JAMES MOODY IM FLASH LIFE SAFETY AHJ

Similar documents
SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES

***DRAFT - NOT FOR FILING***

Guidelines for the Design Engineer

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

Laboratories and Hazardous Materials. Company Overview

ASHRAE Safety Standards. Mechanical Rooms and Gas Detection in Commercial Applications

Response to Carbon Monoxide Incidents. W.J. Streett Jr Training Section Chief

AMMONIA DETECTION BY LASER THE NEXT GENERATION OF AMMONIA DETECTION

2.1 CO is a colorless, odorless, tasteless, non-irritating, toxic gas.

BUILDING/FIRE CODE REFERENCES 2006 EDITION

Manhattan Fire Protection District

CO and NO 2 Monitoring Systems for Parking Structures

Laboratory Safety Considerations for Flammable Liquid Transfers

CARBON MONOXIDE (CO)

Life Safety Network. Intelligent solutions for advanced requirements

Presentation to. IOSH Food and Drink Group. Danny McDougall Richard Perkin

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Material Safety Data Sheet U.S. Department of Labor Occupational Safety and Health Administration

ICC CODE CORNER 2015 International Fire Code

4. The Whitman College Chemical Hygiene Officer is Fred Miller, Manager, Environmental Health and Safety.

Carbon monoxide (CO) is a colorless, odorless gas that is the product of incomplete combustion of carbon-based fuels.

Building Description Applicable Codes & Standards Prescriptive Requirements. Performance Based Design

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

ALTAIR 5X Multigas Detector Product Specification

NJSP HMRU. Module 5 B HM Operations 1

OLC(T) 100 FIXED GAS DETECTOR

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Your trusted partner in providing the best fixed Gas Detection Sales and Service in Western Canada

Sieger Apex. Flexibility that meets your requirements

PART 2. Basic Code Requirements - Semiconductor & Microelectronic Facilities using HPM s

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Chapter 12 HOT WORK OPERATIONS. Purpose:

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

CARBON DIOXIDE SYSTEMS FOR BEVERAGE DISPENSING PERMIT REQUIREMENTS

Macurco Gas Detection Products

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

Fixed Ammonia Gas Detection. Why it's needed and what it can do for you.

Setting the alarms in electrochemical sensor equipped toxic gas instruments

(h) Pesticide Application.

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Craig Wolfe Toxalert International, Inc. Mound, MN

Transmitters/Sensors. OLCT Series

Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

Changes in NFPA

Battery Powered Commercial CO Monitor

R.I.S. (Remote Intelligent Sensor)

Model Carbon Monoxide (CO) Alarm Response Policy

GENERAL STANDARD FOR GAS DETECTORS ORIGINAL EDITION MAY 1997

Ammonia Detection System Codes and Design Specifications

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

A Study on Safety by Risk Assessment of Clean Room

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

2008 NYC Fire Code. New Laboratory Standards. Operational & Maintenance Provisions effective July 2008

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

GAS DETECTION. Parking Garage Guide

Ammonia Refrigeration: What should you keep in mind?

Fixed Gas & Flame Detection International Product Range Overview

System-Connected Carbon Monoxide Detectors

MDA Scientific Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

Frequently Asked Questions

Significant Changes to the 2012 IFC Semiconductor Fabrication Facilities. Scott Stookey Senior Technical Staff International Code Council, Austin TX

Revision date: 22/4/2016 Date of print: 11/5/2016 Version: 1 Language: en-ca,us Page: 1 of 8

Item Referenced and Amendments Building 1 Building 2 Analysis, Review and Remarks. Page 1 of 15

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

MATERIAL SAFETY DATA SHEET

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

3M Oldham OLCT 100. Description. Fixed Gas Detector

SYNRAD Laser Safety 101

Safe Operation Manual. Honeywell IQ Force Gas Detector


Macurco HD-11 Hydrogen Gas Detector

Gas Detector Sensor Technology

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

GASEOUS HYDROGEN SYSTEMS

Material Safety Data Sheet

GUIDELINES. Nov GAS DETECTION SYSTEMS FOR THE REFRIGERATION INDUSTRY - AN OVERVIEW

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

This MSDS has been compiled in accordance with - EC Directive 91/155/EC - OSHA's Hazcom Standard (29 CFR )

Monitoring Flammable Vapors and Gases in Industrial Processes

Toxic Gas Detection. Model F12. Toxic Gas Detection

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Gas detection for your safety

MATERIAL SAFETY DATA SHEET

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

CHEMICAL FUME HOOD PROGRAM

The Art of Gas Detection

INTERNATIONAL STANDARD

Stand Alone DYNAGARD SP Operation Manual

Model D12. Digital Gas Transmitter

Senscient s team has more than 150 years collective experience in gas. detection.

