Bi-Directional Barrier Arm Turnstile

Similar documents
Tailgate > Entry Sentry > ES5200

4040 FM 535 F :

OPTICAL TURNSTILE SYSTEM

ARCHITECTURAL SPECIFICATIONS

The following modes can be set when the units are installed, and/or can be changed later through use of a push button on the desktop controller:

OPTICAL TURNSTILE SYSTEMS

ES860 OPTICAL TURNSTILE INSTALLATION AND OPERATION MANUAL PRESENT CARD

OptiStile 220. Swinging Barrier Arm Optical Turnstile

Custom options such as housing finishes and design, lid have their presence felt. A combination of sleek, sophisticated

SpeedStile FP. Full-Panel Speed Gate with Sliding Glass Barrier

SU2000-SM. model OPTICAL TURNSTILES DESCRIPTIVE SPECIFICATIONS TYPICAL INSTALLATION SITES COMMON APPLICATIONS ALVARADOMFG.COM

OptiStile 400. Non-Barrier Optical Turnstile

17.25 (438 mm) 37.5 (953 mm) 3.5 (89 mm) 3.0 (76 mm) 28 (711 mm) or 36 (915 mm)

ES880 GLASS BARRIER OPTICAL TURNSTILE INSTALLATION AND OPERATION

SU5000. Optical Turnstiles. alvaradomfg.com

Security Considerations for Secure Workplaces

System Design and Overview Document

CARD ACCESS CONTROL SYSTEM

Outline Specification: EDSUKMT1 MAN TRAP CYLI NDER GATE

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

TD flex is an award-winning tailgate detection solution that prevents unauthorized access at: Doors Mantraps Airlocks E-gates Turnstiles

1.1 Ensure the room is in the ACCESS state. Workstation indicates zone is in ACCESS state.

SpeedStile FP/FPW. Full-Panel Speed Gate for Internal Installation

BLG77 Rising Fenced Barrier

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

Full Height Security Turnstiles

Solicitation Requirements Matrix

Why Should You Invest In An Access Management System?

Tripod Turnstiles. Tripod Turnstile for Public Transport Application

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

Effective Human Detection and Tracking Security Using Machine Vision

Engineering Specifications

In N/C the SpeedStile provides a closed walkway and will only open on acceptance of an authorised signal.

HARDwired Installation/ Owner s Manual

Electromechanical Box Tripod Turnstile with Autimatic Anti-Panic Function, Two Built-in Readers and a Card Capture Function

Summit 3208GLD USER MANUAL. Electronics Line

SECTION OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

CORNELL Emergency Response Systems

SP-1000X. Panic Device Power Controller Installation Guide. Rev

THE FUTURE OF RETRACTABLE BOLLARDS BULLYBOY PRODUCT INFORMATION

ELEVATOR UPGRADE AND MODERNIZATION

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Installation, Operating and Maintenance Manual

**** **** A B ARMED FIRE FIRE C D READY OFF AWAY STAY 2 3 MAXIMUM TEST BYPASS PULL INSTANT CODE CHIME. First Alert READY. * 0 # Professional

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

ACP10 & ACP50 Security Systems

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

Table of Contents. Appendix A Special Characters 31

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

Speed Gate ST-01. Double-Sided Section STD-01 ASSEMBLY AND OPERATION MANUAL

A. Section Masonry Assemblies: Anchor placement in masonry.

5900 SERIES Low Energy Power Operator

D720 and D1255 Command Centers

Addressable Fire Alarm Control Panel

SlimStile BA. Tripod Turnstile for Internal Installation (*)

POWER TRANSFERS ACCESSORIES EAC. Manufacturer Product Product No. Product Description Item No.

