User manual DEAN-10-C

Similar documents
General safety precautions English

Installation instructions

Operating instructions

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

General safety precautions English

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3

High Pressure Washer 130

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

User Manual. Electric Heating Element MEG DRY MOA REG 2 REG 3

2 KW OIL FILLED RADIATOR

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Compact Pressure Washer 100

Surna 25-Ton Chiller Operating & Maintenance Manual

Instructions for installation and use RE/I. Industrial electric heater for swimming pool

Bosch 80% AFUE Gas Furnace BGS80 Model

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

OPERATION MANUAL (Web Site Downloaded only)

V80-H Multistage Pump Instruction Manual

EL195UHE SERIES GAS FURNACE WARNING WARNING

General safety precautions English

General safety precautions English

Operator s Manual. IP-100 Immersion Probe Cooler

Models: RP-10, RP-15, RP-20. User Manual

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

INSTRUCTIONS AND WARRANTY

WHE 2.24 / WHE 2.24 FF

INSTRUCTIONS AND WARRANTY

Clean Air Optima HEPA UV ionizer air purifier CA-508

EL195DFE SERIES GAS FURNACE WARNING

2 KW OIL FILLED RADIATOR

Instructions For Use ENG. LED Magnifier Lamp

Operating and installation instructions

VADA - Rain2Main Automatic Rainwater Controller

Instructions for installation

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

EL195UH SERIES GAS FURNACE WARNING

Operation Manual. Airbrush Airbrush-Spray Booth Compressor Suction Unit Paint E420

Documentation. Parallel Heating Cable. Type: ELP

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2

OPERATION AND MONTAGE MANUAL ROOF FANS

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

A-MIP 200 Installation and Operating Manual

900W OIL FILLED RADIATOR

WARNING FIRE OR EXPLOSION HAZARD.

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

DXAPV3N. Air Purifier. With. Enviro-neutralising Technology DXAPV3N

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

INSTALLATION GUIDE NZ AU GB IE

TTV 4500 / TTV 4500 HP / TTV 7000

AUTOMATIC MODULAR ICE FLAKER

Installation/Instruction Manual

3-way switching valve

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

G61MPV SERIES GAS FURNACE WARNING

A-MIP 100 Installation and Operating Manual

UL U TR LTRASONIC S ONIC SCALE ALER PIEZO MINI

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

SHORT WAVE INFRARED PANEL DRYER

SAFETY AND OPERATING MANUAL. Original Instructions 5.0

infrared paraffin / kerosene / diesel heater

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

ML180UH SERIES GAS FURNACE WARNING WARNING

ST1. Mod. USE AND MAINTENANCE MANUAL

INSTRUCTIONS AND WARRANTY

HG-2000E HEAT GUN WATTS

FastGene Plate Centrifuge. Instruction Manual. Catalog No. NG

NEPTUNE Tubular MI Electric Immersion Heater

Operating instructions

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

IMpORTANT SAFETy INSTRUcTIONS

XC Portable Air Conditioning

1. Information before installation General terms of delivery, storage and transport

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Hot Water Urns v3.0. all models. Helpline. instructions.indd 1 02/06/ :50

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

Design Manual Installation Operation Maintenance

Thermo-Flo Flow Switches FT10 and GT10 Series Owner s Manual

Installation Instructions and Operation & Maintenance Guide

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

EL296UHV SERIES GAS FURNACE WARNING WARNING

WARNING FIRE OR EXPLOSION HAZARD.

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage.

2kW UPRIGHT FAN HEATER INSTRUCTIONS FOR USE

Split Portable Air Conditioner

WHAT TO DO IF YOU SMELL GAS

AUTOMATIC GRANULAR ICE FLAKER

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Snifter ATEX22 VERSION. User Manual. Distributor

Operating Instruction

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

OPTIBAR P 1010/2010 C Supplementary instructions

MD-MINI Dry Bath. Instruction Manual

Installation Manual. Frost Protection Cable. Warmup Ireland Web: Telephone:

Transcription:

GALVATHERM Fluoropolymer Immersion Heaters User manual DEAN-10-C Important Before installing and using this device, please read the entire manual paying attention to the instructions and safety guidelines contained therein.

