LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies HVAC Products

Similar documents
Oil Burner Controls LOA3... Building Technologies HVAC Products

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

Oil Burner Controls LOA3... Building Technologies Division

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

Oil Burner Controls LMO24... LMO44...

Oil Burner Controls LMO24... LMO44...

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

LGA... Gas Burner Controls. Building Technologies Division

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

Burner controls. Building Technologies HVAC Products

Burner Controls. Building Technologies HVAC Products

Gas Burner Controls. Building Technologies HVAC Products

Use. The burner controls are certified to EN 230 and EN 298.

Use. Burner controls for use with forced draught gas or gas / oil burners of small to medium capacity in intermittent operation.

Flame Safeguards LFE10. Building Technologies HVAC Products

Flame Safeguards LFE10. Building Technologies HVAC Products

C Note! LGI16... Burner Controls. Building Technologies

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

Infrared Flame Detectors

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

LAE10 LFE10. Use. Series 02

Infrared Flame Detectors

Flame detector. The QRA4.U is for use with the following types of burner control:

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

Flame detector. The QRA4.U is for use with the following types of burner control:

UV Flame Supervision System

RAR... Photocell Detectors. Building Technologies Division

Flame detector. Building Technologies Division Infrastructure & Cities Sector

Burner Management System

QRA10... QRA53... QRA55...

Blue-flame Detectors

Building Technologies Division

Building Technologies Division

QRA10... QRA53... QRA55...

QRA10... QRA53... QRA55...

Burner Management System

Building Technologies

Basic unit with integrated air-fuel ratio control for forced draft burners

Program module for burner control LME71.000

Burner Management System

EUROBOX SERIES TYPES CM... SM... MM...

LFL Series Burner Flame Safeguard Control

Heating Element. Building Technologies HVAC Products

Basic unit with integrated fuel-air ratio control for forced draft burners LMV Building Technologies Division

EUROFLAT SERIES TYPES C... S... M...

Basic Unit with integrated Fuel / Air Ratio Control for Forced Draft Burners LMV Building Technologies

QRA10... QRA53... QRA55...

EURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR..

Immersion Temperature Controller

EUROBOX SERIES TYPES CM...N SM...N MM...N

MICROFLAT SERIES TYPES C.../U T X

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

DKG 972. Gas Burner Safety Control. For 2-stage atmospheric gas burners

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

MANUAL OF - INSTALLATION - OPERATION - MAINTENANCE LIGHT OIL BURNERS G4 - G6 G10 - G18 SINGLE STAGE

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

Eclipse Trilogy Flame Safeguard Modulating Sequences

Forced draught gas burner

DKO 974/976 DKO 974 N/976 N. Oil Burner Safety Control

BC-R10 Series. Burner Controllers

TWO STAGE HEAVY OIL BURNERS

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

MMG Gas burner safety control

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Model 60200FR Gas Primary Control Data Sheet

Gas burner automatic safety control MMI / 811.1

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

MMI (40-34) Gas burner safty control

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

for relative humidity and temperature

Room Air Quality Sensors

BOSCH CONDENS 5000W ZSB18-2A

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Quickheat 30 weather compensated boiler control

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

PRELIMINARY EDITION

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

Operator: Save these instructions for future use!

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION

Quick Reference Guide. Application. Gas Furnaces Boilers Water Heaters Commercial Cooking. Features

24 VAC Intermittent Pilot Gas Ignition Control

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

7800 SERIES RM7840E,G,L,M Relay Module

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

Old documentation - Only for your information! Product is not available anymore!

7800 SERIES RM7888A Relay Module

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Advanced Ultraviolet Burner Controller

Transcription:

ISO 900 LOA2... LOA... Oil Burner Controls LOA2... LOA... Oil burner controls for the supervision, startup and control of single- or 2-stage forced draft oil burners in intermittent operation. Oil throughput up to 0 kg/h. The LOA2... / LOA... and this Data Sheet are intended for use by OEs which integrate the oil burner controls in their products. Use, features Use The LOA... are used for the startup, supervision and control of single- or 2-stage forced draft oil burners in intermittent operation. Yellow-burning flames are supervised with photoresistive detectors QB..., blueburning flames with blue-flame detectors QC... - Forced draft oil burners conforming to E 2 - Oil atomization burners as monoblocks conforming to E 20 General features Specific features - Undervoltage detection - Bridging contact for oil preheater (not with LOA2.A2) - Special versions including models for incinerator plant and flash-steam generators - LOA... with color LED for indicating flame strength and operation CCen 09.0.2002 HVAC Products

