STANDARD FEATURES NEW Factory authorized startup ENERGY STAR Qualified (EUCC6 & EUCC8 only) Exclusive Dual Technology All-purpose 4 -wide peg belt Dish capacities up to 6,495 dishes per hour (NSF Listed) Automatic tank fill Chemical dispensing equipment connection provisions Choice of tank heat: electric, steam coils or direct steam injectors Common hot water connection Common drain connection Common electric connection (separate connection required for optional electric booster and blower-dryer) One piece stainless steel wash/rinse manifold system, easy to remove Door safety switch Electric eye energy sentinel (idle pump shut-off) Easy-to-reach top-mounted controls Heavy-gauge stainless construction Low-water tank heat protection Push-button start-stop station load end Recirculating flushing nozzles load end with prewash saver device Conveyor shut-off shelf unload end Stainless steel enclosure panels front & ends Vent fan control connection provided OPTIONAL WORLD CLASS FEATURES Heat Recovery - redirects lost steam to heat using less energy Project Item No. Quantity EUCC SERIES Upright Conveyor Dual SPECIFIER STATEMENT Photo is for general visual representation only. Please refer to specifications for the latest detailed product information. A compact footprint that also reduces energy consumption by more than 58% Specified unit will be Champion model EUCC4, EUCC6 or EUCC8 upright conveyor water saver dishwashing machine. Features automatic tank fill, chemical dispensing connection provisions, common water, drain and electrical connections, door safety switch, low water tank heat protection, rinse saver. year parts and labor warranty. EUCC SERIES UPRIGHT CONVEYORS The Dual feature offers the Lowest Water/Utility/Chemical Consumption as low as GPH usage while circulating as much as 40+ gallons of water for Consistently Good Results CH089 674 N. Service Road, Jordan Station, Ontario, Canada L0R S0 Tel: 905-56-495 Fax: 905/56-468 (M) /5 Printed in U.S.A. Champion Industries, Inc. 765 Champion Boulevard, Winston-Salem, NC 705 Tel: 6/66-556 Fax: 6/66-979 www.championindustries.com Champion, an Ali Group Company
Upright Conveyor Dual EUCC4 MODULAR SECTIONS: Right to Left Operation 9'- CL-CL [845] 5'-8" [77] Dimensions shown in inches and [millimeters] '-" [65] '-0" [559] 6" [5] 6" [406] -5/8" CL [854] 9-/8" [8] CL [60] " [8] 4' [9] Overall Length C 6-/ [667] 6-/ [59] For Screen Removal B Unload 4' [9] "A" Load 7" [79] ' [60] 5-/" [40] '-6" [76] [0] 7" [79] " [05] 9" [48] 00" [540] Door Removal / Dual Prewash 95" [4] Doors Up 6" [94] 0. 8" [965] 6" [7] Machine Height TABLE A - Machine Connection Machine Only - Electric Heat 0-/" [67] 08/60/ 7 00 00 TABLE B - Booster Connection 40 F/ C Rise 5kW Electric Built-in Booster 40/60/ 49 75 75 480/60/ 74 90 90 08/60/ 4 60 60 40/60/ 6 45 45 480/60/ 8 5 5 Machine-steam 70 F/9 C Rise - 5kW Electric Built-in Booster 08/60/ 70 90 90 Contact Factory for additional voltages. 08/60/ 5 5 40/60/ 8 5 5 480/60/ 0 5 5 40/60/ 60 80 80 480/60/ 0 40 40-5/8" [4] Start/Stop Notes: Load Section (A) Standard 5', contains 0" Prewash Prewash also available in a 48" HD section Non-standard load section available in " increments load length 5' (includes 0" prewash) Unload Section (B) Standard 5 ft contains Aux. available in " increments Built in electric booster requires a 5' minimum unload Built in steam booster requires a minimum 6' unload Blow dryer section adds 4' to overall length of machine Champion Industries, Inc., 765 Champion Boulevard, Winston-Salem, NC 705 6/66-556 Fax: 6/66-979 www.championindustries.com 674 N. Service Road, Jordan Station, Ontario, Canada L0R S0 905/56-495 Fax: 905/56-468
