Title: Heat Recovery From Milk Cooling Systems

Similar documents
Refrigeration: Reducing energy costs in dairy parlours

Module 2: Farm Practices to Improve Energy Efficiency

2018 Agricultural Programs Rebate Application Federated Rural Electric, ATTN: Jon, P.O. Box 69, Jackson, MN 56143

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

Price increases since % 38% 53% 63% 115% Ground Beef. Electricity Eggs White Bread

Reducing Energy Use in Grain Dryers

Residential Water Conservation Research Brief On-Demand Hot Water Systems

Focus on Energy Business Programs Summary of Services and Incentives July 2009

Cork County Energy Agency

You will investigate the electrical consumption in your home over the course of TWO days (48 hour period).

* Peak kw is determined by the average kw load reduction occurring between 1PM and 4PM on weekdays during June, July and August.

Farm Energy Audit Workshop

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Dairy Housing Milking Centre Design and Construction for Parlour Milking

Energy Recovery Ventilation

Reinventing Energy Efficiency WARMNESS.

SMART METERS ANSWER BOOK HOW YOU WHY ONTARIO WHAT ARE GETTING SMART ABOUT CAN START TO PREPARE NOW PAGE 6 TIME-OF-USE PRICES? PAGE 4 IS INTRODUCING

managing electricity at home atcoenergysense.com

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

ELECTRIC WATER HEATERS

Daikin Blueprint: Delivering Hot Water with a Chiller

MILK DEVELOPMENT COUNCIL

The Solar Hot-Water System

Water Heating. Types of Water Heaters It's a good idea to know the different types of water heaters available before you purchase one:

HEAT RECOVERY SOLUTION.

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

COMPANY Presentation Focus on SANDEN Environmental Solutions

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS UNIT OBJECTIVES

The Use of Evaporative Cooling Panels in Tie Stall Dairy Barns

Keep your electricity bill cool this summer

Contents. General appliance information

MVR Evaporators Reduce Plant Operation Costs

KE2 EvaporatorEfficiency Theory of Operation

Office of Energy Efficiency National Energy Use Database Energy Consumption of Major Household Appliances Marketed in Canada Trends for

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

Residential Geothermal Technology. Eco-$mart, Inc. Distributed by: TOLL FREE:(888) FAX:(941)

Heat Pump Water Heaters

YEARLY VIEW. 6/28/2016

VAPOUR RECOVERY DURING FUEL LOADING. Ben Adamson Principal Engineer Refrigeration Engineering Pty Ltd, NSW Australia

at a glance Energy FinAnswer Case Study: Albertsons Energy FinAnswer is the best-run, best-delivered program we ve been involved with.

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

Understanding Household Electricity Use

Emerging Technologies: VFDs for Condensers. Douglas T. Reindl Director, IRC University of Wisconsin-Madison. University of Wisconsin-Madison

InterNACHI Home Energy Inspection for th Street

ENERGY EFFICIENCY PROJECTS. NO-COST AND LOW-COST UPGRADES FOR YOUR FACILITY In partnership with: Refrigerating Engineers & Technicians Association

Transcritical CO2 Bottle Cooler Development

Summary of 60-Day Notice: Heating Efficiency

Outdated Publication, for historical use. CAUTION: Recommendations in this publication may be obsolete. Family Community Education.

The Innovation Center for U.S. Dairy and The USDA Natural Resources Conservation Service (NRCS)

Dimplex Electric Thermal Storage (ETS) Product Guide - Nova Scotia

Field Evaluation of Pre-Commercial Residential Gas Heat Pump Water Heaters

Midwest Industrial Initiative Webinar: Industrial Refrigeration

How Air Conditioners Work by Marshall Brain

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series

How to save money on energy at home

5. ASSESSMENT RECOMMENDATIONS

AMERICAN EQUIPMENT SYSTEMS A Division Of Trevor-Martin Corporation th Terrace North Clearwater, Florida 33762

Use words from the list to complete the following sentences. Words may be used once, more than once, or not at all.

Four of the appliances, including the fan heater, are designed to transform electrical energy into heat.

MILK PRODUCER PLAN REQUIREMENTS Rev. 02/2018

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

The (Hot) Water Efficient Commercial Kitchen. Charles M. Bohlig East Bay Municipal Utility District

In your home. l Regularly clean the dust off your light fixtures, lamps, bulbs, tube lights and fans.