Fire Alarm System Fundamentals

FIRE PROTECTION PROGRAM

Transcription:

TOXIC GAS MONITORING JAMES MOODY IM FLASH LIFE SAFETY AHJ

AGENDA 2 Toxic Gas Primary Gas Hazards SemiConductor Industry Code Requirements Large Toxic Gas Monitoring Systems Block Diagram TGM Detection System Flow and Control Semiconductor TGM System Integration and Controls Types of TGM Detectors New Hazardous Production Materials (New Toxic Gas) Considerations Conclusions

PRIMARY GAS HAZARDS 3 FLAMMABLE TOXIC ASPHYXIANT PYROPHORIC

FLAMMABLE GAS HAZARDS 4 Flammable Limit Each Flammable gas has a specific band of gas/air concentrations that will produce a combustible mixture, between the Lower Explosive Limit (LEL) and the Upper Explosive Limit (UEL) Lower Explosive Limit at levels below the LEL there is insufficient gas to produce an explosion, the mixture is too lean. Upper Explosive Limit Gas above the UEL the mixture has insufficient oxygen, the mixture is too rich to produce an explosion. Toxic Gas Monitoring will be done by measuring percentage of LEL, for a specific gas

TOXIC GAS HAZARDS 5 Many gases used in the Semi-Conductor industry are poisonous and can be a danger to life at very low concentrations, some have physical warning properties like smells that will notify people of their presence. (i.e. Ammonia, NH3 has a distinct smell and you will get a burning sensation around your sweat glands) However most gases are odorless, or without physical warning properties below exposure limits. Occupational Exposure Limits varies from Country to Country and in the US they even vary from State to State, in the US there are 3 major providers for setting the Occupational Exposure Limits ACGIH, OSHA, and NIOSH for reference. ACGIH, (American Conference of Governmental Industrial Hygienist) OSHA, (Occupational Safety and Health Administration) NIOSH, (National Institute for Occupational Safety and Health) TLV (Threshold Limit Value) is a reserved term of the American Conference of Governmental Industrial Hygienists (ACGIH). TLVs issued by the ACGIH are the most widely accepted occupational exposure limits both in the United States and most other countries

TOXIC GAS HAZARDS 6 TLV of a chemical substance is a level to which it is believed a worker can be exposed day after day for a working lifetime without adverse health effects. The measurements most commonly used for concentrations of Toxic Gas levels are Parts per million (PPM) and Parts per Billion (PPB) Typical Semiconductor Industry standards for Toxic Gas Monitoring would be to set Alarm Level 1 at ½ TLV and Alarm Level 2 at TLV. TGM Level 1 Alarms Notify occupants of the potential hazard. TGM Level 2 Alarms close HPM control valves and Notify Monitoring stations for response. (ACGIH) publishes Threshold Limit Values & Biological Exposure Indices. TLVs and BEIs

ASPHYXIANT HAZARD 7 Oxygen deficiency is another of the hazards that is present in manufacturing, air is made up of several different gases including oxygen. Normal ambient air contains an oxygen concentration of 20.9%. When oxygen levels are below 19.5% the air is considered oxygen deficient, and below 16% it is considered unsafe for humans. Health Effects 15%-19% Reduced intellectual & physical performance, reduced coordination, and increased breathing rate. 12%-15% Poor judgement, abnormal fatigue, emotionally upset. <10% Inability to move, fainting, almost immediate loss of consciousness, convulsions followed by death. <6% Convulsions, shortness of breath, cardiac standstill, death in minutes. <4% Unconsciousness after one or two breaths.

PYROPHORIC GAS HAZARDS 8 Pyrophoric Gas According to OSHA, pyrophoric means a chemical that will ignite spontaneously in air at a temperature of 130 degrees Fahrenheit (54.4 degrees C) or below. Image of a Silane Release and Explosion at a Photovoltaic Fab, 1 Fatality.

