Starting current with soft starter Fuse protection. Heat source connection

Similar documents
Starting current with soft starter Fuse protection

Starting current with soft starter Fuse protection

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

Dimplex High efficiency air-to-water heat pump for indoor installation. (Low temperature) Order reference

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels

PRODUCT DATA SHEETS HEAT PUMPS

Product Range Overview 2010

Product Range. Overview 2015.

WARMTEPOMPEN DIMPLEX. POMPES À CHALEUR DIMPLEX.

WZS 82(H)(K)3M 20 I B0W I I I (263) (288) 7.0

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

For a future without oil and gas.

Technical data LA 60TUR+

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

BWL air heat pumps BWS brine heat pumps

A w rld of new product innovation new product launches

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Advance Split

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

Technical data LA 60TU

Technical data LA 9S-TU

Technical data LA 28TBS

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

LZT High efficiency air to water heat pumps with E.V.I. compressors

Planning guide. (2010/09) en

LZA High efficiency air to water heat pumps with HP compressor

WZH Ground source heat pumps

WPM 2006 plus WPM 2006 R WPM 2007 plus WPM 2007 R

VIESMANN. VITOCAL Air/water heat pumps. Technical guide. VITOCAL 300-A Type AWC-I and AW-O. VITOCAL 350-A Type AWH-I and AWH-O

Oilon Ground Source Heat Pumps

Air / Water Heat Pump - Compact Design Modulating 8 18 kw

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

HIGH-POWER HEAT PUMPS. Up to 300 kw

MODEL LA 6 MI LA 9 MI LA 12 MI LA 16 MI. Heat output (kw)/cop at A-15/W35 5.9/ / / /2.33

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

ECOFOREST GEOTERMIA. ecogeo. Ground/Air Source Heat Pumps.

VIESMANN VITOCAL 300-G Brine/water and water/water heat pump Single and two-stage, from 21 kw

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Outline principle. Application Houses with water-borne heating systems. Alternative Select the desired configuration by highlighting the boxes below.

Outdoor Reset Control Theory FULL versus PARTIAL reset

Do you want a versatile solution

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Heating Controller SDC Remote Heating Controller DHC

Type summary Albatros 2

Heating Controller SDC Remote Heating Controller DHC

WHA WHA. Ground source heat pumps OTHER VERSIONS ACCESSORIES

TERMO Combi Cylinder TECHNICAL INFORMATION

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

HT V2 HT Split

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

Efficient heating that won t cost the earth

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

REMKO HYBRID HEAT PUMPS

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER

Product Line Introduction. Karl Zhang Technical support engineer

CRIMSON & CRIMSON MAX

Technical specifications

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

Heating and D.h.w. Controller RVL482 Basic Documentation

High temperature air-to-water heat pumps

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

LZT High efficiency air to water heat pumps with E.V.I. compressors

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

NABILATON PRO. The Nabilaton Pro heat pumps consist of MDV brand outdoor units and suitable hydraulic modules from Nabilaton.

HEAT PUMPS EN - flyer 10/p/2017 Made in Poland

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

Ecoforest. Innovating from the beginning. Foundation of the company. Creation, innovation stars 1968

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

Technical description. Atec.

Press. Heat pumps from Viessmann: efficient heat generation with renewable energy and electricity

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M.

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax

A2/W35: 8.6kW, Power consumption: 2.39kW, COP 3,6. A2/W35: 10.1kW, Power consumption: 2,8kW, COP 3,6

ECOplus Solar Cylinder

Heat Pumps. Compact. Device Information. Operating manual supplement. LWC Series

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Saving energy comes naturally to us.

UK arotherm Schematics and installation guide

NIBE F1355. A +++ The system's efficiency class for heating. Speed-controlled ground source heat pump for large buildings. Ground source heat pump

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

and sanitary hot water Catalogue 2009

HIWARM COMPACT kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

KEMPER ThermoSystem. For further information on KTS use the QR code!

Natural geothermal energy

Solar heating systems

Technical data. Danfoss DHP-L

Ground source heat pump range. Why Vaillant? because we can unearth the energy.

