your tree NEW TREE for you Several facts on trees: Follow our Green Tree heat pumps

Similar documents
HIGH-POWER HEAT PUMPS. Up to 300 kw

AIRLINE - commercial heat pumps Air / water heat pump for heating, cooling and DHW production - commercial use

Advance Split

Technical data LA 60TUR+

A2/W35: 8.6kW, Power consumption: 2.39kW, COP 3,6. A2/W35: 10.1kW, Power consumption: 2,8kW, COP 3,6

Efficient heating that won t cost the earth

Technical data LA 60TU

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP

Technical data LA 28TBS

Technical data LA 9S-TU

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

HT V2 HT Split

Starting current with soft starter Fuse protection

EVI Scroll Air To Water Heat Pumps

Oilon Ground Source Heat Pumps

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

Air/water - Heat pumps

Natural Heat VITOCAL 300-A VITOCAL 350-A. Air source heat pumps

Control Products & Systems OEM

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

Control Products & Systems OEM

High temperature air-to-water heat pumps

PRODUCT LINEUP AIR TO WATER. For RESIDENTIAL. Room Heating & Cooling

Air / Water Heat Pump - Compact Design Modulating 8 18 kw

COLDPACK_. water cooled chillers / heat pumps and condenserless chillers

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Saving energy comes naturally to us.

Product Line Introduction. Karl Zhang Technical support engineer

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels

Pool & Spa The Duratech Heat Pumps

Technical description. Atec.

Pool & Spa The Duratech Heat Pumps

Ground source heat pump range. Why Vaillant? because we can unearth the energy.

AQUAHEAT ADVANCE SPLIT

CHAMELEON. Flexible thermal unit with sophisticated control options.

Modular Air Cooled Scroll Chillers

BWL air heat pumps BWS brine heat pumps

Technical data. Danfoss DHP-L

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

V016-EN-01 AIR TO WATER HEAT PUMPS 2016 HEART OF YOUR HOME

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

V017-EN-01 AIR TO WATER HEAT PUMPS HEART OF YOUR HOME

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

ECOFOREST GEOTERMIA. ecogeo. Ground/Air Source Heat Pumps.

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Liebert HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Planning guide. Atec.

PRODUCT RANGE HEAT PUMPS 2012

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

PRODUCT LINEUP AIR TO WATER For RESIDENTIAL

Technical data. Danfoss DHP-A

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

VIESMANN. VITOCAL Air/water heat pumps. Technical guide. VITOCAL 300-A Type AWC-I and AW-O. VITOCAL 350-A Type AWH-I and AWH-O

Press. Heat pumps from Viessmann: efficient heat generation with renewable energy and electricity

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

LZT High efficiency air to water heat pumps with E.V.I. compressors

PRODUCT DATA SHEETS HEAT PUMPS

Technical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Q Series. Inverter Split Systems

EVI + INVERTER MODELS A Q U A P U R A

Operating instructions and installation of heat pumps Jura pac

- cooling operation - built-in heat meter - electronic circulating pumps

GLIDER_. air cooled liquid chilled chillers / heat pumps

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

THE CARRIER COMFORT LINE

AIR HANDLING UNITS MANDÍK

Heat Pumps. ground-to-water models air-to-water models. Energy-saving solutions

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Galletti Water chillers and heat pumps catalogue

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

Technical Information

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M.

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

S-Therm Air to Water Heat Pumps

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

Air Cooled Chillers & Heat Pumps WinPACK HE-A

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

Heat pumps. Heating systems Industrial systems Refrigeration systems

WHY A MHI HEAT PUMP?

Do you want a versatile solution

EQUIPMENT SNOW DOMES / SKI DOMES

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

Ecoforest. Innovating from the beginning. Foundation of the company. Creation, innovation stars 1968

Air to water Heat Pump System

The Energy Solutions of Withair Heat Pumps Catalogue 2017 Take Control of Your Energy Future!

HYDRONIC SYSTEMS WHY CHOOSING BETWEEN ENERGY EFFICIENCY AND ROBUSTNESS?

