Operation Manual. WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. (Version 2.1.1) written for WAC-47/-60/-80/-100 models

Similar documents
WiseBath WSB Shaking Water Bath Operation Manual (Version 1.4.0)

Operation Manual (Version 1.4.4)

Operation Manual (Version 1.5.1)

Operation Manual. (Version 1.5.1)

Operation Manual. VWR Vacuum Ovens. (Version 2.0.0) VWR Vacuum Oven , , , ,

Owner s Manual Window Air Conditioner

SX-300 SX-500 SX-700

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

Manual Page 1 of 8. Manual. Laboratory autoclave

Instruction Manual for Electric Ovens OO757X OO986X

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

Forced Convection Constant Temperature Oven. Instruction Manual

ULTRA LOW TEMPERATURE FREEZER. User Manual

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

Moveable Air-conditioner User s Manual

Bona Portable DCS Manual and safety instructions

DAIHAN New Generation New Steam Sterilizer, Digital Fuzzy Controlled Autoclave

Dyna-Form Air. Alternating Pressure Relief Overlay System

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

INSTRUCTIONS CertoClav EL

ENGLISH (Original instructions) INSTRUCTION MANUAL. Demolition Hammer HM0810TA DOUBLE INSULATION. IMPORTANT: Read Before Using.

PolySprint. Operation Manual PSM-NIT-13004E. Follow this manual when using Nitta PolySprint Heat Press.

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

Inverter Split-type Room Air Conditioner

Air Paper Jogger AJ-700 Operation Manual. Keep this manual at hand where it can be referenced at any time.

NON-DUCTED TYPE SMOKELESS BBQ ROASTER MODEL NJG-C

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

INSTRUCTIONS AND WARRANTY

Sip Vacuum Cleaner 1400/35 Wet & Dry

30-pint Dehumidifier User Guide

Operating Manual "Mark II" Solid-State Digital Automatic Controlled Sterilizers

INSTRUCTIONS AND WARRANTY

Ionizer (Static Remover) STABLO-EX Instruction Manual

Table of Contents. English

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual

Built in Electric Ceramic Hob. Instruction Manual

TABLE OF CONTENTS FOR YOUR SAFETY

Corning LSE Benchtop Shaking Incubator

Table of Contents DIGITAL DRYING OVEN. Features. Setup. Cautions. Description of the parts. Temperature Controls. Maintenance and Storage

Safety and Instruction Manual

Mobile Air Conditioner Instruction Manual Model TC-N9KM

INSTRUCTIONS AND WARRANTY

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

ENGLISH (Original instructions) INSTRUCTION MANUAL. Belt Sander DOUBLE INSULATION. IMPORTANT: Read Before Using.

English... 5 Čeština Slovenčina Magyarul Polski Русский... 85

MODEL 7000 SUCTION UNIT

CONTENT. Precautions to Avoid Possible Exposure to Excessive Microwave Energy.. Important Safeguards... Control Panel...

Product Manual Glue Applicators MS 80 and MS 200

CTA15-2 warming drawer. operating and installation instructions

Model:DKG610(V)/650(V) Model:DKG810(V)/850(V)

GDDEM10 DEHUMIDIFIER

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

INDUCTION COOKER User Guide

Read these instructions before using and keep them available at all times!

3. To protect against electric shock, do not immerse cord, plugs, or machine in water or other liquid.

INSTRUCTIONS AND WARRANTY

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

- 1 - Updated on 18 March, 2010

Autoclaves. Steam Autoclaves

Magnetic Stirring Systems with Heat

Bona DCS70/Portable DCS Manual and safety instruction

Electric Salamander CHM-1200W CHM-2400W CHM-4350W. User s Manual

Instructions for Use Warming Drawer. Bedienungsanweisung Wärmeschublade. Notice d'utilisation Chauffe-vaisselle. Gebruiksaanwijzing Servieswarmer

Read these instructions before using and keep them available at all times!