Content 1. 1.1. 1.2. 1.3. 2. 2.1. 2.2. 2.3. 2.4. 3. 4. 4.1. 4.2. 4.3. 4.4 5. 6. 7. 7.1. 8. 9. 10. 10.1. 10.2. 10.3. 11. Identification Type of material Manufacturer's/distributor's/supplier's address Standards and guidelines General recommendations Warnings Signs used Guarantee and repairs Normal use Safety instructions Description of the product Composition Models and accessories Features of materials used Technical features Marking Installation Electrical connection Connecting the device Commissioning Maintenance and servicing Transport - Storage - Disposal Transport and storage Returning the device Disposing of the immersion heater Guarantee 4 4 4 5 6 6 7 7 8 9 10 10 11 11 12 13 14 15 15 16 18 20 20 20 21 22 GALVATHERM immersion heater 3

Identification 1. Identification 1.1. Type of material Please complete the following information which is engraved on the orange connection pipe. Reference : Serial number : Power : Voltage : _ kw _ V 1~ 3 ~ 1.2. Manufacturer's/distributor's/supplier's address 4 GALVATHERM immersion heater

Identification 1.3. Standards and guidelines GALVATHERM type P and C immersion heaters fulfil the following requirements. Electromagnetic compatibility directive (CEM) 2004/108/EC Low voltage electrical equipment 2006/95/EC EN 60519/1-2 EN 60529, IP64 GALVATHERM immersion heater 5

General recommendations 2. General recommendations Carefully read this user manual and follow all instructions, safety guidelines and standards that apply nationally in terms of accident prevention. This manual is an integral part of the device. It should be handed over to the installation technician and remain available to users for the device's entire lifecycle. 2.1. Warnings Warnings are identified in the following manner : Figure 1. Figure 2. Figure 3. Figure 4. D A N G E R Existence of a hazardous situation. Failure to follow the instructions will lead to death or severe injury W A R N I N G Existence of a hazardous situation. Failure to follow the instructions may lead to death or severe injury. C A U T I O N Presence of a hazardous situation. Failure to follow the instructions may cause light injuries. N O T E Failure to comply with the instructions may cause material damage to the immersion heater. 6 GALVATHERM immersion heater

General recommendations 2.2. Signs used Preliminary conditions that must be fulfilled. Tasks to perform (one step).. 1. The first step in any operation. Subsequent operations are numbered sequentially. 2.3. Guarantee and repairs Should an intervention or repairs be warranted under the guarantee, return the cleaned and neutralised immersion heater to the manufacturer or to your distributor, free of charge, and indicate what the defect is. Please refer to chapter 10 detailing the return procedures and to chapter 11 dealing with the guarantee conditions. GALVATHERM immersion heater 7

General recommendations 2.4. Normal use GALVATHERM immersion heaters of type P.. and C.. are for professional use onlyl. Normal use of the devices : GALVATHERM immersion heaters are used to heat aqueous liquids at atmospheric pressure. The following is also deemed to constitute normal use : Do not use the GALVATHERM immersion heater to heat explosive and/or inflammable liquids, gas or solid materials. GALVATHERM Immersion heaters are not to be used in explosive areas. Follow the instructions provided herein. Do not submit the immersion heater to significant mechanical stress. Do not use the GALVATHERM immersion heater if it shows visible defects. Under no circumstance should you modify the GALVATHERM immersion heater. In case of abnormal use, random modifications, and failure to comply with the manual, or in case of use by non-qualified personnel, the manufacturer rejects all liability for any ensuing damage. Furthermore, such instances will void the guarantee. Explosion and fire hazard D A N G E R Do not use the GALVATHERM immersion heater : - in inflammable or explosive products. - in areas with risks of explosion. - to heat up gases or solids. Ask the manufacturer to provide you with the information you need. 8 GALVATHERM immersion heater

Safety instructions 3. Safety instructions A qualified electrician should connect and commission the immersion heater. The qualified electrician is responsible for the proper connections of the immersion heater Carefully read the entire user manual before commissioning the device and follow the instructions provided. Comply with standards and directives that apply in the country of installation. Follow the CEM directive for the installation. In case of use with hazardous materials (very hot, toxic or presenting a health hazard), follow the safety instructions provided for use with hazardous materials. Ensure permanently safe conditions for the operators, the environment and the liquids used. Ensure that the operators using the immersion heater have been properly trained. Ensure that no one comes in contact with the liquid that is being heated. Verify that the immersion heater and the liquid are mutually compatible. Should you have a doubt, please contact the manufacturer. Protect the immersion heater against overheating and against functioning without liquid. Record modifications and changes in this manual. GALVATHERM immersion heater 9

