NESLAB CB 60/CB 80 Cryobaths. Operation. Product Service Information, Applications Notes, MSDS Forms, .

Similar documents
CFC-FREE CB-60/CB-80 Cryobath Low Temperature Bath. Thermo NESLAB Manual P/N U00551 Rev. 04/03/00. Instruction and Operation Manual

FTC-350A. ual. Instruction and Operation Manual. Thermo NESLAB Manual P/N Rev. 11/08/00

RTE-5/5B & RTE-9/9B Refrigerated Bath Circulators. NESLAB Manual P/N Installation, Operation and Service Manual

HX-900 Recirculating Chiller

HX-1000 & HX-2000 Recirculating Chiller. NESLAB Manual P/N Rev 03/19/97. Instruction and Site Preparation Manual

HX Series Recirculating Chiller Remote Condenser

HX-1000 & HX-2000 Recirculating Chiller TC-400 Controller

NESLAB HX Recirculating Chillers. Installation Operation Basic Maintenance

Reacti-Therm I and III Heating/Stirring Modules

HX Digital Recirculating Chiller

Hi-Temp Bath Installation and Operation Manual

Reacti-Therm I and III Heating Modules

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

Operator s Manual. Histology Bath

InstructIon Manual KrEs EQuIPMEnt stands

Superdryer Dehumidifiers

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0

Instruction Manual. Mini Hotplate Mini Stirrer Mini Hotplate Stirrer

Operator s Manual. IP-100 Immersion Probe Cooler

Professional Warming Drawer and Warming Drawer Cabinet

HOT DOG STEAMER Instruction Manual Models: 8007 & 8012

USER MANUAL SAVE THESE INSTRUCTIONS

Instruction Manual. Double Candy Apple Cooker

Hot Dog Roller Grills

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate

Instruction Manual. Nacho Cheese Dispenser and Warmer

CFT Series Recirculating Chiller. NESLAB Manual P/N U00362 Rev. 08/18/99. Instruction and Operation Manual

OPERATING INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Owner & Operator s Manual. Table of Contents

Air Pump Up to 800 gallons

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

Cavitator Ultrasonic Cleaners

Outdoor/Commercial Refrigerator USER S MANUAL

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL

INSTRUCTION MANUAL HS-229G

Ui REFRIGERATOR SPEC SHEET

IMPORTANT SAFETY INFORMATION:

Warmer Cabinet Instruction Manual Model # 5581, 5581EX. Part No

Power Pack Service Manual

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

Power Pack Service Manual

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

Instruction Manual. Cheese Warmer with Pump

Operation Manual Vortex mixer unitexer 1

CH250 AND CH251 CHILLERS

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

IMPORTANT SAFETY INFORMATION:

INSTALLATION & OPERATING INSTRUCTIONS

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

Econo-16 Models 2024EX, 2024STX 16oz. Popcorn Machine Instruction Manual

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

Ice Cream Freezer Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

INSTALLATION AND OPERATING MANUAL

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

Cavitator Ultrasonic Cleaner Instruction Manual

VT SERIES VERTICAL TOASTER OPERATOR S MANUAL TABLE OF CONTENTS

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

INSTRUCTIONN MANUAL. for Angle Curved MMF9106 MMF9109 MMF9112

Quality Refrigeration OWNER S MANUAL. Instructions for the installation, operation and maintenance of Traulsen: Heated Banquet & Transport Carts

IMPORTANT SAFETY INFORMATION:

Dear Valued Customer:

Industrial Dehumidifier Operating Instructions. Model: VG 1500

INSTALLATION AND OPERATING MANUAL

IMPORTANT SAFETY INFORMATION:

INSTALLATION AND OPERATING MANUAL

20 High velocity Air

NoZone Ozone Scrubber

Owner s Manual PUH1500. Electric Umbrella Heater. Model Number: Model Number Part Number. Quality checked by: R00

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

Horizontal Bottle Cooler Installation and Operation Manual

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Pressurized Filter Up to 1250 gallons

Outdoor Refrigerator USER S MANUAL

Instruction Manual for the Chefmate Countertop Soup Warmer Model CPSKB1

Instruction Manual. Portion Cup Cheese Warmer

IMPORTANT SAFETY INFORMATION:

Instruction Manual. Carmel Apple-Dip Warmer

6 Sheet Strip-Cut Shredder for Home/Office

DROP IN POPCORN WARMERS

Cincinnati, OH USA

Instruction Manual. Bucket Oil Pump

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

Owner s Manual. Terpene Trap CF 1000

OWNER S MANUAL. Installation Operation Maintenance. Saturn Equipment

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Installation and Owner Man u al

