Tubular Industrial Process

Similar documents
Tubular Industrial Process

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

Tubular Industrial Process

Checklist Selecting the Proper Flanged Heater

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Typical Applications. Braking Resistor Core Drying Dehumidification Forced Air Comfort Heating

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Immersion Heaters. Screw Plug Immersion Heater

Flanged Immersion Heaters

Flanged Immersion Heaters

Flanged Immersion Heaters

Circulation Heaters Selection Guidelines

Unheated straight section Fast response time Choice of lead protection Longer heater life Higher watt densities Made to customer specifications

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018

SCREW PLUG IMMERSION HEATERS

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

Tubular Industrial Process

Screw Plug Immersion Heaters

Tubular Industrial Process

( )

Circulation Heaters Selection Guidelines

OVER-THE-SIDE HEATERS. immersion heaters

Chromalox. Installation, Operation. Circulation Heaters for Oil or Water Heating RENEWAL PARTS IDENTIFICATION PE GENERAL NWH

Radiant Process Heaters

COIL AND CABLE HEATERS. Mightyband Cable Heaters Tempco-Pak Cable Heaters

S1L Series: Metal Bottom

temperature Controllers

Flange Heaters - CX. Application. Corrosion. Watt Density. Passivation. Construction. Flange Heaters CX

Tempco s process controllers provide integrated solutions to manage your thermal loop system.

Coil & Cable Heaters. Table Of Contents

MEGAWAT * HIGH DENSITY CARTRIDGE HEATERS

ULTRA-SAFE Explosion-proof Duct Heaters

Installation, Operation and. Maintenance Instructions

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

Pictorial Index... A-4 Mi-Plus (Mineral Insulated Band) Duraband (Mica Band) Injection Molding Replacement Band Heaters...

Helically wound resistance wire coil made

"ESDDR" Series Electric Humidifier

Installation, Operation, Maintenance Instructions and RENEWAL PARTS IDENTIFICATION

Differences Among Screw Plug Immersion Heaters

ULTRA-SAFE Explosion-proof Duct Heaters

10-14 SECTION TUBULAR HEATERS

How 1 is your resistance. wire sized? What grade of magnesium oxide is being used? How 3 is your cold pin attached to your resistance wire?

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

Tubular Heaters Introduction. Tubular Heater Introduction. Design Guidelines. View Product

Cartridge Heaters. Components. Application Guidelines

Flange Heaters Type CX

( )

(770) wwww.southgateprocess.com

SCREWPLUG HEATERS. immersion heaters

Tubular Heaters Rev 4 ( ) Finned Tubular Heaters. Finned Tubular Heaters. View Product

Ultra-Safe EXP Unit Heater

Tubular Heaters. Table Of Contents

Industrial Flanged Immersion Heaters

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Cartridge Heaters. Table Of Contents

Machining: Moderate to Extensive. Pattern Shop

Strip/Clamp-On Heaters

W A T L O W. Straight Resistance Wire. Welded End Cap

Thermal Devices, Inc. Mount Airy, Maryland USA C D E F. Typical Maxiband Clamping

Mineral Insulated Band Heater

Thermal Devices Inc. Mount Airy, Maryland USA Process Air and Radiant. ADH Typical Installation.

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER. ELECTRIC HEATER COMPANY BASE MODEL SH and H

Thermo-Platens. Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment

Machining: Moderate to Extensive. Pattern Shop

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

( )

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

"ER" Series Electric Humidifier

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

STRAIGHT & FORMED TUBULAR HEATERS

WATLOW ELECTRIC MANUFACTURING COMPANY

The Leaders in Heat Transfer. CRES MF Compact In-Line Electric Heater

Thermostats and Accessories

FX5 Series Explosion-Proof Electric Air Heaters

Ceramic Fiber Heaters

W A T L O W. Straight Resistance Wire. Welded End Cap

Custom Duct Heaters. Special Applications

electric immersion heaters

Mobile Heated Cabinet

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

ASME Packaged Electric Water Heater

Brasch Hazardous Location Unit Heaters

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

MARATHON HEATER. File # E Made in USA

CX1 ProVector Explosion-Proof Heaters

Chromalox. Installation, Operation. Screw Plug Heating Solution Control Panel Assembly for Screw Plug Heaters RENEWAL PARTS IDENTIFICATION

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

electric immersion heaters

High Performance Heater with More Efficient Heat

Transcription:

Application Tempco Over-the-Side Immersion Heaters are specifically designed for heating fluids in tanks. Depending on the tank shape, size, accessibility and working area inside the tank, choose a round or L shaped heater. Standard sheath materials are Incoloy 800 and steel with all wetted parts made with compatible alloys. Construction Tubular heating elements are welded into a liquid-tight junction box. Power leads for the elements travel up through the riser pipe and are connected to a terminal block in a NEMA 4 Housing. Unless otherwise specified, heaters are wired for three-phase from the factory but can easily be converted to single-phase. A thermowell for a 3/8" diameter bulb is standard to accommodate an optional thermostat. A thermostat can be field installed to mounting lugs located in the electrical enclosure. 4" (10 mm) sludge legs keep the elements off the bottom of the tank and above any deposits that may accumulate there. Optional Features 304 or 316 Stainless Steel construction for all wetted parts Passivation of all wetted parts. Electropolished or bright annealed surface treatments for Stainless Steel or Incoloy designs (heating elements only) NEMA 1 or NEMA 4/7 (explosion resistant) terminal housings Flange, fixed or adjustable bracket on riser for mounting Mounting flange for terminal housing External power wiring options include flexible cord/plug, armored cable, wire braided or plain lead wire Double- or Single- pole thermostat (see page 11-6 for available ranges) Process or Hi-limit thermocouple in thermowell in place of the thermostat Hi-limit MI thermocouple on sheath Special riser and/or sludge leg heights Up to 1 elements per heater assembly Right-angle riser design B ±1/4 Typical Heating Applications: Lightweight Oils Degreasing Solutions Mineral Oil Steel Sheath Heating Elements NEMA 4 Terminal Housing Over-the-Side Immersion Heaters Lightweight and Portable Easy Installation and Removal NEMA 4 Electrical Enclosure Single- or Three-Phase Wiring A ±1/ Watt Density of 3 watts/in (3.6 watts/cm ) B ±1/4 4" A ±1/ 4" A B Part Number Approximate Element Net Weight Shape in mm in mm KW 40V-3Ph 480V-3Ph lbs kg 39 5 16 999 13 1 343 3 TAT0001 TAT000 17 8 Round 51 5 16 1303 18 1 470 6 TAT0003 TAT0004 0 9 51 5 16 1303 3 1 597 9 TAT0005 TAT0006 10 39 5 16 999 5 8 575 3 TAT10001 TAT1000 7 Straight 51 5 16 1303 37 5 8 956 6 TAT10003 TAT10004 18 8 51 5 16 1303 5 5 8 1337 9 TAT10005 TAT10006 0 9 11-78 View Product Inventory @ www.tempco.com

A B Part Number Approximate Element Net Weight Shape in mm in mm KW 40V-3Ph 480V-3Ph lbs kg 39 5 16 999 13 1 343 3 TAT0007 TAT0008 17 8 Round 51 5 16 1303 18 1 470 6 TAT0009 TAT0010 0 9 51 5 16 1303 3 1 597 9 TAT0011 TAT001 10 39 5 16 999 5 8 575 3 TAT10007 TAT10008 7 Straight 51 5 16 1303 37 5 8 956 6 TAT10009 TAT10010 18 8 51 5 16 1303 5 5 8 1337 9 TAT10011 TAT1001 0 9 Typical Heating Applications: Citric and Phosphoric Acid Solutions Water-Based Chemical Solutions Incoloy Sheath Heating Elements NEMA 4 Terminal Housing Over-the-Side Immersion Heaters Watt Density of 3 watts/in (3.6 watts/cm ) Typical Heating Applications: Process Water Mild Caustic Solutions (% max.) Clean Water Incoloy Sheath Heating Elements NEMA 4 Terminal Housing Watt Density of 4 watts/in (7.4 watts/cm ) A B Part Number Approximate Element Net Weight Shape in mm in mm KW 40V-3Ph 480V-3Ph lbs kg 39 5 16 999 10 3 4 73 3 TAT0013 TAT0014 16 7 39 5 16 999 13 1 343 6 TAT00 TAT0016 17 8 Round 39 5 16 51 5 16 999 1303 16 18 1 406 470 9 1 TAT0017 TAT0019 TAT0018 TAT000 18 0 8 9 51 5 16 1303 1 1 4 540 TAT001 TAT00 1 10 51 5 16 1303 3 1 597 18 TAT003 TAT004 10 39 5 16 999 14 5 8 371 3 TAT10013 TAT10014 14 6 39 5 16 999 5 8 575 6 TAT100 TAT10016 7 Straight 39 5 16 51 5 16 999 1303 30 1 8 37 5 8 765 956 9 1 TAT10017 TAT10019 TAT10018 TAT1000 16 18 7 8 51 5 16 1303 45 1 8 1146 TAT1001 TAT100 19 9 51 5 16 1303 5 5 8 1337 18 TAT1003 TAT1004 0 9 Catalog Heaters Over-the-Side Immersion Heater Part Numbers in red are in stock for immediate delivery. Non-Stock Part Numbers are standard designs that are stocked as sub-assemblies for -3 week delivery. Custom Engineered/Manufactured Heaters An electric heater can be very application specific, for sizes and ratings not listed, TEMPCO will design and manufacture an Over-the-Side Immersion Heater to meet your requirements. Standard lead time is Stock to 3 weeks. Please Specify the following: Application Element Watt Density Wattage, Voltage and Phase A and B dimensions Element Sheath Material Optional Features Number of Elements Quantity (800) 33-6859 Email: sales@tempco.com 11-79