Description of the product 4. Description of the product 4.1. Composition GALVATHERM Flat Example of type A assembly GALVATHERM Cylindrical Example of type P assembly 1 - Electric connection cable 2 - Connection pipe 3 - Fluoropolymer-coated non heating cable (1). Maximum and minimum immersion depths are indicated with black marks. 4 - Heating segment with fluoropolymer-coated cable (1) 5 - Structure (material and type defined according to the application) 6 - For GALVATHERM cylindrical type P or R : mount made of PVDF or PP 7 - Installation example : PVDF or PP feet for GALVATHERM cylindrical, type P (1) - Depending on Whether FEP or PFA version 10 GALVATHERM immersion heater

Description of the product 4.2. Models and accessories Different types of assemblies are available for both flat and cylindrical GALVA- THERM models. Furthermore, various accessories are available for the immersion heaters, to help during the installation, to improve service and to enhance maintenance ease. Refer to the relevant documents, which may be obtained from the manufacturer or distributor. 4.3. Features of materials used Abbreviation Name Maximum temperature of use FEP Fluorinated ethylene propylene + 80 C PFA Perfluoroalkoxy + 95 C PP Polypropylene + 60 C PVDF Polyvinylidene fluoride + 95 C PVC Polyvinyl chloride + 50 C GALVATHERM immersion heater 11

Description of the product 4.4. Technical features Connection pipe Material Type of protection Exposure temperature PVC Protection against dust and water spray IP64 (EN 60529) - 10 C to + 50 C Electric connection cable Grounding Thermal load Standard length Material 1m PVC (HO5 VV-F) or neoprene insulation (HO7RN-F) depending on power and voltage Continuous copper shielding Standard heating cable: 0.5W/cm2 or 1W/cm 2 (see section 1.1 Identification) Maximum temperature of the liquid For aqueous solutions, up to 80 C (FEP coating) or 95 C (with PFA coating) Nominal power Nominal voltage Type of current Storage temperature See on the connection pipe. Min: 0.5kW max: 15kW See on the connection pipe. Min: 110V max: 460V 1~ or 3 ~ -10 C to +50 C 12 GALVATHERM immersion heater

Marking 5. Marking The connection pipe bears an indication all the important features of the immersion heater : Nominal power Nominal voltage Type of current Reference The reference indicates the model and specifies whether the model is compliant (materials, size) with the process it will be used for. The following illustrations show the underlying code of the reference : GALVATHERM Flat : GALVATHERM Cylindrical : The code tables included in the documentation enable to identify the model. These are available upon request or by downloading them from our Internet site. GALVATHERM immersion heater 13

Installation 6. Installation Please refer to the appended assembly instructions. 14 GALVATHERM immersion heater

Electrical connection 7. Electrical connection Type of voltage Number of phases Connection diagram Colour of connection wires AC current Single phase L N PE brown blue green/yellow AC current Three phase L1 L2 L3 PE brown grey black green/yellow The immersion heater must be electrically connected by a qualified professional electrician. N O T E Risk of damage to the immersion heater Verify that the supply voltage and the immersion heater correspond. 7.1. Connecting the device Verify the following items prior to connecting the device : The connection cable of the immersion heater is in good working order. The connection cable is suited to the installation environment. All necessary electric protections, as per national standards, are installed upstream. The main power supply is disconnected. Connect the immersion heater's cable according to the connection diagram given in the above table. GALVATHERM immersion heater 15

Commissioning 8. Commissioning Check that the heating part is entirely immersed and that the level of the liquid is between the minimal and maximal immersion depths. Ensure that the immersion heater is correctly installed and firmly attached. Check that the heating area is free of any obstruction that would hinder the natural heat radiation (such as deposits, object...). Make sure that nobody is in contact with the liquid. Power up the immersion heater. Control the liquid's temperature change using the appropriate method. A rising temperature indicates that the immersion heater works. Insufficient liquid, the presence of deposits on the heating part or insufficient spacing may lead to poor heat radiation. This may in turn lead to damages to the immersion heater or to parts of the environment that are sensitive to heat. W A R N I N G Fire hazard Ensure that the minimal level of liquid is present. Ensure that the heat can be properly dispersed. 16 GALVATHERM immersion heater