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Transcription:

Data sheet SI 17TE Brine-to-water heat pump max. flow temperature: 58 C Casing colour: white Brown-red design screen (RAL 3011) Heat pump for indoor installation with integrated regulation WPM 2007 plus. The control panel is integrated into a brown-red design screen and can also be used as wired remote control using the wall mounting set (special accessories MS PGD). Variable connection options for brine and heating connections on the rear wall of the casing. Sound-optimised through insulated metal casing and double vibration-isolated compressor. Economiser for high coefficients of performance. Universal design with optional DHW preparation and the option of flexible expansion for: - Bivalent or bivalent-renewable operating mode - Distribution systems with unmixed and mixed heating circuits Integrated soft starter and load contactor for brine circulating pump, integrated flow and return flow sensors; external sensor (standard NTC-2) and dirt filter for brine circuit included in the scope of supply. Technical data Dimplex Brine-to-water heat pump (Low temperature) Order reference SI 17TE Casing colour white max. flow temperature 58 C Lower operating limit heat source (heating operation) / Upper operating limit heat source (heating operation) -5 to 25 C Heat output 1 compressor at B0/W35 / COP B0/W35* 16,9 kw / 4,4 Heat output with 1 compressor / COP B0/W45 16,2 kw / 3,4 minal consumption according to EN 14511 at B0/W35 3,86 kw Sound power level device 58 db (A) Refrigerant / Amount of refrigerant R407C / 2,3 kg Maximum heating water flow rate / Pressure drop 2,9 m³/h / 15000 Pa Heat source flow min. 4 m³/h Dimensions (W x H x D)** 650 x 805 x 462 mm Weight 133 kg Connection voltage 3/N/PE ~400 V, 50 Hz Starting current with soft starter 27 A Fuse protection C 16 A Connection heating 1 ¼ inch Heat source connection 1 ¼ inch *Heat output and COP acc. to EN 14511 at B0/W35 (B0 = brine inlet temp. 0 C, W35 = heating water outlet temp. +35 C) **Please note that additional space is required for pipe connections, operation and maintenance. Page 1/6

System accessories SI 17TE Description Heat pumps Order ref. Article number Brine-to-water heat pump SI 17TE 352900 1 Elasticated sound insulation underlay strips SYL 250 352260 DN 32 double-sphere rubber expansion joint KOMP 32 362060 DN 32 dirt trap SMF 32 362140 Heat source accessories Sample Brine circuit manifold connection package AP SVT 348900 1 Brine circuit manifold (2-fold) with clamping ring fittings SVT 200KV 363860 Brine circuit manifold (3-fold) with clamping ring fittings SVT 300KV 363870 1 Brine circuit manifold (4-fold) with clamping ring fittings SVT 400KV 363880 1 Brine circuit antifreeze (20l) AFN 825 328610 6 Hydraulic accessories Floor-mounted buffer tank (200l) PSW 200 339830 1 CTHK 630 immersion heater, 4.5 kw, ~230 V CTHK 630 363610 immersion heater, 2.0 kw, ~230 V CTHK 631 336180 CTHK 632 immersion heater, 2.9 kw CTHK 632 335910 CTHK 633 immersion heater, 4.5 kw CTHK 633 322140 CTHK 634 immersion heater, 6.0 kw CTHK 634 322150 Universal buffer tank (500 l)* PSW 500 339210 Dual differential pressureless manifold DDV 25 358390 1 Circulating pump for heating water UP 60 340300 1 Circulating pump for heating water UP 80 340310 Hot water module / unmixed heating circuit module WWM 25 346600 1 Electronically regulated circulating pump for heating water UPE 60 358870 1 Electronically regulated wet running pump (0-10 V) with coupling relay UPE 70-25 362790 Manifold bar VTB 25 339870 Mixed heating circuit module with temperature sensor MMH 25 348640 Mixer module for bivalent systems MMB 25 348880 Ready-for-use DN 32 stainless steel Wellflex pipe VSE 32-50 362520 Ready-for-use DN 32 stainless steel Wellflex pipe VSE 32-100 362530 Ready-for-use DN 32 stainless steel Wellflex pipe VSE 32-150 362540 Ready-for-use DN 32 stainless steel Wellflex pipe VSE 32-200 362550 Ready-for-use DN 32 stainless steel Wellflex pipe VSE 32-300 362560 Heating accessories Fan convector for heating 800 W SRX 080M 359080 Fan convector for heating 1200 W SRX 120M 359090 Fan convector for heating 1400 W SRX 140M 359100 Fan convector for heating 1800 W SRX 180M 359110 Immersion heater pipe assembly* HDLR 450 337450 DHW preparation accessories Hot water cylinder (400l) with temperature sensor WWSP 880 337880 1 Flange heater for domestic hot water FLH 60 338060 Flange heater for domestic hot water FLHU 70 338070 1 FLH 25M flange heater FLH 25M 349430 Safety valve combination SVK 852 326660 Design hot water cylinder with sheet metal coverings and temperature sensor* WWSP 442E 353370 Hot water cylinder (500 l) with temperature sensor* WWSP 900 339220 500l solar cylinder for heat pump WWSP 540 SOL 361090 Combo tank for heating and domestic hot water preparation with central flow* PWD 750 349100 Combo tank for heating and domestic hot water preparation with central flow* PWD 900 362860 Pump unit DN 25 for direct connection of the hot water cylinder WPG 25 356030 1 Circulating pump for heating water UP 80 340310 1 Control accessories Extension for an Ethernet network connection NWPM 356960 Extension for a KNX/EIB bus connection EWPM 356970 Extension for a Modbus connection LWPM 410 339410 item Item Price Page 2/6

