EUCC SERIES Upright 24" Conveyor Dual Rinse Dishwashing Machine

Similar documents
EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine

EUCCW SERIES. EUCCW4, EUCCW6 and EUCCW8 Upright 29 Conveyor Dual Rinse Dishwashing Machine. Champion, an Ali Group Company

EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine

Model 80 DRHDPW 44 Single Tank with 36 Heavy Duty Prewash High Temperature Rack Conveyor Dishwashing Machine with

MODEL 86 PW MODEL 86 PW RACK CONVEYOR STANDARD FEATURES SPECIFIER STATEMENT. Project Item No. Quantity

84 Series 84, 106 PW, 110 FFPW, 120 HDPW High-Temperature Rack Conveyor Dishwashing Machine

FT1000 FLIGHT-TYPE DISHWASHER

FT1000S BASE FLIGHT-TYPE DISHWASHER

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

FT900BD FLIGHT-TYPE DISHWASHER

FT900 FLIGHT-TYPE DISHWASHER

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

FT900S FLIGHT-TYPE DISHWASHER

FT900D DUAL RINSE FLIGHT-TYPE DISHWASHER

FT900S FLIGHT-TYPE DISHWASHER

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

FT1000e ENERGY RECOVERY STEAM WITH BLOWER DRYER Flight-Type Dishwashing Machine. FT SERIES FT1000e ENERGY RECOVERY STEAM WITH BLOWER DRYER

FT1000 ENERGY RECOVERY STEAM WITH BLOWER DRYER Flight-Type Dishwashing Machine FT SERIES FT1000 ENERGY RECOVERY STEAM WITH BLOWER DRYER

FT SERIES FT1000e ELECTRIC

FT1000S ENERGY RECOVERY STEAM Flight-Type Dishwashing Machine FT SERIES FT1000S ENERGY RECOVERY STEAM STANDARD FEATURES SPECIFIER STATEMENT

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

Installation Manual. Manual P/N rev. B. PRO Series Standard Rack Conveyor Dishwashers LISTED. Models.

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

B-US 281 LPW HOT WATER SANITIZING FLIGHT-TYPE WAREWASHERS. Standard Features: Options:

CL64T INDUSTRIAL TOTE WASHER

Models. Options. Standard Features. LoH 2 O

Installation Manual. PRO Series Ventless Heat Recovery Rack Conveyor Dishwashers LISTED.

CL64eN-BAS DISHWASHER

CLPS86eN-BAS DISHWASHER

CL64e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

CLPS66e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

C44A/C44AW DISHWASHER

April 1, Price List Schedule. Effective. Page

November 1, Price List Schedule. Effective. Come see our website at.

CL44eN-BAS DISHWASHER

CL64eN-EGR ENERGY RECOVERY/CL64eN-ADV DISHWASHER

CLPS66eN-EGR ENERGY RECOVERY/CLPS66eN-ADV DISHWASHER

STERO SCT-94SC/108SC/120SC CONVEYOR SERIES

CLCS76eN-BAS DISHWASHER

JFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features. JFT Flight Machine

Standard Features. Performance/Capacities

CLCS76eN-EGR ENERGY RECOVERY DISHWASHER

H O B A R T F T F L I G H T - T Y P E W A R E W A S H E R. Energy efficient. Water efficient. Cleaning efficient. So you re efficient.

Operation, Cleaning, and Maintenance Manual

Installation/Operation Manual with Service Replacement Parts. E 2 series High Temperature Upright Conveyor Dishwasher. Models:

Operation. Operation. Hood-type High Temperature Dishwasher LISTED. Model: DH5000 Series

UW50 UTENSIL/PAN WASHER

Operation, Cleaning and Maintenance Manual

Conveyor. AJ-44 Vision Series. Standard Features. Power/Connections. Performance/Capacities

K-400 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR DISHWASHERS

K-86 SERIES HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR WAREWASHERS. Standard Features: Exclusive Features: Options: Models:

K-86 SERIES. Exclusive Features: Standard Features: ENERGY STAR Qualified. Options: Models:

K-66 SERIES HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR WAREWASHERS. Standard Features: Exclusive Features: Options: Models:

K-66 SERIES. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR DISHWASHERS

LXGeR and LXGePR GLASSWASHER

VENTLESS DOOR-TYPE DISHWASHER

The clean solution HOT WATER SANITIZING MULTIPLE-TANK FLIGHT TYPE WAREWASHERS B-M74 SERIES. Special Features: Standard Features: Optional Features:

K-76 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR DISHWASHERS

Machine Serial No. Technical Manual. International Door Dishwasher. February, 1998 Manual P/N Rev.A

K Tronic Series Installation and Start Up Checkout Procedure.