Far-infrared Oil Heater Owner's manual

DOC JAN06 LT 200

Instruction Manual Suppository Penetration Tester. Type PM 30

Operations Manual. Part Number: For Research Use Only

3 in 1 Garden Vacuum 9255 Instructions for Use

6L PRESSURE COOKER. Instruction Manual. Model: PLA1424

SHORT WAVE INFRARED PANEL DRYER

Operator s Manual S-333. Automated Soil Compactor. Version 3.3. Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA USA

Operation Manual RANGE HOOD

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

Operating Instructions

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

Washing Machine OWNER S MANUAL TRWTL-70. Before using your washing machine, please read this manual carefully and keep it for future reference.

INSTRUCTIONS AND WARRANTY

- 1 - Updated on 18 March, 2010

TAIJI HOTCABI Towel Warmer

TECHNOSKLO Ltd. Držkov

* depending on model.

INSTALLATION AND OPERATION MANUAL

BL Series INSTRUCTIONS

INSTRUCTIONS AND WARRANTY

ASPIRE Laboratory Aspirator

TM585. Refrigerator - Freezer Operation manual. Contents

Instruction Manual Item No.: V~, 60Hz

CRISTAL Built-in Dish Sterilizer Instruction Manual

ENGLISH (Original instructions) INSTRUCTION MANUAL. Power Mixer UT2204 DOUBLE INSULATION. IMPORTANT: Read Before Using.

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Hand Held Steamer DF-A001 User Manual

Seaward Products. OWNER S MANUAL Installation Operation - Maintenance. Princess Gourmet Model 345. Built-in Electric Oven ELECTRIC WALL OVEN

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

Transcription:

WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves Certifications by - - - CE /MDD Marked Products. ISO 9001 Certified. PL Insurance. Validation(IQ&OQ) Service. Patented( No. 10-0554098) Jog Shuttle Control System. Operation Manual (Version 2.1.1) written for WAC-47/-60/-80/-100 models WAC-60 WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves, 60Lit. Sales & Basic A/S : By the Nearest Official Distributors. Man201 (02 Jul. 2013)

EC Declaration of Conformity DAIHAN Scientific Co., Ltd. Seoul-city, Korea declares that the medical device described hereafter, Autoclave Model No. : WAC-47, WAC-60, WAC-80 has been classified as Class lia (Annex IX Rule, 9) and is in conformity with the essential requirements and provisions of Council Directive 93/42/EEC, is subject to the procedures set out in Annex II of Directive 93/42/EEC under the supervision of Notified Body Nemko AS (NB. No ; 0470), P.O.Box 73, Blindern, N-0314 OSLO, Norway. Safety Performance EN 60601-1:1990+A1:1993+A2:1995 +A3:1996 EMC EN 60601-1-2 :2001 June, 2008 Quality Assurance Director DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 2/51

DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 3/51

Contents Page 1. Safety Instructions........ 5 2. Before Use...... 7 3. Introduction... 8 4. Package Contents... 9 5. Appearance and Naming... 10 6. Installation...... 13 7. Cautions in Use... 15 8. Controller Details... 19 9. Operation... 20 10. Specifications... 27 11. Functional Block Diagram... 28 12. Maintenance... 29 13. Troubles & Solutions...... 30 14. Certificate...... 31 DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 4/51

Safety Instructions 1 Please read this carefully for the safety before using the device. The indicated cautions are related to the safety and you should observe all safety and warning instructions. Symbols (Pictograms) and the meaning This symbol indicates caution (Including warning). There will be concrete descriptions. This symbol indicates inhibition regarding modification. This symbol indicates inhibition. There will be concrete description. This symbol indicates caution regarding heat. This symbol indicates the risk of explosion or fire. This symbol indicates the user must be kept away while operation. This Symbol indicates that this product is to be collected separately. The following apply only to users in European countries: This product is designated for separate collection at an appropriate collection point. Do not dispose of as household waste. This product is required to comply with the European Union s Waste Electrical & Electronic Equipment(WEEE) Directive 2002/96/EC Please read following warning for safety and proper use. WARNING Do not use a power source other than which the unit is designed to operate on. Inappropriate power supply may result in damage to the equipment. Adhere to all electrical codes. Please do not touch with wet hands. It may be caused an electric shock. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 5/51