75 Sheet Micro-Cut Shredder With CD/DVD Slot

INSTALLATION AND OPERATING MANUAL

Drain Tempering Reservoir READ & SAVE THESE INSTRUCTIONS. Installation, Operation, & Maintenance. TRION

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

Transcription:

Thermo Scientific NESLAB CB 60/CB 80 Cryobaths Thermo Scientific Manual P/N U0055 Rev. 01/04/07 Operation Visit our Web site at: http://www.thermofisher.com/tc Product Service Information, Applications Notes, MSDS Forms, e-mail. Voice Info: (800) 258-0830

Thermo Fisher Scientific 25 Nimble Hill Road Newington, NH 03801 Tel : (800) 258-0830 or (603) 436-9444 Fax : (603) 436-8411 www.thermofisher.com/tc Sales, Service, and Customer Support 25 Nimble Hill Road Newington, NH 03801 Tel: (800) 258-0830 Sales: 8:00 am to 5:00 pm Service and Support: 8:00 am to 6:00 pm Monday through Friday (Eastern Time) Fax: (603) 436-8411 service.tc.us@thermofisher.com Dieselstrasse 4 D-76227 Karlsruhe, Germany Tel : +49 (0) 721 4094 444 Fax : +49 (0) 721 4094 300 info.tc.de@thermofisher.com Building 6, No. 27 Xin Jinqiao Rd., Shanghai 201206 Tel : +86(21) 68654588 Fax : +86(21) 64457830 info.china@thermofisher.com Statement of Copyright Copyright 2007 Thermo Fisher Scientific. All rights reserved. This manual is copyrighted by Thermo Fisher Scientific. Users are forbidden to reproduce, republish, redistribute, or resell any materials from this manual in either machine-readable form or any other form.

NESLAB CB 60/CB 80 Cryobath Low Temperature Table of Contents PREFACE Compliance... 2 WEEE/RoHS... 2 After-sale Support... 3 Unpacking... 3 Out of Box Failure... 3 Warranty... 3 Feedback... 3 SECTION I Safety SECTION II General Information SECTION III Installation SECTION IV Operation SECTION V Maintenance and Service SECTION VI Troubleshooting Warnings... 4 Description... 5 Specifications... 5 Site... 6 Electrical Requirements... 6 Fluids... 7 Filling Requirements... 7 Bath Parts... 7 Mounting Brackets... 8 Start Up... 9 Temperature Adjustment... 9 Stirring... 9 Service Contracts... 11 Cleaning... 11 Cooling Fluid... 11 Checklist... 12 Service Assistance... 12 Technical Assistance... 12 SECTION VIII Warranty... 13-1 -

Compliance WEEE/RoHS Preface Products tested and found to be in compliance with the requirements defined in the EMC standards defined by 89/336/EEC as well as Low Voltage Directive (LVD) 73/23/ EEC can be identified by the CE Mark on the rear of the unit. The testing has demonstrated compliance with the following directives: LVD, 73/23/EEC Complies with IEC/EN61010-1 EMC, 89/336/EEC IEC/EN61326-1 For any additional information, refer to the Declaration of Conformity that shipped with the unit. This product is required to comply with the European Union s Waste Electrical & Electronic Equipment (WEEE) Directive 2002/96/EC. It is marked with the following symbol: Thermo Fisher Scientific has contracted with one or more recycling/disposal companies in each EU Member State, and this product should be disposed of or recycled through them. Further information on Thermo Fisher Scientific s compliance with these Directives, the recyclers in your country, and information on Thermo Scientific products which may assist the detection of substances subject to the RoHS Directive are available at: www.thermo.com/weeerohs - 2 -

After-sale Support Unpacking Thermo Fisher Scientific is committed to customer service both during and after the sale. If you have questions concerning the operation of your unit or the information in this manual, contact our Sales Department. If your unit fails to operate properly or if you have questions concerning spare parts or Service Contracts, contact our Service Department. Before calling, please refer to the serial number label on the rear of the case top to obtain the following information: - BOM number - Serial number Retain all cartons and packing material until the unit is operated and found to be in good condition. If the unit shows external or internal damage contact the transportation company and file a damage claim. Under ICC regulations, this is your responsibility. Out of Box Failure Warranty An Out of Box Failure is defined as any product that fails to operate in conformance with sellers published specifications at initial power up. The unit must be installed in accordance with manufacturer's recommended operating conditions within 30 days of shipment from the seller. Any Temperature Control product meeting the definition of an Out of Box Failure must be packed and shipped back in the original packaging to Thermo Fisher Scientific for replacement with a new unit; Seller to pay the cost of shipping. Customer must receive a Return Material Authorization (RMA) from Thermo Fisher prior to shipping the unit. Units have a warranty against defective parts and workmanship for one full year from date of shipment. See back page for more details. Feedback We appreciate any feedback you can give us on this manual. Please e-mail us at neslabmanuals@thermofisher.com. Be sure to include the manual part number and the revision date listed on the front cover. - 3 -

