Whirlpool AUTOMATIC ICE CUBE MAKER. User s Instructions & Care and Cleaning Guide MODELS CH E-5R CHS-5R CHE-7R CHS-7R. Part No.

Similar documents
ICE MAKER Use & Care Guide. Table of Contents... 2

INSTALLATION MANUAL. Series 322 Ice Cube Machine SPECIFICATIONS UNPACKING. Series 322 Ice Cube Machine Installation Instructions

Owner / Operator Use and Care Guide I SERIES 224 ICE CUBE MACHINE

User information. Cleaning/descaling and sanitizing

PERLICK PRODUCT MANUAL SELF-CONTAINED ICE MAKER MODELS: H50IMS-R H50IMS-L H50IMW H50IMS-ADL H50IMS-ADR H50IMW-AD

Installation and User's Manual for Residential Ice Machine. Models SCCG30 and SCCP30

AUTOMATIC WASHER. Super Capacity Model LA609OXS

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

SPIKA NG ICE MAKER MAINTENANCE

Reliability is a beautiful thing TM MODULAR FLAKER F-800MAH(-C) F-800MWH(-C) INSTRUCTION MANUAL

USER MANUAL Model DWP-55/DWP-66

I N ST R UC T I ON MODEL 2612 & 2712 SLICERS MODELS 2612 ML ML FORM (12-98) 2612 SLICER

i!iifziw AUTOMATIC WASHER Large Capacity Model LA6150XS and Surface Units. Ranges, MIcrowave Ovens, Trash Compactors. Room Au Condltloners, Oehumli

Installation and User's Manual for Outdoor Model Residential Ice Machine. Models SCCG50M-1SS and SCCP50M-1SS

AUTOMATIC WASHER Super Capacity Variable Three Speed

AUTOMATIC WASHER. Design 2000 Large Capacity Model LA7460XM

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Model:WHS-109FB1/WHS-109FW1/WHS-109FSS1

Use & Care Guide AIR CONDITIONERS ACQ082 ACQ102 ACQ122 ACU082 ACU102 ACU124. fi'ter 1. Removable Control panel

AUTOMATIC ICE MAKER. Use and Care Guide. Ice Thickness Control H Cycle or Service Switch / Model and Serial Number (inside, not shown) Bin Grille

Owner s Manual Super-Slim Four-Way Cassette

THERMO POT MODEL: ETP-D4013(WH)/ ETP-D5013(WH)/ ETP-D6013(WH) Owner s Manual. Please read this manual carefully before operating your set.

CME256, 506, 656, 806: AutoIQ Cubers

AUTOMATIC WASHER. Design 2000!3uoTe; Capacity LA5591XP

THERMO POT MODEL: ETP-C3211(WH) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

Hoshizaki America, Inc.

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

ICE MAKER Model 50. _. :a:; :& : $ys;*g :m.-,. ::,~~~;,~-,s,~..-:o-,~,-n, c_ Ipi.,r--.**i;p *... +~..?/ f,.

Hoshizaki America, Inc.

Hoshizaki America, Inc.

AUTOMIATIC I WASHER. Large Capacity Model LA5000XM

Installation and User's Manual for Cuber Model CU0515

SELF-CONTAINED CRESCENT CUBER

AUTOMATIC WASHER. Convertible Compact Model LC49OOXM

KSD-35 DR11 KUE-35 DVN11

SELF-CONTAINED FLAKER

ISSUED: FEB. 23, 1998 REVISED: OCT. 15, 1999 HOSHIZAKI MODULAR FLAKER MODEL F-450MAF(-C)

Installation and User's Manual for Residential Ice Machine. Models SCCG50 and SCCP50

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6

Instruction Manual. Chest Freezer. Model: ACFM050ADB INSTALLATION INSTRUCTIONS. Before Using Your Freezer Remove the exterior and interior packing.

Operating Instructions

SCE275: CM 3 Under-the-counter. Technical Training

Thank you for buying this refrigerator-freezer. To ensure that you get the best

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Hoshizaki America, Inc.

Installation Manual UNIVERSAL C-750 PRE-MIX DISPENSER

Hoshizaki America, Inc.

