INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK ELK 15 LEK

Similar documents
ELK 26 INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK 26

Installer manual AHP/AHPS

Installation and Operating Manual

User manual NIBE F135

LEK MOS UK VPA 300/200, 450/ INSTALLATION AND MAINTENANCE INSTRUCTIONS VPA 300/200, 450/300

User and Installer manual NIBE UKV 20

Installer manual AHP/AHPS

Installer manual SAM 40. Supply air module IHB GB LEK

Installer manual ELK 213 Immersion heater

User manual NIBE SMO 05

User manual NIBE F2016

User manual NIBE F110

User manual NIBE F , 12, 16 kw Air/water heat pump UHB GB LEK LEK LEK

User manual NIBE F130. Hot water heat pump

User manual NIBE F2040

INSTALLATION AND MAINTENANCE INSTRUCTIONS EVP EVP 500 LEK

User manual NIBE F2300

User manual NIBE SMO 05. Accessories UHB GB LEK

Installer manual SMO 40. Control module IHB GB LEK

MOS GB INSTALLATION AND MAINTENANCE INSTRUCTIONS VEDEX 1000 VEDEX 1000 M10527 LEK

BA-ST FE BA-ST FE BA-ST FE BA-ST FE BA-ST FE BA-ST FE Hot Water Storage Tank with Coil

Installer manual NIBE FLM. Exhaust air module IHB GB LEK

Installer manual SAM 40

Installer manual SMO 20. Control module IHB GB LEK

User manual NIBE SPLIT HBS 05 AMS 10-8 / / 10-16, HBS / 05-16

Installer manual NIBE ERS

User manual NIBE F2300

Operating manual NIBE F1345. Ground source heat pump OHB GB LEK

User manual NIBE F1145

Installer manual SMO 40

User manual NIBE F2120 8, 12, 16, 20

Installer manual NIBE F2026. Air/water heat pump IHB GB LEK

User manual AMS 10 AMS 10-6 / 10-8 / / 10-16

User manual NIBE F2120 8, 12, 16, 20

Installer manual NIBE ERS

Installer manual NIBE ERS

Installer manual NIBE VVM 320. Indoor module IHB GB

Installer manual NIBE VVM 310. Indoor module IHB GB

User manual NIBE VVM 500

Installer manual ELK 213 Immersion heater

Installer manual NIBE VVM 320. Indoor module IHB GB

User manual NIBE SMO 20

Installer manual NIBE VVM 500. Indoor module APH

Installer manual NIBE F135

User manual NIBE VVM 310

Installer manual NIBE VVM 310. Indoor module IHB GB

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10

Installer manual NIBE VVM 310

Installer manual NIBE VVM 500. Indoor module APH

User manual NIBE F470. Exhaust air heat pump UHB GB LEK

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10

MOS GB VEDEX INSTALLATION AND MAINTENANCE INSTRUCTIONS VEDEX 3300 LEK

Installer manual NIBE F1245. Ground source heat pump IHB GB

User manual NIBE F1255

Installer manual NIBE F1245PC. Ground source heat pump IHB GB

Installer manual NIBE VVM 500

MOS GB VEDEX 3300 M10528 INSTALLATION AND MAINTENANCE INSTRUCTIONS VEDEX 3300 LEK

User manual NIBE SMO 20

Installer manual NIBE F750. Exhaust air heat pump IHB GB LEK

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10

User manual NIBE SMO 40

INSTALLATION AND MAINTENANCE INSTRUCTIONS F F2025

Installer manual NIBE F2300. Air/water heat pump IHB GB LEK

User manual NIBE VVM 320

Installer manual NIBE SPLIT HBS 05

User manual NIBE VVM 500

Installer manual NIBE F470

Installer manual NIBE F370

Installer manual NIBE F370

User manual NIBE F470

User manual NIBE F470

Installer manual NIBE VVM 325. Indoor module IHB GB APH

Installer manual NIBE F2300. Air/water heat pump IHB GB LEK

Installer manual SMO 40

Installer manual AXC 30

NIBE SPLIT ACVM 270 Air/water heat pump

Installer manual AXC 40. Accessories IHB GB LEK

INSTALLATIONS MANUAL GV-HR110. Passive ventilation / Heat recovery. Version

NIBE F2026 air/water heat pump. fresh air s free. NIBE F2026. Efficient scroll compressor that operates at temperatures down to -20 C.

