A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

Single zone RTU, controlled by a programmable thermostat. Single zone RTU, generic description, with power exhauster

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

4. OVERVIEW OF MECHANICAL SYSTEM

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Verasys System Operation Overview Technical Bulletin

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

SECTION SEQUENCE OF OPERATIONS FOR BUILDING CONTROLS

Your Home. Jacco & Assoc.

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

COMcheck Software Version Mechanical Compliance Certificate

COMcheck Software Version Review Mechanical Compliance Certificate

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Digital Precise Air Control - DPAC

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Selected Laboratory Energy Efficiency Measures

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Virginia Tech Standards for Building Automation System

Appendix 13. Categories of Cooling and Heating systems

1.0 Digital Controller

Your Home. Jacco & Assoc. Fan on with call for heating or cooling Heating on with call from space thermostat Stage as

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

COMcheck Software Version Mechanical Compliance Certificate

ASHRAE JOURNAL ON REHEAT

OSU Alumni Center Phase I Implementation Review. Oregon State University 130 Oak Creek Bldg. Corvallis, Oregon

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP 100% OUTSIDE AIR

SESSION Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE ( ) ASHRAE Detroit Members:

November 11, City of Sparks 215 S. 21 st St. Sparks, NV

MicroTech Rooftop/RMC

TEC Controller VAV 0-10V Fan Control with Hot Water Heat, Application Application Note Building Technologies

Reference Guide for Microprocessor Controller

COMcheck Software Version Mechanical Compliance Certificate

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

Ramp It Up VAV Ramps and Controller Possiblities

AirTrak. Digital Control System. User Manual. Touchscreen Systems

Mechanical Compliance Certificate

Zone. In the. Contractors and technicians may often find themselves. In today s wired world, zoning has evolved from wired to wireless.

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

HVAC Mandatory Provisions Part II, Page 1

York 25-Ton VAV Rooftop Unit

COMcheck Software Version Mechanical Compliance Certificate

Inspection Phase Three. Mechanical, Electrical & Plumbing Section 503

Submitted to. Texas A&M University at Galveston The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

MicroTech Unit Ventilator

Submitted to. Texas A&M University-Corpus Christi The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

MicroTech Self-Contained Air Conditioning System

Reference Guide for Microprocessor Controller

Zoning System Design Manual

EADQUARTERS. Technical Report One. Stephanie Kunkel Mechanical Option

HVAC 101. H V A C S y s t e m s

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

Mechanical Technical Report 1. ASHRAE Standard 62.1 Ventilation Compliance Evaluation

COMcheck Software Version Mechanical Compliance Certificate

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

DX-9100 Applications from Engineering Services

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Engineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.

terminal unit accessories

COMcheck Software Version Mechanical Compliance Certificate

I N STALL AT ION & O PERATIO N MANUAL TA 1/ TA 2 CONTROLLER. Redefine your comfort zone.

UNT Applications. Using UNT Applications...3. Introduction Key Concepts UNT Controller Applications Fan Coil Units...

Dehumidifying with Dedicated Outdoor Air

American University Design Standards

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP RECIRCULATION AIR WITH ECONOMIZER

COMcheck Software Version Interior Lighting Compliance Certificate

HVAC Controls Upgrades: Requirement Details ( )

Zoned Rooftop Systems. Light commercial packaged rooftop systems from Trane

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

Challenges and Methods of Estimating a Conceptual HVAC Design

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

Siemens Thermostats. RDY2000BN Thermostat

I/O ZONE 560/583 USERS GUIDE

Direct Gas-Fired Make-Up Air Models DG and DGX

ADDENDUM No: 3 JOSEPHINE COUNTY BUILDING OPERATIONS DEPARTMENT. February 29, NO CHANGE: March 8, 2012 / NOT LATER THAN 2:00 PM

T7300F Multistage Conventional or Heat Pump Programmable Commercial Thermostat

HVAC Controls Upgrades: Requirement Details ( )

1 - This title will copy onto other forms Date

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

TC-9102 Applications

Document # R01

Feature Summary. I. System

COMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units

Technical Assignment 3 11/15/04. Executive Summary

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

COMMERCIAL HVAC PACKAGED EQUIPMENT. Split Systems

BACnet PTEC Controller VAV 0 to 10V Series Fan and 3- Stage Electric Heat, Application 6657

HEAT TROL ELITE SERIES HWE-Single Stage, HWE-MOV, HWE-Mulit Stage Hot Water Reset Control for Light Commercial and Residential Applications Provides q