arning notes To avoid injury to persons, damage to property or the environment, the following warning notes should be observed! Do not open, interfere with or modify the unit! Before performing any wiring changes in the connection area of the LOA..., completely isolate the unit from the mains supply (all-polar disconnection) Ensure protection against electric shock hazard by providing adequate protection for the burner control s connection terminals Check to ensure that wiring is in an orderly state and that the wires are firmly connected Press the lockout reset button / operating button only manually (applying a force of no more than 0 ), without using any tools or pointed objects Fall or shock can adversely affect the safety functions. Such units may not be put into operation, even if they do not exhibit any damage ounting notes Ensure that the relevant national safety regulations are complied with Installation notes Installation and commissioning work must be carried out by qualified staff Do not mix up live and neutral conductors Always run high-voltage ignition cables separately while observing the greatest possible distance to the unit and to other cables Electrical connection of flame detectors It is important to achieve practically disturbance- and loss-free signal transmission: ever run the detector cable together with other cables Line capacitance reduces the magnitude of the flame signal Use a separate cable Observe the permissible lengths of the flame detector cables (refer to Data Sheets (QB...) and (QC...)) Commissioning notes Commissioning work must be carried out by qualified staff hen commissioning the plant, when carrying out maintenance work, or after longer off periods, make the following safety checks: Safety check a) Burner startup with flame detector darkened b) Burner startup with flame detector exposed to extraneous light c) Simulation of flame failure during operation. For that purpose, darken the flame detector during operation and maintain this state Anticipated response Lockout at the end of «TSA» Lockout after approx. 0 seconds epetition followed by lockout at the end of «TSA» 2/0 CCen HVAC Products 09.0.2002

Standards Conformity to EEC directives Electromagnetic compatibility EC (immunity) 9 / EEC Low-voltage directive / 2 EEC Service notes aintenance work must be carried out by qualified staff Each time a unit has been replaced, check wiring to ensure it is in an orderly state and that the wires are firmly connected; make the safety checks as indicated in «Commissioning notes» above Use the KF... test adapters for short periods of time only Disposal notes echanical design The unit contains electrical and electronic components and may not be disposed of together with household waste. Local and currently valid legislation must be observed. The housing is made of impact-proof, heat-resistant and flame-retarding plastic. The oil burner control is of plug-in design and engages audibly in its base. The housing accommodates the - thermal-electric sequence switch - flame signal amplifier with the flame relay - lockout reset button with its integrated fault indication lamp Type summary The type references given below apply to burner controls without base and without flame detector. Version Type reference Voltage (VAC) Undervoltage CE t t TSAmax. tn tn t eplacement for detection Standard version LOA2.B2 ²) 220 X x 0 --- LAI2. LOA2.B ²) 0 X x 0 --- LOA2.A2 220 X x 0 20 2 20 LAI2. LOA2.A2 220 X x 0 2 --- ith remote reset LOA2.B2 ²) 220 X x 0 --- --- facility LOA.A2 220 X x 0 --- --- For flash-steam LOA2.C2 220 X x 0 20 --- 20 LAI generators For incinerator plant LOA2.C2 ¹) 220 X --- 0 --- 2 LAB2 LOA2.C ¹) 0 X --- 0 --- 2 LOA2.A2 ¹) 220 X --- 0 --- 2 --- Legend ¹) LOA2... and LOA2... are designed for use on incinerator plant where lockout by extraneous light is not desired. These types of oil burner controls are not covered by E 20 ²) ID00 infrared flicker detectors can also be used t t tn tn t TSA Prepurge time Preignition time Long postignition time Short postignition time Interval from establishment of flame to the release of Ignition safety time /0 CCen HVAC Products 09.0.2002