MORE GAS DETECTION TERMS 9 PEL Permissible Exposure Limit 8 hour time weighted average of an airborne concentration of a substance and represents conditions in which all workers may be exposed to for 8 hours per day. Established by OSHA Most TLV s and PEL s are the same New Arsine TLV established of 5ppb on Jan 1, 2007 Arsine PEL 50ppb STEL Short Term Exposure Limit 15 minute time weighted average exposure that should not be exceeded at any time during a work day even is the 8 hour TWA average is within the TLV or PEL. IDLH Immediately Dangerous to Life and Health Maximum airborne concentration in which a person could escape within 30 minutes without any escape impairing symptoms or irreversible health effects. This is does not represent a safe level of exposure TWA Time Weighted Average is used to calculate a workers daily exposure to a hazardous substance or agent, averaged to an 8-hour workday. This is a guideline to determine PEL s.

PRIMARY TOXIC GAS MONITORING CODE REQUIREMENTS 10 IBC - 415.11.3 Service corridors. Service corridors within a Group H-5 occupancy shall comply with Sections 415.11.3.1 through 415.11.3.4. IBC - 415.11.3.1 Use conditions. Service corridors shall be separated from corridors as required by Section 415.11.1.2. Service corridors shall not be used as a required corridor. IBC - 415.11.3.2 Mechanical ventilation. Service corridors shall be mechanically ventilated as required by Section 415.11.1.6 or at not less than six air changes per hour. IBC - 415.11.3.5 Emergency alarm system. Emergency alarm systems shall be provided in accordance with this section and Sections 415.5.1 and 415.5.2. The maximum allowable quantity per control area provisions shall not apply to emergency alarm systems required for HPM. IBC - 415.11.3.5.4 Alarm-initiating devices. An approved emergency telephone system, local alarm manual pull stations, or other approved alarm-initiating devices are allowed to be used as emergency alarm-initiating devices. IBC - 415.11.3.5.5 Alarm signals. Activation of the emergency alarm system shall sound a local alarm and transmit a signal to the emergency control station. IBC - 415.11.4 Storage of hazardous production materials. Storage of hazardous production materials (HPM) in fabrication areas shall be within approved or listed storage cabinets or gas cabinets or within a workstation. The storage of HPM in quantities greater than those listed in Section 5004.2 of the International Fire Code shall be in liquid storage rooms, HPM rooms or gas rooms as appropriate for the materials stored. The storage of other hazardous materials shall be in accordance with other applicable provisions of this code and the International Fire Code.

PRIMARY TOXIC GAS MONITORING CODE REQUIREMENTS 11 IFC 2703.13 Continuous Gas Detection System. A continuous gas detection system shall be provided for HPM gases where the physiological warning threshold level of the gas is at a higher level than the accepted permissible exposure limit (PEL) for the gas and for flammable gases in accordance with Sections 2703.13.1 and 2703.13.2.2. IFC - 2703.13.1 Where required. A continuous gas detection system shall be provided in the areas identified in Sections 2703.13.1.1 through 2703.13.1.4 IFC - 2703.13.1.1 Fabrication areas. A continuous gas detection system shall be provided in fabrication areas where gas is used in the fabrication area IFC - 2703.13.1.2 HPM rooms. A continuous gas detection system shall be provided in HPM rooms where gas is used in the room. IFC - 2703.13.1.3 Gas cabinets, exhausted enclosures and gas rooms. A continuous gas detection system shall be provided in gas cabinets and exhausted enclosures. A continuous gas detection system shall be provided in gas rooms where gases are not located in gas cabinets or exhausted enclosures. IFC - 2703.13.1.4 Corridors. Where gases are transported in piping placed within the space defined by the walls of a corridor and the floor or roof above the corridor, a continuous gas detection system shall be provided where piping is located and in the corridor. Exception: A continuous gas detection system is not required for occasional transverse crossings of the corridors by supply piping that is enclosed in a ferrous pipe or tube for the width of the corridor.