Andrea Borowski The Pennsylvania State University University Park, PA November 11, 2002 Consultant: Dr. Bahnfleth Technical Assignment M-3

CHAPTER 4. HVAC DELIVERY SYSTEMS

Transcription:

Job Name Control Systems Description Date Project Overview The project is a describe the building and its major HVAC systems (e.g. three-story office building, served by a rooftop unit VAV system ). In the second paragraph (as required), discuss various other equipment that make up the facility s HVAC systems. Other miscellaneous unitary equipment round out the building s HVAC requirements, as will be discussed herein. Control Systems Overview The major systems and equipment on this project will be monitored and controlled via a networked Direct Digital Control (DDC) system. The systems and equipment to be monitored and controlled by the DDC system include the following: The DDC system is to allow for the proper control of all equipment as listed above and described herein. Access to control parameters is either via an on-site front end (PC or laptop), or via a remote station through a dial up connection. Setpoint programming, time-of-day scheduling, night setback, unoccupied period overrides, and whatever other control schemes may apply, can all be performed through the computer interface running the appropriate software. Monitoring of critical points and alarming of failures and system malfunctions will also be provided via the interface. The DDC system will be programmed and configured to operate the various HVAC systems and equipment in accordance with the Description of Control (included herein). A complete Sequence of Operation will be developed for the project as it is required, describing in detail the various systems and operational attributes. Given the nature of the project, the Sequence of Operation may be revised throughout the course of the project. The DDC system will accommodate the appropriate input and output points, so as to ensure that the system has enough flexibility to allow for potential revisions to the Sequence of Operation. The final version of the Sequence will be included on the as built set of the control drawings. All required DDC controllers, as well as all required sensors, transmitters, relays, damper actuators, control valves, etc., will be provided so as to ensure a complete, functional control system. Packaged equipment with factory wired control systems will have limited control from the DDC system. For these types of equipment, this is typically limited to enable/disable and point monitoring, unless otherwise indicated. For equipment having the capability of accepting a setpoint signal from a digital controller, this point may be provided. For equipment capable of offering monitoring and/or alarm output points, these may be utilized as inputs to the DDC system. All required engineering, support, programming, and system commissioning will be provided. This will include a complete set of wiring diagrams and control drawings, for use by the installing electricians. Mounting of all controllers, sensors, relays, etc. will be performed by the mechanical contractor s electricians. All control wiring associated with the DDC system will be performed by the mechanical contractor s electricians as well. This includes providing the DDC controllers with control power, wiring of DDC controllers to equipment terminal strips and starters, wiring of sensors and relays, communication wiring, etc. Power wiring will be performed by others, and includes mounting and three-phase wiring of starters and disconnects, and power wiring to three-phase and single-phase equipment. This project also consists of HVAC equipment not controlled by the DDC system. The equipment not controlled by the DDC system includes the following:

[NON-DDC OVERVIEW] The HVAC control systems for this project are non-ddc in nature, and thus there will be no control system network and no centrally located user interface. The various equipment making up the HVAC systems are standalone, meaning that they will operate via local controls, with no support from a higher tier supervisory control system. The individual control systems serving the various equipment may be simple electric, electronic, or even microprocessor-based, depending upon the equipment, its application, and the factory offering with regards to packaged controls and controllers. Interface to operating parameters will be described herein, and will take the form of local thermostats or zone temperature controllers, or equipment mounted operator interface panels. Establishment of setpoints, occupancy schedules, override periods, and other important operating parameters will be done via these local level controls and controllers. Description of Control For each piece of equipment, a description of how it will be controlled is included here. These descriptions will not necessarily explain in full detail the sequence of control for each part, but instead will define in general how each piece of equipment is to operate. Air Handling Units AHU-1 & AHU-2 Rooftop Units (Pick one of the following two short descriptions for single zone CV RTUs, or find a more appropriate description to customize) RTU-1 Packaged rooftop unit RTU-1 serves the elevator machine room, and is controlled by a non-programmable thermostat located in the space served. RTU-2 A programmable thermostat is located in the space served. Time-of-day scheduling is set via this device, as well as occupied and unoccupied space temperature setpoints. During occupied modes, the supply fan runs continuously, and the thermostat operates the rooftop unit to maintain space heating and cooling temperature setpoints (of 72 and 74 degrees, adj.). During unoccupied modes, supply fan operation is intermittent, and the thermostat operates the rooftop unit to maintain the space temperature between unoccupied setpoints (of 60 degrees heating and 80 degrees cooling, adj.). Make Up Air Units MAU-1 Fan Coil Units FCU-1 though FCU-10 (Pick one of the following three paragraphs, or find a more appropriate description to customize)