Do not handle the power cord harshly. Disconnection or short may cause if you bend or put a heavy thing on the device. When you take a plug out in a wall socket, turn the power off and then take the plug out carefully. Insert the plug securely into a wall socket. Loose connections result in excessive heat generation to the device and may cause arcing to occur at the connection. Avoid using multi-point extension power cords. It may cause excessive heat generation and be the cause of a fire. If you extend the power cord, use the cord to have sufficient electric capacity. Be sure to operate the device only with the specified power supply. When you connect the product specified by 100V to 200V, it may be caused to over-heat, electric shock or a short circuit to each part. Do not connect wrong electricity since it is the cause of a fire. Disconnect the power supply plug if the unit is not going to be used for an extended period of time. This Symbol indicates that this product is to be collected separately. The following apply only to users in European countries: This product is designated for separate collection at an appropriate collection point. Do not dispose of as household waste. This product is required to comply with the European Union s Waste Electrical & Electronic Equipment(WEEE) Directive 2002/96/EC Refer to the Warnings regarding Installation stated in the Section 7. Refer to the Warning and Cautions regarding use of the device stated in the Section 8. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 6/51

Before Use 2 Thank you very much for purchase of WiseClave Sterilizer). WAC-47/-60/-80/-100 Autoclave (Steam This operation manual describes performance, proper usage, cautions and notices for use of the purchased product. Before use, please confirm this manual and use properly. Please read carefully and thoroughly all the safety instructions described in the Section 1 again. And also, please keep this manual. Modifications of exterior, interior, mechanism, electric/electronics or any other specifications could be made without notice to improve the quality and performance of the product. PL Insurance Coverage In preparation for accidents that may develop in the course of using products produced by DAIHAN Scientific, we subscribed to following PL Insurance coverage to give our customers a piece of mind when using the product. [Contents] Insurance: Products Liability Insurance Issuer: Machinery Insurance Cooperative Limit of Liability: Bodily Injury/Property Damage, 100 million KRW each Territory: Worldwide (U.S Excluded) Emergency Contact: DAIHAN Scientific (TEL: 82-2-967-5235, FAX: 82-2-967-5231) DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 7/51

Introduction 3 WiseClave WAC-series Autoclaves (Steam Sterilizers) are useful for various kind of laboratory works such like Chemistry, Life Science, Medical Science, Pharmacology, etc. Convenience and safety in use is considered in developing and manufacturing this product. Key features are as follows; DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 8/51

Package Contents 4 WAC-47/-60/-80/-100, Autoclave (Steam Sterilizer)... [ 1 ] Wire Basket Set... [ 2 ] Operation Manual... [ 1 ] Models (a) WAC-47 : Steam Sterilizers, Digital Fuzzy-controlled Autoclaves, 47Liter. (b) WAC-60: Steam Sterilizers, Digital Fuzzy-controlled Autoclaves, 60Liter. (c) WAC-80 : Steam Sterilizers, Digital Fuzzy-controlled Autoclaves, 80Liter. (d) WAC-100 : Steam Sterilizers, Digital Fuzzy-controlled Autoclaves, 100Liter. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 9/51

Appearance and Naming 5 1. Exterior 6 5 10 4 1 2 3 7 8 9 <Front View> < Left Side View> 1 Lever 2 Lid Stiffener 3 Lid Clamp 4 Lid with Silicon packing 5 Pressure Gauge 6 Control Panel 7 Door Fastener 8 Door of Room for Electric Distribution Plane and Pipe Assembly 9 Moving Wheel 10 Expention Open Hole DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 10/51

10 11 10 < WAC-47 & -60 model> 10 12 13 <WAC-80 & -100 model> < Rear Side View> 10 Power Switch and/or Leakage Breaker 11 Power Cord 12 Plug (for Single-phase 230V AC with Ground) 13 Socket with Wiring connector DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 11/51

2. Pipe Assembly and Electric Distribution Plane 14 15 14 Safety Knob 15 Manual purge valve 16 Water Drain Valve 16 DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 12/51