HEAT RECOVERY WITH AERZEN TURBOS, BLOWERS AND COMPRESSORS. Reduce costs for compressed air generation

ORB ORB. Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

save I have the power to A helpful guide to making your home wattsmart _RMP_wattsmart Handbook_Resize_5.5x7.75_F2.indd 1

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

Cool Savings Program Report

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

Due: in lecture Friday, September 23 rd Attach your Baseline data

Management of In-Bin Natural Air Grain Drying Systems to Minimize Energy Cost

<<Date>> <<Recipient>> <<Address>>

about your house Choosing a Dehumidifier

Air-Conditioning Buying Guide

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems

ACT - VS ULTIMATE ENERGY SAVING TECHNOLOGY NEW - ENERGY SAVING VARIABLE SPEED DRYERS BY FRIULAIR

next generation R 1 cycling refrigerated compressed air dryers flow capacity: scfm ( Nm 3 /hr)

PREMIER SERIES APARTMENT HOUSE SIZING

Save up to 78%* of your hot water energy costs... rain, hail or shine!

Energy Benefits of Pulsation Stop Control on Dairy Farms

HI-EDRY HI-EDRY THE HIGH-EFFICIENCY DEHUMIDIFIERS. Therma-Stor Products THE HIGH-EFFICIENCY DEHUMIDIFIER. a division of DEC International, Inc.

- Essay Control Functions and Benefits

SUMMARY OF SERVICES & INCENTIVES

High Profile Evaporator

Hot Water. The Efficiency Challenge!

DAVE DEMMA REDUCING ELECTRICAL CONSUMPTION

Geothermal Heating and Cooling Using Ground Source Heat Pumps. Prepared by: Steven Forrester, P.E. Principal

This presentation is posted for public use. ACEEE does not endorse any product or service.

PROVIDING GROWTH TO RESEARCH.

SERVICE ASSISTANT OVERVIEW FDSI Online Training

THERMAL ICE STORAGE: Application & Design Guide

WATER WISE SURV EY. Santa Barbara City College

Hybrid Refrigerated/Desiccant Compressed Air Dryers

DAVE DEMMA ACHIEVING HEAD PRESSURE CONTROL

Dairy Housing Manure Handling Options for Robotic Milking Barns H. House, P.Eng.

Sustainable Techniques in Refrigerated Space

Transcription:

Agdex#: 410/717 Publication Date: 02/88 Order#: 88-032 Last Reviewed: 09/96 Title: Heat Recovery From Milk Cooling Systems Division: History: Agriculture and Rural Replaces Factsheet #82-065, "Heat Recovery from Milking Cooling Written by: R.G. Winfield - Energy Engineer, Agricultural Energy Centre Table of Contents 1. Introduction 2. Milk Cooling 3. Heat Recovery 4. Water Temperature 5. Preheated Water Usage 6. Estimating Present Hot Water Usage 7. Heat Recovery systems 8. Economics 9. Summary Introduction Heat energy is removed from milk during cooling. The heat energy can be 'dumped' from an air-cooled condenser, or all/ or part of it can be transferred to water using a water-cooled condensing mechanism or a milk precooler. Water-cooled condensers and milk precoolers will reduce compressor running time. However, the greater energy (and dollar) savings usually come from displacing water heating energy costs. On most dairy farms the milk heat available can preheat more water than is required for nominal wash-up and sanitizing. The problem then is one of choosing a 'heat recovery system' that will provide only the warmed water needed on an individual farm -- with a reasonable payback. Milk Cooling To maintain milk quality, milk must be cooled from about 39 C (cow body temperature) to 3 C for safe storage. Milk is http://www.p2pays.org/ref/09/08509.htm (1 of 8)5/1/2007 2:02:08 PM

normally cooled by a refrigeration unit acting as a heat pump moving heat from a source (the milk) to a sink (air or water) using a carrier called a refrigerant (Freon gas). When the refrigerant changes state from a liquid to a gas in the evaporator (bulk milk tank) it absorbs heat from the milk. The compressor pressurizes the gaseous refrigerant. Under pressure the hot refrigerant will give up heat and revert to a liquid. The condenser provides a means for this heat to be removed. The heat can be released to the air within the milkhouse (or directed outside) or can be released to water depending on the type of condenser in place. The liquefied refrigerant then passes through an expansion valve mechanism causing a pressure drop. The refrigerant is now ready to absorb heat again. Figure 1. Refrigeration unit schematic. http://www.p2pays.org/ref/09/08509.htm (2 of 8)5/1/2007 2:02:08 PM