With (FFPR26) Basic With (PR22) With (PR36) 26" Front Feed Model 22" Prewash 36" Prewash Prewash

Installation Manual. PRO Series. Ventless Heat Recovery Rack Conveyor Dishwashers. Models PRO-VHR 80 PRO HD-VHR

Installation/Operation Manual with Service Replacement Parts

Technical Manual. June, Undercounter Dishwasher. Machine Serial No. Model UH-200B UH-200 UH-100B UH-100 UL-100

Tall Hood-type Dishwashers

Version 7 1/ LX

Version 7 1/ LXP

Installation/Operation Manual with Service Replacement Parts

K-64 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR DISHWASHERS

Tall Hood-type Series Dishwasher

hinged tops or hinged doors.

LXeR and LXePR HOT AND COLD

UNDERCOUNTER DISHWASHER

STERO ER-94S/SC RACK CONVEYOR SERIES

SECTION LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION 1.02 SUBMITTALS 1.03 QUALITY ASSURANCE 1.

The clean solution HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR WAREWASHERS K-M54 SERIES. Special Features: Standard Features: Optional Features:

STARTER SHELVING UNITS DOCUMENT HOLDER LEDGES

K-44 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR DISHWASHERS

Nu/Clean 624 XL Touch Screen Inline Aqueous Cleaner Technical Specifications & Pricing

GIRTON CABINET WASHER MODEL 794A

COMMERCIAL DISHWASHER 2016 PRODUCT CATALOG

Product Reference Catalog

Technical Manual. June, Undercounter Dishwasher. Machine Serial No. Model UH-200B UH-200. For machines beginning with Serial no.

STERO SD3. Door-Type Dishwasher MODEL: ML

Champion. Technical Manual. The Dishwashing Machine Specialists. Door-Type Dishwasher. Machine Serial No. February, 2003

AM SELECT WAREWASHER. The ENERGY STAR rated door-type AM Select warewasher is the only warewasher you need.

AM SELECT DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES VOLTAGE. Item # Quantity C.S.I. Section AM15

AM-14/AM-14C DISHWASHERS

TECHNICAL MANUAL INSTALLATION MANUAL FOR EXPORT UNITS SERVICE MANUAL FOR DOMESTIC UNITS FOR JACKSON MODELS: AJ-86CE AJ-86CGP AJ-86CS

R O T O - J E T O F A M E R I C A C O M P A N Y, I N C.

Installation Manual DH6000T-VHR. Ventless Heat Recovery. Manual P/N rev. A

Tall Hood-type Dishwashers

Installation/Operation Manual with Service Replacement Parts. Undercounter Dishwashers M4 Series

BASIL 6000 TUNNEL CAGE WASHER

! ATTENTION INSTALLER! THIS DISHWASHER IS EQUIPPED WITH A CONDENSATE REMOVAL VENT SHROUD WHICH WAS SHIPPED SEPARATELY IN ITS OWN PACKAGING.

Warewashing Contents. NT & TAS - For orders in these states please add 5% transport surcharge to your purchase price

High Temperature Undercounter Dishwasher

Installation/Operation Manual with Service Replacement Parts. Undercounter Dishwashers M4 Series

CLe-series Dishwashers

LXe HOT AND COLD HOT AND COLD MODELS STANDARD FEATURES ACCESSORIES STANDARD VOLTAGES OPTIONS AT EXTRA COST. Item # Quantity C.S.I.