HOSHIZAKI MODULAR CRESCENT CUBER MODELS KM-280MAH KM-280MWH INSTRUCTION MANUAL

AUTOMATIC WASHER. Super Capacity Model LA98OOXP. Solid State Mark II Series Electronic Touch Control

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

Installation Operation and Maintenance Instructions

Water Distillation System Instruction Manual Nutriteam TC-501

AUTOMATIC WASHER. Design 2000 Large Capacity Model LA7400XM

Cleaning and Sanitation Procedures Module Deli

Pitcher Water Filtration System Use and Safety Instructions

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

USE/INSTALLATION INSTRUCTIONS

Cleaning Household Linens and Furnishings

AUTOMATIC WASHER. Super Capacity Model LA78OOXS

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

SPR7-OS SPR601-OS SCR600L-OS SPR601-OSRC SCR600L-OSRC SP6DSSTB-OS

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

Scotsman Technical Training. CU50 Cube Ice Machine

Korean Side-by-Side Refrigerator Use and Care Manual

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Automatic Undercounter Ice Maker

Installation Operation and Maintenance Instructions

SaniServ. Operator s Guide. Model 601 Shake Machine With AccuFreeze. Reliability from the team that Serves the Best

1850 Series TRIPLE TREAT Operation Manual

KM-900MAH KM-900MWH KM-900MRH KM-900MRH3

Operator s Manual. Frozen Beverage Granita Machines

user s information manual

AIR CONDITIONER ELECTRONIC CONTROL

HOUSEHOLD FREEZER 048-GM-48303/048-GM-48304/048-GM-48305

Hoshizaki America, Inc.

Instruction Manual. Chest Freezer MODEL: KI130CF2

ICED CAPPUCCINO MACHINE Taylor MODEL: 390

AUTOMATIC WASHER. and. ~o=~ap~c~ty LA7680XM LA7685XM. * -i

Installation and User's Manual for Flake and Nugget Ice Machine. Models FME504, FME804, NME454, NME654

IB450SSP. Built-in Ice Maker with Internal Pump. Owner s Manual

Installation & Operation Instructions

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

FR-1020ARW FR-1020ARS

STRUCTURE ILLUSTRATION...3 IMPORTANT SAFETY INSTRUCTIONS 4 INSTALLATION INSTRUCTION..4 OPERATING YOUR REFRIGERATOR...5-6

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

Viking Use/Installation Guide

Beverage Ice Chests DB, DBC, FB, FBC, 1522 & 2123

Hoshizaki America, Inc.

MANUAL OWNER S. Operating and Servicing Instructions IMPORTANT: READ CAREFULLY BEFORE ASSEMBLY AND USE.

KML-600MAH KML-600MWH KML-600MRH

BOTTOM MOUNT REFRIGERATORS & FREEZERS Installation, Operation and Maintenance Instructions

Hoshizaki America, Inc.

AUTOMATIC DRYERS. Electric Model LE7665XP. Gas Model _ LG7666XP. I and

Symphony Plus 25 and 50 Series Ice and Water Dispensers 25FB425A/W, 50FB425A/W

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

Reliability is a beautiful thing TM CUBELET ICE DISPENSER DCM-500BAF DCM-500BWF DCM-750BAF DCM-750BWF INSTRUCTION MANUAL

Owner s Manual STAINLESS CONICAL CHIMNEY HOOD CONTENTS

Water Boilers ME10EN, ME15EN. Table of Contents

Viking Use & Care Manual

HD150. Introduction. Table of Contents

Transcription:

Whirlpool AUTOMATIC ICE CUBE MAKER User s Instructions & Care and Cleaning Guide MODELS CH E-5R CHS-5R CHE-7R CHS-7R Part No. 585102 Rev. A

General Information When the desired thickness is reached, the ice sheets are released and slide onto a cutter grid where the sheet is The machine produces clear hard ice divided into individual cubes. At the,i by circulating water over a freezing end of each freezing cycle the water plate. As the water freezes into ice, containing the rejected minerals is Cubes fall into the storage bin. When minerals in the water are constantly discharged to the drain. Fresh water the bin is full the ice maker shuts off being rejected and a clear sheet of ice then enters the machine for the next automatically and restarts when the is formed. ice making cycle. ice supply needs replenishing, Turn Clockwise To Increase Thickness The service switch located on the control panel at the top of the machine has three positions. The on position is for the normal ice making cycle. The off position shuts the entire machine off. The clean position is used whenever solutions are circulated through the water system for cleaning. At this position only the water pump operates and the red signal light is lit. The green light indicates power is on to the ice machine. During the ice making cycle the red light will come on if the harvest portion is longer than three minutes. This indicates a malfunction in the normal ice making cycle. The machine may automatically correct the harvest malfunction and resume the normal ice making cycle. This causes the red light to go out. If the red light comes on intermittently or stays on, it indicates a need for qualified service assistance. NOTE: The red light is also on whenever the service switch is in the clean position. This does not indicate a malfunction. MIN. THICKNESS 3/8 MAX. THICKNESS 1 L, Thickness of the ice can be varied by rotation of the inverted L shaped adjusting screw which is located on the thickness control. The thickness control is mounted on the lower freezing plate. One complete rotation of the adjusting screw varies the thickness approximately l/16. To increase thickness turn the screw in a clockwise direction. Maximum production of ice in pounds will be obtained with the control set to produce ice approximately 112 thick. In some areas it may be beneficial to filter or treat the water being supplied to the ice machine to reduce water system maintenance (see Cleaning & Sanitizing the Ice Making System) and to produce the best type of ice. For information on filtering and treating the water see your WHIRLPOOL commercial ice maker dealer.