Commissioning Damaged wires or an incorrect connection may electrify the liquid that is used. Should liquid seep into the connection pipe, a ground leakage current may be created. Electric shock hazard W A R N I N G Ensure that the cables and the electric connection are in good working order. Use a fault current protection switch with a threshold of 30mA, EN 61008-1/2-1. GALVATHERM immersion heater 17

Maintenance and servicing 9. Maintenance and servicing GALVATHERM immersion heaters are made of materials that are oxidationresistant and therefore require a minimum of maintenance. To achieve the highest levels of performance, they should be regularly inspected and their proper working order should be frequently verified. During such inspections, follow these procedures : 1. Shut down the immersion heater. 2. Wait at least 15 minutes for the immersion heater to cool down before removing it. C A U T I O N Burn hazard Do not touch the heating part of the immersion heater before it has entirely cooled down. 3. Remove the immersion heater. When handling the immersion heater, ensure that no liquid seeps from it. Injury hazard W A R N I N G Wear all necessary safety and protection equipments. Refer to the safety sheet provided by the equipment's manufacturer. 4. Clean and neutralise the immersion heater. In order to ensure the highest level of safety during maintenance, the immersion heater must be chemically neutralized with adequate means and then abundantly rinsed with water. 18 GALVATHERM immersion heater

Maintenance and servicing 5. Remove deposits or coats Some chemical solutions may cause deposits or a coat to form on the immersion heater. This phenomenon must be prevented as it reduces the transfer of heat and leads to early failure of the immersion heater. The level and time necessary for deposits or coats to form depend on the working conditions. The user must therefore base the frequency of maintenance on observations and experience. No information about the cleaning methods and maintenance cycles can be given because of the specific nature of each application. N O T E Risk of damage to the immersion heater The immersion heater can only be cleaned by chemical means Contact the product's supplier to determine a suitable cleaning method. 6. Check the general state of the immersion heater Ensure that the cable that runs through the heating and non-heating sections of the immersion heater is in good condition and not damaged. Should the cable show any visible signs of damage (such as swelling, holes, etc.) do not power up the immersion heater. Contact the manufacturer and refer to section 10 concerning transport procedures. Check the state of the electric connection cable. It's an integral part of the GALVATHERM immersion heater. In case of a defect, the entire device is to be returned to the distributor or manufacturer according to the procedures given in section 10. GALVATHERM immersion heater 19

Transport - Storage - Disposal 10. Transport - Storage - Disposal Risk of injury C A U T I O N Contact with hazardous substance residues may cause burns. Clean the immersion heater using an appropriate method in case of coating or deposits. In this event, neutralise the hazardous substance deposits. 10.1. Transport and storage During transport, ensure that the packaging provides the immersion heater with proper protection against any damage. The device should be stored as per ambient conditions, as given in the section about technical features. 10.2. Returning the device Follow these instructions when returning the device : Clean and neutralise the immersion heater. Include a description of the use (heated product, concentration, temperature,...). Describe the fault. Indicate the period of use of the device. Provide your address and contact information. The returned device will not be inspected in case of failure to follow these instructions. 20 GALVATHERM immersion heater

Transport - Storage - Disposal 10.3. Disposing of the immersion heater Dispose of the device and its residues as per local environmental regulations. GALVATHERM immersion heater 21

Guarantee 11. Guarantee GALVATHERM immersion heaters are guaranteed against all manufacturing defects for a 12-month period starting on the product's delivery date or for a maximum 15-month period if the device is commissioned at a later date. The guarantee is applicable in case of normal use of the immersion heater and the manufacturer reserves the right to inspect the product. The manufacturer rejects all liability in case of failure to : follow the instructions provided herein, or in case of improper use of the immersion heater, accidental damages, technical modifications of the immersion heater that could damage the immersion heater and affect the user's safety, abnormal wear of the parts (for example the electric cable). Please keep these instructions for the entire lifecycle of the product. 22 GALVATHERM immersion heater

Notes Thermoplongeur GALVATHERM 23

updated 19-12-12 Subject to change, non-contractual pictures