station Air Handling Unit

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

GUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

DIVISION 15 MECHANICAL

SECTION AIR DUCT ACCESSORIES

SECTION COOLING TOWERS

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

A. Codes and Standards that are Standard at the University:

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

TR CASSETTE AC 1 NOS TR CASSETTE AC 1 NOS. Rate in words : TR HIGH WALL (3 star rated) 2 NOS.

VOLUME 3 (Technical Specifications as Annexure-A & Drawing)

Direct Fired Heater Model AD Specification

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

SECTION COOLING TOWERS

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

Annexure-I Purchase Table-1 (R.O. Water Purifier Units and Chiller Units)

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Technology for life. Unit heater LH

Advance Release September 2009

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

SECTION COMPUTER ROOM AIR CONDITIONING SYSTEMS

Indian National Trust for Art and Cultural Heritage (INTACH, 71, KK Birla Lane, Lodhi Estate, New Delhi , Ph. No.

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit)

SBI INFRA MANAGEMENT SOLUTIONS PVT.LTD. HEAD OFFICE-GROUND FLOOR RAHEJA CHAMBERS, FREE PRESS JOURNAL MARG, NARIMAN POINT, MUMBAI-21

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Modular Supply Make-Up Air Unit

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION

SECTION AIR COOLED WATER CHILLERS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

SECTION AIR HANDLING UNIT

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

SECTION AIR OUTLETS AND INLETS

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

SECTION STEAM CONDENSATE PUMPS

SECTION CONVECTION HEATING AND COOLING UNITS

EHH SERIES DRAW THROUGH FAN COILS CFM

BOQ FOR FIRE HYDRANT & FIRE ALARM SYSTEM AT T.I.E

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.

dualarm Vertical In-Line Pumps

Contents INDEX. TDM Series Indirect Fired Heaters

Nairobi Funeral Home and Forensics VENTILATION AND AIR CONDITIONING BILLS OF QUANTITIES

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

SECTION WATER-SOURCE UNITARY HEAT PUMPS

DOCUMENT TABLE OF CONTENTS

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

.2 Section Waste Management and Disposal.

SECTION (15820) - AIR DUCT ACCESSORIES

AIR HANDLER SPECIFICATION

Evaporator EM-1. Features. V.1. Ceiling Mount Evaporators


AIR DUCT ACCESSORIES

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

SECTION HEATING BOILERS

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

1.1 This section applies to air handling units for HVAC Systems.

CENTRAL SPLIT UNIT UNIC


DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Transcription:

TENDER DOCUMENT NIT No.: DLI/C&E/WI-675/290 FOR Tender for Design, Engineering, Supply, installation, testing and commissioning of PACKAGE AIR CONDITIONING (PAC) SYSTEM AND ASSOCIATED WORKS for the project of Augmentation of Fuel and Flux crushing facilities (Package- 064) of Bhilai Steel Plant, (SAIL). VOLUME 2B TECHNICAL SPECIFICATION ENGINEERING PROJECTS (INDIA) LIMITED (A GOVT. OF INDIA ENTERPRISE) Core-3, Scope Complex, 7, Institutional Area, Lodhi Road, New Delhi-110003 TEL NO: 011-24361666 FAX NO. 011-24363426

4.0 AIR CONDITIONING SYSTEMS 4.1 Scope of work The air conditioning systems shall be provided in LT Substation LTSS-2 and LTSS-3 as per Annexure-I Contractor shall furnish schedule & brief specification of air conditioning/ ventilation system with the offer. 4.2 Design Criteria for Air Conditioning and Ventilation Systems The ambient atmospheric conditions are as follows SEASON TEMPERATURE (DBT) SUMMER 45 26 MONSOON 33 70 0 C WINTER 10 - RELATIVE (%) HUMIDITY The different air conditioned rooms shall be maintained at 23+2 0 C and 55+5 % RH. AC plant room shall be provided adjacent to the served premises. All fasteners shall be hot dip galvanized unless stated otherwise. Noise level of equipment shall be limited to 85 db(a) at 1 m distance from the equipment unless stated otherwise elsewhere. Noise level inside the air conditioned & ventilated premises shall be limited to 65 db(a). Motor rating shall be minimum 20% more than the BKW Fusible link type fire damper will be provided at supply air duct for all served electrical premises, cable basement & other susceptible fire hazard premises. Cooling load calculations (as per CARRIER HANDBOOK GUIDELINES) and system capacity & configuration shall be submitted by contractor before submitting any detail engineering drawing. 4.3 System Description 01 AIR CONDITIONING FACILITIES Type of air conditioning system to be provided as per the following guide lines Sl. No. (i) Type of Air Conditioning System Split air conditioner/ ductable split air conditioner (ii) Water cooled package air conditioners (with minimum 1 no. standby) Premises Office premises with cooling load less than 5 TR (with minimum 1 no. standby). Control rooms/ dispatcher rooms, intelligent MCC rooms, VVVF panels area in MCC room