Installation 6 1. After receiving the unit and putting it on the specified place of use remove the wrapping. 2. After positioning the unit, lock the moving wheel 10 in order to make position fixed and the unit stable. 3. Check the unit whether there are eventual transport damages or not. In case there are some transport damages found please inform the forwarder and your contractor. If there is no damage, please go to next point 3. 4. Let the unit stand for a few minutes so that the all the internal parts and components of the unit can be stabilized. 5. Open the door at the left side of the unit. You can find a room for pipe assembly and electric distribution plane. Please check carefully if there is anything wrong including disconnection of the electric wire, breakage of pipe or fitting element. In case there is any kind of damage found, please inform the forwarder and your contractor. If you cannot find anything wrong, please go to next point 5. 6. For normal use of the unit, confirm that the valve 16 is open, and water drain valve closed. 7. Connect the main power cord to the socket. 8. (NOTE) If you bye WAC-80 or WAC-100, power consumption of the heater in the vessel is too high to use normal wall socket. (Typical wall socket in EU and Asian countries permits around 3kW maximum per socket) So, a big 3-pole plug (for single-phase 230V AC with ground) 13 comes with power cord, and a socket with wiring connector 14 is supplied together as seen in the picture on the page 10. You have to wire the power supply line of enough electric power (4kW for WAC-80 and 5kW for WAC-100 at least) to the supplied connector 14 before plugging. 9. If such a big power supply line is not available in the room where the unit is installed, you have to contact the appropriate person who is in charge of electric facilities in your company or organization. 17 is DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 13/51

WARNING Place the device on a level, horizontal surface (floor) to support the capacity of the device without vibration. Do not install at a dangerous place. Do not operate the device where there are flammables. It could be caused serious accidents like explosion or fire. Do not operate the device outside. Avoid areas where the sun shines or rain directly on the device. It is very dangerous as cause over-heat or a short circuit. Do not tilt or lay down the device, and do not impact the body of the device. The device includes shock-sensitive pipes and fittings, which could be damaged by the tilt or impact. Do not install the device where it can get damp or dust. It may be caused overheating, a short circuit or a fire by damp or dust inside of the device. Do not use this device when temperature falls below 20 C and rise above 40 C. Do not use the device at a place with high temperature. Do not operate the device near a heater, blowing an air-conditioner. It may be caused an accident by overheating. The device should be set at a well ventilated place. Be sure the holes on the side or rear surface of the body are not blocked by a wall or an object. Do not operate the device at a poor ventilated place or use closed. It may cause a fire or damage of the device as not to release heat or insufficient ventilation may result. Set the device a lightening place. When you set the device at a dark place, it may cause an unexpected accident by mistake in operation. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 14/51

Cautions in Use 7 WARNING Be careful to operate the device. You MUST read this manual carefully and completely before using. The device should only be operated by laboratory personnel especially trained for this purpose and familiar with all precautionary measures required for working in a laboratory. If unexpected sound, smell or smog is generated after connecting electric power, pull out the main plug and contact manufacturer or a supplier. Do not put any objects insides. When an object that is easy to be combustible is like a stone, a metal or paper goes insides, it may cause a fire, an electric shock or a break down. If do, pull out the mains plug from a socket and contact a manufacturer or a supplier. Do not disassemble or remodeling by yourself. It may cause damage to the designed safety. We do not have any duties for an accident, quality deterioration or a defect caused by a customer. All the mechanisms and electric/electronic devices in this machine are designed and developed by the manufacturer. The devices could be disassembled and serviced only by the engineers of manufacturer or by engineers approved by manufacturer. Do not touch the device with wet hand while operation. Do not turn on and off frequently. It could damage the compressor by overload. This device must be connected to an earthed power supply. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 15/51

CAUTION Only demineralised or distilled water MUST be used. If dirty water is used, it will cause damage of all the components inside the vessel, inner surface of the vessel, pipes, fittings and valves. Do not use tap water! Prior to sterilization, check sterilizing chamber to ensure there is sufficient feed water. No sterilization without feed water! WiseClave WAC Autoclaves have been designed for the following purposes; For sterilizing glassware, rubber items, pipette tips, instruments, filter bodies, as well as consumables, waste in bags, and to destroy infectious or septic materials. For sterilizing liquids, solutions and culture mediums in open or lightly closed vessels. For sterilizing foodstuffs For streaming liquids or for dissolving agar. For non-pressurized disinfection of heat-sensitive culture media and solutions. Liquids and foods must not be sterilized in pressure-sealed containers. Easily combustible or toxic liquids must no be sterilized The following products are not suitable for sterilization; Wooden items Bonded parts Plastic materials sensitive to hot water (e.g., screw tops) Electrical equipment Vessels or instruments made from steel or iron Metering equipment, unless their suitability for stream sterilization is specifically mentioned Destruction bags must be open during sterilization, otherwise they may burst. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 16/51