NIBE VVM 300. Intelligent hot water NIBE VVM 300. VVM 300 is designed for connection and communication

MOS GB INSTALLATION AND MAINTENANCE INSTRUCTIONS FIGHTER 1140 FIGHTER V, 3 X 230 V, 3 X 400 V LEK

INSTALLATION AND MAINTENANCE INSTRUCTIONS FIGHTER FIGHTER 1127 LEK -2 +2

INSTALLATION AND MAINTENANCE INSTRUCTIONS MOS GB NIBE VVM 300 UK NIBE VVM 300 UK 230 V VVM 300 LEK

Installer manual SMO 40

Installer manual NIBE VVM 310

MOS GB NIBE VVM INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE VVM 300 VVM 300 LEK

Installer manual NIBE F1145. Ground source heat pump IHB GB LEK

Outline principle. Application Buildings with water-borne heating systems. Alternative

Air/water - Heat pumps

Installer manual NIBE VVM 500

Outline principle. Application Buildings with water-borne heating systems. Alternative

Installer manual SMO 40

INSTALLATION AND MAINTENANCE INSTRUCTIONS AMB AMB 30 LEK

Operation and Installation Manual. Accumulation Tanks. NADO 500/200v7 NADO 750/200v7 NADO 1000/200v7

NIBE VVM 500 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER NIBE VVM 500. Flexible all-in-one indoor module for heating and hot water.

OPERATING AND INSTALLATION MANUAL

NIBE F1355. A +++ The system's efficiency class for heating. Speed-controlled ground source heat pump for large buildings. Ground source heat pump

Installation, operation and care Wall-mounted electric boiler MP THL nr. - rev 02

User manual NIBE F2026

NIBE FIGHTER 1250 A B C D E F G

Transcription:

MOS GB 1011-3 INSTALLATION AND MAINTENANCE INSTRUCTIONS 031179 LEK

Table of Contents For Home Owners General System description Principle of operation 3 Abbreviations 3 System diagram 3 Operation and maintenance General 4 Operation 4 Safety valve 4 Venting 4 Draining 4 Actions in the event of freeze risk 4 For the Installer General information for the installer Function 5 Pipe installation 5 Electrical installation 5 Draining 5 Installation alternative F1145 F1330 F20XX with SMO 10 12 Miscellaneous Electrical circuit diagram To F1145 15 1 Technical specifications Dimensions 17 Component positions 1 List of components 1 Technical specifications 19 Dealing with malfunctions Low room temperature 20 1

For Home Owners General General In order to get the ultimate benefit from you should read the "For Home Owners" section in this Installation and Maintenance Instruction. is an immersion heater primarily intended for installation together with heat pump for heating houses or smaller apartment blocks. is a Swedish-made quality product offering long life and reliable operation. The serial number* (95) must always be stated in all correspondence with NIBE. 09 Installation date Plumber Electrician Insert any notes here. Datum Sign *Serial number at left corner on the inside of This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Rights to make any design or technical modifications are reserved. NIBE 2010. 2