PRIMARY TOXIC GAS MONITORING CODE REQUIREMENTS IFC 2703.13.2 Gas detection system operation. The continuous gas detection system shall be capable of monitoring the room, area or equipment in which the gas is located at or below all the following gas concentrations: 1. Immediately dangerous to life and health (IDLH) values where the monitoring point is within an exhausted enclosure, ventilated enclosure or gas cabinet. 2. Permissible exposure limit (PEL) levels where the monitoring point is in an area outside an exhausted enclosure, ventilated enclosure or gas cabinet. 3. For flammable gases, the monitoring detection threshold level shall be vapor concentrations in excess of 25 percent of the lower flammable limit (LFL) where the monitoring is within or outside an exhausted enclosure, ventilated enclosure or gas cabinet. 4. Except as noted in this section, monitoring for highly toxic and toxic gases shall also comply with Chapter 60 of the International Fire Code. IFC - 2703.13.2.1 Alarms. The gas detection system shall initiate a local alarm and transmit a signal to the emergency control station when a short-term hazard condition is detected. The alarm shall be both visual and audible and shall provide warning both inside and outside the area where the gas is detected. The audible alarm shall be distinct from all other alarms. IFC - 2703.13.2.2 Shutoff of gas supply. The gas detection system shall automatically close the shutoff valve at the source on gas supply piping and tubing related to the system being monitored for which gas is detected when a short-term hazard condition is detected. Automatic closure of shutoff valves shall comply with the following: 1. Where the gas detection sampling point initiating the gas detection system alarm is within a gas cabinet or exhausted enclosure, the shutoff valve in the gas cabinet or exhausted enclosure for the specific gas detected shall automatically close. 2. Where the gas detection sampling point initiating the gas detection system alarm is within a room and compressed gas containers are not in gas cabinets or an exhausted enclosure, the shutoff valves on all gas lines for the specific gas detected shall automatically close. 3. Where the gas detection sampling point initiating the gas detection system alarm is within a piping distribution manifold enclosure, the shutoff valve supplying the manifold for the compressed gas container of the specific gas detected shall automatically close. 12

PRIMARY TOXIC GAS MONITORING CODE REQUIREMENTS 13 IFC 2703.1 Emergency control station. An emergency control station shall be provided in accordance with Sections 2703.1.1 through 2703.1.3. IFC - 2703.1.1 Location. The emergency control station shall be located on the premises at an approved location outside the fabrication area. IFC - 2703.1.2 Staffing. Trained personnel shall continuously staff the emergency control station. IFC - 2703.1.3 Signals. The emergency control station shall receive signals from emergency equipment and alarm and detection systems. Such emergency equipment and alarm and detection systems shall include, but not be limited to, the following where such equipment or systems are required to be provided either in this chapter or elsewhere in this code: 1. Automatic sprinkler system alarm and monitoring systems. 2. Manual fire alarm systems. 3. Emergency alarm systems. 4. Continuous gas detection systems. 5. Smoke detection systems. 6. Emergency power system. 7. Automatic detection and alarm systems for pyrophoric liquids and Class 3 water-reactive liquids required in Section 2705.2.3.4 of the International Fire Code. 8. Exhaust ventilation flow alarm devices for pyrophoric liquids and Class 3 water-reactive liquids cabinet exhaust ventilation systems required in Section 2705.2.3.4 of the International Fire Code.

HPM TRANSPORTATION CORRIDOR 14 IBC - 415.11.3 Service corridors. Service corridors within a Group H-5 occupancy shall comply with Sections 415.11.3.1 through 415.11.3.4. IBC - 415.11.3.1 Use conditions. Service corridors shall be separated from corridors as required by Section 415.11.1.2. Service corridors shall not be used as a required corridor. IBC - 415.11.3.2 Mechanical ventilation. Service corridors shall be mechanically ventilated as required by Section 415.11.1.6 or at not less than six air changes per hour. IBC - 415.11.3.5 Emergency alarm system. Emergency alarm systems shall be provided in accordance with this section and Sections 415.5.1 and 415.5.2. The maximum allowable quantity per control area provisions shall not apply to emergency alarm systems required for HPM. IBC - 415.11.3.5.4 Alarm-initiating devices. An approved emergency telephone system, local alarm manual pull stations, or other approved alarm-initiating devices are allowed to be used as emergency alarminitiating devices. IBC - 415.11.3.5.5 Alarm signals. Activation of the emergency alarm system shall sound a local alarm and transmit a signal to the emergency control station. Notification Phone Pull Station

STORAGE OF HAZARDOUS PRODUCTION MATERIALS HPM STORAGE ROOM 15 IBC - 415.11.4 Storage of hazardous production materials. Storage of hazardous production materials (HPM) in fabrication areas shall be within approved or listed storage cabinets or gas cabinets or within a workstation. The storage of HPM in quantities greater than those listed in Section 5004.2 of the International Fire Code shall be in liquid storage rooms, HPM rooms or gas rooms as appropriate for the materials stored. The storage of other hazardous materials shall be in accordance with other applicable provisions of this code and the International Fire Code TGM DETECTION ACCESS CONTROL HVAC SHUTDOWN HPM ROOM ALARMS STAGING CABINETS