Before every sterilizing operation, check that the lid stiffener 2 on the lid 4 has moved all the way into the lid clamp 3. And check the lid screw handle 1 is turned until it cannot be turned anymore. Do not open sterilizing chamber until full sterilization operation cycle is finished. Allow chamber pressure gauge to slow zero before opening the autoclave. Watch for hot steam and hot water! Hot steam may escape when the lid is opened. The lid handle should only be gripped at the experiment end. Step back when opening the sterilizer. You must wear the following protective items when opening the sterilizing chamber and removing the sterilized articles; Apron Eye protectors Heat insulated gloves Watch for hot surfaces and hot steam! OPT sensor (SAFETY) knob should be set as operating temperature +20 ~ +30 C. Please be noted that the heater doesn t work if the knob is set to 0 position. When sterilizing liquids, do not fill vessels more than two-thirds full, as otherwise liquids may boil over. Do not sterilize pressure-sealed vessels. Explosion hazard! Watch for broken glasses! Never use for a explosive sample. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 17/51

After sterilizing liquids; Danger from retardation of boiling. For open vessels containing up to 1 liter: wait at least 2.5 hours For open vessels containing up to 2 liters: wait at least 3 hours Do not remove flasks or bags until the chamber temperature drops below 70 C. Do not hang onto or lean against the open lid. DO not climb onto the autoclave, as this may cause the autoclave to tilt. Please avoid ultrasonic lamps. The unit could be cracked or faded. Disconnect the power supply plug if the unit is not going to be used for an extended period of time. This Symbol indicates that this product is to be collected separately. The following apply only to users in European countries: This product is designated for separate collection at an appropriate collection point. Do not dispose of as household waste. This product is required to comply with the European Union s Waste Electrical & Electronic Equipment(WEEE) Directive 2002/96/EC DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 18/51

Controller Details 8 21 22 18 Temp(Timer) SV Temp(Timer) PV 23 19 25 24 20 18 Digital LCD with back-light : SV and PV of Temperature, SV and PV of Timer (Operation Timer and Delay Timer) are displayed. 19 MAIN mode button : Selection of main operation mode. (Set Operation Time mode, Set Temperature mode and Safety Locking mode) 20 SUB mode button : Selection of subsidiary operation mode. (Set Delay Time mode, Set Offset Temperature mode and Set Operation Cycle mode) 21 TIMER lamp : indication of Timer setting and status. 22 HEAT (Heating) lamp : indication of Heater setting and status. 23 Error lamp 24 Jog-shuttle knob : Turn + Push - Setting the value of Temperature or Timer by Turing. - Start and stop by Pushing. 25 Door Open Button DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 19/51

Operation 9 1. Preparation for Use DAIHAN Autoclave is a kind of Steam Sterilizer. So the user should fill water into the pressure vessel before operating the unit. (NOTE) Distilled water should be used. The user should pour water to the pressure vessel, so the bottom part of the vessel (bottom cover) should sink under the water. (NOTE) If the water level is too low, the machine cannot start sterilization operation by the functioning of water level sensor equipped in the vessel. (NOTE) Closing of manual ventilation valve 7 must be checked. (NOTE) Opening of valve 16 must be checked as well. This valve can be closed only for the diagnostic purpose by an authorized engineer. Connect the power cord to the proper power socket. (NOTE) If you bye WAC-80 or WAC-100, power consumption of the heater in the vessel is too high to use normal wall socket. So, a big 3-pole plug (for single-phase 230V AC with ground) 13 comes with power cord, and a socket with wiring connector 14 is supplied together as seen in the picture. You have to wire the power line of enough electric power to the connector 14 before plugging in order to use the machine. Turn on the Main Switch 11. At this moment, if the water level in the vessel is not sufficient, LCD shows Low-Level error message with buzzer sound. In this case, supply more water until you can see the normal status (Set Timer mode) on the LCD. (NOTE) Set the OPT sensor knob 15 to 20~30 C higher than operation temperature (eg., If your operating temperature would be 121 C, proper value of the OPT sensor would be 150 C). Please be noted that the temperature on the scale is rough values. 2. Preparation and Placing of Materials All materials autoclaved must be placed in an autoclavable tray (wire basket delivered together with machine) with sides that are at least 5 inches in height. The use of trays should eliminate anything boiling over and spilling into the autoclave. Therefore, all materials must fit within this tray. Only autoclavable materials may be placed in the autoclave. If you are unsure if something is autoclavable, check with the manufacturer. Liquids to be autoclaved must be in an autoclavable vessel that is at least twice as large as the volume to be autoclaved (i.e. If you are autoclaving 1 liter of media, you need to put it in a flask that hold at least 2 liters). This allows for boiling during the cycle. Caps DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 20/51