General Purpose Tank or Reservoir Water Immersion Heater A ±1/" Immersion section of heater made of 316 Stainless Steel Cold riser extends to the top of container where control housing is located Cord set with 3-wire grounding plug is included for easy installation and wiring. Adjustable vapor-proof thermostat control with temperature range of 55 F to 1 F (±3 ) Hi-limit cut switch set to F (±4 ) Stainless Steel mounting bracket also supplied for easy mounting Pilot light and on-off switch provided Hi-Limit: If the thermostat should fail and its contacts stick in a closed position, the heating element will continue to heat to about F. At this temperature the Hi-Limit will open and turn the heating element off. After repairing or replacing the thermostat the Hi-Limit can be manually reset. B ±1/4" 7" Heated Hazard of electric shock. Installation must be grounded to earth and heater connected to line input through properly sized GFCI circuit breaker. Disconnect power to heater before servicing. There should be no body contact with the water while the heater is in the water. Under NO circumstances should this heater be turned on unless the system is full of water. Watt Density A Dim. B Dim. Part Number Sheath w/in Watts Volts in in 4 ft. cord 6 ft. cord 316 Stainless Steel 51 6000 40 39-3/4 17-1/ TAT4001 TAT40017 (Bright Annealed) 13 1440 10 39-3/4 17-1/ TAT40016 TAT40013 Wiring Diagram Internal Electrical Connections 11-80 Rev 1 (4-14) View Product Inventory @ www.tempco.com

Vertical Loop Low Profile Immersion Heaters 6" A ±3/4 Tubular Industrial Process Used on open-top tanks for heating water, water-based solutions, citrus juices, plating tanks, oil tempering, salt baths and other mild corrosive solutions. NEMA 4 (moisture resistant) housing with integral grounding terminal is standard. Other NEMA ratings available. Low-profile design with adjustable SS mounting bracket. Optional Passivated, Electropolished, or Bright Annealed surface treatments available for Stainless Steel or Incoloy sheath designs. External power wiring options including flexible cord/plug, armor cable, braided or plain lead wire. Optional Hi-limit MI thermocouple on heater sheath. Standard (Non-Stock) and Stock Sizes B ±1/4" REF Heated Watt Density Dimensions (in) Part Sheath w/in Watts Volts A B REF Number Copper 5 40 5000 7500 40 40 6 6 TAT50011 TAT5001 Stainless 5 5000 40 6 3 4 TAT50013 Steel 40 7500 40 6 3 4 TAT50014 Steel 5 40 5000 7500 40 40 6 6 TAT500 TAT50016 Standard lead time is Stock to 3 weeks. B ±1/4" 4"±1/" Heated A ±1/" Sanitizing Sink Immersion Heaters Used for sterilization of water tanks in restaurants, taverns and laboratories Double Pole 60-50 F thermostat with over-temperature cutout. Optional pilot lamp to indicate heater on/off status available. Standard lead time is Stock to 3 weeks. Standard 6 ft. (optional 4 ft.) cord set with grounding plug (NEMA 5-P for 10V and 6-30P for 40V) Adjustable Stainless Steel mounting bracket Consult Tempco for custom designs Standard (Non-Stock) and Stock Sizes Watt Density A Dim. B Dim. Part Sheath w/in Watts Volts in in Number 65 6000 40 6 17 TAT40001 316 Stainless Steel 56 4000 40 6 13 TAT4000 (Electropolished) 16 00 10 6 17 TAT40003 14 1000 10 6 13 TAT40004 65 6000 40 6 17 TAT40005 316 Stainless Steel 56 4000 40 6 13 TAT40006 (Bright Annealed) 16 00 10 6 17 TAT40007 14 1000 10 6 13 TAT40008 Ordering Information Catalog Heaters Order by Part Number for catalog heaters listed. Custom Engineered/Manufactured Heaters Consult Tempco. (800) 33-6859 Email: sales@tempco.com 11-81