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

RFP Addendum 2 March 31, 2016

TW-8000 TAUT WIRE FENCE

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

CIRCLELOCK COMBI YOUR ENTRY EXPERTS. THE HIGH SECURITY CONNECTION PORTAL

D1255RB/D1256RB/D1257RB

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

FIRE DOOR CLOSING SYSTEMS

Solutions for Common Problems

385 SERIES REMOTE HANDHELD SIREN ETSA385HR

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

ELECTRONIC SOUNDER STROBE Model : AVD-C407

VISTA-50P VISTA-50PUL

BL41 Extra-long Barrier

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

AXS Strikemaster Engineering Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

SIA/IAPSC CAD Security Symbols

Intelligent Swing Gate Turnstile Operating Manual CPW-322CS

FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS

Delayed Egress System DORMA EMDE

BL 53 Security Barrier ENGINEERING SPECIFICATIONS

Section PERIMETER SECURITY SYSTEMS

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

TrueAlarm Fire Alarm Controls

SPLIT-DECODED CONTROLLER

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Power Transfer Devices. Access Control Accessories. How To Order. How to Order

Contents. Glossary

GUIDELINES FOR EMERGENCY PLANNING AND PREPAREDNESS. High-Hazard

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

FIRERAY 5000 range USER GUIDE

OJD ITB No Attachment E Duress Alarm Equipment Specifications

VANDAL RESISTANT BACK-LIT WEATHERPROOF RFID ACCESS CONTROL KEYPAD

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Transcription:

ES831 *Custom model shown in stone and bronze Bi-Directional Barrier Arm Turnstile Model ES831

Optical Turnstiles > ES831 Series > Optical Turnstiles w/ Barrier Arms > Design Overview The ES831 bi-directional optical turnstiles with hands-free barrier arms enhance the security of access control systems. The ES831 provides a visual as well as a psychological barrier while communicating to pedestrians that authorization is required to gain access to a facility or area. Where high-speed pedestrian throughput and aesthetics are priorities, ES831 barrier arm turnstiles can grant access for up to 60 people per minute per lane and are surfaced to match the interior of any lobby with standard or custom designs and nishes. Compatible with most reader and access control technology, they detect, deter, and report attempts to enter without a valid card or by "tailgating" behind authorized personnel. This system can be eld selected as a Card-in/Free-exit, or Card-in/Card-out system con guration. Optical Turnstiles with Barrier Arms meet the standard of the Americans with Disabilities Act of 1990. OT w/ Barrier 1

Optical Turnstiles > ES831 Series > Optical Turnstiles w/ Barrier Arms > Technical Info Product Description/Technical Information Con guration: Card Readers: Local Annunciation: Field selectable Card-in/Card-out, or Card-in/Free-exit pedestrian control. Card readers to be supplied by others and may be mounted by DSI. Visual and audible annunciation is provided at each passageway to provide status of passageway, indication of valid card read, invalid card or alarm condition. Vertical Graphic Arrays/VGA s are solid state. Nomenclature: OPEN/CLOSED/WAIT ( ashes on alarm condition). Horizontal Graphic Arrays/HGA s are solid state. Nomenclature: PRESENT CARD/PROCEED (with arrow sequence) and Flashing Red Bar (for alarm condition). Audible: Distinctive tones for valid card and alarm condition. Short chime sounds to indicate access has been granted. Buzzer sounds upon alarm condition. Remote Annunciation: Interfaced to access control and/or security monitoring systems. (Optional) Control Inputs: Status Outputs: N/O - momentary Entry Card (max. 1 sec. pulsed closure) N/O - momentary Exit Card (max. 1 sec. pulsed closure) N/O - momentary Invalid Card N/O - maintained Bypass/Reset N/O - maintained Entry Closed N/O - maintained Exit Closed N/O - maintained Arm Disable N/O - maintained Free Exit N/O - maintained Emergency (Situation) N/O - maintained Voice Enable (Horn Disable) [optional] N/O - Alarm signal N/O - Time Out signal N/O - Valid Passage (after valid card read) signal N/O - Bypass/Reset N/O - Invalid Card Aux. Output Power - +/- 12 VDC @ 2 amp (max) Relays rated 1.0 amp @ 30 VDC/contacts provided for interface to building access control, re/life safety, security, CCTV, and monitoring systems. Components: Pedestrian Throughput: All components and electronic sub-assemblies including the microprocessor controller of the Optical Turnstiles are mounted within the bollards; thus reducing the total cost of installation, labor hours, conduit, wire, and cable. Typical pedestrian throughput is 60 people per minute, 3600 per hour, per lane. OT w/ Barrier 2