Section I Safety Warnings Make sure you read and understand all instructions and safety precautions listed in this manual before installing or operating your unit. If you have any questions concerning the operation of your unit or the information in this manual, contact our Sales Department. Performance of installation, operation, or maintenance procedures other than those described in this manual may result in a hazardous situation and may void the manufacturer s warranty. Transport the unit with care. Sudden jolts or drops can damage the refrigeration lines. Observe all warning labels. Never remove warning labels. Never operate damaged or leaking equipment. Always turn off the unit and disconnect the line cord from the power source before performing any service or maintenance procedures, or before moving the unit. Always empty the bath before moving the unit. Never operate equipment with damaged line cords. Never operate the unit without fluid in the bath. Refer service and repairs to a qualified technician. In addition to the safety warnings listed above, warnings are posted throughout the manual. These warnings are designated by an exclamation mark inside an equilateral triangle with text highlighted in bold print. Read and follow these important instructions. Failure to observe these instructions can result in permanent damage to the unit, significant property damage, or personal injury or death. - 4 -

Section II General Information Description The NESLAB CB 60/CB 80 Cryobath low temperature baths are designed to be an all purpose cold bath providing continuous operation at temperatures as low as -50 C (-80 C for the CB 80). Temperature stability of ±0.5 C can be obtained by using the optional NESLAB Cryotrol Temperature Controller. Each unit consists of an air-cooled refrigeration system, a magnetic stirring mechanism, a stainless steel bath, bath parts, a gasketed PVC bath cover, and stainless steel brackets for mounting auxiliary equipment. Specifications Lowest Temperature 1 Temperature Stability 2 Cooling Capacity 3 60Hz 50Hz Bath Work Area (Diameter x Depth) Inches Centimeters Bath Volume Gallons Liters Unit Dimensions (H x W x D) Inches Centimeters Shipping Weight Pounds Kilograms CB 60-50 C ±0.5 C 75 Watts @ -30 C 60 Watts @ -30 C 6 ½ x 6 3 /16 16.5 x 15.7 1.0 3.8 19¾ x 11¾ x 13¾ 50.2 x 29.8 x 34.9 75 34 CB 80-80 C ±0.5 C 120 Watts @ -50 C 100 Watts @ -50 C 7 ¾ x 7 5 /8 19.7 x 19.5 2.0 7.6 40 x 16 x 22½ 101.6 x 40.6 x 57.2 176 80 1. Under no heat load. Temperatures will vary with use of magnetic stirrer. 2. Using optional Cryotrol Temperature Controller. 3. Operating using bath fluid with specific heat of 0.5. - 5 -

Section III Installation Site Locate the unit on a sturdy table or bench top. Ambient temperatures should be within the range of +55 F to +95 F (+13 C to +35 C). Ambient Temperature Range 13 C to 35 C (55 F to 95 F) Overvoltage Category II Pollution Degree 2 Never place the unit in a location where excessive heat, moisture, or corrosive materials are present. The unit has an air-cooled refrigeration system. Air is drawn through front of the unit and discharged through the rear. The unit must be positioned so the air intake and discharge are not impeded. A minimum clearance of 12 inches (30 centimeters) on the front and rear of the unit is necessary for adequate ventilation. Inadequate ventilation will cause a reduction in cooling capacity and, in extreme cases, compressor failure. Excessively dusty areas should be avoided and a periodic cleaning schedule should be instituted (see Section VI, Cleaning). The unit will retain its full rated capacity in ambient temperatures to approximately +75 F (+24 C). Reduce the cooling capacity 1% for every 1 F above +75 F, to a maximum ambient temperature of +95 F. In C, reduce the cooling capacity 1% for every 0.5 C above +24 C, to a maximum ambient temperature of +35 C. Electrical Requirements The unit construction provides protection against the risk of electrical shock by grounding appropriate metal parts. The protection may not function unless the power cord in connected to a properly grounded outlet. It is the user s responsibility to assure a proper ground connection is provided. Refer to the serial number label on the rear of the unit to identify the specific electrical requirements of your unit. Make sure the voltage of the power source meets the specified voltage, ±10%. - 6 -