13 Remove the top water distributor tube. Remove the two wing nuts which hold the distributor tube in position on the top freezing plate. Pull out the water pump hose from the right end of the distributor. Pull out the rubber plug from the left end of the distributor. A stiff bristled brush of approximately the same diameter as the distributor will facilitate removal of scale accumulation. - 6. 7. 8. 9. Preheat the water system by pouring hot water into the reservorr pan until the lower pump housing is covered and circulate for five minutes. Then set service switch to off position to syphon out the water. Then set service switch to clean position. Slowly pour the cleaning solution into the water reservoir pan. If the solution foams, stop pouring until the foam subsides and then continue pouring until the lower pump housing is covered. Allow the solution to circulate until the scale on the freezing plate surface has dissolved. When the plates are clean, place the service switch in the off position. This allows the cleaning solution to syphon out of the reservoir pan into the drain. 14. Remove the ice cube deflectors between each cutter grid. The lower left edge has a locking tab which must clear the grid frame. Push left and up on the lower edge of the deflector. The right edge then readily comes off the lower flange of the cutter grid above. NOTE: Circulating cleaning solution for 20 to 30 minutes will generally remove scale formation. Severe scale formation may require repeating the cleaning process with a fresh quantity of solution since the effectiveness of the solution is drastically reduced after this period of time. If scale deposits remain on the side flanges a stainless steel sponge or pad dipped in cleaning solution can be used to scrub these surfaces. This can best be accomplished after the removal of the lower water distributors. 10 11 Turn on the water supply to the machine and set the service switch to clean. Allow the fresh water to circulate for ten minutes. Place the service switch in the off position and allow the water to syphon off to the drain. When the reservoir pan has refilled with water, place the service switch in the clean position and allow the water to circulate for ten more minutes. 15. Remove the lower water distributors. Lift up on the right side and pull the left edge off of the cutter grid. The plastic distributor may have to be flexed slightly to get if off the grid flange. 12. Place the service switch in the off position and allow the water to syphon off to the drain. Wash the deflectors and distributors with a mrld detergent solution, rinse with clean water and sanitize with the sanitizer solution. If heavy scale exists the components may be soaked in cleaning solution to remove the scale.

18. Wash the ice maker interior with a mild solution of detergent and rinse with fresh water. Then wipe the ice maker interior with the sanitizer solution (see item 1). 19. Reinstall grids, mercury switch, deflectors and distributors. NOTE: Mercury switches are to be positioned as indicated on the sketch located on the support rail. Incorrect position will result in malfunction of the machine. 20 Wash the interior of the bin with a mild solution of detergent, and rinse with fresh water. Then wipe the bin interior with a sanitizing solution made of 100 PPM household bleach. Directions for obtaining solution strength of 100 PPM are on the bleach container. 16. Remove the water reservoir pan. Remove the syphon hose connected to the bottom of the pan. The plastrc pan should then be moved to the left until the right edge can be dropped off the mounting flange. During removal the pan may have to be flexed slightly. 21 Place the service switch to the on position to resume the ice making cycle. 17. Remove each cutter grid. Unplug the electrical connection and pull the mercury switch out of the swinging bracket. Grids are held in position on four studs. Sliding clips free the grid from the studs on the left end and then the grad slides off the studs nearest the freezing plate. The entire grid can be placed into a cleaning solution (see item 1). Allow the grid to soak and use a toothbrush to remove any scale deposit on connecting pins and grid wires. If the ice cube maker is to be shut off for several months, remove all ice from the brn and then Clean & Sanitize the ice maker. Water inlet and drain lines must be blown out if the unit will be subjected to freezing temperatures during shut down. Failure to do so may cause the water inlet or drain line to freeze and rupture. Disconnect electricity to the machine and leave the door cracked open to prevent any odor from develooina.