must be slightly loose so that pressure created during the cycle does not cause the vessel to break. For screw cap containers you can make the lid hand tight and then loosen the lid by one-half turn. Dry goods (solids) must be placed in an autoclavable tray with 5-inch sides also. Garbage must be put in autoclavable bags and inside the autoclavable trays with 5-inch sides. Sharps containers must also go into the same type of autoclavable trays. To ensure proper sterilization of both garbage and sharps containers, 1 liter of water should be added to the bags or sharps containers. This water will vaporize during the autoclave cycle to allow better penetration of steam and more efficient sterilization. Autoclave garbage bags must be tied off. (WARNING) Use of non-autoclavable trays and containers may result in injury to the user and damage to the equipment. After placing the material to be autoclaved, close the lid 4 of pressure vessel by turning the lid handle 1 clockwise until it cannot be turned anymore. 3. Preview of Controller Mode Transition By the simple combination of MAIN button 19, SUB button 20 and Jog-shuttle knob 24, WAC autoclave offers outstanding simple user-interface with maximum efficiency and convenience for controlling overall functions of the machine - Patent registered The following diagram briefly shows the overall mode transition mechanism; Power ON SUB Set Timer mode Set Delay Timer mode MAIN MAIN SUB MAIN Set Temperature mode Set Temperature Offset mode MAIN MAIN SUB Locking mode Set Operation Cycle mode MAIN DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 21/51

4. Set Operation Cycle Mode WiseClave WAC autoclaves offer two different operation cycles named SOLID cycle mode and LIQUID cycle mode. As the name implies, LIQUID cycle is for autoclaving liquids while the SOLID cycle is for autoclaving solid or dry materials. With SOLID cycle mode operation, steam is ventilated out quickly after the completion of sterilization. On the other hand, with LIQUID cycle mode, steam is ventilated out very slowly after sterilization. The following table shows you the difference of the two cycles and proper use; Type of Cycle SOLID or fast exhaust LIQUID of slow exhaust Appropriate Material Dry goods, glassware, etc. Liquids Description This cycle charges the chamber with steam and holds it at a set pressure and temperature for a set period of time. At the end of the cycle, a valve opens and the chamber rapidly returns to atmospheric pressure. This cycle prevents sterilized liquids from boiling. Steam is exhausted slowly at the end of the cycle, allowing the liquids (which will be super-heated) to cool. By pushing MODE button 19 and SUB button 20 sequentially, you can enter into the Set Operation Cycle mode. Factory default mode is SOLID cycle. By pushing jog-shuttle knob 24, you can change the cycle, which is toggled by pushing repeatedly. Cycle shown on the LCD currently is the selected operation cycle. 5. Setting Timer 5.1 Set Operation Timer The initial mode after power-on is Set Operation Timer mode. TIMER lamp 21 is blinking. (NOTE) Operation Time means the Sterilization time. This timer begins to run (count down) when the Temp PV (present temperature) reaches the Temp SV (set temperature). Tim SV on LCD indicates set value of operation timer and Tim PV indicates present value (remaining time) of the timer. (NOTE) Initial value (SV) of the timer is 00:00, which means infinite time. With zero value of Timer SV, the machine cannot start operation. Turn the Jog-shuttle knob 24 then SV and PV change together. SV can be set in 1 minute, and the maximum value is 99:59 (99 hours and 59 minutes). Set required time by turning the Jog Knob 24 and PUSH it to complete the timer setting. Then timer is started and TIMER lamp 21 is on. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 22/51