Air Conditioning System with Water Cooled Package Air Conditioners : Air conditioning system shall include water cooled package air conditioners with starter panel (starting control), microprocessor based control panel (safety & operating controls) & sensors. The air conditioning system shall include condenser water pumps, induced draft FRP cooling tower, make up water tank for cooling tower (minimum 16 hrs water holding capacity), condenser water piping, G.I ducting, air supply grills/ diffusers, thermal insulation of ducts ( for ducts passing through the non air conditioned area & tail end of long ducts in air conditioned area), acoustic insulation of ducts (up to 5 to 7m length) at outlet of package air conditioners, under deck insulation of all exposed roofs in air conditioned premises, MCC/ starter panels, necessary electrics, instrumentation etc. Cooling tower shall be installed at the highest point of condenser water circuit. Make up water tank (5 mm thick & internal surface epoxy painted) shall be provided at higher elevation than the cooling tower basin. Pressure gauge & temperature gauge shall be provided at inlet & outlet water line of condenser. Pressure gauge at pump inlet & outlet shall be provided. Differential pressure switch shall be provided at package A.C inlet & outlet water line & interlocked with compressor. Minimum 1 no. standby package air conditioner & 1w+1s condenser water pumps shall be provided. R-22/ R134a refrigerant shall be used. Refrigerant compressor shall be either scroll or semi-hermetic reciprocating type. Chemical dosing system shall be provided at package air conditioner recirculation water 4.4 Equipment Specification 001 MONOBLOCK PUMP Mono block pump shall be provided for capacity 15 m3/hr & less. Pump shall conform to IS: 9079-1989. Pump casing will be of C.I & impeller will be of bronze & shall have stuffing box arrangement for gland packing. IP-55 protection motor shall be provided. 002 HORIZONTAL BACK PULL OUT PUMP: Horizontal back pull out pump shall be provided for capacity more than 15 m3/hr. 003 COOLING TOWER Type : Induced draft counter flow Casing/ Basin : FRP Frame Work : MS hot dip galvanized Fills : PVC Nozzles : Brass Bolts, nuts, miscellaneous hardware : MS electro galvanized Fan hub & blades : Cast Aluminium Fan type : Axial flow, direct drive

Fan speed : 720 rpm Degree of protection of motor : IP 55 (temperature rise limited to class B) Ladder : Galvanised steel ladder with safety cage & hand railing up to the top of tower. Inclined to 300 to the vertical Eliminators : No. of deflector to be arranged to reduce drift loss < 0.2% of water circulation. Cooling Tower Accessories: (i) Level switch at cooling tower basin (to be interlocked with pump) (ii) Make up connection with float valve (float made of copper) & back up ball valve (iii) Quick fill connection with ball valve (iv) Overflow connection (v) Drain connection with ball valve (vi) GI wire mesh 18 gauge strainer (vii) Equalizing line of cooling towers with isolation valves (viii) Note :- Approx. distance from Cooling tower to PAC unit shall be 20-25 mtrs. for the purpose of calculating pipe length. 004 PRE- FILTER BEFORE PACKAGE A/C UNIT Filtering media shall be of 5 ply HDPE mesh, stiched and pleated to provide maximum filtration area. Filter media shall be supported on either side by galvanised wire mesh. Suitable aluminium spacer shall be provided to segregate the folds to ensure uniform distribution of air flow through the filter. Filter frame shall be fabricated from 18 G GI sheet. Filter frame shall be provided with suitable handles. Filter frame shall be provided with neoprene sponge rubber.filters shall be capable of being cleaned by compressed air/ water flushing. Face velocity of air through filter shall be limited to 2.5 m/s. Efficiency of filter shall not be less than 90% for dust sizes down to 10 micron. 005 GI DUCTING The following codes & standard shall be followed IS : 226 Specification for structural steel (standard quality) IS : 655 Specification for metal air duct. IS : 277, 2003 Specification for galvanised steel sheets SMACNA Sheet Metal and Air Conditioning Contractors National Association The air distribution system shall be sized to have a constant frictional drop along its length. The maximum air velocity shall be restricted to 7.5 m/sec for air conditioning and 10 m/s for ventilation ducts. Ducts shall be supported by 10 mm MS Rods and 40x40x3 MS angles. The duct supports shall be at a distance of not more than 2500 mm. The MS rods shall be hung by dash fasteners fixed to the ceiling slab.