Transcription:

STANDARD FEATURES NEW Factory authorized startup ENERGY STAR Qualified (EUCC6 & EUCC8 only) Exclusive Dual Technology All-purpose 4 -wide peg belt Dish capacities up to 6,495 dishes per hour (NSF Listed) Automatic tank fill Chemical dispensing equipment connection provisions Choice of tank heat: electric, steam coils or direct steam injectors Common hot water connection Common drain connection Common electric connection (separate connection required for optional electric booster and blower-dryer) One piece stainless steel wash/rinse manifold system, easy to remove Door safety switch Electric eye energy sentinel (idle pump shut-off) Easy-to-reach top-mounted controls Heavy-gauge stainless construction Low-water tank heat protection Push-button start-stop station load end Recirculating flushing nozzles load end with prewash saver device Conveyor shut-off shelf unload end Stainless steel enclosure panels front & ends Vent fan control connection provided OPTIONAL WORLD CLASS FEATURES Heat Recovery - redirects lost steam to heat using less energy Project Item No. Quantity EUCC SERIES Upright Conveyor Dual SPECIFIER STATEMENT Photo is for general visual representation only. Please refer to specifications for the latest detailed product information. A compact footprint that also reduces energy consumption by more than 58% Specified unit will be Champion model EUCC4, EUCC6 or EUCC8 upright conveyor water saver dishwashing machine. Features automatic tank fill, chemical dispensing connection provisions, common water, drain and electrical connections, door safety switch, low water tank heat protection, rinse saver. year parts and labor warranty. EUCC SERIES UPRIGHT CONVEYORS The Dual feature offers the Lowest Water/Utility/Chemical Consumption as low as GPH usage while circulating as much as 40+ gallons of water for Consistently Good Results CH089 674 N. Service Road, Jordan Station, Ontario, Canada L0R S0 Tel: 905-56-495 Fax: 905/56-468 (M) /5 Printed in U.S.A. Champion Industries, Inc. 765 Champion Boulevard, Winston-Salem, NC 705 Tel: 6/66-556 Fax: 6/66-979 www.championindustries.com Champion, an Ali Group Company

Upright Conveyor Dual EUCC4 MODULAR SECTIONS: Right to Left Operation 9'- CL-CL [845] 5'-8" [77] Dimensions shown in inches and [millimeters] '-" [65] '-0" [559] 6" [5] 6" [406] -5/8" CL [854] 9-/8" [8] CL [60] " [8] 4' [9] Overall Length C 6-/ [667] 6-/ [59] For Screen Removal B Unload 4' [9] "A" Load 7" [79] ' [60] 5-/" [40] '-6" [76] [0] 7" [79] " [05] 9" [48] 00" [540] Door Removal / Dual Prewash 95" [4] Doors Up 6" [94] 0. 8" [965] 6" [7] Machine Height TABLE A - Machine Connection Machine Only - Electric Heat 0-/" [67] 08/60/ 7 00 00 TABLE B - Booster Connection 40 F/ C Rise 5kW Electric Built-in Booster 40/60/ 49 75 75 480/60/ 74 90 90 08/60/ 4 60 60 40/60/ 6 45 45 480/60/ 8 5 5 Machine-steam 70 F/9 C Rise - 5kW Electric Built-in Booster 08/60/ 70 90 90 Contact Factory for additional voltages. 08/60/ 5 5 40/60/ 8 5 5 480/60/ 0 5 5 40/60/ 60 80 80 480/60/ 0 40 40-5/8" [4] Start/Stop Notes: Load Section (A) Standard 5', contains 0" Prewash Prewash also available in a 48" HD section Non-standard load section available in " increments load length 5' (includes 0" prewash) Unload Section (B) Standard 5 ft contains Aux. available in " increments Built in electric booster requires a 5' minimum unload Built in steam booster requires a minimum 6' unload Blow dryer section adds 4' to overall length of machine Champion Industries, Inc., 765 Champion Boulevard, Winston-Salem, NC 705 6/66-556 Fax: 6/66-979 www.championindustries.com 674 N. Service Road, Jordan Station, Ontario, Canada L0R S0 905/56-495 Fax: 905/56-468