Upright Conveyor Dual MODULAR SECTIONS: Right to Left Operation EUCC6 '- CL-CL [454] 5'-8" [77] Dimensions shown in inches and [millimeters] '-" [65] '-0" [559] 6" [5] -5/8" [854] 6" [408] CL " [05] -5/8" [46] CL [60] " [8] 4'[9] Overall Length C 6-/ [667] For Screen Removal 6-/4 [59]" B Unload 6' [89] / A Load ' ' ' '-6" [0] [60] [94] [94] [76] [0] 5-/" [40] 7" [79] 7" [79] " [05] 9" [48] Clear 00" [540] Door Removal / Dual Power Prewash 95" [4] Doors Up 6" [94] 0. 8" [965] 6" Machine Height TABLE A - Machine Connection Machine Only - Electric Heat 0-/" [67] 08/60/ 8 50 50 40/60/ 58 00 00 480/60/ 80 00 00 TABLE B - Booster Connection 40 F/ C Rise 5kW Electric Built-in Booster 08/60/ 4 60 60 40/60/ 6 45 45 480/60/ 8 5 5 Machine-steam 08/60/ 9 40 40 70 F/9 C Rise - 5kW Electric Built-in Booster 08/60/ 70 90 90 Contact Factory for additional voltages. 40/60/ 6 5 5 480/60/ 4 0 0 40/60/ 60 80 80 480/60/ 0 40 40-5/8" [4 Start/Stop Notes: Load Section (A) Standard 5', contains 0" Prewash Prewash also available in a 48" HD section Non-standard load section available in " increments load length 5' (includes 0" prewash) Unload Section (B) Standard 5 ft contains Aux. available in " increments Built in electric booster requires a 5' minimum unload Built in steam booster requires a minimum 6' unload Blow dryer section adds 4' to overall length of machine Champion Industries, Inc., 765 Champion Boulevard, Winston-Salem, NC 705 6/66-556 Fax: 6/66-979 www.championindustries.com 674 N. Service Road, Jordan Station, Ontario, Canada L0R S0 905/56-495 Fax: 905/56-468
Upright Conveyor Dual MODULAR SECTIONS: Right to Left Operation EUCC8 '- [4064] CL-CL 5'-8" [77] Dimensions shown in inches and [millimeters] '-" [65] '-0" [559] 6" [5] 6" [406] -5/8" CL [854] 9-/8" [8] CL [60] Clear " [8] 4' [9] Overall Length C 6-/ [667] For Screen Removal 6-/ [59] B Unload 7" [79] [0] 8' [48] / ' 4' 4' '-6" [60] [9] [9] [76] 5-/" [40] A Load [0] 7" [79] " [05] 9" [48] Clear 00" [540] Door Removal 6" [94] / Dual 0. Power Prewash 8" [965] 95" [4] Doors Up 6" [575] Machine Height 0-/" [67] -5/8" [4] Start/Stop TABLE A - Machine Connection Machine Only - Electric Heat 08/60/ 8 50 50 40/60/ 58 00 00 480/60/ 80 00 00 TABLE B - Booster Connection 40 F/ C Rise 8kW Electric Built-in Booster 08/60/ 44 60 60 40/60/ 8 50 50 480/60/ 9 5 5 Machine-steam 08/60/ 5 5 70 F/9 C Rise - kw Electric Built-in Booster 40/60/ 8 5 5 480/60/ 0 5 5 08/60/ 77 00 00 40/60/ 67 90 90 480/60/ 4 45 45 Notes: Load Section (A) Standard 5', contains 0" Prewash Prewash also available in a 48" HD section Non-standard load section available in " increments load length 5' (includes 0" prewash) Unload Section (B) Standard 5 ft contains Aux. available in " increments Built in electric booster requires a 5' minimum unload Built in steam booster requires a minimum 6' unload Blow dryer section adds 4' to overall length of machine Champion Industries, Inc., 765 Champion Boulevard, Winston-Salem, NC 705 6/66-556 Fax: 6/66-979 www.championindustries.com 674 N. Service Road, Jordan Station, Ontario, Canada L0R S0 905/56-495 Fax: 905/56-468
Upright Conveyor Dual Shipping weight crated: 50 lbs./ft.[68kg./m.] Height with doors up: 95" Height to remove doors: 00" SPECIFICATIONS Capacities EUCC4 EUCC6 EUCC8 Dishes per hr. (NSF rated) 0,47, 6,495 Conveyor speed (ft./min.) 8.0 0..6 Motor horsepower Drive / Hp / Hp / Hp Prewash 0" [76] Hp Hp Hp Prewash 48" [9] Hp Hp Hp Hp Hp Hp Power * N/A Hp Hp Auxiliary /5 Hp /5 Hp /5 Hp Water consumption Gal. per hr. (max. use) 5 4 Temperatures F (min.) 60 50 50 Power (min.)