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

H4T R410A. refrigerant

Transcription:

Follow our Green Tree heat pumps heat pumps manufacturer Green Join the Hotjet Green Tree your tree for you Line project, let us plant By purchasing the first heat pump in the HOTJET Green Tree product range, you are joining the group of customers supporting products which, while in operation, employ renewable energy contained in the ground, water or air. You will rank among those who install or utilise products which feature more environmentally friendly operating parameters ameters compared to other heat sources, e. g. gas, electric, oil or coal-fired boilers. Thus, you will significantly contribute to maintaining and protecting a clean environment. Thanks to your purchase, a will be planted in co-operation with HOTJET Green Tree partners. NEW TREE HOTJET CZ s.r.o is one of the leaders heat pumps manufacturer on the Czech and Slovak heat pump markets. The success has been achieved by combining uncompromising performance, quality and value. The company headquarters and manufacturing facility are located in Bolatice near to Ostrava. Several facts on trees: The product lines include water-to-air, water-to-water, ground-to-water and split units, ranging from economical solutions to industrial applications, developed by the company s own R&D department. All parts were designed with respect to the current development and technological trends and in cooperation with partners Emerson, Danfoss, Swep and Siemens. Product design is enhanced by leading Czech designers in line with current European trends. Hotjet heat pumps are fully certified and leave production plant with the TÜV SÜD quality label. But Hotjet its not only heat pumps its its GREEN TREE project too. Follow us taking part in this project, let us plant YOUR OWN TREE. * An average healthy tree produces within one hour the same amount of oxygen which is, by estimation, sufficient for at least 2 people for the whole day. * Trees cleanse the atmosphere 2.5 acres of planted trees are capable of ingesting over 30 tons of fly ash during the lifetime. * Trees act as a noise barrier they absorb at least one quarter of all noise. * Trees provide flood protection - they take in water and then release it slowly. * Trees cool the landscape; they increase and maintain air humidity. * Being surrounded by greenery soothes stress and has a positive impact on the state of mind. Export manager If our Green Tree project appeals to you and you are happy with our heat pump, do not hesitate to pass the information on the project to your friends and business partners or register with the Hotjet website at GREEN_tree_PROJECT@hotjet.eu HOTJET CZ, s.r.o. Bolatice Production Plant Průmyslová 966/21 747 23 Bolatice Czech Republic www.hotjet.eu tel.: +420 777 485 475 fax: +420 734 300 225 export@hotjet.eu Thank you.

air to water outdoor unit HOTJET ask Using the outside air as an energy source. Heat pump air-water Hotjet ASK the ideal for a new buildings without the space inside. Compact unit Outdoor installation Stainless steel cabinet The maximum flow temperature to 55 C, EVI compressor 65 C Cooling option Efficient operation to -25 C Bivalent 7.5 kw inside Extremely quiet axial fan Central control of heating and heating of DHW Suitable for floor and radiator systems Wired and wireless control 1. The Electric switchboard 2. Cable 5 m standardly integrated 3. The controller Siemnes basic RVS41 MODEL 8ask 11ask 15ask (EVI) 18ask (EVI) 21ask (EVI) A7/W35 8,8 / 2,0 / 4,4 11,4 / 2,6 / 4,4 13,2 / 3,0 / 4,4 16,2 / 3,7 / 4,4 18,4 / 4,2 / 4,4 A2/W35 7,6 / 2,0 / 3,8 9,9 / 2,6 / 3,8 11,5 / 3,0 / 3,8 14,1 / 3,7 / 3,8 16,0 / 4,2 / 3,8 A7/W45 8,4 / 2,4 / 3,5 11,3 / 3,2 / 3,5 13,0 / 3,7 / 3,5 15,8 / 4,5 / 3,5 18,3 / 5,2 / 3,5 A2/W45 7,4 / 2,4 / 3,1 9,9 / 3,2 / 3,1 11,4 / 3,7 / 3,1 13,9 / 4,5 / 3,1 16,0 / 5,2 / 3,1 Cooling power A35/W7 5,5 7,5 8,8 11,1 12,6 A35/W20 8,1 10,8 12,8 15,9 17,9 Temperature operating limits for air -20 C to 35 C Temperature limit of heating system +20 to +55 C (EVI +15 to +65 C) Heating and reversing water communication pipe 1 Heating water flow rate 1,3 m³/h 1,5 m³/h 1,8 m³/h 2,6 m³/h 3 m³/h Pressure loss < 20 kpa Protection against freezing water heating Yes Air flow rate 3 000 m³/h 4 500 m³/h R404A (EVI R407c) Refrigerant quantity (Kg) 2,6 2,8 2,8 2,9 2,9 Defrosting Automatic Type of defrosting Cycle reversal Dimensions (W x D x H) 1275 x 503 x 1110 mm Weight 145 145 150 155 160 Installation site Outdoor Cabinet Stainless steel Degree of protection (EN 60 529) IP 43 a/n/pe ~400 V, 50 Hz (230 V / 1 phase ly) 400V / 3 / 50 Hz Copeland scroll (EVI) Nominal current (A) 4,5 5 5,8 9 9,1 Starting current (A) 18 20 23 36 36,4 Maximum current (A) 6,5 7 8,8 12,8 13,1 Fusing [A] 16 B 16 B 16 B 20 B 20 B Compressor supply line (n x mm 2 ) 5 x 2,5 Sound power level db(a) < 61 Sound pressure level at 1 m db(a) < 57 Siemens RVS41 (ly RVS61) Softstart unit ly Danfoss Integration into cascade Up to 16 heat pumps or mixed sources ase supported HOTJET ASK Green Line Heat output and COP according to EN 14511 at A2/W35 (A2 = air intake temperature +2 C, W35 = heating water outlet temperature +35 C).