For Home Owners System description System description Principle of operation NIBE is an electric heater primarily intended for installation together with a heat pump for heating houses or smaller apartment blocks. contains overheating protection and contactors to externally regulate the two power groups, 5.0 and 10.0 kw. Time delay recommended in compliance with the Association of Swedish Electricity Utilities norms (always apply national regulations) when connected power output exceeds kw. The electric module is principally an immersion heater installed in a water container, or an electric boiler without domestic hot water heater. The stainless electric coils and electric boiler tube are made from acid proof steel (SIS 2333), which gives a very long service life. Economical A small water volume and a well insulated cassette mean small heat losses. Abbreviations Shut-off valve BV Non-return valve CP Circulation pump EXP Expansion vessel FG Flow line sensor RG Return line sensor RV Control valve SÄV Safety valve NOTE! This is an outline sketch. Actual installations must be planned according to applicable standards. See the relevant outline diagram for connection to the different heat pumps. System diagram Additional heat from controlled by the heat pump or the SMO. EXP SÄV CP FG RV RG BV LEK LEK 3

For Home Owners Operation and maintenance Operation and maintenance General After installing, check with the installer that the installation is in good condition. Allow the installer to show controls and functions so that you are fully aware about how to use and maintain the installation. Check that the water pressure is correct; air may remain in the system after installing. This is why bleeding and pressure checks should be carried out again. Operation Electrical output is controlled externally by the heat pump. This means that the electrical output is connected and disconnected by the additional heater. Safety valve A safety valve that is installed in the heating system, in connection with the closed expansion system, must be exercised regularly, approximately 4 times per year to maintain the safety function or according to national regulations. Venting Regularly check that there is water in the system. Air can remain in the system after installation and the radiators and boiler should be bled again. After bleeding, the pressure must be checked and water topped up if necessary. Draining If draining the system of water, the electric module must be switched off to prevent damaging the immersion heater s electric coils. Actions in the event of freeze risk In the event of extreme cold, no part of the heating system must be switched off, there is a risk of frost damage. If a part of the heating system is thought to be frozen, contact the installer. If the heating system must be switched off for a long period of time, drain the water and ensure that the immersion heater cannot be started. 4

For the Installer General information for the installer General information for the installer Function Area of use for NIBE immersion heater is in combination with NIBE ground source heat pumps and air/water heat pumps. When the heating demand is greater then heat pump's capacity, the immersion heater connects automatically as additional heat. The electrical equipment is adapted to the heat pump's function. contains overheating protection and contactors to externally regulate the two power steps, 5 and 10 kw. For optimum function the outputs should be binary controlled, i.e. 5, 10 and 15 kw. If there is no operating voltage from the heat pump, the largest power stage can be force controlled via thermostat. See the wiring diagram. Pipe installation The pipe installation must be carried out in accordance with applicable standards. by quickly opening and closing the valves. The pressure is reset by filling with water. Electrical installation must be installed via an isolator switch with a minimum breaking gap of 3 mm. NOTE Electrical installation and service must be carried out under the supervision of a qualified electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force. Power supply The immersion heater must be supplied by4xmm 2 cables, 3 x 400 V AC 50Hz, fused 3x25A.Forexample FKK 4x, FKLK4x. The cable for the operational supply must be 4 x 1,5 mm 2. NOTE Reset the temperature limiter, it may have tripped during transport. NOTE In the event of any servicing all electrical supplies must be checked and disconnected. The immersion heater can be supplied with voltage from connected heat pump. LEK Draining The system is most easily drained by installing a drain valve to the lowest point of the piping. Draining via such a valve leaves a small amount of water in the immersion heater, which is therefore drained via drain connection (71). If the unit is normally drained via the immersion heater's drain connection, install a suitable drain valve. The immersion heater must be installed standing (see image above). An area of 500 mm is required in front of the immersion heater for service work. If this is not possible, detachable connections should be used. Circulation pump must be used to ensure the flow over the immersion heater. If the heating system s valves can close the circulation completely, a by-pass must be installed to prevent the flow through the immersion heater from being stopped. When the unit is off, an approved safety valve must be installed as well as a pressure expansion vessel. The safety valves must be checked about four times a year. This is done 5