Fluids Never use flammable or corrosive fluids with this unit. A non-freezing fluid is required. The selected fluid must have a viscosity of 50 centistokes or less at the lowest operating temperature. Filling Requirements Bath Parts Fill the bath to within 1 inch of the top. The bath parts are the glass plate, spin bar, and stainless steel baffle that are included with the unit. The installation of the bath parts is necessary for proper operation. Place the glass plate in the bottom of the bath. The glass plate prevents the spin bar from wearing a hole in the bottom of the bath. Set the spin bar on the glass plate and the stainless steel baffle over the spin bar and coils. The feet of the baffle should rest on the bottom of the bath. Cover Stainless Steel Baffle Spin Bar Glass Plate Replacement bath parts are available from Thermo Scientific. Contact our Sales Department for more information (see Preface, After-Sale Support). - 7 -

Mounting Brackets The unit is equipped with two stainless steel mounting brackets (not installed) that are designed to allow auxiliary equipment to be mounted on the unit. Installation of the mounting brackets is optional. Locate the four screws on the unit. The CB 60 screws are on the rear of the unit, for the CB 80 they are on the sides. Remove the screws. Align the holes in the brackets with the screw holes in the unit. Secure the brackets using the original screws. CB-60 CB 80-8 -

Section IV Operation Start Up Before starting the unit, double check all electrical connections and make sure the bath has been properly filled with cooling fluid. All the functions of the unit are governed by front panel controls. The upper COOLING ON/OFF switch controls power to the refrigeration system and the Cryotrol receptacle. To start the unit, place the COOLING ON/OFF switch in the ON position. The green light behind the switch will light. Once the unit is on, the refrigeration system will reduce the temperature of the cooling fluid to the lowest achievable temperature under the existing heat load conditions. When the unit is shut off, wait approximately five minutes before restarting. This allows time for the refrigeration pressures to equalize. If the pressures are not allowed to equalize, the compressor will short-cycle (clicking sound) and no cooling will occur. Temperature Adjustment If temperature control is desired, a Cryotrol Temperature Controller is required. Refer to the Cryotrol Temperature Controller Instruction and Operation Manual for installation and operation instructions. The CB 60/CB 80 is designed for continuous low temperature operation. Do not operate either unit above -25 C. CB 60-9 -

CB-80 Stirring The lower switch, labelled STIRRER ON OFF, controls power to the stirring mechanism in the unit. Power to the stirring mechanism is independent from the COOLING ON OFF switch; the stirrer can operate if the COOLING ON OFF switch is in the OFF position. The knob labelled SPEED controls the speed of the stirring mechanism. The speed is adjustable from 0 to 1000 RPM. Turn the knob clockwise to increase the speed. The knob labelled TORQUE controls the power of the stirring mechanism. Turn the knob clockwise to increase the power. Adjustments to the power may be required to maintain proper stirring in the bath as the cooling fluid becomes more viscous. NOTE: The heat input in the bath increases as the torque increases. To ensure maximum cooling capacity, use the minimum power (torque) needed to maintain adequate stirring. The knob labelled REVERSE, controls the period of the reversing feature of the stirring mechanism. The reversing feature automatically reverses the direction of stirring to minimize vortexing in the bath. Turn the knob fully counterclockwise to disable the reversing feature. Turn the knob clockwise to decrease the period of reversing and increase the speed (RPM). - 10 -

Section V Maintenance and Service Service Contracts Thermo Fisher Scientific offers on-site Service Contracts that are designed to provide extended life and minimal down-time for your unit. For more information, contact our Service Department (see Preface, After-sale Support). Always turn the unit off and disconnect the line cord from the power source before performing any service or maintenance procedures. Cleaning Condenser The unit pulls substantial amounts of air through a finned condenser. A build up of dust or debris on the fins of the heat exchanger will cause a reduction in cooling capacity, and, in extreme cases, compressor failure. Periodic vacuuming of the heat exchanger is necessary. The frequency of cleaning depends on the operating environment. We recommend making a monthly visual inspection of the heat exchanger after initial installation. After several months, the cleaning frequency will be established. Bath Periodically clean the case and stainless steel bath using a mild soapy solution. Do not use steel wool; it is too abrasive and can initiate rusting. Dry the bath using a soft cloth. Cooling Fluid The cooling fluid should be replaced periodically when operating at low temperatures. The concentration of water in the cooling fluid will increase over time, causing a reduction in cooling capacity. Refer to Section III, Filling Requirements for cooling fluid instructions. - 11 -