brine to water / water to water HOTJET w New models of heat pumps, brine-water and water-water, bring an entirely new body design, the cooling circuit and control electronics. Compact size with installation options for the wall Indoor installation Guard cover is made of power coating Effective corrosion protection The maximum flow temperature to 55 C, with R134 75 C. Support for passive cooling or compressor The heat source is ground collector, borehole or well Central control of heating and heating of DHW Suitable for floor and radiator systems The compact design has a small space requirement (0.35 m 2 floor plan) 1. The Electric elements 2. The controller Siemnes basic RVS41 MODEL 9W 12W 16W 20W 33W 55W B0/W35 7,5 / 1,63 / 4,6 10,4 / 2,26 / 4,6 16,0 / 3,48 / 4,6 19,2 / 4,17 / 4,6 32,0 / 6,96 / 4,6 46,0 / 11,4 / 4,0 B0/W45 7,1 / 2,05 / 3,5 10,0 / 2,89 / 3,5 15,0 / 5,33 / 3,5 18,1 / 5,23 / 3,5 30,2 / 8,73 / 3,5 41,0 / 14,8 / 2,8 W10/W35 10,4 / 1,62 / 6,4 14,7 / 2,29 / 6,4 22,3 / 3,48 / 6,4 26,3 / 4,10 / 6,4 44,0 / 6,86 / 6,4 67,0 / 11,9 / 5,6 W10/W45 9,8 / 2,03 / 4,8 13,8 / 2,86 / 4,8 20,9 / 4,33 / 4,8 24,5 / 5,07 / 4,8 41,0 / 8,49 / 4,8 49,0 / 15,5 / 3,2 Cooling power B15/W23 5,6 7,8 11,9 14,3 23,8 34,3 Temperature limit of primary side -10 C to +30 C Temperature limit of heating system +15 C to +55 C Heating and reversing water communication pipe 1 (3/4 ) 2 Volume rate of flow, primary side (m 3 /h) 1,1 1,8 2,6 3,0 4,4 7,9 Water passage through the heating circuit (m 3 /h) 1,0 1,6 2,3 2,7 4,2 7,2 Head loss, heating side < 20 kpa < 30 kpa Head loss, primary side < 25 kpa < 35 kpa Protection of heating water against freeze-up R407C / R134A Refrigerant quantity (Kg) 1,8 2,2 2,5 2,6 4 6 Dimensions (W x D x H) 650 x 563 x 1110 mm 630 x 580 x 1080 mm 890 x 740 x 1115 mm Weight (kg) 103 103 112,5 114 115 267 Installation site Indoor Cabinet Powder coat, galvanized sheet, cataphoresis Degree of protection (EN 60 529) IP 24 400V / 3 / 50 Hz Copeland scroll Nominal current [A] 4,5 5,8 9 9,1 17,9 25 Starting current [A] 18 23 36 38 55 80 Maximum current [A] 6,5 8,8 12,8 13,1 20,4 27 Fusing [A] 16B 16B 20B 20B 32B 40B Compressor supply line (n x mm 2 ) 5 x 1,5 5 x 2,5 5 x 6 Sound power Lw [db(a)] < 50 < 60 Sound pressure Lp [db(a)] < 40 < 50 Siemens RVS41 (ly RVS61) Soft start unit ly Danfoss (Siemens) Integration into cascade Up to 16 heat pumps or mixed sources are supported HOTJET w Green Line Heat output and COP according to EN 14511 at B0/W35 (B0 = brine inlet temperature 0 C, W35 = heating water outlet temperature +35 C). Heat output and COP according to EN 14511 at W10/W35 (W10 = ground water inlet temperature +10 C, W35 = heating water outlet temperature +35 C).