Optical Turnstiles > ES831 Series > Optical Turnstiles w/ Barrier Arms > Technical Info Product Description/Technical Information (contd.) Interface: The DSI Optical Turnstiles will utilize the building access control system to grant or deny access. Code Compliance: The Americans With Disabilities Act of 1990/ADA, nonrestrictive barrier-free design provides equal access. NFPA 101 Life Safety Code and most standard building codes. Manufactured: Operation: Barrier Arm: The microprocessor, Vertical Graphic Arrays/VGA s and Horizontal Graphic Arrays/HGA s are solid state in design and all barrier arm components are designed for virtually maintenance free operation. High-speed/nonrestrictive pedestrian passageways. Passageways are truly bi-directional at all times. Arm shall act as a soft barrier to control passage while allowing users to push-to-clear for emergency egress. Arm travels in a 180 horizontal plane and shall be electromechanically driven. (No pneumatic components or compressed air supply will be used.) The barrier arm will be extended at all times and will swing open when valid access credentials are presented. The arm shall move 90 from the extended position to the retracted position in the direction the user is traveling. Arm Construction: The barrier arm shall be constructed of anodized aluminum with a satin brushed nish. The arm weight shall be minimized to reduce the inertia of the arm in motion. The arm shall have suf cient strength to withstand vertical forces expected in the workplace environment without permanent damage. Arm Length: 17 beyond the bollard provide coverage over a 36 wide space with a maximum of 2 between arm tips. Clearance Sensors: Six (6) IR optical beams within the passageway shall sense direction, detect tailgaters and obstructions. Emergency Egress: Push-to-Emergency Exit design is built into the barrier-arm so the pedestrian passageway does not obstruct emergency evacuation of the facility. Alarm outputs activate if arms are pushed away. Force required to push arm away is consistent with ADA speci cations. Finish: Bollard Dimensions: Bollard Spacing: Top Surface: DuPont Corian, Nevamar Laminate or stainless steel. Side Surface: Stainless steel, Formica, Nevamar Laminate. 64 long x 38 high x 10 wide. 36 recommended to meet ADA requirements. OT w/ Barrier 3

Optical Turnstiles > ES831 Series > Optical Turnstiles w/ Barrier Arms > Technical Info Product Description/Technical Information (contd.) Bollard Mounting: Conduit Size: The bollards shall be secured to the oor through the use of four (4) anchor bolts at each end of the assembly. Concealed access panels shall be provided on the bollard s side to provide access for anchoring. Limited by all components including the microprocessor being located in the bollards. All required wiring is low-voltage and can be run in one conduit. Maximum size 1.5 if all I/O functions are utilized. Power Requirements: 24VDC @ 4 amps. per passageway. Power supply supplied by others and can be mounted in equipment room. (Backup power source should be considered for many applications.) Wiring Requirements: From access control systems to control bollard: (Some connections may be optional.) Card reader cable as speci ed by manufacturer Entry Granted (Input) 2 conductor/22 ga. (min.) Exit Granted (Input) 2 conductor/22 ga. (min.) Invalid Card (Input) 2 conductor/22 ga. (min.) Bypass lane (Input) 2 conductor/22 ga. (min.) Emergency Situation (Input) 2 conductor/22 ga. (min.) Arm Operation Disable (Input) 2 conductor/22 ga. (min.) Free-Exit Enable (Input) 2 conductor/22 ga. (min.) Entry Closed (Input) 2 conductor/22 ga. (min.) Exit Closed (Input) 2 conductor/22 ga. (min.) Alarm Condition (Output) 2 conductor/22 ga. (min.) Passage Completed (Output) 2 conductor/22 ga. (min.) Time Out (Output) 2 conductor/22 ga. (min.) lane Bypassed (Output) 2 conductor/22 ga. (min.) 24VDC Power 2 conductor/12 ga. (min.) Wiring from control bollard to adjacent passageway bollard: Card reader cable as speci ed by manufacturer Horiz. Graphic Display 8 conductor telephone cable/26 ga. Verti. Graphic Display 4 conductor telephone cable/26 ga. Motor Cable 4 conductor shielded cable/18 ga. Encoder Cable 4 conductor shielded cable/22 ga. Note: Wiring may vary depending on options and conduit runs. OT w/ Barrier 4