LIFE SAFETY CONTROL DESK 16 IFC - 2703.1.3 Signals. The emergency control station shall receive signals from emergency equipment and alarm and detection systems. Such emergency equipment and alarm and detection systems shall include, but not be limited to, the following where such equipment or systems are required to be provided either in this chapter or elsewhere in this code: 1.Automatic sprinkler system alarm and monitoring systems. 2.Manual fire alarm systems. 3.Emergency alarm systems. 4.Continuous gas detection systems. 5.Smoke detection systems. 6.Emergency power system. 7.Automatic detection and alarm systems for pyrophoric liquids and Class 3 water-reactive liquids required in Section 2705.2.3.4 of the International Fire Code. 8.Exhaust ventilation flow alarm devices for pyrophoric liquids and Class 3 water-reactive liquids cabinet exhaust ventilation systems required in Section 2705.2.3.4 of the International Fire Code.

TOXIC GAS DISTRIBUTION AND TGM INTERFACE 17

TOXIC GAS DETECTED IN THE TOOL EXHAUST 18

TOXIC GAS DETECTED IN THE VMB EXHAUST 19

TOXIC GAS DETECTED IN THE GAS CABINET EXHAUST 20

TOXIC GAS MONITORING FOR TOOL S WITH ONBOARD GAS BOTTLES 21

HPM WORK BENCHES 22

TOXIC GAS MONITORING BLOCK DIAGRAM 23

TOXIC GAS MONITORING SYSTEM OVERVIEW TOXIC GAS MONITORING SYSTEM PLC Gas Cabinet Chemcassette Ethernet IP (Redundant) Discrete I/O Toxic Gas Evacuation Alarm Zone Ethernet IP (Redundant) 24 TGM Manual Pull Tool CO2 Fire Suppression Discrete I/O Discrete I/O Discrete I/O Valve Manifold Box FTIR Discrete I/O 24VDC 4-20mA Fault Signal Discrete I/O Electrochemical/Single Point PLC Specifications: Redundant Power Supplies Redundant CPU s Redundant Communication Tool TCP/IP Fire Alarm System Control Room SCADA

SEMICONDUCTOR TOXIC GAS MONITORING SYSTEM SIZE 25 PLC MAIN CONTROL PANELS ~ 4 PLC REMOTE INPUT/OUT PANELS ~ 60 TOXIC GAS MONITORING FTIR AND CHEMCASSETTE DETECTORS~ 50 SINGLE POINT DETECTORS ~ 1200 TOXIC GAS MONITORING DETECTION POINTS ~ 3500 DISCRETE I/O POINTS ~ 8500

DETECTOR TECHNOLOGY 26 GAS TYPES HOT WIRE CATALYTIC BEAD ELECTRO- CHEMICAL (EC CELL) PYROLYZER /EC CELL COLORIMETRIC TECHNOLOGY CHEMCASSETTE SOLID STATE SENSORS GALVANIC SENSORS FOURIER TRANSFORM INFRARED SPECTROMETER (FTIR) HYDRIDES X(3) X X MINERAL ACIDS X X X AMMONIA X(1) X X OXIDIZERS X X OZONE X X(4) X COMBUSTIBLES X X X NITROGEN TRIFLUORIDE X X(4) X(4) OXYGEN X FREON X(2) X(2) X(2) ALIPHATIC, HALOGENATED HYDROCARBONS X 1- Combustible Levels 2- Freon Dependent 3- Not Available with new Arsine TLV 4- Cross Interferences to Freon's

CHEMICAL IMPREGANTED TAPE DETECTORS Chemcassette Detectors are widely used in the Semiconductor industry and are the primary detection method used when detecting for the following gas families: OXIDIZERS FLUORINE CHORINE HYDRIDES MINERAL ACID 27

FOURIER TRANSFORM INFRARED SPECTROSCOPE Can monitor multiple gases with a single detection tube. Lower detectable limits for some gases has been an issue meeting code required set points. Sequential monitoring per point: Longer to cycle time to get through all the points depending on how many gases each sample point is monitoring for. 28

SINGLE POINT MONITORS PRIMARY USED TO DETECT: LEL - LOWER EXPLOSIVE LIMIT DETECTION Si2H6 - DISILANE 03 - OZONE 02- OXYGEN NF3/W PYROLYZER - NITROGENTRIFLOURIDE NH3 AMMONIA Great flexibility for installs Susceptible to cross detections 29

CONCLUSION 30