Split system fan coil units have a DX coil, an electric heating coil, and a hot water coil. Each unit is set up to bring in a minimal fixed amount of outside air. The units are controlled by non-programmable thermostats, as staged cooling and staged heating. A freezestat mounted to the leaving side of each unit s hot water coil shuts down the unit if air temperatures across the coil become too low. Four-pipe fan coil units, each consisting of a fan, a hot water coil, and a chilled water coil, condition their respective spaces by recirculating air and heating or cooling it as required in order to maintain space temperature setpoints. The units are controlled by integral, unit mounted thermostats. Two-pipe fan coil units serve the living spaces, and are controlled via integral thermostats. Automatic changeover occurs between heating and cooling seasons, via local aquastats that sense the temperature of the water feeding each unit, and determine which mode (heating or cooling) is allowable. Cooling is not possible when there is hot water feeding the coils of the units. However, heating is possible when there is chilled water feeding the coils, as each fan coil unit is equipped with an electric strip heater. VVT System Overall System Control Rooftop unit mode (heating, cooling, or ventilation) is determined by the needs of the individual zones. For instance, if more zones are in need of cooling rather than heating, then the rooftop unit will operate in a cooling mode. Conversely, if more zones are in need of heating rather than cooling, then the rooftop unit will operate in a heating mode. If there is no heating or cooling demand by any of the zones, then rooftop unit heating and cooling are disengaged, and the supply fan continues to run (ventilation mode). Individual Zone Control Once the mode of operation is established, then the zone dampers for those zones that are in need of the current mode (cooling or heating) will modulate, or periodically adjust position, in order to maintain the desired zone temperature setpoints. The zone dampers for those zones that aren t in need of the current mode will drive fully closed or to their minimum positions. As setpoints are reached and consequently zone dampers close off, the system bypass damper will modulate open in order to maintain airflow through the rooftop unit, and also to prevent excessive pressure buildup in the ductwork. Terminal Units (Use only what the particular project consists of, and delete the rest of the descriptions) Cooling-only VAV Boxes VAV box controller. The controller in turn modulates the primary air damper in order to deliver the appropriate amount of cool air from the medium pressure duct into the zone. As the zone temperature falls toward setpoint, the damper is modulated closed toward its minimum position. When the zone temperature reaches setpoint, the damper reaches its minimum position. setback and morning warmup heating cycles. VAV Boxes with Electric Reheat

VAV box controller. The controller in turn modulates the primary air damper in order to deliver the appropriate amount of cool air from the medium pressure duct into the zone. As the zone temperature falls toward setpoint, the damper is modulated closed toward its minimum position. When the zone temperature reaches setpoint, the damper reaches its minimum position. If the temperature in the zone continues to fall, then the primary air damper opens to an intermediate heating position, and electric heat is staged. The further the temperature falls from zone setpoint, the more stages of heat are engaged. setback and morning warmup heating cycles. VAV box electric heat is disabled. VAV Boxes with Hot Water Reheat VAV box controller. The controller in turn modulates the primary air damper in order to deliver the appropriate amount of cool air from the medium pressure duct into the zone. As the zone temperature falls toward setpoint, the damper is modulated closed toward its minimum position. When the zone temperature reaches setpoint, the damper reaches its minimum position. If the temperature in the zone continues to fall, then the primary air damper opens to an intermediate heating position, hot water heat is engaged, and the hot water valve is modulated. The further the temperature falls from zone setpoint, the more hot water is allowed to flow through the coil. setback and morning warmup heating cycles. VAV box hot water heat is disabled. Series Fan Powered Boxes with Heat fan powered box controller. The controller in turn modulates the primary air damper in order to allow the appropriate amount of cool air from the medium pressure duct into the box. The air is then blended with warm air circulated from the plenum by the fan, which is in continuous operation during the occupied mode. The resulting air delivered into the zone is of constant volume (as dictated by fan speed) and variable temperature. As the zone temperature falls toward setpoint, the damper is modulated closed toward its minimum position, allowing less and less cool air to be blended with the plenum air. When the zone temperature reaches setpoint, the damper reaches its minimum position. If the temperature in the zone continues to fall, then terminal unit [electric / hot water] heat is engaged. The further the temperature falls from zone setpoint, the more heat is engaged. The primary air damper is driven [fully open / fully closed] during main air handling unit shutdown modes. The fan and heat cycle to maintain a reduced zone temperature setpoint. During air handler night setback and morning warmup heating cycles, the primary air damper assumes its [fully open / minimum] position, and terminal unit heat is [disabled / controlled to occupied mode zone setpoint]. Parallel Fan Powered Boxes with Heat fan powered box controller. The controller in turn modulates the primary air damper in order to deliver the appropriate amount of cool air from the medium pressure duct into the zone. The air delivered into the zone is of variable volume and constant temperature. As the zone temperature falls toward setpoint, the damper is modulated closed toward its minimum position. When the zone temperature reaches setpoint, the damper reaches its minimum