System accessories SI 17TE Description Order ref. Article number Interface card for WPM for connection of Smart RTC and WPM Econ PK/PKS 14/25 Econ RWPM 363370 Swimming pool / remote fault indicator relay module RBG WPM 339700 Wall mounting set MS PGD MS PGD 353810 Remote control for WPM 2006/2007/EconPlus/R* AP PGD 356570 External temperature sensor with casing FG 3115 336620 Temperature sensor NTC-10 with metal sleeve NTC-10M 363600 Thermostat for heating and domestic hot water KRRV 003 322070 Accessories for passive cooling Three-way distribution valve DWU 25 347760 Three-way distribution valve DWU 40 347770 Two-way shutoff valve ZWU 25 348940 Two-way shutoff valve ZWU 32 348950 Control accessories (cooling) Room climate control system for temperature and humidity measurement RKS WPM 342220 Room temperature controller heating/cooling* RTK 601U 355610 Room temperature controller heating/cooling RTK 602U 355620 Dew point monitor* TPW WPM 350970 * Other specific accessories available / required Sample tes: The heat source accessories are designed for ground heat collectors according to the project planning documentation. Important information: The combination of the components and the quantities indicated represent a non-binding sample system, which needs to be tested and individually adapted as required. Pump dimensioning must be reviewed according to the pressure loss of the system and the minimum heating water flow rate of the heat pump. item Item Price Page 3/6

Brine-to-water heat pump, Integration Diagram, Heat pump only te: The given hydraulic integration schematic is a schematic representation of the key components and serves as an aid for planning your customized system. The current status is available at all times under www.dimplex.de/nc/en/professional/onli ne-planner/hydraulic-integrations.html. It does not contain all the required safety devices, the components needed to maintain constant pressure, or any other additional valves which may be required for maintenance and service work as stipulated by EN 12828. The heat pump manager settings and any external regulation system which may be connected must be adapted to the present integration diagram. Software updates may be required! Page 4/6 Integration Diagram: 20131020