All components of the ice maker are lubricated at the factory and should not require any additional oiling for the normal life of the machine. Cleaning and sanitizing are not too difficult, Having a qualified service representative clean the system the first time should make subsequent cleaning easier to perform, If the operator wishes to take over this portion of the ice machrne maintenance. Follow this procedure to assure that the ice machine is clean and sanitary: Periodic inspection and cleaning is necessary to keep your ice cube maker operating at peak efficiency and to assure a sanitary ice producing mechanism. Your WHIRLPOOL dealer is well qualified to perform this service for you. Enamel finishes may be cleaned simply by wiping with a damp cloth. Regular use of a good household appliance cleaner and wax is recommended for protecting the finish. Stainless steel cabinets require the use of a stainless steel cleaner. Carbonated water is an excellent cleaner if a regular stainless steel cleaner is not available. Water Cooled Models Over a prolonged period of time scale will form on the Inside walls of the water condenser which must be removed. When scale forms the ice maker becomes less efficient and requires larger amounts of water for cooling. The scale is cleaned from the inside of the condenser walls with chemicals. It is recommended that the scale removal should be performed by your WHIRLPOOL ice maker dealer. Air Cooled Models A dirty or clogged condenser prevents proper air flow resulting in reduced ice capacity and subjecting the unit to higher than normal operating temperatures. A vacuum cleaner and a stiff brush should be used to remove the accumulation of lint and dirt from the finned section of the condenser. NOTE: Condensing units on these models are located on top of the ice making cabinet or may be located in a remote area. 1. Cleaning and sanitizing solutions: Both cleaning and sanitizing solutions are required. Prepare as follows: Cleaning Solution - Mix a solution of 2 l/3 cups powdered citric acid to seven quarts of hot water. Citric acid is available in most drug stores. Hot water should be used if possible as the citric acid will go into solution quicker and the cleaning itself is accomplished in less time. Commercial ice machine cleaners are also available in liquid form and should be mixed according to instructions on the label. These ice machine cleaners are available through commercial refrigeration supply houses. Sanitizer Solution- Mix sodium hypochlorite (common laundry bleach) with water. Follow instructions on the sanitizer container to obtain a solution of 100 PPM available chlorine. 2. Place service switch in off oosition. 3. Remove all ice from the storage bin. 4. Swing the front panel open. If desired the front panel can be lifted off the hinges. If the front panel cannot be opened far enough to lift off the hinges the control panel on top must be removed to provide clearance. The control panel is secured by screws along the bottom front edge. Remove the service switch knob and the panel then is released by pulling forward. CAUTION: Always disconnect electrical power to the machine when removing the control panel cover. 5. With electrical power on and the service switch set to the on position, proceed to: A. Shut off the water supply to the machine. Impurities are rejected from the circulating water that freezes into ice. These impurities collect on the freezing mechanism and in the water system and form a hard scaly deposit. Generally this scale prevents a rapid release of the ice slab during the harvest cycle and may cause the red warning light to indicate intermittently. The water and ice making system, therefore, should be periodically cleaned and sanitized. The frequency of cleaning will depend on local water conditions and how rapidly scale accumulates. B. Lift up gently on the thickness control arm. The water will stop circulating and the water in the reservoir pan will syphon out to the drain. If ice has formed on the freezing plates continue to hold up on the control until the ice sheets clear the freezing plates. C. Release the thickness control and set the service switch to the clean position.

Check the following before calling a serviceman: A. Unit does not run: 1. Make sure service switch is positioned to on. 2. Check fuses in power supply to ice maker head and remote refrigeration unit. NOTE: If green light on control panel is lit, it indicates power supply is okay to ice making section. Separate fuses must be checked for the power to remote refrigeration section. Fuses inside control panel are for low voltage circuits only. B. Unit runs but produces no ice: 1. Check all mercury switches positioned over water trough. Arms must be vertical. If switch arms are not vertical, check for bind. Check position of switch capsule in bracket against sketch on support rail. 2. Turn service switch to off position for one minute and then reset to on position. C. Unit runs but produces very Irttle ice: Operation of remote condensrng unit in extremely high temperatures (normal for ice production to be low). Lint or dirt blocking proper air flow through finned condenser of air cooled condensing unit (check and clean), Check for objects around condensing unit which would obstruct normal air flow. D. Red light on control panel lit: I, Whenever the red light is lit, it is an indication of an abnormally long harvest cycle. Long harvest cycles are generally caused by ice slabs not releasing properly and may indicate the machine needs to be cleaned. NOTE: The red indicator also lights up whenever the service switch is in the clean position. 2. Call a qualified serviceman to check the machine if the above suggestions do not remedy the problem. %2%xralrtp 1 Whirlpool IOR~CCA~lON Benton Harbor, Michigan. Manufacturer of Automatic Washers, Wringer Washers, Clothes Dryers, Freezers, Refrigerators, Refrigerator-freezers, Ice Makers, Dishwashers, Built-In Ovens and Surface Units, Ranges, Food Waste Disposers, Central Vacuum Systems. Dehumidifiers, Air Conditioners. Part No. 585102 Rev. A Printed in U.S.A. Whirlpool Corporate Printing Services