air to water indoor unit HOTJET i Using the outside air as an energy source. Designers of the HOTJET i manage to fit heat pumps in any small spaces of 0.5 m 3. HOTJET i can be installed in house interiors, e.g. in cellars, garages or in spaces for a building equipment. Atmospheric air is supplied and drained by air lines through a wall. Compact unit Indoor installation Guard cover is made of stainless steel sheet or powder coating The maximum flow temperature to 55 C. Sound-optimised through low-noise axial-flow fan Central control of heating and heating of DHW Suitable for floor and radiator Systems Wired and wireless control 1. The Electric elements 2. The controller Siemnes basic RVS41 MODEL HOTJET 8i HOTJET 11i HOTJET 15i A7/W35 7,8 / 2,04 / 3,8 9,3 / 2,45 / 3,8 10,8 / 2,79 / 3,8 A2/W35 7,2 / 2,01 / 3,6 8,6 / 2,39 / 3,6 10,1 / 2,76 / 3,6 A7/W45 7,4 / 2,46 / 3,0 8,8 / 2,93 / 3,0 10,3 / 3,39 / 3,0 A2/W45 6,6 / 2,46 / 2,7 8,0 / 2,96 / 3,0 9,3 / 3,44 / 2,7 Temperature operating limits for air -10 C to +35 C Temperature limit of heating system +15 C to +55 C Heating and reversing water communication pipe 3/4 Heating water flow rate 1,3 m³/h 1,5 m³/h 1,8 m³/h Head loss, heating side < 20 kpa Protection against freezing water heating Air flow rate 2 200 m³/h 2 200 m³/h 2 200 m³/h Air channel diameter 400 mm R404A Refrigerant quantity (Kg) 2,1 2,3 2,4 Defrosting Automatic Type of defrosting Cycle reversal Heating of the condensate bulk tank Condensate drainage By a hose Dimensions (W x D x H) 1105 x 655 x 955 mm Weight (kg) 215 kg Installation site Indoor Cabinet Powder coat, galvanized sheet, cataphoresis Degree of protection (EN 60 529) IP 40 3/N/PE ~400 V, 50 Hz (230 V / 1 phase ly) 400 V / 3 / 50 Hz Copeland scroll Nominal current (A) 4,5 5 5,8 Starting current (A) 18 20 23 Maximum current (A) 6,5 7 8,8 Fusing (A) 16B 16B 16B Compressor supply line (n x mm 2 ) 5 x 2,5 Sound power Lw [db(a)] < 50 Sound pressure Lp [db(a)] < 37 Siemens RVS41 (ly RVS61) Softstart unit ly Danfoss Integration into cascade Up to 16 heat pumps or mixed sources are supported HOTJET i Green Line Heat output and COP according to EN 14511 at A2/W35 (A2 = air intake temperature +2 C, W35 = heating water outlet temperature +35 C).

