MERIDIAN UNIVERSAL GAS DETECTOR

Similar documents
Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection

SIL 2. Ultima X Series Gas Monitors CERTIFIED

and storage tanks. CO and NOx detection from diesel engine emissions Hospitality Hotels and restaurants LPG detection in commercial kitchens

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

ESD3000 ESD200 Combustible / Toxic Gas Detector

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

ESD500. ESD500 Combustible / Toxic Gas Detector

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Toxic Gas Detection. Model F12. Toxic Gas Detection

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

GAS PLUS ALARM SYSTEM

OLC(T) 100 FIXED GAS DETECTOR

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

APPLICATION DATA SHEET

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

3M Oldham OLCT 100. Description. Fixed Gas Detector

ESD3000IR ESD3000IR. Infrared Gas Detector

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

Model D12-IR. Digital Gas Transmitter...

Model D12. Digital Gas Transmitter

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Dräger Flame 2100 Flame Detection

Dräger PEX 3000 Flammable Gas Detection

Sieger Apex. Flexibility that meets your requirements

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Dräger Flame 2500 Flame Detection

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

Frequently Asked Questions

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Dependable Solutions for Gas Detection

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

ULTIMA X5000. MSAX5000.com

SP-220. Features. Combustible handheld gas leakage detector

ALTAIR 5X Multigas Detector Product Specification

S5000 Gas Monitor. GMS5000.com

Installation and Wiring 1.

Dräger Polytron SE Ex Fixed Gas Detector

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Explosion-proof Duct Heaters

SBS-H2 Hydrogen Gas Detector Kit

GAS DETECTOR ST400EC PART.NO

Dräger Polytron 5700 IR Detection of flammable gases and vapours

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

The SharpEye 40/40M (Multi IR) Flame Detection

The Art of Gas Detection

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Zareba Sensepoint Pro

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Electron Microscopy Sciences

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW

Dräger Polytron 8310 IR Detection of flammable gases and vapour

The SharpEye 40/40I (IR3) Flame Detection

MODEL: Q8 SERIES NON-INTRUSIVE CALIBRATION GAS TRANSMITTER/SENSOR

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Searchpoint Optima Plus

Combustible Gas Detection and Control System

Dräger Polytron 7000 Fixed gas detector

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Thank You for Attending Today s Webinar:

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

Dräger Polytron 8000 Stationary gas detector (EC)

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

Dräger Flame 2100 (UV) Flame Detection

Hazardous area descriptions

Dräger Flame 2500 (IR3) Flame Detection

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

SUPREMATouch Modular Fire & Gas Detection System

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

Dräger Flame 2700 (Multi-IR) Flame Detection

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Dräger Polytron 8700 IR Detection of flammable gases and vapors

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

incontrol Systems Inc. Flame and Gas Detection

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Manufacturers of Explosion Proof, Corrosion Resistant and Severe Duty HVAC/R Systems, and Pressurization Equipment.

Transcription:

MERIDIAN UNIVERSAL GAS DETECTOR

MERIDIAN UNIVERSAL GAS DETECTOR The term universal is frequently used in the industry to characterize gas detectors that address both toxic and combustible gases, but it is rare to find instruments that truly live up to that claim. Upon close inspection, you will find that often the only characteristic that can be called universal is their user interface. In other words, the instrument provides a common user interface for both combustible and toxic gas detection. THE FOLLOWING ACCESSORIES ARE AVAILABLE FOR THE MERIDIAN TRANSMITTER: CALIBRATION ADAPTER: Easily attaches to the sensor housing to deliver calibration gases to the detector head. At Scott Safety, we believe universal should be much more than a common user interface, and we applied this thinking to every aspect of the design of the Meridian universal gas detector. You will find that the Meridian universal gas detector is the industry s first truly universal gas detection platform. FLOW CELL: Allows customers to bring a gas sample to the sensor. SINGLE DETECTOR HEAD FOR ALL APPLICATIONS Whether you need an infrared or catalytic bead sensor to detect combustible gases or an electrochemical sensor for a toxic environment, the Meridian universal gas detector utilizes a single detector head to easily accept all sensor types. There is no requirement for distinct DELUGE GUARD: Protects the sensor from heavy rain and water spray from plant wash down routines. personality boards in the gas detector or different detector heads to make the instrument behave as a combustible or toxic gas detector. The Meridian gas detector accepts all sensor types in one detector. Simply attach the specific toxic or combustible sensor to the universal detector head and the Meridian gas detector will automatically determine the type DUCT MOUNT KIT: Allows you to remote mount sensors onto ventilation ducts to verify. of gas to be detected. Installation of the sensor is a simple plug-and-play action. At Scott Safety, we are always looking to anticipate your future needs. We designed the Meridian gas detection platform to be future proof, allowing you to take advantage of new sensing technologies from Scott Safety while maintaining ease of use and peace of mind. SINGLE SET OF ACCESSORIES The Meridian gas detector has a single set of accessories for your application needs another merit of a truly universal gas detection platform. Because all accessories for the Meridian gas detector are designed for the universal detector head, there is no need for purchasing separate accessories for toxic and combustible applications. SENSOR SIMULATOR: A useful commissioning and troubleshooting tool to locally simulate gas concentration and trigger a response from the detector. UNIVERSAL MOUNTING KIT: With predefined cut outs, you can easily replace older gas detectors with the Meridian detector, making it an ideal choice for retrofit applications. SUN SHIELD: Deflects direct sunlight from the Meridian reducing glare on the display. It also helps reduce the internal temperature of the transmitter.

ONE DETECTOR WITH GLOBAL APPROVALS AND A PLUG-AND-PLAY DESIGN Single-user interface for all applications SAFETY INTEGRITY LEVEL: Designed with safety and reliability in mind, the Meridian universal gas detector is suitable for use in SIL-2 and SIL-3-rated systems under the IEC 61508 standards, certified by TUV- Rheinland, an independent third-party agency. Third party SIL certification validates that the product meets the most rigorous standards for reliability and performance and confirms its ability to reduce your potential for downtime and increase your safety factor. KEY REGULATORY APPROVALS: Single detector head for all applications - Toxic - Combustible (IR, catalytic bead) Sensor easily snap-fits into detector and allows for simple one-hand installation C CSA US ATEX IECEx INMETRO EURASIAN CUSTOMS UNION* CHINA Ex, CCCF* RCM* MARINE DIRECTIVE - SHIP'S WHEEL, ABS SIL-2 certified by TUV-Rheinland *Pending End cap and deluge guard for protection GLOBAL CERTIFICATIONS AND APPROVALS The Meridian gas detector is certified using the highest international standards for global use. Our goal is to offer customers one instrument that can be used across regions. So whether you procure the instrument for use in a chemical plant in North America, on an FPSO in Latin America or in an oil refinery in Europe or Asia, the instrument will have the necessary approvals required for use in that region. Unlike industry standard offerings, the Meridian gas detector is not a collection of gas detectors, each certified for use in a particular region. What makes it truly universal is that it is a single detector that has all the required approvals for global use.

ADVANCEMENT IN SENSOR TECHNOLOGY At Scott Safety, we believe in innovation with a purpose. To that end, we made a number of advancements in our sensor technology with the Meridian universal gas detector to deliver additional value to our customers and reduce their overall cost of ownership. SENSOR REPLACEMENT WITHOUT DECLASSIFYING THE AREA The Meridian gas detector s intrinsically safe, plug-and-play sensor design allows you to perform sensor replacements without powering down the instrument. You no longer need to declassify an area during sensor replacement. This allows you to maintain your plant production uptime and maintain a safe working environment for workers at the same time. TOXIC SENSORS OFFER RANGE INVARIANT CALIBRATION Sensor calibration, while absolutely necessary, can be a very challenging and time-consuming activity. To help our customers reduce operational hazard and maintenance cost, we have designed a toxic sensor technology that is linear throughout and range agnostic. With the Meridian gas detector, you can calibrate a toxic sensor to a particular gas level and then make adjustment to the range later without having to re-calibrate the sensor to the new range. For example, to optimize maintenance workload, you can calibrate sensors in a batch in the lab and set them to a default range. Upon installation, the range on the sensors can be adjusted to the requirements of the specific location. The range on the sensor can be readjusted anytime to the set of pre-defined ranges by the end user. This sensor design also provides flexibility in easily calibrating sensors where a specific gas range is inaccessible or unavailable. Simply calibrate the sensor with an available surrogate gas range and then readjust the sensor range to the set of predefined ranges available for that sensor. AUTOMATIC SENSOR VOLTAGE DETECTION AND ADJUSTMENT To minimize installation and commissioning time, the Meridian automatically detects current voltage and makes the required voltage adjustments for catalytic bead sensors without intervention from the installer. This reduces installation time and also the required tooling expertise necessary for sensor installation.

