Similar documents
OVER-THE-SIDE HEATERS. immersion heaters

( )

Flange Heaters Type CX

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

Flanged Immersion Heaters

SCREWPLUG HEATERS. immersion heaters

Tubular Industrial Process

Flanged Immersion Heaters

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Tubular Industrial Process

Flanged Immersion Heaters

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Immersion Heaters. Screw Plug Immersion Heater

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Checklist Selecting the Proper Flanged Heater

Screw Plug Immersion Heaters

Tubular Industrial Process

SCREW PLUG IMMERSION HEATERS

( )

(770) wwww.southgateprocess.com

Circulation Heaters Selection Guidelines

Flange Heaters - CX. Application. Corrosion. Watt Density. Passivation. Construction. Flange Heaters CX

STRAIGHT & FORMED TUBULAR HEATERS

( )

Screwplug Heaters. Type CX. Screwplug Heaters Type CX. Operation. Application. Selection. Terminal Block Simplifies Wiring. Warning - Fire Hazard

Strip/Clamp-On Heaters

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

CF1 ProVector Explosion-Proof Heaters

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

MEGAWAT * HIGH DENSITY CARTRIDGE HEATERS

Technical Information

Coil Heaters. Design Features: Typical Applications: Coil Heaters

S1L Series: Metal Bottom

Circulation Heaters Selection Guidelines

CIRCULATION HEATERS. immersion heaters

Circulation Heaters - EX

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

Screw plug immersion heaters

Explosion-proof Immersion Heater Type D-8660

PRODUCT LISTING Tubular Heater Finned Heater

electric immersion heaters

PRODUCT CATALOGUE for the METAL FINISHING INDUSTRY

electric immersion heaters

BAND HEATERS component parts

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

CX1 ProVector Explosion-Proof Heaters

Finned Tubular Heaters

Typical Applications. Braking Resistor Core Drying Dehumidification Forced Air Comfort Heating

Cartridge Heaters. temperatures up to 450 C. heaters in difficult applications. 2. High impact ceramic cap retards HotRods are available in a wide

Flange immersion heaters

Installation, Operation, Maintenance Instructions and RENEWAL PARTS IDENTIFICATION

Tubular Heaters Series

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

Industrial Flanged Immersion Heaters

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Tubular Industrial Process

Cartridge Heaters. Components. Application Guidelines

Light Duty Commercial Electric Water Heater

WATLOW ELECTRIC MANUFACTURING COMPANY

Cartridge Heater Solutions

Tubular Heaters. Table Of Contents

Differences Among Screw Plug Immersion Heaters

10-14 SECTION TUBULAR HEATERS

Agency Certifications, Recognition and Approvals

Radiant Heaters. Radiant Heaters

W A T L O W MULTICELL HEATERS MEET YOUR HIGHEST DEMANDS

MEGABAND * MICA INSULATED BAND HEATERS. Construction overview Clamping mechanisms Termination styles Construction styles Watt density information

Tubular Heaters Introduction. Tubular Heater Introduction. Design Guidelines. View Product

CLE SERIES Fluid heating for emergency eyewash stations

Tubular Heaters Rev 4 ( ) Finned Tubular Heaters. Finned Tubular Heaters. View Product

Installation, Operation Maintenance Instructions and

FE1 Explosion-Proof Electric Air Heaters

MARATHON HEATER. File # E Made in USA

WATLOW ELECTRIC MANUFACTURING COMPANY

Chromalox Calderas eléctricas tipo paquete, de agua caliente, calderas de vapor, son fuente de calor

Strip/Clamp-On Heaters

Unheated straight section Fast response time Choice of lead protection Longer heater life Higher watt densities Made to customer specifications

Safe, abundant supply of hot water on board!