* N/A 60 60 Auxiliary (min.) 65 65 65 Final rinse (min.) 80 80 80 Heating Tank heat Steam Electric tank 5 lbs./hr. 5 kw tank (EUCC4) 5 lbs./hr. 45 kw tank * 00 lbs./hr. 0 kw Auxiliary rinse 50 lbs./hr. 0 kw Electric booster 5 5 6 (kw required for 40 F rise) Electric booster 5 5 8 (kw required for 70 F rise) Steam booster 75 75 80 (lbs./hr. required for 40 F rise) Steam booster 5 5 5 (lbs./hr. required for 70 F rise) Venting CFM, load end 00 CFM, unload end 800 *EUCC4 has no power rinse tank Utilities EUCC4 Electrical Contact factory for specific machine electrical requirements NOTE: Electric booster connection contact Factory Hot Water / NPT 80 F hot water connection. (For machine without built-in booster) Drain " NPT connection, 6 gpm max flow rate 4 Vents A Load end: 00 CFM / S.P. B Unload end: 800 CFM / S.P. With blower-dryer, increase room ventilation by 600 CFM. Utilities EUCC6 Electrical Contact factory for specific machine electrical requirements NOTE: Electric booster connection contact Factory Hot Water / NPT 80 F hot water connection. (For machine without built-in booster) Drain " NPT connection, 6 gpm max flow rate 4 Vents A Load end: 00 CFM / S.P. B Unload end: 800 CFM / S.P. With blower-dryer, increase room ventilation by 600 CFM. Utilities EUCC8 Electrical Contact factory for specific machine electrical requirements NOTE: Electric booster connection contact Factory Hot Water / NPT 80 F hot water connection. (For machine without built-in booster) Drain " NPT connection, 6 gpm max flow rate 4 Vents A Load end: 00 CFM / S.P. B Unload end: 800 CFM / S.P. With blower-dryer, increase room ventilation by 600 CFM. Booster connections may vary. Contact the Factory. Standard Voltages (Specify choice): 08/60/, 40/60/, and 480/60/. Available in -phase only. For non-standard -phase voltages, contact the Factory. Notes Because of the variation in house-supplied water pressure, a water pressure regulating valve (PRV) is needed (water PRV is standard). Steam PRV s may be required for pressure higher than 0 psi. The PRVs can either be purchased from Champion or obtained locally. Warning and electrical connections should be made by qualified personnel who will observe all the applicable plumbing, sanitary, safety codes and the National Electrical Code. Note Water Hammer Arrestor (meeting ASSE-00 standard or equivalent) to be supplied (by others) in common water supply line at service connection. Venting Notes Fabricated duct size: -7/8" x -7/8" (outside dimensions) Champion Industries, Inc., 765 Champion Boulevard, Winston-Salem, NC 705 6/66-556 Fax: 6/66-979 www.championindustries.com 674 N. Service Road, Jordan Station, Ontario, Canada L0R S0 905/56-495 Fax: 905/56-468 Champion, an Ali Group Company
UPRIGHT CONVEYOR EUCC SERIES Upright Conveyor Dual Control Panel OPTIONS & ACCESSORIES Tank heat; choices of electric, steam coil or steam injectors Booster Heaters stainless steel (completely interplumbed, controls are inter-wired) Electric: (40 F rise or 70 F rise) Steam: (40 F or 70 F rise) 48 Blower Dryer, electric or steam (add 4 to overall length) Belts: standard peg belt, flat belt, thermal tray belt, silverware belt, belts with upper cross rods, and other select combination belts Start/Stop station, unload end Back panels, stainless steel Cold water thermostat (for pre-wash) External scrap bucket on 48 pre-wash (standard on 0 pre-wash) External scrap bucket on wash tank Insulated hoods, lower panels Motor pumps, or Hp optional in lieu of Hp on pre-wash Bumper rail, machine mounted Steam pressure regulating valve (unmounted) Drain water tempering kit (mounted) Insulated hinged door Digital Gauges Water leaves booster at 80 F+ and travels to final rinse arms Booster Durable Stainless Steel Start/Stop Switch Heat Recovery Redirects lost steam to heat using less energy. (available on EUCCW6, EUCCW8 and EUCCW4 only) Heated 0 F water travels back to booster 60 F incoming water to machine. Shock arrestor (water) Drain interlocks Heat Recovery Unit redirects lost steam to heat using less energy NEW Champion ION scale prevention system USGBC and related logo is a trademark owned by the U.S. Green Building Council and is used by permission. Champion Industries, Inc., 765 Champion Boulevard, Winston-Salem, NC 705 6/66-556 Fax: 6/66-979 www.championindustries.com 674 N. Service Road, Jordan Station, Ontario, Canada L0R S0 905/56-495 Fax: 905/56-468