COMPLETE SENSOR RANGE & BEST-IN-CLASS SENSOR PERFORMANCE FULL-RANGE DETECTION The Universal Gas Detection System detects a full range of combustible and toxic gases. COMBUSTIBLE GASES: Acetaldehyde Diethyl Ether Acetone Ethane Acetylene Ethanol Ammonia Ethyl Acetate Benzene Ethylbenzene Butadiene Ethylene Butane Ethylene Oxide Butanol Heptane Butyl Acetate Hexane Chlorobenzene Hydrogen Cyclohexane Isobutane Decane Isobutylene Isopentane Isopropanol Methane Methanol Methyl Chloride Methylene Chloride Methyl Ethyl Ketone (MEK) Octane Octamethyl Trisiloxane Pentane Propane Propylene Propylene Oxide Styrene Tetrahydrofuran Toluene Vinyl Chloride Xylene MULTIPLE SENSORS The Meridian gas detector allows up to three sensors to be attached to a single instrument. Use the multisensor detector to: Monitor for toxic and combustible gases from the same detector. Accurately detect gases particularly difficult to detect due to cross interference from other gases. Reduce your overall cost per point of detection while increasing overall safety. Remotely mount sensors up to 100 feet from the gas detector to meet requirements of specific applications. TOXIC GASES: Ammonia Bromine Carbon Dioxide Carbon Monoxide Chlorine Chlorine Dioxide Fluorine Hydrogen* Hydrogen Chloride Hydrogen Cyanide Hydrogen Fluoride Hydrogen Sulfide Methanol Nitric Oxide* Nitrogen Dioxide Oxygen Ozone Silane Sulfur Dioxide Rock Solid Sensor available for toxic gases highlighted in bold. *Call for availability THE ROCK SOLID ADVANTAGE: MORE RELIABLE, ACCURATE DETECTION Minimal drift: Performs reliably in harsh real-world environments by significantly reducing effects of temperature and humidity. High specificity: Allows for much lower interference from other gases than conventional gas sensors, reducing cross interference from other gases present and reduces the likelihood of a false alarm. Digital ID: Provides automatic recognition when sensors are replaced, reducing the likelihood of user error during maintenance in the field. Broader toxic gas detection: Several ranges are available for each gas to optimize the sensor s response in the environment.

THE RIGHT CHOICE FOR YOUR GAS DETECTION APPLICATION MAKING THE BEST DECISION FOR TODAY One product for toxic and combustible applications with global approvals Reduces inventory costs Reduces training costs Simplifies installation Easy to install, commission and train your instrumentation workers Reduces start-up time Reduces labor associated with initial installation Reduces risk for installer error Rock Solid sensing technology offers accurate and reliable detection Reduces the impact of environmental factors Improves safety factor of the facility Advanced communication protocols offer detailed diagnostics data allowing for proactive maintenance and a safer environment Offers flexibility in developing your gas detection system through industry standard communication protocols Increases safety by allowing improved access to real-time information on the detector status and environment Incorporation of a SIL-2-rated device into your facilities operation for industry validated best-in-class performance