air to water Split system HOTJET s Split system using the outside air as an energy source the compressor is inside the house and the refrigerant temperature in the connecting pipe is low, the evaporator can be placed 20 meters away in the garden and to eliminate the noise problems and needed a place. Indoor and outdoor unit connected with refrigerant circuit The maximum flow temperature to 55 C Cooling option Outdoor unit is made of stainless steel cabinet Indoor unit is made of power coating Remarkably low sound level Central control of heating and heating of DHW It is suitable for floor and radiator Systems Wired and wireless control 35S optinal 2 evaporators 50S standard 2 evaporators 1. The Electric elements 2. Cable 5 m standardly integrated 3. The controller Siemnes basic RVS41 MODEL 8s 11s 15s 18s 22s 35s 50s A7/W35 8,8 / 2,0 / 4,4 11,4 / 2,6 / 4,4 13,2 / 3,0 / 4,4 16,2 / 3,7 / 4,4 18,4 / 4,2 / 4,4 28,8 / 6,56 / 4,4 40,7 / 9,3 / 4,4 A2/W35 7,6 / 2,0 / 3,8 9,9 / 2,6 / 3,8 11,5 / 3,0 / 3,8 14,1 / 3,7 / 3,8 16,0 / 4,2 / 3,8 25,1 / 6,57 / 3,8 35,4 / 9,3 / 3,8 A7/W45 8,4 / 2,4 / 3,5 11,3 / 3,2 / 3,5 13,0 / 3,7 / 3,5 15,8 / 4,5 / 3,5 18,3 / 5,2 / 3,5 27,2 / 7,7 / 3,5 38,9 / 11,1 / 3,5 A2/W45 7,4 / 2,4 / 3,1 9,9 / 3,2 / 3,1 11,4 / 3,7 / 3,1 13,9 / 4,5 / 3,1 16,0 / 5,2 / 3,1 23,8 / 7,7 / 3,1 34,1 / 11,1 / 3,1 Temperature operating limits for air -20 C to +35 C Temperature limit of heating system +12 C to 60 C R407C / + 6 C +55 C R404A Heating and reversing water communication pipe 1 2 Heating water flow rate 1,3 m³/h 1,5 m³/h 1,8 m³/h 2,6 m³/h 3 m³/h 4,2 m³/h 7 m³/h Pressure loss of heating Party < 20 kpa < 30 kpa Protection against freezing water heating R407C / R404A Refrigerant qvantity (Kg) Defrosting automatic Type of defrosting Cycle reversal Dimensions (W x D x H) Indoor unit 650 x 563 x 1110 mm 890 x 740 x 1380 mm Number of evaporators 1 1 (option 2x fans) 2 (option 3x fans) Dimensions (W x D x H) outdoor unit 1075 x 630 x 1110 1275 x 630 x 1110 mm Weight (kg) - indoor unit 110 110 115 120 125 185 205 Weight (kg) - outdoor unit 90 190 285 Installation Split system Corrosion protection inside the unit Powder coat, galvanized sheet, cataphoresis Anticorrosive protection of the outdoor unit stainless steel, unvarnished Sheets Degree of protection (EN 60 529) IP 43 3/N/PE ~400 V, 50 Hz (230 V / 1 phase ly) 400 V / 3 / 50 Hz Copeland scroll Nominal current (A) 4,5 5,8 7 9 9,1 17,9 25 Starting current (A) 18 20 23 36 36,4 55 80 Maximum current (A) 6,5 7 8,8 12,8 13,1 20 30 Fusing [A] 16B 16B 16B 20B 20B 32A char B 40A char C Compressor supply line (n x mm 2 ) 5 x 1,5 5 x 1,5 5 x 1,5 5 x 1,5 5 x 2,5 5 x 4 5 x 10 Sound power Lw [db(a)] < 50 < 60 Sound pressure Lp [db(a)] < 40 < 50 Siemens RVS41 (ly RVS61) Softstart unit ly Danfoss (Siemens) Integration into cascade Up to 16 heat pumps or mixed sources are supported HOTJET s Green Line Heat output and COP according to EN 14511 at A2/W35 (A2 = air intake temperature +2 C, W35 = heating water outlet temperature +35 C).