(NOTE) By pushing the jog-knob 24 with set value, the timer begins to operate but doesn t start actual counting before beginning sterilization. It counts down when the Temp PV (present temperature) reaches the Temp SV (set temperature) as mentioned above. The machine stops operation (heating) after the SV of timer has passed. 5.2 Set Delay Timer It turns to Set Delay Timer mode by pushing SUB button 20 in Set Operation Timer mode. TIMER lamp 21 is blinking. DTim SV on LCD indicates set value of delay timer and DTim PV indicates present value (remaining time) of the timer. Set required time using the Jog Knob 24 and push it to complete the timer setting. Then timer is started and TIMER lamp 21 is on. The machine starts operation (heating) after the SV of delay timer has passed. It returns to Set Operation Timer mode by pushing MAIN button (NOTE) While the machine is being operated already (by setting operation timer, temperature and heating start), delay timer operation cannot be set and started. 19. 6. Set Temperature 6.1 Set Temperature It turns to Set Temperature mode by pushing MAIN button 19 in Set Operation Timer mode. HEAT lamp 22 is blinking. Temp SV on LCD indicates set value of operation temperature and Temp PV indicates present value (measured value by temperature sensor in the pressure vessel) of the temperature. Turn the Jog-shuttle knob 24 then SV changes. SV can be set with the resolution of 0.1 C. The maximum value is 132.0 C and the minimum value is 25.0 C. Set required operating temperature by turning the Jog Knob 7 and PUSH it to complete the temperature setting. The controller starts operation of heater in order to reach the set temperature. HEAT lamp 22 is on. (NOTE) As mentioned in the section 5.1, the machine cannot start heating (sterilization) operation without setting the operation timer to non-zero value. 6.2 Temperature Offset WiseClave WAC autoclaves intelligently and precisely controls the temperature inside the pressure vessel by digital Fuzzy control system, so high precision with low over/undershoot is assured. But, some users want to synchronize the temperature PV of the machine to the temperature value measured by other thermometer that is used as a reference meter for the DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 23/51

whole experimental process. In such a case, WAC autoclaves offer a function of adjusting the temperature PV within 10.0 ~ +10.0 C User s self-compensation function. It turns to Set Offset Value mode by pushing SUB button 20 in Set Temperature mode. Temp PV on LCD indicates current temperature and Offset indicates the value to be added to PV temperature (compensation value). Turn the Jog-shuttle knob 24 then Offset and Temp PV changes together. Offset can be set with the resolution of 0.1 C, and input range is 10.0 to +10.0 C. Temp PV shows value added or subtracted by Offset value. It returns to Set Temperature mode by pushing MAIN button 19. 7. Locking Mode It turns to Locking mode by pushing MAIN button 19 in Set Temperature mode. In this mode, turning or pushing Jog knob doesn t work. So, you could prevent any changes of set values by mistake. Operation Timer PV and Temp PV are shown on LCD. It returns to Set Operation Timer mode by pushing MAIN button 19. 8. End of Sterilization When the set time has passed and the sterilization is finished, firstly heating is stopped, and then, the steam and pressure is exhausted out and the pressure is removed. User can identify this by buzzer sound for 30 seconds. As described in the section 4 of this chapter, the way of exhausting steam and pressure is different based on the operation cycle. In SOLID cycle mode, valve is opened completely and steam is discharged quickly. In LIQUID cycle mode, valve is not completely opened at a time. Firstly it waits for 5 minutes with valve closed after heater OFF. And then, the valve is opened during 3 seconds, after that the valve is closed again for 2 minutes, and then it reopens during 3 seconds, etc. This procedure repeats until the temperature comes down to 90 C (lasts approx. 30minutes), and then it waits until the temperature reaches down to 80 C with valve closed again. After that, the valve is closed completely. While steam is discharged out of the pressure vessel, the user cannot see the steam out. Steam in the vessel is converted into water by passing trough a specially designed steam condenser. This feature offers safety and convenience to the user. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 24/51