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

Custom built Tubular Heating Elements & Heating Systems for all Fluids. Since RASHMI HEATERS PVT. LTD. An ISO 9001 : 2008 Certified Company

ASME Packaged Electric Water Heater

Installation, Operation and. Maintenance Instructions

W A T L O W. Straight Resistance Wire. Welded End Cap

HotRod CARTRIDGE HEATERS

HL SERIES Fluid heating for commercial applications

Product Catalog. Air and Space Heaters. Section C

Cartridge/Insertion Heaters

Agency Certifications, Recognition and Approvals

W A T L O W. Straight Resistance Wire. Welded End Cap

C1N & C2N SERIES Fluid heating for light industrial applications

Thermostats and Accessories

Air Heating: Portable... 3 Stationary mounting... 6 Gate/door (air curtains)... 8

Industry Best 10 Year Commercial Warranty

Chromalox. Installation, Operation. Circulation Heaters for Oil or Water Heating RENEWAL PARTS IDENTIFICATION PE GENERAL NWH

Shipboard Electric Water Heater

Transcription:

(1-800-492-8826)

OVERVIEW WATTCO over-the-side are made of sidemounted tubular elements. Perfectly designed for freeze protection, for heating viscous solutions, water, oils, solvents, salts, and acids. These heaters are mainly used in solutions requiring easy removal of heaters for cleaning or inspection purposes. EY FEATURES Standard size: 1-inch conduit openings 0.315, 0.375, 0.430, 0.475 diameter element Sheath materials: Stainless steel for stainless steel riser Incoloy for stainless steel riser Steel for steel riser Special sizes, wattages are available upon request Custom-designed to meet your specifications BENEFITS ightweight Portable Easy to install and to remove Easy to maintain Allow for 1 or 3 - phase operation Maximize heat transfer Provide uniform temperature Moisture resistant Oxidation and corrosion resistant Built solidly Designed for safety Durable APPICATIONS Water heating Freeze protection Viscous oils Storage tanks Degreasing tanks Solvents Salts Paraffin Caustic solutions HOW TO INSTA Please follow these installation steps below (see Figures 1 and 2 on page 3) for the heated section of the heater: Heating element must always be fully immersed to prevent heater failure. In determining the minimum liquid level required for proper use of heater, take into account the projected reduction of solution volume due to evaporation or removal of solution while heater is in use. SEECTING WATTCO OVER-THE-SIDE HEATER The following sections will help you select the WATTCO over-the-side immersion heater that will meet the requirements of your application. Please call us at 1-800-4WATTCO (1-800-492-8826) for further information or assistance. APPICATIONS Water Non-corrosive solutions to copper Water rinse tanks Contaminants corrosive to copper Food solutions Oil-based solutions Chemical solutions not corrosive to steel Corrosive contaminants where steel, stainless and copper are unusable SHEATH MATERIA Copper Incoloy / Stainless Steel / Stainless Inconel or Titanium FANGE MATERIA OTSC OTSI OTSO OTST OTST titanium-sheathed heater comes with no stand-off brackets Single phase or three-phase heaters are available NEED ASSISTANCE? Please call us at 1-800-4WATTCO (1-800-492-8826) for further information. Note: ower watt densities usually offer longer service life. 2 (1-800-492-8826)