For the Installer Installation alternative Installation alternative F1145 EXP SÄV CP FG RV BV AXC 40 T SÄV VXV SF SÄV SF EL VVB VVG UG VVB/ACK BK/JK F1145 F1145 prioritises hot water charging via a shuttle valve (VXV). When the water heater/accumulator tank (HWH/ACC) is fully charged the shuttle valve (VXV) switches over to the heating circuit. The heat pump is controlled by an outside sensor combined with the flow sensor, which must be placed on the main pipe to the radiators. is connected automatically when the power demand exceeds the capacity of the heat pump. NOTE To connect to F1145, accessory AXC 40. is needed Menu settings 1. Search in "system settings" menu 5.2. 2. Select step controlled add. heat in menu 5.3. 3. Set "start addition", "diff. between additional steps", "max step" and whether binary control is to be used or not in menu 5.3.. See the appropriate "Installer manual" for F1145 for more information.

For the Installer Installation alternative Electrical connection F1145 X9 X9 9 7 5 4 3 2 PE L3 L2 L1 J2,2 J1,2 J1,1 7 5 4 7

A B A B 50.0 C Varmvattentemperatur 1.0 13.43 I II For the Installer Installation alternative F1330 SÄV EXP VBP3 FG RV HR RG BV UG VXV SÄV* T RV BV VVG VVB KB-ut B SF HR VVB / ACK P SÄV SF EXP SF KB-in A RV BV F1330 gives priority to hot water charging at half power (heat pump module B) via a shuttle valve. When the hot water heater/accumulator tank is full, the shuttle valve switches to the heating circuit. When there is a heat requirement, module A starts first. For larger requirements, module B takes care of the heating. F1330 connects in steps when the power demand exceeds the heat pump's capacity. If HWH/ACC is fitted with an immersion heater and a junction box the "Extra hot water" function can be used. A by-pass contactor is recommended. Menu settings 1. Select Electric in menu 9.1. - "Additive". 2. Select Binary in menu.2.1 - "Immersionheater type". 3. Select 2 in menu.2.2 - "Immersionheatrelays". 4. Select "1" in menu.2.3 - "Steps at 2h delay", if a restriction of the electrical power for 5 kw within 2 hours from start-up is required. 5. Select "Auto" operating mode in order for the electrical addition to be permitted to start. Check the setting of the max output on knob (101) in F1330. See the appropriate "Installation and Maintenance Instructions" for F1330 for more information.

For the Installer Installation alternative Abbreviations Shut-off valve BK/JK Rock collector/soil collector BV Non-return valve CP Circulation pump ELK Immersion heater El VVB Electric water heater HR Auxiliary relay LP Charge pump NK Level vessel SF Particle filter SÄV Safety valve FG Flow sensor VVG Hot water temperature sensor UG Outdoor temperature sensor RG Return temperature sensor VVB/ACK Accumulator with hot water heater VXV Three way valve, VST 11/VST 20 9

For the Installer Installation alternative Electrical connection F1330 Without thermostat F1330 Contactor, 1, -K1 X9 X 12 13 14 15 1 17 1 19 PE L3 L2 L1 J2,2 J1,2 J1,1 7 5 4 Contactor 2, -K2 With thermostat 10 kw immersion heater step active in emergency mode. F1330 X9 Contactor, 1, -K1 X 12 13 14 15 1 17 1 19 PE L3 L2 L1 J2,2 J1,2 J1,1 7 5 4 Contactor 2, -K2 B2 T NOTE The thermostat (B2) must be adjusted so that the temperature above the system's highest permitted temperature is not exceeded. 10

For the Installer Installation alternative Electrical connection FIGHTER 1320/1330 Without thermostat FIGHTER 1320/1330 Contactor, 1, -K1 X9 X 9 10 11 12 13 14 15 PE L3 L2 L1 J2,2 J1,2 J1,1 7 5 4 Contactor 2, -K2 With thermostat 10 kw immersion heater step active in emergency mode. FIGHTER 1320/1330 X9 Contactor, 1, -K1 X 9 10 11 12 13 14 15 PE L3 L2 L1 J2,2 J1,2 J1,1 7 5 4 Contactor 2, -K2 B2 T NOTE The thermostat (B2) must be adjusted so that the temperature above the system's highest permitted temperature is not exceeded. 11

