Microwave Doppler Sensors Applications. for Komantech

Similar documents
ADPRO PRO Series by Xtralis

OMA-300 Process Analyzer

Pedestrian Swing and sliding doors. Accessories

SENSORS AUTOMATIC DOORS FOR PRODUCT CATALOG.

RILEVATORI DI MOVIMENTO DA INTERNO serie unum

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

Radar Sensor. Radar Security Detector Model No. : DND-30L/30W, DND-60L/60W, DND-90L/90W. Feature. Specification. Reference

K-Band Doppler Sensor Module

Product Specifications

BLIND SPOT MONITORING (BSM) SYSTEM [Except Australian specs.]

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

KingShield. - Occupancy Detectors NEW. For complete Lighting Control... ORION RANGE. P High performance for optimum switching of all types

APPLIED. OMA-406R Rackmount Process Analyzer

THE BEST SOLUTIONS FOR OUTDOOR PERIMETER PROTECTIONS

FlowJam Bulk Flow Detection

Blind Spot Detection System Owner's Manual

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D. Radar sensor

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D-NA. Radar sensor

The SharpEye 40/40I (IR3) Flame Detection

Dräger GS01 (wireless) Detection of flammable gases and vapours

Fiber Optic Cable Fence Disturbance Sensor

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

Movement-based energy control

MANUFACTURER OF PERIMETER INTRUSION DETECTION SYSTEMS FOR CRITICAL INFRASTRUCTURE AND SENSITIVE SITES

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

STANDARD FEATURES SPECIFICATIONS

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

English. Series. Installation and Use Manual

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses

FCS-320-TM Series Conventional Aspirating Smoke Detectors

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150

S P A C E D E T E C T I O N

Intrusion Outdoor Protection Perimeter

Dräger Polytron 5720 IR Toxic Gas Detection

900 ControlEdge Remote Termination Panel (RTP) For Relay Outputs

The SharpEye 40/40M (Multi IR) Flame Detection

DESIGN EASY ADJUSTMENT

COMPANY PROFILE. a A SOLID REPUTATION. a DETAIL IN MANUFACTURING PROCESS. a SICURIT A TRUSTED SUPPLIER

INTREPID Perimeter Intrusion Detection System

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Microwave Sensor. Basic Microwave Sensor. Energy Saving Motion Sensor. Introduction Features Technical Specification. 3 Dimensions

Product Specification

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Immunity. P/N: ver.b

Intrusion. Outdoor protection perimeter

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

Dräger Polytron 5720 IR Detection of carbon dioxide

2011 Door Product Brochure

Designer & Application Notes. Securtiy Termination. belfuse.com/cinch

INTREPID Buried Cable Perimeter Intrusion Detection System

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

RADAR-BASED PERIMETER PROTECTION FOR CRITICAL INFRASTRUCTURES

INTEGRATED PERIMETER SECURITY SOLUTIONS FENCE DETECTION SYSTEMS BURIED CABLE DETECTION SYSTEMS ALARM MONITORING AND CONTROL SYSTEMS MICROWAVE SENSORS

UWB Stepped-FM Sensor for Home Security

Open-area Smoke Imaging Detector. Engineering Specification

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Dräger Flame 5000 Flame Detection

Dräger Polytron 8720 IR Detection of carbon dioxide

INTREPID Buried Cable Perimeter Intrusion Detection System

SWARCO TRAFFIC SYSTEMS GMBH. TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger X-zone 5500 Area Monitoring

Dräger Polytron 5100 EC Detection of toxic gases and vapors

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

LB3-PCx50 Premium Cabinet Loudspeakers

GS01 (wireless) Detection of flammable gases and vapours

The SharpEye 40/40I (IR3) Flame Detection

1125 PIR Motion Detector

IFS Fiber Module Installation & Operation Instructions

Dräger PointGard 2100 Detection of toxic gases and vapours

sensorama sensing the future Detectors for industrial doors and gates Detectors for automatic doors

Training Gas Detection Level 3 Maintenance and Repair

Training Gas Detection Level 2 User and Calibration. Basic Information

Dräger Flame 5000 Flame Detection

Terminal Automation Solutions

SER7300 Series Installation Guide for HVAC FCU Applications

Advanced DIGITAL Wired PIR Motion Detector

Enraf Servo Gauge 854 XTG

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

Gallagher D10 Tautwire Sensors & D21 Disturbance Sensors Integration with Gallagher

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

ARCHITECTURAL DOOR HARDWARE SENSORS CATALOG

CORPORATE PROFILE PERIMETER PROTECTION SYSTEMS

Intrusion sensors. We listened to you

Dräger Pac 6000 Single-Gas Detection Device

G-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System

Report #: SML Date of Activity: 12 March 2015 Client: K40 Electronics Corporate Tested Product: K40 RLS2 K40 RLS2

Vision for Optoelectronics in the Automobile Thomas M. Forest General Motors Research & Development

PRODUCT MANUAL. AGD Systems Limited 2016 Doc. Ref. 202 PM ISS2 ISO ISO 9001 Registered Quality Management. Registered Environmental Management

STT700 Temperature Transmitter Lightning Protection Device Specifications 34-TT-03-20, June 2017

INTREPID SINGLE-PLATFORM PERIMETER INTRUSION DETECTION AND MONITORING SYSTEM

SmartLine Pressure Transmitter ST 700 Basic Quick Start Installation Guide 34-ST-25-57, Revision 1, December 2016

STEAM TRAP HEALTH MONITORING SERVICE EXECUTIVE SUMMARY

Transcription:

Microwave Doppler Sensors Applications for Komantech Empowering thru Innovation 1 December 216 @ Seoul

(Satcom & Sensor Systems) Incorporated in 1991 and headquartered in Singapore. Previously known as Agilis Communication Technologies Pte Ltd. Specializes in microwave technologies. Design and manufacture satellite communication and sensor products, and systems. A leading Doppler sensor modules supplier since 1993 (Satcom & Sensor Systems) Page 2

Microwave Doppler Transceiver Modules C-band (5.8 GHz) X- Band (1 GHz) K-Band (24 GHz) (Satcom & Sensor Systems) Page 3

C-Band (5.8 GHz) Module LB2 Bi-static Doppler transceiver. Suitable for ceiling mounted movement detection. Internal IF amplifier for better noise immunity (variant). Detection range: > 12 m diameter. Applications: occupancy sensors (Satcom & Sensor Systems) Page 4

X-Band (1 GHz) Modules North America, Australia, Asia HB1 Bi-static Doppler transceiver. 1.525 GHz. Conforms to FCC Part 15.245. Detection range: 15~25 m approx. Application: intruder alarms Normalized Radiation Pattern (db) -1-2 -3-4 -3-2 -1 18 15 21 12 9 6 X Y 3 33 24 27 3 (Satcom & Sensor Systems) Page 5

X-Band (1 GHz) Module America, Europe, Asia Pacific HB9 Series Bi-static Doppler transceiver. Conforms to FCC Part 15.245 and EN3-44. Compatible to America and Europe. Detection range: 15~2 m approx. Application: intruder alarms, door openers Normalized Radiation Pattern (db) -1-2 -3-4 -3-2 -1 18 15 21 12 9 6 X Y 3 33 24 27 3 (Satcom & Sensor Systems) Page 6

X-Band (1 GHz) Module HB17 Bi-static Doppler transceiver. Built-In low noise amplifier at Rx Conforms to FCC Part 15.245 and EN3-44. Detection range: 2~25 m approx. Application: long range intruder alarms Normalized Radiation Pattern (db) -1-2 -3-4 -3-2 -1 18 15 21 12 9 6 X Y 3 33 24 27 3 (Satcom & Sensor Systems) Page 7

X-Band (1 GHz) Module FM HB18 Bi-static Doppler transceiver. FM capable. Conforms to FCC Part 15.245 and EN3-44. Detection range: 15~2 m approx. Application: outdoor intruder alarms with ranging and direction discrimination (to eliminate nuisance form swinging plant) Normalized Radiation Pattern (db) -1-2 -3-4 -3-2 -1 18 15 21 12 9 6 X Y 3 33 24 27 3 (Satcom & Sensor Systems) Page 8

K-Band (24 GHz) Modules Universal Frequency AP Series Miniature bi-static Doppler transceiver. Conforms to FCC Part 15.245 and EN3-44. Small and low-profile design. I-Q outputs available. Detection range: 1~15 m approx. Application: intruder alarms, occupancy sensors, door openers Normalized Radiation Pattern (db) -1-2 -3-4 -3-2 -1 18 15 21 12 24 9 27 6 3 X Y 3 33 (Satcom & Sensor Systems) Page 9

K-Band (24 GHz) Modules DF Series Bi-static Doppler transceiver. Conforms to FCC Part 15.245 and EN3-44. I-Q outputs for direction discrimination. FM model available Narrow beam possible for lane discrimination. Long detection range: >15 m (for vehicle detection) Application: traffic speed detection (Satcom & Sensor Systems) Page 1

HB1/HB19 Indoor Intrusion Alarm AP96 Page 11

Indoor Long Intrusion Alarm HB17 (3% longer Range than HB19) LNA Page 12

Outdoor Intrusion Alarm HB18 (Direction decimation by FSK feature) VT Page 13

DF6 Outdoor Long Intrusion Alarm Page 14

Bi-direction/Uni-Direction Door Opener AP96: Bi-Directional AP97: Uni-Directional (save air-conditioning energy by reduce door open time by 4%) Page 15

HF Occupancy Sensor LB2 Preamp Normalized Radiation Pattern (db) -1-2 -3-4 -3-2 -1 18 15 21 12 9 6 X Y 3 33 24 27 3 AP98 LNA Page 16

HB1 Contactless Switch AP96 Page 17

Touchless Sensor HB1 AP96 Page 18

Sport Radar DF6 HB17 Page 19

AP97 Blind Spot Monitoring Area Side Mirror View Area Blind Spot/Lane Change Warning Blind Spot Page 2

AP96/AP97 Rain / Snow Detection (Intensity & Type) Page 21

Vehicle Speed Detection DF6: EN, 15~4 m DF3: FCC, High Power2 ~ 7 m Page 22

On-demand Traffic Signal Control DF6 Page 23

Radar Speed Sign / Speed Activated Message Board GS6 Vehicle Speed Detector Page 24

GS7 Vehicle Speed Detector Traffic Speed Monitoring / Law Enforcement Copyright, 22 Agilis Communication Technologies Pte Ltd

Gentry Mount Speed Detector GS7 Series Vehicle Speed Detector Rail Side Speed Detector Road Side Speed Detector & Counter Copyright, 22 Agilis Communication Technologies Pte Ltd

Disclaimer This presentation is only for educational purposes. Pease be advised that the respective trademark and copyrights remain the properties of the respective owner/s. Where possible and to the best of our knowledge, credit for the respective content is given where due. Please inform us if we have not cited or give proper credit for your content. Page 27

Thank You Empowering thru Innovation 5 December 216