9. After Sterilization When the sterilization is completed, pressure is exhausted through steam discharging automatically. You could check it with the pressure gauge 5 next to control panel. After the pressure comes down to 0 ~ 0.2 kg/cm 2, you may open the lid by turning lid handle counterclockwise. If you want to confirm the complete ventilation of the steam and pressure, you may use the manual ventilation valve 7 at this moment. If you want to remove the water remained in the vessel, you could do it with the drain valve. User can open the door at the left side of the body, and can find the water drain valve 17 there. Connect a kind of tube to the valve and open it, then the water remained in the vessel can be poured out. 10. Storage Function In each setting mode (Set Operation Timer mode, Set Delay Timer mode, Set Temperature mode, Set Offset Value mode and Set Operation Cycle mode), you can store the current set values by simply pushing the Jog knob for 1 second. For showing the value is successfully stored, the set value on LCD blinks three times. Even though you turn off the machine, the set values are stored permanently, so you can re-use the values for the next time of operation. 11. 비상시 Lid 잠금장치해제방법 (Emergency Lid unlock method) 본기기는사용상의안전을위해전자식 Lid 잠금시스템이장착되어있습니다. 하여전원이공급되지않거나기기전원부의이상이있을경우 Lid를 Open버튼동작으로열수가없게됩니다. 이런경우다음과같은방법으로 Lid를열어주십시오. < 그림.3> 비상시 Lid잠금장치해제방법 과같이 Lid중심축부위에 Lid잠금해제홀이있습니다. 이곳홀에적당한사이즈의도구 ( 육각렌치등 ) 을삽입하십시오. 개폐장치가열리는소리를확인하고도구의삽입상태를유지한상태로 Lid를들어올리십시오. Lid를들어올리는힘을유지한채로도구를천천히빼면서 Lid를끝까지여십시오. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 25/51

Emergency Lid unlock method 적당한사이즈의도구 ( 육각렌치 ) 등을삽입하여개폐장치가열리는소리를확인한다. 도구의삽입상태를유지한상태로 Lid를들어올린다. *Lid를들어올리는힘을유지한상태로도구를천천히빼면서 Lid를끝까지연다. 그림.3> 비 < 그림.3> 비상시 Lid 잠금장치해제방법 DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 26/51

Specifications 10 Technical Information DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 27/51

Functional Block Diagram 11 DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 28/51

Maintenance 12 1. If you don t use the device for a long time, please plug out, dry up the machine and keep with packing. 2. When you need exchange of a component for repair, you MUST use an original component provided by manufacturer. 3. In the warranty period specified on the warranty sheet included in this operation manual, breakdown of the machine in spite of normal/proper use will be treated by manufacturer or by an official agent of manufacturer. 4. The manufacturer or its agent is not in charge of breakdown caused by abnormal use or by ignoring the warnings and cautions described in this manual. 5. Before cleaning the machine, please be sure to pull the power cord off. 6. For cleaning of the machine, we recommend you to use neutral detergent and soft cloth. Do not use coarse cloth, strong chemicals or organic solution. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 29/51

Troubles and Solutions 13 Situation Confirmations and Solutions Power failure Check the power cord is plugged. Check the supplied electricity is proper and regulated. Check the Leakage breaker is ON. Not heating Check the temp SV and confirm the operation started by pushing Jog knob. Check the MAIN power switch is ON. Check the SAFETY knob is set to too lower value than recommended value and not set to 0. Heating but it doesn t reach the SV temperature Problem in the heater or temperature sensor. Please call technical service. Noise The noise could be generated by the fan equipped in the steam condenser. If it becomes too big, please call technical service. If you have any problem other than the above, please call technical service of manufacturer or an official agent. DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 30/51

CERTIFICATE of Quality Tested by Manufacturer and Free Warranty up to 2 years for Laboratory Instrument Limited Warranty 1. This instrument has gone through our testing process about all functions before shipment. 2. This instrument is warranted for 2 years from purchasing date. 3. A breakdown caused by customer s improper use or natural disaster is excepted from this warranty. 4. This certification is only for international customers. Item Model No. Serial No. Date Customer WiseClave WAC, Autoclave (Steam Sterilizer) DAIHAN Scientific Co., Ltd. Daihan Bldg., 24-4, Sangwolgok-Dong Seongbuk-Gu, Seoul, KOREA, 136-120 TEL: +82-2-967-5235, Ext. 129 FAX: +82-2-963-5231 Email: daihan@daihansci.co.kr www.daihan-sci.com www.allforlab.com DAIHAN Scientific, WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. 31/51