MAKING THE BEST DECISION FOR TOMORROW Ability to incorporate new sensing technology in the future Future proof plug-and-play design allows all future sensing technologies from Scott to easily integrate into the Meridian gas detector Ability to seamlessly incorporate new communication protocols Stay current on industry trends and take advantage of new industry standard communications protocols as they become available on the Meridian gas detection platform another example of future proof design Reduce maintenance time and cost associated with sensor calibration Innovative sensor design allows for bench calibration and range invariant calibration for toxic sensor, which optimize ongoing maintenance workloads and offer significant cost savings Scott Global Service network and Scott Plus warranty system Reduce cost, waste and environmental impact with an environment-friendly sensor design Commit to green technology initiatives and environmental stewardship COMMUNICATION PROTOCOLS: Designed for global use, the Meridian universal gas detector supports industry standard protocols for integration into any industrial network. Support for digital protocols allows for advanced diagnostics data to be available, making it possible to take proactive measures to maintain a safe environment and lowering your overall cost of ownership. Standard, wired protocols 4 20 ma Modbus Optional protocols Wired HART

The Scott story. Since 1932, Scott Safety has been committed to providing outstanding, reliable safety equipment to those whose lives depend on it. Thousands of safety workers, firefighters, police, civil defense and military personnel have counted on Scott for innovative product design, best exemplified by our industry-leading Air-Pak SCBA. We ve built a solid reputation on our attention to detail, rigorous quality assurance and exceptional service. The Meridian Universal Gas Detector continues this proud heritage. PRODUCT SPECIFICATIONS CERTIFICATIONS Global Approvals Area Classification ENVIRONMENTAL Operating Temperature Humidity Storage Temperature SPECIFICATIONS Power Operating Voltage 3/4 wire Operating Voltage 2 wire Power Consumption Enclosure Material Enclosure Ingress Protection Terminal Junction Box Material Terminal Junction Box Conduit Connection Communication Maximum 4 20 loop load, OHMS (@24 VDC) Alarms Relays Display Languages User Configuration Control User Interface Access Control Memory SENSOR SPECIFICATIONS Sensor Types Number of Sensors INSTALLATION Weight Wiring IECEx, ccsaus, ATEX, INMETRO, EURASIAN CUSTOMS UNION*, CHINA EX*, CCCF*, RCM*, INDUSTRY CANADA, CE, MARINE DIRECTIVE SHIP'S WHEEL, ABS, SIL-2 (Third Party Certification by TUV-Rheinland) Class I Div. 1 Group ABCD, Class II Div. 1 Group EFG, Class III Equipment Group I/II, Zone 0/20 & Zone 1/21, IIC -40 to 75 Celsius 5 95% RH (non condensing) -55 to 75 Celsius 2 wire, 3 wire, 4 wire 10-30 VDC (24 VDC nominal) 18-30 VDC (24 VDC nominal) 2.2-3.2 Watts based on sensor configuration Add 2.6 Watts to any configuration if heated display is used Copper-free aluminum, 316 stainless steel NEMA 4X, IP66 Copper-free aluminum, 3/6 stainless steel 3/4" NPT (M20 adapter available) 4 20 ma, MODBUS; Optional HART 680 Ohms current source 680 Ohms current sink 3 programmable alarms with set and reset (adjustable deadband); 1 fail safe system fault 4 Form C relays, rated 5 Amp at 30 VDC/240 VAC, resistive loads Graphical LCD display visible in bright sunlight. Display indicates Sensor Name, Gas Name, Full Scale of Range, Gas Concentration, Fault, Alarm Status, Trend Graph with selectable time scale showing current reading, set points and full scale. Display provides simple, intuitive calibration instructions and guides user through the calibration process. English, Portuguese, French, Spanish, Chinese, Russian Transmitter GUI, HART hand-held Communicator, MODBUS Transmitter provides controlled access to sensor range, alarm settings and other safety functions; password protection for secure configuration control Non-volatile memory ensures configuration parameters are retained in the event of power loss Combustible: Catalytic bead, Infrared sensors Electrochemical: Standard and Scott Rock Solid sensors Supports up to 3 sensors per detector Aluminum enclosure: 6.5 lbs (3 kg); Stainless steel enclosure: 11 lbs (5 kg) Detector accepts industry standard 2-wire, 3-wire or 4-wire inputs www.tycogfd.com l Copyright 2016 Tyco Gas and Flame. l All rights reserved. l GF-00037A