STAND-OFFS NOT PROVIDED ON TITANIUM HEATER MINIMUM IQUID EVE 75 (3.0) TABE 1 Single Element Type Over-The-Side Immersion (Figure 1) W SHEATH WATTS PER (in. 2 ) (cm 2 ) STANDARD VOTS: 208, 240, 480, 600 (1 PHASE) NET WT BS (G) 3 Copper 19 2.9 OTSC2530 8.8 (4) 5 Copper 32 5.0 OTSC2550 8.8 (4) 7.5 Copper 48 7.4 OTSC2575 8.8 (4) 3 304 S.S. 19 2.9 OTSS2530 8.8 (4) 5 304 S.S. 32 5.0 OTSS2550 8.8 (4) FIG. 1 180 (7.1) 495 (19.5) 7.5 304 S.S. 48 7.4 OTSS2575 8.8 (4) 3 Incoloy 19 2.9 OTSI2530 8.8 (4) 5 Incoloy 32 5.0 OTSI2550 8.8 (4) 7.5 Incoloy 48 7.4 OTSI2575 8.8 (4) 710 (28.0) 245 (9.6) 3 Inconel 19 2.9 OTST2530 8.8 (4) 5 Inconel 32 5.0 OTST2550 8.8 (4) 7.5 Inconel 48 7.4 OTST2575 8.8 (4) 3 Titanium 19 2.9 OTSZ2530 8.8 (4) 5 Titanium 32 5.0 OTSZ2550 8.8 (4) 7.5 Titanium 48 7.4 OTSZ2575 8.8 (4) 35 (1.4) STAND-OFFS NOT PROVIDED ON TITANIUM HEATER MINIMUM IQUID EVE 75 (3.0) 495 (19.5) 245 (9.6) Note: Special dimensions are available upon request. WHEN ORDERING, PEASE SPECIFY: Quantity, catalogue number, voltage, phase, and wattage. TABE 2 Three Element Type Over-The-Side Immersion (Figure 2) W SHEATH WATTS PER (in. 2 ) (cm 2 ) STANDARD VOTS: 208, 240, 480, 600 (1 OR 3 PHASE) NET WT BS (G) 9 Copper 19 2.9 OTSC3090 22.0 (10) 15 Copper 32 5.0 OTSC3150 22.0 (10) 22.5 Copper 48 7.4 OTSC3225 22.0 (10) 9 304 S.S. 19 2.9 OTSS3090 22.0 (10) 15 304 S.S. 32 5.0 OTSS3150 22.0 (10) 22.5 304 S.S. 48 7.4 OTSS3225 22.0 (10) 9 Incoloy 19 2.9 OTSI3090 22.0 (10) 15 Incoloy 32 5.0 OTSI3150 22.0 (10) 22.5 Incoloy 48 7.4 OTSI3225 22.0 (10) 9 Inconel 19 2.9 OTST3090 22.0 (10) 15 Inconel 32 5.0 OTST3150 22.0 (10) 22.5 Inconel 48 7.4 OTST3225 22.0 (10) Note: Special dimensions are available upon request.. WHEN ORDERING, PEASE SPECIFY: Quantity, catalogue number, voltage, phase, and wattage. FIG. 2 230 (9.1) 90 (3.5) 775 (30.5) (1-800-492-8826) 3

APPICATIONS WATTCO bottom mounted heaters come with copper or Incoloy sheaths for use in most liquid heating applications. Refer to the construction chart below or call us at 1-800-492-8826 for further assistance in watt density and sheath selection. CONSTRUCTION SHEATH MATERIA Copper High density Incoloy ow density Incoloy HEATER TCC TCI TCI 3/4 NPT 915 (36.0) B FIG. 3 - TCI EXTRA FEATURES Specially configured wattage or voltage Customized riser height Other sheath materials than those listed are available Built-in thermostat or high limit controls are available 4 sludge legs Passivation for Incoloy and stainless steel sheaths Explosion-proof terminal boxes are available BOX NO THERMOSTAT WITH THERMOSTAT MOISTURE RESISTANT (STANDARD) 3 1/2 4 1/4 6 1/4 6 EXPOSIONPROOF 4 3/4 4 7 5 5/8 TABE 3 Over-The-Side Heaters - Figures 3 & 4 W D I M E N S I O N S B (FIG. 3) B (FIG. 4) (mm) (in.) (mm) (in.) STANDARD VOTS: 208, 240, 480, 600 (1 OR 3 PHASE) SHEATH MATERIA WATTS PER (W/cm 2 ) (W/in. 2 ) FIGURE 3 - TCI 3/4 NPT 915 (36.0) FIGURE 4 - TCP NET WT. BS (G) 3 315 12.4 Copper 8.1 53 TCC303053 TCPC303053 11.0 (5) 6 565 22.2 400 15.7 Copper 9.3 60 TCC306060 TCPC306060 11.0 (5) 9 765 30.1 440 17.3 Copper 8.5 55 TCC309055 TCPC309055 13.2 (6) 12 940 37.0 480 18.9 Copper 8.4 54 TCC312054 TCPC312054 13.2 (6) 15 1115 43.9 520 20.5 Copper 8.4 54 TCC315054 TCPC315054 15.4 (7) 18 1315 51.8 560 22.0 Copper 8.2 53 TCC318053 TCPC318053 15.4 (7) 3 315 12.4 Incoloy 8.1 53 TCI303053 TCPI303053 11.0 (5) 6 565 22.2 400 15.7 Incoloy 9.3 60 TCI306060 TCPI306060 11.0 (5) 9 765 30.1 440 17.3 Incoloy 8.5 55 TCI309055 TCPI309055 13.2 (6) 12 940 37.0 480 18.9 Incoloy 8.4 54 TCI312054 TCPI312054 13.2 (6) 15 1115 43.9 520 20.5 Incoloy 8.4 54 TCI315054 TCPI315054 15.4 (7) 18 1315 51.8 560 22.0 Incoloy 8.2 53 TCI318053 TCPI318053 15.4 (7) 3 565 22.2 400 15.7 Incoloy 4.6 30 TCI303030 TCPI303030 11.0 (5) 6 940 37.0 480 18.9 Incoloy 4.2 27 TCI306027 TCPI306027 13.2 (6) 9 1315 51.8 560 22.0 Incoloy 4.1 26 TCI309026 TCPI309026 15.4 (7) 3 940 37.0 480 18.9 Incoloy 2.1 14 TCI303014 TCPI303014 11.0 (5) 4.5 1115 43.9 520 20.5 Incoloy 2.5 16 TCI304516 TCPI304516 13.2 (6) 6 1315 51.8 560 22.0 Incoloy 2.7 18 TCI306018 TCPI306018 15.4 (7) WHEN ORDERING, PEASE SPECIFY: Quantity, catalogue number, voltage, phase, wattage, type of solution and container sheath. 100 (3.9) D FIG. 4 - TCP 4 (1-800-492-8826)