Heat Recovery Heat recovery systems do not change the basic refrigeration cycle. They simply change the type or combination of condenser(s) used to remove heat from the refrigerant. Water-cooled condenser units can put all the heat from the refrigerant, which will include some of the compressor input energy, into water. This type of unit is efficient and generates about one litre of preheated water for every litre of milk cooled. This is often a much greater quantity of water than can be used effectively for normal wash-up and sanitizing operations in the milking area. Water Temperature The average preheated water temperature from a watercooled condensing mechanism is likely to be in the 50 to 60 C range. Starting water temperatures for milking equipment washing (sanitizing) should be 75 C. Thus all preheated water used for sanitizing must be further heated using conventional energy sources. However, many auxiliary water uses such as: cow prepping, calf feeding, employee showering, can use the preheated water without further heating. Preheated Water Usage Before investing in any type of heat recovery equipment, potential preheated water usage should be estimated. Dumping preheated water as a means of heat disposal may not be prudent - especially if potable water supply is limited. Unfortunately no reliable warm (hot) water use guidelines are available. Reported average uses vary from 4 to 14 L/cow per day, with most below 10. Except when significant warm water uses exist in addition to the normal equipment/facilities wash-up (sanitizing), it is not likely that more than one-half of the milk heat can be used effectively for water preheating. Fortunately equipment is available to permit recovery of one-half or less of the milk heat efficiently. The equipment choice will vary with the size of the refrigeration system required or in place for the specific dairy operation. Milk heat is a reliable source, occurring every time the cows are milked. It must be used as produced or stored temporarily because the milk must be cooled quickly to maintain quality standards. Thus it is not a constant source for space heating (i.e. the calf nursery) and is not required on a year round basis for that type of application. Pit floor heating with warmed water can also be installed in new milking parlors. If automatic prep stalls are used with parlors, the warmed water use rate might warrant total milk heat recovery. No common external uses are evident or economically viable at this time for most Ontario dairy operations. If energy prices increase significantly, the possibility exists to pipe preheated water to the hot water heater in the residence. Warming the swimming pool is another potential use - but it is limited to very large milking herds. Figure 2. A conventional air-cooled condensing unit and compressor discharging milk heat into air. http://www.p2pays.org/ref/09/08509.htm (3 of 8)5/1/2007 2:02:08 PM

Estimating Present Hot Water Usage By accurately estimating the quantity of hot (75 to 77 C) or warmed (50 to 60 C) water that can be used effectively, local dairy equipment suppliers should be able to recommend the most cost effective heat recovery system for individual dairy operations. If a conventional water heater is in place, a water meter in the cold supply line is the most accurate rate test. For existing electric water heaters two other estimating techniques are available. One is to install a temporary kilowatt hour meter. Energy consumption should be recorded for at least two and preferably about ten days. For heaters in cold locations providing 75 to 77 C water assume about 10 L of hot water for each kwh of energy input. Example: The electric water heater uses 360 kwh over 12 days. Average energy use rate will be 30 kwh/day. Approximate hot water usage is: 30 x 10 = 300 L/day. If a kilowatthour meter is not available, a recording amp meter or a cumulative timer attached to the water heater circuit can provide average daily water heater 'on-time'. After checking the heating element rating, Table 1 can be used to estimate the hot water use rate. Water Heater 'On Time' - Average hours/day Heating Element Ratings ** 4 6 8 10 12 - Watts - Approximate Hot Water Use - L/day * 3000 (40 gal) 120 180 240 300 360 3800 (40 gal) 150 230 300 380 460 4500 (60 gal) 180 270 360 450 540 * Based on both upper and lower elements being the same wattage with only one energized - which is the common arrangement in all newer electric water heaters. http://www.p2pays.org/ref/09/08509.htm (4 of 8)5/1/2007 2:02:08 PM

** Based on 10L/kWh which assumes a standby heat loss of approx. 33%. If testing occurs during hot weather the hot water use values can be increased by 10 to 15%. Heat Recovery Systems 1. Total water-cooled condensing systems put all of milk heat into preheating water. When used for total cooling more warmed water is produced than can be used in most dairy operations - unless employee showering or similar uses are evident. Most of these systems incorporates at least one large (450 L) uninsulated tank which permits radiant and convective heat losses between milkings. The tank(s) will also be equipped with a temperature sensitive relief valve to dump warmed water when the tank becomes full of warm water. For larger bulk tanks having two refrigeration systems, one having a water-cooled condenser will supply the often desired 50% of milk heat for preheating water. The second one can be a conventional air-cooled unit providing desired milk room/parlor heating directly during the colder winter months. Figure 3. A complete water-cooled condensing unit putting the milk heat into water in the large vertical tank. A conventional water heater for 'topping up' is located in the adjacent service room. 2. Add-on recovery units can be connected to existing or new air-cooled systems. The units are often referred to as 'desuperheaters'. When connected into the refrigerant line between the compressor(s) and the air-cooled condenser(s), they utilize the 'superheat' of the compressed gaseous refrigerant. They effectively scalp heat and depend on the aircooled condenser(s) to remove the residual heat from the refrigerant. Add-on units have a fixed volume of water to preheat commonly in the 190 to 450 L range. The tank can be an integral pan of the desuperheater or separate - depending on the manufacturer. The integral units are insulated to minimize radiant heat loses as heat dumping is not required and the aircooled condenser(s) will provide the desired space heating in cold weather. http://www.p2pays.org/ref/09/08509.htm (5 of 8)5/1/2007 2:02:08 PM