position. If the temperature in the zone falls below setpoint, the fan energizes to circulate warm air from the plenum. The plenum air is blended with the minimal cool air from the primary air damper, and delivered to the zone. If the temperature in the zone continues to fall, then terminal unit [electric / hot water] heat is engaged. The further the temperature falls from zone setpoint, the more heat is engaged. The primary air damper is driven [fully open / fully closed] during main air handling unit shutdown modes. The fan and heat cycle to maintain a reduced zone temperature setpoint. During air handler night setback and morning warmup heating cycles, the primary air damper assumes its [fully open / minimum] position, and terminal unit heat is [disabled / controlled to occupied mode zone setpoint]. Constant Volume Terminal Units with Reheat terminal unit controller. The controller modulates the primary air damper in order to deliver a constant amount of air from the medium pressure duct into the zone, independent of the temperature needs of the zone. If the temperature in the zone falls below setpoint, then terminal unit [electric / hot water] heat is engaged. The further the temperature falls from zone setpoint, the more heat is engaged. setback and morning warmup heating cycles. Terminal unit heat is disabled. Reheat Coils ERH-1 through ERH-16 (Modify the following description, or find a more appropriate one to customize) Reheat system air handler serves a system of electric reheat coils. The duct heaters are disabled, via their integral air proving switches, if the air handler supply fan is off. When enabled, the heaters operate to maintain individual zone comfort levels. For heaters with two stages (or less), a zone mounted multistage thermostat controls the heater. As the zone temperature falls from setpoint, the thermostat steps through stages of heat as required to maintain the desired comfort level within the zone. For heaters with more than two stages, a unit mounted step controller, wired to a zone mounted temperature sensor, controls the heater. As the zone temperature falls from setpoint, the step controller steps through stages of heat as required to maintain the desired comfort level within the zone. Exhaust Fans (Roof mounted / Wall mounted / Inline / Ceiling appropriate electrical characteristics appropriate control method) Wall mounted exhaust fan (fractional HP @ 120/1/60) serves the trash room, and runs continuously. Inline exhaust fan (fractional HP @ 120/1/60) serves the pantry, and is controlled by a wall switch located in the space served.

Wall mounted exhaust fan (fractional HP @ 120/1/60) serves the electrical room, and is controlled by a wall mounted thermostat located in the space served. Wall mounted exhaust fan (fractional HP @ 120/1/60) serves the electrical vault, and is controlled by a wall mounted thermostat located in the space served. A motorized outside air intake damper is interlocked with the operation of the fan. Roof mounted exhaust fan (3/4 HP @ 460/3/60) serves the main bathrooms, and operates via a time-of-day schedule as per [a local time clock / the DDC system]. Wall mounted exhaust fan (fractional HP @ 120/1/60) serves the generator room, and is interlocked to the operation of the generator. A motorized outside air intake damper is interlocked with the operation of the fan. Garage Ventilation System G through GEF-4, CO Detection & Ventilation Computer Room A/C System CRU-1 & CU-1 (Modify the following description for an air-cooled split system, or find a more appropriate description to customize) Indoor unit CRU-1 and outdoor unit CU-1 make up a split system that serves the Server Room. The indoor unit operates via local wall mounted controls [temperature and humidity controllers / microprocessor panel] in order to maintain the proper level of environmental control in the space. The outdoor unit is engaged upon calls for cooling and/or dehumidification by the indoor controls. Hot & Chilled Water System B-1 & B-2 CH-1 & CH-2 P-2 & P-2 (Combustion Air and/or Refrigerant Monitoring/Ventilation System as required) Unitary Heating Equipment Electric Wall Heaters EWH-1 & EWH-2 Electric Unit Heaters EUH-1 & EUH-2 Electric Baseboard EBH-1 thru EBH-4 (Modify the following description, or find more appropriate ones to customize gas fired, hot water, steam ) Miscellaneous electric heaters located throughout the facility are to operate via integral, unit mounted thermostats. See plans for locations.

Miscellaneous Equipment (Include any miscellaneous equipment not covered herein, and customize a description for it) Split System A/C-1 & CU-1