OVERVIEW WATTCO pipe-insert are perfect for solutions that are difficult to heat as they require low watt density and are mostly stored in large tanks. These heaters are primarily designed for heating viscous fluids. They are mounted in a pipe close to the bottom of a tank. The pipe evenly transfers the heat to stored liquids. FIG. 1 - Standard application of a pipe-insert immersion heater for viscous fluids CONTRO PANE TAN IQUID EVE TEMPERATURE SENSOR HEATER HEATING PROCESS AOW SPACE FOR HEATER EXPANSION PIPE CAP The heating element transfers the heat to the inner wall of the pipe by convection and radiation processes. Note: Do not fill the pipe with a heat transfer fluid. EY FEATURES Made of superior alloy-sheathed elements. 3 150 lb steel flange or 2 NPT screwplug. Moisture-resistant terminal box. Single 1 NPT conduit fitting for units without a thermocouple. Extra ½ NPT conduit fitting for units with a built-in thermocouple. Thermocouples detect rises in temperature, then automatically shut the system off. If the liquid level is beneath the uppermost part of the heater, the inside temperature of the heater s pipe will increase. For detecting low liquid levels, use -type thermocouple heaters with one thermocouple per tank. Upon request, WATTCO can supply a control panel or ship the control components individually. APPICATIONS Asphalt Molasses Tar Paint Glue Viscous fluids Corrosive liquids If devices are required in corrosive liquids, a corrosionresistant pipe is required. Pipes are normally supplied and installed by the tank manufacturer, unless specifically requested. Removing the heater is done easily without draining the liquid. (1-800-492-8826) SEECTING AND SIZING YOUR WATTCO PIPE-INSERT IMMERSION HEATER Determine the kilowatts required to keep the tank at the required temperature. Select the number of heaters required with an insert length that is long enough for good heat transfer. Use single element or double element heaters in groups of three when installing a three-phase balanced system. Select the single element heater for heating a viscous liquid from a cold start, as the lower watt density you will get on the pipe surface will prevent coking (refer to Table 1). TABE 1 Watt Density On Pipe Surface vs. Heater Type PIPE SIZE 1 EEMENT 2 EEMENT 3 EEMENT 2" 5.5 7.4 6.8 2 1/2" 4.6 6.2 5.7 3" 3.8 5.1 4.7 4" 3.0 4.0 3.7 EXTRA FEATURES Bundle control systems Custom voltages Custom wattages Explosion resistant terminal housings Built-in thermostats/controls Custom lengths Custom flange or screwplug sizes Additional conduit fittings 5