LASER SOLUTIONS. Ensure Accurate Setup from Simulation to Treatment. FIXED: Micro // MOVABLE: CT Sim+

Similar documents
PROFILER Family IC PROFILER, IC PROFILER - MR & SRS PROFILER. Your Most Valuable QA and Dosimetry Tools

MapCHECK 3. The New Benchmark for 2D IMRT QA. Your Most Valuable QA and Dosimetry Tools

FX150 OTDR. Platform Highlights. Key Features

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces

It only takes an. instant to go DR. DR Retrofit: no limits to retrofitting your X-ray department with DR AED detectors

VISION V. affordable high performance

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

Modular Circular Polarimeters

Apollo Intelligent Auto Aligning Beam Detector. User Guide

An investigation of the reproducibility and usefulness of automatic couch motion in complex radiation therapy techniques

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Cemar Electro Inc. MAXX-606/607 Patient Positioning Laser. Installation and Set-up Manual

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

M210 Multifunction Micro OTDR

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

Modular Circular Polarimeters

Competency: Critically evaluate the function of the ionisation chamber in the Linear Accelerator and its importance for correct treatment delivery

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

Copyright 2017 by Lasermate Group, Inc.. All rights reserved.

OPX-BOX. Platform Highlights. Software Support. Key Features

Philips DXR Portfolio. Natalie Morgan DXR 27 th April 2015

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

M210 Multifunction Micro OTDR

AeroDR X30. Digital Mobile X-ray System

Model S FT-IR SPECTROMETER

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

Noyes OFL 250B Specs Provided by

Mastering challenges. Opening communication channels. Redefining flexibility. R100 Series Small Photoelectric Sensors

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

Motorised Infrared Optical Beam Smoke Detector. User Guide

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Now Compa ble With. VL Touchscreen Alarm. Crafted Touchscreen Security System that Revolutionizes Your World. illi tl C

Diode-Pumped Solid-State Blue Lasers

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

AV6416 OTDR. Product Overview: Main Features:

Class 1 laser beam sensor safe for your eyes

Product Specifications

The Viva-ProE System

Independent validation of machine performance check for the Halcyon and TrueBeam linacs for daily quality assurance

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

Class 1 laser beam sensor safe for your eyes

OPX-350 Series. Fiberizer Cloud. Universal Performer for Fiber Testing. Add value with. Test and Measurement in Fiber Optics

Instruction Manual. Self-Leveling Laser Level Model No

Touch Solutions for Medical and Healthcare Applications

OPX-BOXe Rugged, Pocket-sized Mini OTDR

Efficiency at Hand. Digital Radiography GF50 Series CT-GF EN. Tube 300kHU (210kJ) 150kHU (105kJ)

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

M700-Series Multifunction OTDR

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

qube mini Overview

QUICK BGA2015. Precision BGA Rework System. Features:

MRI Monitor. All-in-one monitor for the MRI environment. Features. Parameters. Accessories

FIRERAY 5000 range USER GUIDE

200mW Red Crane Warning Laser - Red Pedestrian Safety Laser - Projects Red Line on Floor - 250V DC

CLEAN-LASERSYSTEME GMBH

Motorised Infrared Optical Beam Smoke Detector. User Guide

PSA Series. Particle Size Analyzer

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

200mW Red Crane Warning Laser - Red Pedestrian Safety Laser - Projects Red Line on Floor - 120V

SURGICAL LIGHTS. Gleamer Exam Lights EQUIPMENT SURGICAL

Reliable Detection of Transparent Objects

Laser Collimated Beam Sensor

FLX380-30x FlexTester OTDR

5mW Red Crane Warning Laser - Red Pedestrian Safety Laser - Projects Red Line on Floor - IP54

FTS500 Series. Handheld OTDR Test Set.

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

THE GOLD STANDARD FOR MRI SAFETY

FTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION

The focused solution for YAG laser procedures

More Precision. thicknesssensor // The sensor for precise thickness measurements

Measuring Couch Motion Accuracy with X-ray Beam Fluence

CARESTREAM DRX-Mobile Retrofit Kit

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

Doc. No. SP R0. CXI Reference Laser. Prepared by: Jean-Charles Castagna Signature Date Design Engineer

Make critical-care decisions with fast, accurate results.

Dosimeters/Survey meters

50mW Red Crane Warning Laser - Red Pedestrian Safety Laser - 120/277V AC - IP54 Rated

S ATION EWORK ST BGA R

WHAT IS LASER ULTRASONIC TESTING?

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

Class 1 laser beam sensor safe for your eyes

Advanced Laser Material Processing Solutions

Product Specification

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

HydroFlex 3-in-1 microplate strip washing. Flexible and reliable microplate strip washing and vacuum filtration in a compact, modular platform

MEDICAL CHILLER SYSTEMS

MicrOTDR. Optical Fault Locator. User Manual

M210 Multifunction Micro OTDR

MEDICAL. Vital Monitoring, Imaging, Respiratory. Relays, Switches, Sensors and Connectors

TECHNICAL FILE LEVELS AND MULTI-FUNCTION DETECTORS

ROTOSCAN RS4 Safety Laser Scanner The flexible multitalent for people protection and versatile measuring tasks

Laser Automation &Safety. ME 677: Laser Material Processing Instructor: Ramesh Singh 1

ELISA NIMBUS. Automated ELISA Processing System

SureSigns VS4. Vital Signs Monitor Technical Data Sheet

FTB/FTBx-740C-CWDM Tunable OTDR 18-WAVELENGTH CWDM OTDR FOR METRO ETHERNET AND C-RAN LINK CHARACTERIZATION

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Sencorp Inc. introduces a bold step forward in thermoforming technology. The GEN II. Thermoformer includes the following standard features:

Transcription:

LASER SOLUTIONS Ensure Accurate Setup from Simulation to Treatment These products are available through: JRT Associates FIXED: Micro // MOVABLE: CT Sim+ 800-221-0111

Complete patient marking and alignment solutions from Simulation to Treatment Lasers are more than a fine point of light. Lasers are an integral part of your overall workflow of patient care. Choose from Red, Green or Blue to meet your needs. CT Sim+ Movable Lasers Enabling an easier patient marking workflow in the CT Simulation room Micro Fixed Lasers Supporting effective alignment for diagnostic imaging and radiotherapy treatment Micro Fixed Lasers CT Sim+ Movable Lasers SUN NUCLEAR CORPORATION // sunnuclear.com 3

Laser Solutions // CT-Sim+ Movable Lasers + CT SIM with RapidSim Software A new standard for 3 and 5 arm movable lasers powered by the Complete Connectivity Suite. THREE LASER WAVELENGTH OPTIONS RED BLUE GREEN Complete Connectivity Suite Touchscreen Control Monitor Controls all aspects of the lasers for patient marking Automated one touch patient setup No need for space-consuming keyboard or mouse controls Choose from bright or dark display options to reduce eye strain and effect of bright light sources in the imaging room Handheld Wireless Pendant Complete control from the palm of your hand Wireless functionality for freedom and workflow efficiency DICOM / Text Complies with DICOM radiation oncology standards Works with Varian, Siemens, Elekta, Philips, GE, Toshiba 4 SUN NUCLEAR CORPORATION // sunnuclear.com

CT Sim+ with RapidSim interface is the next generation in movable lasers and multiple isocenter marking, and is designed with versatility and modern workflows in mind. RapidSim includes our Complete Connectivity Suite to empower your workflow and is included standard with every system. You can also Laser Output Power (mw): <1.0 Range (m): Up to 6 Line Width: Line Length: select from blue, green or red laser colors with no additional upcharge! Highlights The Complete Connectivity Suite includes -- Handheld Wireless Pendant for in-room control -- Touchscreen Control Monitor for convenient patient workflow -- DICOM interconnectivity -- Text file interconnectivity Drift: 1 mm @ 4 m 2 meter @ 4 m No measurable drift Wavelength Red (nm): 635 Wavelength Green (nm): 515 Wavelength Blue (nm): 450 Laser Beam Adjustment Length of travel: 70 cm Accuracy of travel: ±0.5 mm at 3.0 m Positioning accuracy: ±0.5 mm at 3.0 m Laser Dimensions Length (cm): 112 Blue, Red or Green light Width (cm): 21 Multiple Installation Configurations Depth (cm): 9 Sub-millimeter accuracy with zero drift -- Wall / Ceiling -- Stanchion -- Floor Mount Post Configurations Stanchion Width (m): Customizable to 5.4 Power Requirements Voltage: 110/240 VAC (auto-select) Connectivity 3-Arm Systems Wifi: 802.11 b/g/n Any coordinate can be achieved using the CT Sim+ Movable Lasers and the CT couch Y-axis adjustment. All vital functions of the CT Sim+ system can be controlled by the master controller in the control room or from the wireless pendant at the scanner. Certifications Complies with Center for Devices and Radiological Health regulations for Class II lasers and all CE requirements. (21 CFR 1040) (IEC 60825-1) (MDD 93/42/EEC) 5-Arm Systems Any coordinate can be achieved without the need to manually change the Y-axis of the couch. CT Sim+ reads treatment planning and other simulation system coordinates for easy and accurate movement to the marked location. SUN NUCLEAR CORPORATION // sunnuclear.com 5

Laser Solutions // Micro Fixed Lasers MICRO LINAC & MR An intelligent choice for fixed lasers. THREE LASER WAVELENGTH OPTIONS RED BLUE GREEN 6 SUN NUCLEAR CORPORATION // sunnuclear.com

Laser Output Micro s composite housing and aesthetically pleasing design fit right in with your treatment room Power (mw): <1.0 appearance. The non-metallic housing cover keeps the weight of the entire unit below 800 grams, and MR compliant. Micro comes with a choice of either Red, Green or Blue colors to allow maximum flexibility. Range (m): Up to 6 Line Width: Line Length: Drift: Highlights Sub-millimeter accuracy with no measurable drift Bright and crisp light in saggital or crosshair projections MR compatible1,2 2 meter @ 4 m No measurable drift Wavelength Red (nm): 635 Wavelength Green (nm): 515 Wavelength Blue (nm): 450 Laser Beam Adjustment Blue, Red and low wavelength Green. Coarse Planar (mm): ±7.6 horizontal and vertical Compact and lightweight Coarse Angular: ±25 horizontal - - 1.6 lbs / 0.73 kg Easy to install and maintain - - 58% smaller footprint than alternative systems 1 mm @ 4 m Fine Angular: ±3.5 horizontal and vertical Line Rotation: ±180 3 Laser Dimensions Length (mm): 146 Width (mm): 92 Depth (mm): 76 Weight (g): 725 Universal Power Supply Voltage: 110/240 VAC (auto-select) Certifications Complies with Center for Devices and Radiological Health regulations for Class II lasers and all CE requirements. (21 CFR 1040) (IEC 60825-1) (MDD 93/42/EEC) These products are available through: JRT Associates 5 Nepperhan Avenue, Suite 2B Elmsford, NY 10523 800-221-0111 1 When installed >3ft from the center of the bore 2 During imaging without the need for posts or stanchions 3 Based on total volume compared to LAP Apollo published specs SUN NUCLEAR CORPORATION // sunnuclear.com 7