Section VI Troubleshooting Checklist Unit will not start. Check power source. Refer to the serial number label on the rear of the unit for the specific electrical requirements of your unit. Make sure the voltage of the power source meets the specified voltage, ±10% (see Section III, Electrical Requirements). Unit will not cool. Make sure the unit has adequate ventilation. Air is drawn through the front of the unit and discharged through the rear. The unit must be positioned so the intake and discharge are not impeded. A minimum clearance of 12 inches (30 centimeters) on the front and rear of the unit is necessary for adequate ventilation. Inadequate ventilation will cause a reduction in cooling capacity, and, in extreme cases, compressor failure (see Section III, Site; Section V, Cleaning). When the unit is shut off, wait approximately five minutes before restarting. This allows time for the refrigeration pressures to equalize. If the pressures are not allowed to equalize, the compressor will short-cycle (clicking sound) and no cooling will occur (see Section IV, Operation). Check for ice build up in the bath. If ice has accumulated, replace the cooling fluid (see Section V, Cleaning). Spin bar does not operate. Contact Thermo Fisher Scientific's service department. Service Assistance If, after following these troubleshooting steps, your units fails to operate properly, contact our Service Department for assistance (see Preface, Aftersale Support). Before calling, please obtain the following information: Part number Serial number Voltage of unit Voltage of power source Ambient temperature where unit is located Technical Support Our Service Department can provide you with a wiring diagram and complete list of spare parts for your unit (see Preface, After-sale Support). Before calling, please obtain the following information: Part number Serial number - 12 -

WARRANTY Thermo Fisher Scientific warrants for 12 months from date of shipment any Thermo Scientific product according to the following terms. Any part of the unit manufactured or supplied by Thermo Fisher and found in the reasonable judgment of Thermo Fisher to be defective in material or workmanship will be repaired at an authorized Thermo Scientific Product Repair Depot without charge for parts or labor. The unit, including any defective part must be returned to an authorized Thermo Scientific Product Repair Depot within the warranty period. The expense of returning the unit to the authorized Thermo Scientific Product Repair Depot for warranty service will be paid for by the buyer. Our responsibility in respect to warranty claims is limited to performing the required repairs or replacements, and no claim of breach of warranty shall be cause for cancellation or recision of the contract of sales of any unit. With respect to units that qualify for field service repairs, Thermo Fisher Scientific s responsibility is limited to the component parts necessary for the repair and the labor that is required on site to perform the repair. Any travel labor or mileage charges are the financial responsibility of the buyer. The buyer shall be responsible for any evaluation or warranty service call (including labor charges) if no defects are found with the Thermo Scientific product. This warranty does not cover any unit that has been subject to misuse, neglect, or accident. This warranty does not apply to any damage to the unit that is the result of improper installation or maintenance, or to any unit that has been operated or maintained in any way contrary to the operating or maintenance instructions specified in this Instruction and Operation Manual. This warranty does not cover any unit that has been altered or modified so as to change its intended use. In addition, this warranty does not extend to repairs made by the use of parts, accessories, or fluids which are either incompatible with the unit or adversely affect its operation, performance, or durability. Thermo Fisher Scientific reserves the right to change or improve the design of any product without assuming any obligation to modify any unit previously manufactured. THE FOREGOING EXPRESS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Thermo Fisher Scientific's OBLIGATION UNDER THIS WARRANTY IS STRICTLY AND EXCLUSIVELY LIMITED TO THE REPAIR OR REPLACEMENT OF DEFECTIVE COMPONENT PARTS AND Thermo Fisher DOES NOT ASSUME OR AUTHORIZE ANYONE TO ASSUME FOR IT ANY OTHER OBLIGATION. Thermo Fisher ASSUMES NO RESPONSIBILITY FOR INCIDENTAL, CONSEQUENTIAL, OR OTHER DAM- AGES INCLUDING, BUT NOT LIMITED TO LOSS OR DAMAGE TO PROPERTY, LOSS OF PROFITS OR REVENUE, LOSS OF THE UNIT, LOSS OF TIME, OR INCONVENIENCE. This warranty applies to units sold in the United States. Any units sold elsewhere are warranted by the affiliated marketing company of Thermo Fisher Scientific. This warranty and all matters arising pursuant to it shall be governed by the law of the State of New Hampshire, United States. All legal actions brought in relation hereto shall be filed in the appropriate state or federal courts in New Hampshire, unless waived by Thermo Fisher Scientific.