Ordering Oil burner control without plug-in base refer to «Type summary» Electrical connections refer to Data Sheet 20 - Plug-in base AGK... - Cable holders AGK..., AGK, AGK... - Cable strain relief elements for AGK... Electrical connections refer to Data Sheet 20 - Plug-in base AGK - Plug-in housing AGK - Cover AGK Flame detectors - Photoresistive detectors QB... refer to Data Sheet - Blue-flame detectors QC... refer to Data Sheet Pedestal (empty housing) - To increase the overall height of the LOA...to that of the LAI... / LAB... emote reset module - For use with the LOA2... / LOA... printed circuit board versions Adapter - For replacing LAB... / LAI... by LOA... - o rewiring of plug-in base required AGK2 AK2A2 KF9 Demo case - For showing the functioning of burner controls - efer to Operating Instructions B99 Test case, for making functional tests - For testing burner controls - efer to Operating Instructions B9 Test adapter - For testing burner controls - ith switch for manual startup of burner - ith switch for simulating the oil preheater s release contact - ith 2 pairs of jacks for measuring the flame detector current - efer to ounting Instructions C9 Test adapter - For testing burner controls fitted to the burner - ith signal lamps for program indication - ith 2 jacks for measuring the flame detector current KF9 KF KF KF Test adapter - For testing burner controls fitted to the burner - ith signal lamps for program indication - ith switch for simulating the flame signal - ith holes for checking the control voltages at the tabs of the burner control - ith 2 jacks for measuring the flame detector s resistance KF0 /0 CCen HVAC Products 09.0.2002

Technical data General unit data ains voltage AC 220 V %...AC 20 V +0 % AC 00 V %...AC 0 V +0 % ains frequency 0...0 Hz ± % External primary fuse (Si) 0 A (fast) Power consumption approx. VA Degree of protection IP 0, must be ensured through mounting Safety class I Perm. cable lengths - Detector cable laid separately - emote reset laid separately ounting position eight Input current to - - max. m with 00 pf/m line capacitance max. 20 m max. 20 m optional approx. 0 g A (short-time A for max. 0. s) A (excl. current draw of burner motor and oil preheater) ax. perm. current at cos 0. LOA2.B2 LOA2.B LOA2.C2 LOA2.C2 LOA2.C LOA2.A2 LOA2.A2 LOA2.A2 0 A A 2 A 2 A A A A A 2 A. A A A LOA2.B2 A A 2 A 0. A A A LOA.A2 Environmental conditions Transport DI E 0 2--2 Climatic conditions class 2K2 echanical conditions class 22 Temperature range -0...+0 C Humidity < 9 % r.h. Operation DI E 0 2-- Climatic conditions class K echanical conditions class 2 Temperature range -20...+0 C Humidity < 9 % r.h. Condensation, formation of ice and ingress of water are not permitted! /0 CCen HVAC Products 09.0.2002

Flame detectors QB... QC... For measuring circuits and detector cable lengths, refer to Data Sheets (QB...) and (QC...). Type of burner control LOA2.B2 / LOA2.B LOA2.C2 LOA2.C2 / LOA2.C LOA2.B2 LOA2.A2 LOA2.A2 LOA2.A2 in. detector current required (with flame) QB... (typically) ax. perm. detector current (without flame) ax. detector current possible (with flame) 0 µa. µa 20 µa µa. µa µa LOA.A2 0 µa. µa 900 µa Type of burner control LOA2.B2 LOA2.C2 LOA2.B2 in. detector current required (with flame) QC... (typically) ax. perm. detector current (without flame) ax. detector current possible (with flame) 0 µa. µa 0 µa LOA2.B 0 µa. µa 90 µa LOA2.C2 ¹) LOA2.C ¹) LOA2.A2 ¹) LOA2.A2 LOA2.A2 --- --- --- µa. µa µa LOA.A2 0 µa. µa 0 µa ¹) These types of LOA... may not be used in connection with QC...blue-flame detectors Data given in the above table only apply under the folllowing conditions: - ains voltage AC 20 V - Ambient temperature 2 C easuring curcuit for detector current QB... 2 LOA... bl sw + µa DC v0/002 QC... 2 LOA... bl sw br + µa DC v02/002 Legend µa DC DC microammeter with an internal resistance of i = max. k bl Blue sw Black br Brown QB... QC... Only with LOA... Indication of flame strength Detector current LED lit - ith QB... - ith QC... min. 0 µa ± % min. 0 µa ± % /0 CCen HVAC Products 09.0.2002