Flexible connection of at least 150 mm width shall be provided where the duct connects to the package AC, AHU, fan etc. Flexible connection shall be closely woven, rubber impregnated double layer canvas or neoprene coated fiber glass. 006 DIFFUSERS AND GRILLS Diffusers/grills shall be of extruded aluminium powder coated. All supply air diffusers/grills shall be complete with volume control dampers. Supply air grills/diffuser shall be double deflection type. Air volume control damper shall be operated by a key from the front of grills/diffusers. Thickness of Grills, Diffuser, Damper shall be as follows: (a) Frame 16 gauge (b) Louvers 18 gauge Suitable vanes shall be provided in duct collar to have uniform/proper air distribution. Bank of baffles wherever required shall also be provided. Air velocity through diffusers & grills shall not exceed 2 m/sec (for A/C system) and 4 m/sec (for ventilation system). 007 INSULATION The surface to be insulated both thermally and acoustically shall be thoroughly cleaned. Pressure/Hydrostatic tests shall be carried out before application of insulation. Sl. No. (i) Two coats of primer paint shall be applied on the clean surface and then CPRX Compound (Shalimar Tar products or equivalent) shall be uniformly applied @ 1.5 kg/sqm on the surface to be insulated. Thereafter insulation shall be fixed. Vapour barrier shall be applied over the insulation followed by 24 G Al cladding or sand cement plaster in 2 layers, totaling 12.5 mm Insulation Material Specification Resin bonded glass wool : Density 48 Kg/m3, IS :8183 PUF : Density 35 + 3 Kg/m3, IS: 12436 Type of Insulation Surface Insulation Material material Acoustic Resin insulation glass wool (ii) Under deck thermal insulation (iii) Duct thermal insulation bonded Insulation Thickness Finish (mm) Slab 12 Fiber glass tissue & perforated Al sheet PUF Slab 50 22 GI sheet cladding PUF Slab 25 (tail end ducting) 40 (exposed ducting) 26 G Al cladding

008 TEMPERATURE GAUGE Type : Bi-Metal thermometer Rigid Stem Accuracy : + 1% of FSD Stem of connection metals: AISI 316SS Immersion length: To suit pipe size Enclosure : Cast Al stove enamelled black with weather proof as per IP65 Dial Size : 100 mm Sensor : Bi-Metal strip Stem dia : 8 mm Connection : ½ BSP (m) Mounting : Vertical Entry : Bottom Range : 0-60 0 C Thermo well : To be provided