Add-on desuperheaters can have refrigerant connections for one or two refrigeration systems. This makes this type of system very flexible in providing the quantity of preheated water than can be utilized and in permitting retrofit if needs change. Some add-on units have provision for 'topping up' the temperature of a portion of stored water volume for sanitizing purposes by including an electrical heating element. This feature can make a separate water heater unnecessary. Figure 4. The add-on 'desuperheater' (right) with integral water storage supplies preheated water to the conventional water heater (left). Note the two refrigerant lines at tope of 'desuperheater' unit. 3. Precoolers are an entirely different type of heat recovery system. They are not connected to the refrigeration system. They are heat exchangers which permit milk to be partially cooled by water prior to entering the bulk milk tank. The higher the cold incoming water flow rate the more effective the precooling of the milk. While the water to milk flow rate ratio can vary, the water must flow during the milking periods. For many dairy operations this tends to limit the potential uses of a relatively large volume of water especially when the common water to milk flow rate ratio is one or higher. Precoolers may improve milk quality by reducing blend temperatures and/or milk cooling time if an existing refrigeration system is undersized/overloaded. Economics The economic attractiveness of heat recovery from milk must be based primarily on purchased energy displacement for http://www.p2pays.org/ref/09/08509.htm (6 of 8)5/1/2007 2:02:08 PM

water heating. While water-cooled condensers, desuperheaters and precoolers will reduce compressor running time, the resultant energy savings are not well documented. Properly sized and well maintained conventional aircooled condensers systems are generally doing an adequate job of lowering milk temperature quickly enough to maintain quality standards. However, when refrigeration system changes or upgrades are required heat recovery systems should be considered to reduce water heating costs. Figure 5. Potential energy (dollar) savings by transferring milk heat to water - based on daily milk production and warmed water usage. Figure 5 illustrates by examples the range of opportunity for capital recovery of heat recovery equipment for most dairy operations in Ontario. Example "A" is for a common (35 milking cow) dairy unit producing 750 L of milk a day and using hot water at the rate of 250 L/d (7 L/cow/d). Only 33% of the milk heat can be used to preheat that amount of hot water. With electricity costing $0.05/kWh as the water heating alternative energy the annual savings potential is $210. The present cost for a small (190 L) add-on 'desuperheater' would be about $1400. Thus the capital cost recovery is not particularly attractive at approximately seven years simple payback without interest. The additional heating of all the water used for sanitizing in this example is approximately 50% of previous water heating costs. In contrast, a much larger dairy operation, Example "B" producing 2150 L of milk a day and having a high percentage http://www.p2pays.org/ref/09/08509.htm (7 of 8)5/1/2007 2:02:08 PM

(70%) warm water to milk usage, has an excellent opportunity to benefit from milk heat recovery. With electrical water heating energy at $0.05/kWh the annual savings potential is $1300. This would permit an expenditure of $3900 for heat recovery equipment and provide simple payback in three years. A significant portion of the warmed (50 C) water could be used directly in this operation for showering, facility washdown etc. Summary 1. Heat recovery from milk by water-cooled condensing mechanisms is effective and provides a reliable source of heat for preheating water. 2. If more preheated or warmed water is produced than can be used effectively, energy savings should not be claimed for that portion. 3. Water heated to 50 or even 60 C is not hot enough for dairy equipment washing (sanitizing). The starting temperature should be 75 C. 4. The quantity of water held at 75 C should be kept to the minimum required for individual sanitizing events to minimize 'stand by' heat losses. 5. The water heater receiving water from a heat recovery system should be well insulated and located in a warm utility room if possible. A 24-hour time clock can be used on the water heater to control electrical demand and limit the time 75 C water is held. The water heater can be 'offline' during milking period when demand peaks and 'online' two to three hours before line and/or tank wash. (Demand is only of concern to those paying a demand charge to the Utility.) 6. Pipeline and tank wash timer controls should be checked periodically to insure that excess quantities of hot water are not being used unnecessarily. References Winfield, R.G. and W.A. Gee, 1983. Energy recovery from milk - Can the heat be used effectively? Report for the Agricultural Energy Centre, Ontario Ministries of Agriculture and Food and Energy. Mastitis control and prevention committee, 1982. Guidelines for the installation and operation of milking and milk handling equipment. Special report, Animal Production Division, Agriculture Canada, Ottawa, Ontario, KIA 0C5. For more information: Toll Free: 1-877-424-1300 Local: (519) 826-4047 Email: ag.info@omafra.gov.on.ca This information is provided as a public service, but we cannot guarantee that the information is current or accurate. Readers should verify the information before acting on it. Feedback and technical inquiries to: ag.info@omafra.gov.on.ca Queen's Printer for Ontario http://www.p2pays.org/ref/09/08509.htm (8 of 8)5/1/2007 2:02:08 PM