Optical Turnstiles > ES831 Series > Optical Turnstiles w/ Barrier Arm OT w/ Barrier 5

Optical Turnstiles > ES831 Series > Optical Turnstiles w/ Barrier Arm 22.00 CARD READER (SURFACE OR FLUSH MOUNT) 38.00 32.17 30.45 0.50 10.00 END VIEW ES 831 CENTER BOLLARD SHOWN HORIZONTAL GRAPHIC ARRAY TOP VIEW CORIAN TOP & REVEAL 1" CORIAN TOP 0.50" CORIAN REVEAL BLACK ANODIZED ALUMINUM ARM HOUSING CLEAR ANODIZED ALUMINUM ARM IR PLEXIGLAS SENSOR WINDOW LIGHT GRAIN LIGHT GRAIN IR PLEXIGLAS SENSOR WINDOW REMOVABLE SIDE 11.00 42.00 64.00 FRONT VIEW 6" X 8" WIRING ACCESS HOLE Ø0.88 MOUNTING HOLES 4.00 11.00 18.00 40.00 BOTTOM VIEW CARD READER (SURFACE OR FLUSH MOUNT) FLUSH MOUNTED CARD READER 30 SLOPE END VERTICAL GRAPHIC ARRAY LIGHT GRAIN END VIEW 14 GA BRUSHED STAINLESS STEEL OR POWDER PAINTED STEEL OT w/ Barrier 6

Optical Turnstiles > ES831 Series > Optical Turnstiles w/ Barrier Arm OT w/ Barrier 7

Optical Turnstiles > ES831 Series > Optical Turnstiles w/ Barrier Arm OT w/ Barrier 8

Optical Turnstiles > ES831 Series > Accessories and Options ES831 Accessories Floor plates Floor Plates are used where oors cannot be core drilled such as in landmark buildings. The Floor Plates provide a mounting surface for the turnstiles and provide a wire way to run all cables. The ES831 oor plates meet the standard of the Americans with Disabilities Act of 1990. Card reader decals Provides an icon to help communicate to users where the card reader is located. Power Supply The PS/DC24 Power Supply is a regulated and ltered, multiple output power supply intended for use with access control and re alarm systems. Power management applications include optical turnstiles, door management alarms, annunciator panels, lock power, reader and associated security device power. Battery standby is optional, based upon application. ES831 Options Visitor/Bar code reader DSI can provide a bar code reader system in the turnstiles to process a temporary visitor badge. Please call to con rm the con guration of your speci c readers. Card reader mounting DSI provides, free of charge, card reader mounting during the fabrication of the turnstiles, in some cases, were multiple readers and/or access control boards are used, there may be an extra charge. Card collector This option is used in buildings with a large amount of visitors. The system will collect the visitors card prior to allowing them to exit the turnstile. The card can then be reused after being removed from the collection drawer. Voice module The Voice module uses a digital recording to help convey commands to the users of the turnstile. Standard messages include Proceed and Present Card. The voice module is also used with the card collector to prompt visitors leaving the turnstile to return their badge. Locking arm The locking arm option is used in applications where a hard-barrier is required on the entrance side of the turnstiles. The ES831 utilizes an automatic locking mechanism that engages only when someone enters the walkway without a valid card read, thus extending the life of the product. Once the arms are locked they will remain in the locked position until the walkway is cleared of pedestrians, it is now ready for the next user. OT w/ Barrier 9