Brine-to-water heat pump, Integration Diagram, Heat pump only System description: Every brine circuit should be provided with a shutoff valve for ventilation purposes. Brine circuits must all be of the same length in order to ensure that each has an equal flow and abstraction capacity. The filling and breather mechanisms should be installed at the highest point. A buffer tank connected in series is recommended for heat pump heating systems, to ensure the minimum heat pump runtime of 6 minutes for all operating statuses. In monovalent systems, the output of the heat pump covers the heat consumption of the building throughout the whole year - 100% - by itself. High heat output during shut-off times and domestic hot water preparation is supplied by the heat pump. rmally, only brine-to-water and water-to-water heat pumps are operated in monovalent mode. The heat exchanger in the hot water cylinder must transfer the maximum heat output at the maximum heat source temperature. In systems with high hot water consumption (multiple dwellings, industrial applications) the cylinder must be set to the maximum peak demand while taking the shut-off times into account. The maximum heat output and the maximum heating water flow must be adhered to! The contactor for the flange heater (E9) in the hot water cylinder should be dimensioned according to the output and must be supplied by the customer. It is controlled (230 V AC) by the heat pump manager via terminals X1/N and J16/NO10. The maximum heat output of the heat pump and the water flow are to be observed. The dual differential pressureless manifold ensures that the required minimum water flow rate is maintained, independent of both the number of open heating circuits and of how the system is used. Hydraulic isolation is carried out using two connections between flow and return; each connection is fitted with a check valve. The characteristic curve of the pump in the consumer circuit must be set in such a way that a maximum spread of 10 Kelvin is not exceeded, in order to prevent unnecessary surging of the heat pump. Electronically regulated pumps must be operated at a constant pressure. Presettings: Pre-configuration Operating mode Heating circuit 1 Heating circuit 2 Passive cooling function DHW preparation DHW preparation request by Domestic hot water preparation flange heater Swimming pool water preparation Low pressure brine - measurement present Low-pressure brine Setting Monovalent Yes Yes Sensor Yes Display Page 5/6 Integration Diagram: 20131020

Brine-to-water heat pump, Integration Diagram, Heat pump only Legend: 1. Heat Pump 1.1 Air-to-water heat pump 1.2 Brine-to-water heat pump 1.3 Water-to-water heat pump 1.4 Reversible air-to-water heat pump 1.5 Reversible brine-to-water heat pump 1.6 Reversible water-to-water heat pump 2. Heat pump manager 3. Parallel buffer tank 3.1 Buffer tank 4. Hot water cylinder 5. Swimming pool heat exchanger 6. Passive cooling station with cooling controller N6 7. Heating and silent or dynamic cooling 8. Fan convector with 4-wire connection 9. Cooling circuit only 10. Heating circuit only 13. Heat source 15. Hydraulic tower 16. Scalding protection 17. Hydro tower HWK 332 Domestic hot water distribution system: DDV 32 EB KPV KPV 25 MMB 25 MMH 25 VTB 25 WWM 25 Dual differential pressureless manifold (up to 2.5 m³/h)* Extension module for compact manifold (up to 2.0 m³/h)* Compact manifold with overflow valve (up to 1.3 m³/h)* In combination with EB KPV (up to 2.0 m³/h)* Mixer module, bivalent (up to 2.0 m³/h)* Mixer module for heating circuit Manifold bar (up to 2.5 m³/h)* Hot water module / unmixed heating circuit (up to 2.5 m³/h)* * Recommended max. heating waterflow Solarthermics: SST 25 Solar station for hot water SOLK 1204 Collector field SOLPU 1 Solar station SOLCU 1 Solar controller SOLCU 2 Solar controller T1 Temperature sensor (collector sensor) T2 Temperature sensor (cylinder 1) T3 Temperature sensor (cylinder 2 /optional display function) B3 Hot water thermostat B4 Swimming pool thermostat E9 Flange heater, hot water E10 2nd heat generator (HG2) E10.1 Immersion heater E10.2 Oil/gas boiler E10.3 Solid fuel boiler E10.5 Solar energy system F7 Safety temperature monitor K20 Contactor for 2nd heat generator K21 Contactor for immersion heater hot water M11 Primary pump for heating operation M12 Primary pump for cooling operation M13 Heat circulating pump for main circuit M14 Heat circulating pump for heating circuit 1 M15 Heat circulating pump for heating circuit 2 M16 Auxiliary circulating pump M17 Cooling circulating pump M18 Hot water circulating pump M19 Swimming pool water circulating pump M21 Mixer N1 Heating controller N2 Cooling controller for reversible heat pumps N3/N4 Room climate control stations N6 Cooling controller for passive cooling N12 Solar controller R1 External wall sensor R2/2.1 Return flow sensor R3 Hot water sensor R4 Return flow sensor for cooling water R5 Temperature sensor for heating circuit 2 R9 Flow sensor (antifreeze) R11 Flow sensor for cooling water R13 Sensor for heating circuit 3 / bivalent-renewable SMF Dirt trap TC Room temperature controller Y5 Three-way distribution valve Y6 Two-way valve Y7 Three-way mixing valve Y8 Three-way valve (closing time max. 10 sec.) Y12 External 4-way reversing valve Page 6/6 Integration Diagram: 20131020