air to water outdoor unit HOTJET one HOTJET launches new range of heat pumps, economy solution airwater model represented by HOTJET ONE 15. Series one is a brand new generation of heat pumps that are cost-optimized, whilea high COP, low noise and a sophisticated control Siemens. Compact unit Outdoor installation Guard cover is made of powder coating Efficient corrosion protection The maximum flow temperature to 55 C, EVI compressor 65 C Efficient operation to -20 C Silent low speed fan with a diameter of 630 mm. Cooling option 1. The Electric elements 2. Room and operator unit wired QAA75 3. The controller Siemnes basic RVS21 4. Circulation pump Grundfos UPS 25-70 MODEL 8ONE (EVI) 15ONE (EVI) 18ONE (EVI) Easy solution T B9 A7/W35 8,8 / 2,0 / 4,4 13,2 / 3,0 / 4,4 16,2 / 3,7 / 4,4 A2/W35 7,6 / 2,0 / 3,8 11,5 / 3,0 / 3,8 14,1 / 3,7 / 3,8 A7/W45 8,4 / 2,4 / 3,5 13,0 / 3,7 / 3,5 15,8 / 4,5 / 3,5 A2/W45 7,4 / 2,4 / 3,1 11,4 / 3,7 / 3,1 13,9 / 4,5 / 3,1 Cooling power A35/W7 5,5 8,8 11,1 A35/W20 8,1 12,8 15,9 Temperature operating limits for air -20 C to +35 C Temperature limit of heating system +25 C to +55 C (EVI: +15 C to +65 C) HOTJET one Heating and reversing water communication pipe 1 Q9 TO1 T RG Heating water flow rate 1,3 m³/h 2 m³/h 2,6 m³/h Pressure loss 8 kpa Protection against freezing water heating Air flow rate 3 000 m³/h 4 500 m³/h R407C Defrosting Automatic Type of defrosting Cycle reversal Heating of the condensate bulk tank Dimensions (W x D x H) 1275 x 550 x 952 mm Weight (kg) 145 Installation site Outdoor EconomyLine Cabinet Powder coat, galvanized sheet, cataphoresis Degree of protection (EN 60 529) IP 43 3/N/PE ~400 V, 50 Hz (230 V / 1 phase ly) Room thermostat and operation unit QAA75 400 V / 3 / 50 Hz EVI: Sanyo scroll Nominal current (A) 4,5 5,8 9 Starting current (A) 18 23 36 Maximum current (A) 6,5 8,8 12,8 Fusing (A) 16B 16B 20B Compressor supply line (n x mm 2 ) 5 x 2,5 Sound power Lw [db(a)] < 61 Sound pressure Lp [db(a)] < 57 Softstart unit ly Danfoss Condensate Pump Grudfos UPS 25-70 Heat output and COP according to EN 14511 at A2/W35 (A2 = air intake temperature +2 C, W35 = heating water outlet temperature +35 C).

HOTJET service HOTJET heat pumps ON-LINE system make possible 24 hours service throught internet et Checking system Webserver Remote and local control and diagnostic in the LPB / BsB bus Control via Web browser Control via SMS commands Alarms Version OZS164.13/101 Web Control OZS164.23/101 Web Control and SMS Control Remote Installation Support (using OCI700) Notebook in the boiler room with internet connect (GPRS, Wi-Fi, ADSL ) Service tools ols OCI700 switchboard with RVS internet Notebook (netbook) Service tool: OCI700 Options Setting all parameters of RVs Offline preparation of configuration without connection Archiving controller setting Cloning of parameters between the regulators Logging of any data Visualization of the boiler room (boiler automatic generation scheme, the user can change) Protocol on the commissioning Easily sending of configuration file via e-mail (about 1MB) Alarms and batch processing In the case of multiple RVs on the bus is displayed at once Case contains Transmitter LPB/ BsB to UsB Cables Software (free updates on the Internet)

heat pumps manufacturer Green Line HOTJET CZ, s.r.o. Bolatice Production Plant Prumyslová 966/21 747 23 Bolatice Czech Republic www.hotjet.eu tel.: +420 777 485 475 fax: +420 734 300 225 export@hotjet.eu