Upright Conveyor Dual MODULAR SECTIONS: Right to Left Operation EUCC6 '- CL-CL [454] 5'-8" [77] Dimensions shown in inches and [millimeters] '-" [65] '-0" [559] 6" [5] -5/8" [854] 6" [408] CL " [05] -5/8" [46] CL [60] " [8] 4'[9] Overall Length C 6-/ [667] For Screen Removal 6-/4 [59]" B Unload 6' [89] / A Load ' ' ' '-6" [0] [60] [94] [94] [76] [0] 5-/" [40] 7" [79] 7" [79] " [05] 9" [48] Clear 00" [540] Door Removal / Dual Power Prewash 95" [4] Doors Up 6" [94] 0. 8" [965] 6" Machine Height TABLE A - Machine Connection Machine Only - Electric Heat 0-/" [67] 08/60/ 8 50 50 40/60/ 58 00 00 480/60/ 80 00 00 TABLE B - Booster Connection 40 F/ C Rise 5kW Electric Built-in Booster 08/60/ 4 60 60 40/60/ 6 45 45 480/60/ 8 5 5 Machine-steam 08/60/ 9 40 40 70 F/9 C Rise - 5kW Electric Built-in Booster 08/60/ 70 90 90 Contact Factory for additional voltages. 40/60/ 6 5 5 480/60/ 4 0 0 40/60/ 60 80 80 480/60/ 0 40 40-5/8" [4 Start/Stop Notes: Load Section (A) Standard 5', contains 0" Prewash Prewash also available in a 48" HD section Non-standard load section available in " increments load length 5' (includes 0" prewash) Unload Section (B) Standard 5 ft contains Aux. available in " increments Built in electric booster requires a 5' minimum unload Built in steam booster requires a minimum 6' unload Blow dryer section adds 4' to overall length of machine Champion Industries, Inc., 765 Champion Boulevard, Winston-Salem, NC 705 6/66-556 Fax: 6/66-979 www.championindustries.com 674 N. Service Road, Jordan Station, Ontario, Canada L0R S0 905/56-495 Fax: 905/56-468

Upright Conveyor Dual MODULAR SECTIONS: Right to Left Operation EUCC8 '- [4064] CL-CL 5'-8" [77] Dimensions shown in inches and [millimeters] '-" [65] '-0" [559] 6" [5] 6" [406] -5/8" CL [854] 9-/8" [8] CL [60] Clear " [8] 4' [9] Overall Length C 6-/ [667] For Screen Removal 6-/ [59] B Unload 7" [79] [0] 8' [48] / ' 4' 4' '-6" [60] [9] [9] [76] 5-/" [40] A Load [0] 7" [79] " [05] 9" [48] Clear 00" [540] Door Removal 6" [94] / Dual 0. Power Prewash 8" [965] 95" [4] Doors Up 6" [575] Machine Height 0-/" [67] -5/8" [4] Start/Stop TABLE A - Machine Connection Machine Only - Electric Heat 08/60/ 8 50 50 40/60/ 58 00 00 480/60/ 80 00 00 TABLE B - Booster Connection 40 F/ C Rise 8kW Electric Built-in Booster 08/60/ 44 60 60 40/60/ 8 50 50 480/60/ 9 5 5 Machine-steam 08/60/ 5 5 70 F/9 C Rise - kw Electric Built-in Booster 40/60/ 8 5 5 480/60/ 0 5 5 08/60/ 77 00 00 40/60/ 67 90 90 480/60/ 4 45 45 Notes: Load Section (A) Standard 5', contains 0" Prewash Prewash also available in a 48" HD section Non-standard load section available in " increments load length 5' (includes 0" prewash) Unload Section (B) Standard 5 ft contains Aux. available in " increments Built in electric booster requires a 5' minimum unload Built in steam booster requires a minimum 6' unload Blow dryer section adds 4' to overall length of machine Champion Industries, Inc., 765 Champion Boulevard, Winston-Salem, NC 705 6/66-556 Fax: 6/66-979 www.championindustries.com 674 N. Service Road, Jordan Station, Ontario, Canada L0R S0 905/56-495 Fax: 905/56-468