ANNEXURE-I TENTATIVE PACKAGE AIR CONDITIONING (PAC) AREA DETAILS Sr. no. 1 Area Description LT Substation LTSS-2 Size (LxWxH) in mtr. (APPROX.) Quantity of PAC (No.) 2 a IMCC,UPS and RIO area at First Floor 17.09x6.50x3.66 b Occupancy in above area 3 persons c Equipment Heat load for A/c purpose i UPS load 1 kw ii RIO load for 3 nos. (4kW for each) 12 kw iii IMCC-2 load 15 kw d Fresh Air Change per Hour to be considered 1.5 FACH LT Substation LTSS-3 A FIRST FLOOR a IMCC and UPS area at First Floor 19.25x7.00x3.66 b Occupancy in above area 3 persons 1 Set c Equipment Heat load for A/c purpose i UPS load 3 kw ii IMCC-3A load 8.8 kw iii IMCC-3B load 8.8 kw d B Fresh Air Change per Hour to be considered PLC ROOM AT SECOND FLOOR 1.5 FACH a Server and RIO area at Second floor 9.50x4.25x3.66 b Occupancy in above area 3 c Equipment Heat load for A/c purpose i Processor Panel load for 2 nos. (2 kw for each) 4 kw ii RIO load for 3 nos. (4kW for each) 12 kw iii Server 1 no. 4 kw iv CCTV Panel 4 kw v Computers -8 Nos. (0.2kW for each) 1.6 kw d Fresh Air Change per Hour to be considered 1.5 FACH C OPERATOR CABIN AT SECOND FLOOR a Area 8.00x4.25x3.66 b Occupancy in above area 6 persons c Equipment Heat load for A/c purpose i UPS load 1 kw ii Computers -8 Nos. (0.2kW for each) 1.6 kw d Fresh Air Change per Hour to be considered 1.5 FACH 1 Set

Enquiry Specification for PAC Package DATA SHEETS

Enquiry Specification for PAC Package 1.0 TECHNICAL DATA SHEETS (To be filled by the vendor) 1.1 PACKAGE AIR CONDITIONER (PAC) 1. Make & Model : 2. Quantity : 3. Capacity in TR : 4. Overall dimension of Package AC Unit : 5. Air flow capacity of blower m3/h : 6. Total Pressure, mm WC : 7. Fan Motor kw : 8. Fan RPM : 9. Compressor type, model : 10. Compressor motor kw : 11. Refrigerant type : 12. Condenser type : 13. Condenser material of construction : 14. Overall size of condenser : 15. Material of construction and its thickness of casing : 16. Insulating material of casing : 17. Total Power consumption. : 18. Noise level at 1m distance in db(a) : 19. Vibration isolation pad : 20. Performance curve : 21. Fixing details : 22. Refrigerant drier and strainer :

Enquiry Specification for PAC Package 1.2 COOLING TOWER FOR PAC 1. Make & Model : 2. Type : 3. Quantity : 4. Overall size of cooling tower : 5. Capacity of cooling in TR. : 6. Water flow m3/h : 7. Air flow : 8. Design water inlet temperature, : outlet temperature 9. Material of construction and : its thickness 10. Speed in rpm : 11.Drive details : 12.Shaft Power consumption : 13.Wheel diameter : 14.Efficiency : 15.Size of fan : 16.Static & Dynamic weight of fan : & motor assembly 17.Bare weight and operating : weight of cooling tower 18.Noise level at 1m distance in db(a) : 19.Fixing details : 20.Vibration level : 21.Water spray nozzle type : 1.3 RE-CIRCULATING WATER PUMPS 1. Pump capacity & head, motor KW : 2. Re-circulating piping & fitting, Make : 3. Strainer & valve, Make : 4. Instruments pressure gauge, : temperature gauge, water flow switch, manometer

Enquiry Specification for PAC Package 1.4 DUCTING NETWORK FOR PAC SYSTEM a) Ducting 1. m 2 of duct work : 2. Weight of duct work : 3. Weight of support and flanges : 4. Material and thickness of duct work : 5. Duct support type and material : 6. Velocity of air : b) Supply Air Grills (Adjustable louver grills)/diffuser with volume control facility 1. Size : 2. Quantity offered : 3. Material of construction & thickness: 4. Provision of horizontal & vertical : direction control 5. Weight : 6. Velocity of air : 7. Methods of volume control : e) Return air grills/intake air louvers 1. Size : 2. Quantity offered : 3. Material of construction : 4. Weight : 5. Velocity of air :

Enquiry Specification for PAC Package 1.5 WATER LINE VALVES 1. Make & Model : 2. Type : 3. Quantity : 4. Size : 5. Pressure rating : 6. Material of construction : 7. Operating system : 8. Drive details : 9. Gland packing : 10. End connections : 11. Service : 12. Test pressure :