Function Preconditions for startup Burner control is reset Contacts in the line are closed o undervoltage Flame detector is darkened, no extraneous light Undervoltage detection Control sequence in the event of fault An additional electronic circuit ensures that if mains voltage drops below approximately AC V, burner startup will be prevented, or without release of oil lockout will be triggered. henever lockout occurs, the outputs for the fuel valves, the burner motor, oil preheater and ignition equipment will immediately be deactivated (< second). The lockout indication lamp changes to red and terminal 0 («AL») for remote lockout indication receives voltage. This state is also maintained in the event of mains voltage failure. Cause ains voltage failure Extraneous light on burner startup o flame at the end of «TSA» Loss of flame during operation esponse ew start Lockout; with LOA2... / LOA2...: Prevention of start Lockout epetition eset After lockout, the burner control can be reset after 0...90 seconds (also refer to «arning notes»). Indications Lockout position Flame strength The lockout position is indicated with the lamp integrated in the lockout reset button. Only with LOA... Indication of the flame strength (green LED) is used for checking the flame signal. To ensure reliable burner operation, this LED must be lit. If the green LED flickers or extinguishes during burner operation, the light conditions at the burner are poor, caused by dirt for instance. Operation Only with LOA... hen the contacts of the control thermostat are closed, the orange LED is lit, indicating the start of the oil preheater s heating up phase (if present). /0 CCen HVAC Products 09.0.2002

Connection diagram and internal diagram Control sequence LOA2.B2 LOA2.B LOA2.C2 EK Si L L x tz2 fr a b T 2 0 9 2 AL y z c d tz e f g K BV F V bl QB QC br sw a0/002 A A B C D BV FS tw t t TSA d0/002 tn t 2 LOA2.A2 LOA2.A2 EK L tz2 tz fr x y z a b c d e f g K F V a0/002 A A B C D Si L T 2 0 9 2 AL BV bl QB QC br sw BV FS tw tn t tn t TSA t d0/002 2 LOA2.C2 LOA2.C LOA2.A2 EK L tz2 x y z fr** a b c d tz e f g K F V a0/002 A A B C D 2 0 T 9 2 2 Si L AL BV QB. BV FS tw t tn t TSA d02/002 t 2 fr** ot provided with the LOA2.A2 ) LOA2.C2 / LOA2.C 2) LOA2.A2 /0 CCen HVAC Products 09.0.2002

Connection diagram and internal diagram Control sequence LOA2.B2 ith AK2 remote lockout reset module EK tz2 tz fr L x y z c d e f g a b F K V T 2 0 9 2 a0/002 A A B C D tw t tn Si L AL SA BV 0 bl QB QC br sw SA BV t TSA t 2 0 9 AK2A2 EK2 FS d0/002 2 LOA.A2 ith AK2 remote lockout reset module EK tz2 tz fr L x y z c d e f g LED a b F K V L2 T 2 0 9 2 a09/002 A A B C D tw t tn Si L AL SA BV 0 bl QB QC br sw SA BV t TSA t 2 0 9 AK2A2 EK2 FS d0/002 2 Legend AL Alarm device elease contact of oil preheater BV... Fuel valve Oil preheater EK Lockout reset button QB Photoresistive detector EK2 emote lockout reset button QC Blue-flame detector F Flame relay with contacts «fr» bl = blue, br = brown, sw = black fr Bridging contact for release contact of Control thermostat or pressurestat FS Flame signal SA Actuator with automatic setback K Catch of flame relay for locking contact «tz» Safety limit thermostat in the event of premature flame signals or for locking Si External primary fuse the contact when the flame signal is correct T Thermal-electric sequence switch L Indication of faults (red) tz... Contacts of «T» L2 Indication of operation (green) Limit thermostat or pressure switch LED Indication of flame strength (green) V Flame signal amplifier Burner motor Ignition transformer TSA Ignition safety time A Beginning of the startup sequence with burners using an tw aiting time A Beginning of the startup sequence with burners using no t Prepurge time B Time of flame establishment t Preignition time C unning position tn Long postignition time D Controlled shutdown by tn Short postignition time t Interval between flame signal and release of Control signals delivered by the LOA... equired input signals Permissible input signals 9/0 CCen HVAC Products 09.0.2002

Dimensions Dimensions in mm LOA... 22 m0/002 2,, 9, LOA2... LOA... xxxxxxxxxx 2, xxxxxxxxxx 2, 22, m0/000 Status indication, orange Indication of flame strength, green 2 2,, 0 emote lockout reset module AK2A2 + + m0/000 emote lockout reset module for use with the LOA2... / LOA... Printed circuit board with no housing. Degree of protection IP 00, which means that protection against electric shock hazard must be ensured through mounting. Do not place any metal objects in the hatched area. The module must be fitted with the help of spacers made of plastic. Do not use spacers made of metal. 2002 Subject to change! 0/0 CCen HVAC Products 09.0.2002