Upright Conveyor Dual Shipping weight crated: 50 lbs./ft.[68kg./m.] Height with doors up: 95" Height to remove doors: 00" SPECIFICATIONS Capacities EUCC4 EUCC6 EUCC8 Dishes per hr. (NSF rated) 0,47, 6,495 Conveyor speed (ft./min.) 8.0 0..6 Motor horsepower Drive / Hp / Hp / Hp Prewash 0" [76] Hp Hp Hp Prewash 48" [9] Hp Hp Hp Hp Hp Hp Power * N/A Hp Hp Auxiliary /5 Hp /5 Hp /5 Hp Water consumption Gal. per hr. (max. use) 5 4 Temperatures F (min.) 60 50 50 Power (min.)* N/A 60 60 Auxiliary (min.) 65 65 65 Final rinse (min.) 80 80 80 Heating Tank heat Steam Electric tank 5 lbs./hr. 5 kw tank (EUCC4) 5 lbs./hr. 45 kw tank * 00 lbs./hr. 0 kw Auxiliary rinse 50 lbs./hr. 0 kw Electric booster 5 5 6 (kw required for 40 F rise) Electric booster 5 5 8 (kw required for 70 F rise) Steam booster 75 75 80 (lbs./hr. required for 40 F rise) Steam booster 5 5 5 (lbs./hr. required for 70 F rise) Venting CFM, load end 00 CFM, unload end 800 *EUCC4 has no power rinse tank Utilities EUCC4 Electrical Contact factory for specific machine electrical requirements NOTE: Electric booster connection contact Factory Hot Water / NPT 80 F hot water connection. (For machine without built-in booster) Drain " NPT connection, 6 gpm max flow rate 4 Vents A Load end: 00 CFM / S.P. B Unload end: 800 CFM / S.P. With blower-dryer, increase room ventilation by 600 CFM. Utilities EUCC6 Electrical Contact factory for specific machine electrical requirements NOTE: Electric booster connection contact Factory Hot Water / NPT 80 F hot water connection. (For machine without built-in booster) Drain " NPT connection, 6 gpm max flow rate 4 Vents A Load end: 00 CFM / S.P. B Unload end: 800 CFM / S.P. With blower-dryer, increase room ventilation by 600 CFM. Utilities EUCC8 Electrical Contact factory for specific machine electrical requirements NOTE: Electric booster connection contact Factory Hot Water / NPT 80 F hot water connection. (For machine without built-in booster) Drain " NPT connection, 6 gpm max flow rate 4 Vents A Load end: 00 CFM / S.P. B Unload end: 800 CFM / S.P. With blower-dryer, increase room ventilation by 600 CFM. Booster connections may vary. Contact the Factory. Standard Voltages (Specify choice): 08/60/, 40/60/, and 480/60/. Available in -phase only. For non-standard -phase voltages, contact the Factory. Notes Because of the variation in house-supplied water pressure, a water pressure regulating valve (PRV) is needed (water PRV is standard). Steam PRV s may be required for pressure higher than 0 psi. The PRVs can either be purchased from Champion or obtained locally. Warning and electrical connections should be made by qualified personnel who will observe all the applicable plumbing, sanitary, safety codes and the National Electrical Code. Note Water Hammer Arrestor (meeting ASSE-00 standard or equivalent) to be supplied (by others) in common water supply line at service connection. Venting Notes Fabricated duct size: -7/8" x -7/8" (outside dimensions) Champion Industries, Inc., 765 Champion Boulevard, Winston-Salem, NC 705 6/66-556 Fax: 6/66-979 www.championindustries.com 674 N. Service Road, Jordan Station, Ontario, Canada L0R S0 905/56-495 Fax: 905/56-468 Champion, an Ali Group Company

UPRIGHT CONVEYOR EUCC SERIES Upright Conveyor Dual Control Panel OPTIONS & ACCESSORIES Tank heat; choices of electric, steam coil or steam injectors Booster Heaters stainless steel (completely interplumbed, controls are inter-wired) Electric: (40 F rise or 70 F rise) Steam: (40 F or 70 F rise) 48 Blower Dryer, electric or steam (add 4 to overall length) Belts: standard peg belt, flat belt, thermal tray belt, silverware belt, belts with upper cross rods, and other select combination belts Start/Stop station, unload end Back panels, stainless steel Cold water thermostat (for pre-wash) External scrap bucket on 48 pre-wash (standard on 0 pre-wash) External scrap bucket on wash tank Insulated hoods, lower panels Motor pumps, or Hp optional in lieu of Hp on pre-wash Bumper rail, machine mounted Steam pressure regulating valve (unmounted) Drain water tempering kit (mounted) Insulated hinged door Digital Gauges Water leaves booster at 80 F+ and travels to final rinse arms Booster Durable Stainless Steel Start/Stop Switch Heat Recovery Redirects lost steam to heat using less energy. (available on EUCCW6, EUCCW8 and EUCCW4 only) Heated 0 F water travels back to booster 60 F incoming water to machine. Shock arrestor (water) Drain interlocks Heat Recovery Unit redirects lost steam to heat using less energy NEW Champion ION scale prevention system USGBC and related logo is a trademark owned by the U.S. Green Building Council and is used by permission. Champion Industries, Inc., 765 Champion Boulevard, Winston-Salem, NC 705 6/66-556 Fax: 6/66-979 www.championindustries.com 674 N. Service Road, Jordan Station, Ontario, Canada L0R S0 905/56-495 Fax: 905/56-468