Mounting Surface Shown for Reference Only Deep Tank/Sump Immersion Heater Application These fluid immersion heaters are designed for top mounting in large or deep enclosed tanks having a manhole access or opening suitable to insert & attach the heater. They are usable for either outdoor or indoor applications, within exposed or in-ground tanks and sewerage sumps. They are designed for permanent mounting and can be sealed weathertight with supplied gaskets and adjustable riser fittings. NEMA 4 terminal housing is easily removable & resealed to facilitate installation. Units are available with element watt densities from 6 wsi for heavy oils, to 60 wsi for clean water immersion applications. Element bundle diameters ranging from minimum of 10" OD to a maximum of 30" OD are available. Construction The tubular elements are welded into a submersible liquid-tight stainless steel junction box. Element power leads are routed up through adjustable riser pipe and connected to a terminal block inside the upper NEMA 4 terminal housing. Unless specified otherwise, heaters are factory wired for three phase and are easily converted to single phase. All wetted parts are 300 series stainless steel. Standard unit includes 60-50 F doublepole thermostat mounted in upper housing that has a 3/8" dia. bulb & capillary installed in watertight thermowell with adjustable compression fitting..475 diameter Incoloy elements and stainless steel wetted parts standard Designed for permanent installation in outdoor/indoor applications ft to 1 ft vertical riser height (for thermostat designs) Weathertight mounting hardware supplied Riser adjustable to facilitate mounting variations NEMA 4 Electrical Enclosure with 3/4 conduit fitting 1-1/" Sludge legs Double-pole 60-50 F pilot duty thermostat Watertight thermowell sized for 3/8" max. dia. sensing bulb 10V, 08V, 77V, & 575V versions available (consult Tempco) Optional Features 316 SS, Steel, or Copper element designs Passivation, electropolished, or bright annealed surface treatments for stainless steel or Incoloy designs (elements only) Custom or ASI pressure rated flange on riser for mounting NEMA 1 or NEMA 4/7 (explosion resistant) terminal housings Alternate single- or double-pole thermostat (see page 11-6 through 11-9 for ranges) Internally mounted definite purpose Magnetic Contactor, single circuit units only (see page 13-96 for volt/amp ratings and coil voltages available) RTD or Process MI thermocouple in thermowell in place of thermostat Hi-limit thermocouple on element sheath Special riser or sludge leg heights Right-angle riser design for offset terminal housing Up to 4 elements per heater assembly 1/3 DIN temperature controller, internal or panel mounted on terminal housing and used with T/C or RTD probe & contactor for heater control Integrated float switch for liquid level control 11-8 View Product Inventory @ www.tempco.com

Deep Tank/Sump Immersion Heaters Tubular Industrial Process Standard (Non-Stock) Deep Tank & Sump Immersion Heaters 1 watts/sq. in. Number A Dim. B Dim. E Dim. Part Number KW of Elements in in in 40V-1Ph 40V-3Ph 480V-1Ph 480V-3Ph 4 3 7-1/4 7-1/ TAT60001 TAT6000 TAT60003 TAT60004 8 6 7-1/4 10-1/ TAT60005 TAT60006 TAT60007 TAT60008 1 9 7-1/4 13-1/ TAT60009 TAT60010 TAT60011 TAT6001 1 7-1/4 16-1/ TAT60013 TAT60014 TAT600 0 7-1/4 19-1/ TAT60016 TAT60017 TAT60018 30 4 7-1/4 8-1/ TAT60019 TAT6000 Catalog Heaters Order-by Part Numbers. Custom Engineered/Manufactured Heaters An electric heater can be very application specific; for sizes and ratings not listed, TEMPCO will design and manufacture an Over-the-Side Immersion Heater to meet your requirements. Standard lead time is 4 weeks. Please Specify the following: Application Element Watt Density Wattage, Voltage and Phase A and B dimensions Element Sheath Material Optional Features Number of Elements Quantity (800) 33-6859 Email: sales@tempco.com 11-83