For the Installer Installation alternative F20XX with SMO 10 SMO 10 HR P FG1* ELK CP* UKV* CP1 HR BV RG1 RV BV BV UG VXV1 SÄV VP HR LP1 VVG HR VVB/ACK SMO 10 controls heat pump, immersion heater, circulation pumps, three way valves, etc. The heat pump works with floating condensing against the heating system and prioritises hot water charging via the three way valve (VXV1). If the heat pump does not manage the heating demand, additional heat from is engaged. When additional heat is engaged, hot water is heated using the immersion heater in the hot water heater. In combined mode, the three way valve (VXV1) is open towards the heating system. Menu settings 1. Select SMO Immersion heater three way valve in menu 9.2.3 -"Docking type". 2. Select Binary in menu 9.2.12. - "Immersion heater type". 3. In menu.3.2, check that "Max. electric power permitted el.-steps" is set to "3". If necessary, check the setting on knob (101) in SMO 10. 4. Select "1" in menu 9.2.11 - "Max. step 2h", if a restriction of the electrical power for 5 kw within 2 hours from start-up is required. 5. Select "Auto" operating mode in order for the electrical addition to be permitted to start. For further information, see appropriate Installation and Maintenance Instructions for SMO 10. 12

For the Installer Installation alternative Electrical connection F20XX, SMO 10 SMO 10 provides control voltage, 230 V for output regulation. The various stages of the immersion heater are controlled by relays TS1, TS2 and TS3. NOTE Check the article number of the SMO that is installed and follow the corresponding instructions. Without thermostat 09 3 SMO 10 X9 PE Contactor, 1, -K1 L3 X L2 L1 TS2 TS1 TS3 A1 A2 A1 A2 A1 A2 20 21 22 23 24 25 J2,2 J1,2 J1,1 7 Contactor 2, -K2 5 4 With thermostat 10 kw electrical step active in emergency mode 09 3 SMO 10 X9 PE Contactor, 1, -K1 L3 TS2 TS1 TS3 A1 A2 A1 A2 A1 A2 X 20 21 22 23 24 25 L2 L1 J2,2 J1,2 J1,1 7 B2 T Contactor 2, -K2 5 4 NOTE The thermostat (B2) must be adjusted so that the temperature above the system's highest permitted temperature is not exceeded. 13

For the Installer Installation alternative Without thermostat 09 259 SMO 10 X9 PE Contactor, 1, -K1 L3 X L2 L1 20 TS2 TS1 TS3 21 22 23 24 J2,2 J1,2 J1,1 7 Contactor 2, -K2 25 5 4 With thermostat 10 kw electrical step active in emergency mode 09 259 SMO 10 X9 PE Contactor, 1, -K1 L3 TS2 TS1 TS3 X 20 21 22 23 24 L2 L1 J2,2 J1,2 J1,1 7 B2 T Contactor 2, -K2 25 5 4 NOTE The thermostat (B2) must be adjusted so that the temperature above the system's highest permitted temperature is not exceeded. 14

Miscellaneous Electrical circuit diagram Electrical circuit diagram To F1145 15

Miscellaneous Electrical circuit diagram -X9 -X9 1

Miscellaneous Technical specifications Technical specifications Dimensions Ø x4 30 15 90 300 50 530 140 0 5 200 135 240 17

Miscellaneous Technical specifications Component positions 95 1 100 70 35 10 11 71 4 5 7 J1 J1 J2 L1 L2 L3 PE 1 2 2 9 1 LEK 7 List of components 1 9 10 11 35 70 71 7 1 95 100 Immersion heater (-R1) Overheating protection (-B1) Terminal block (-X9) Contactor, 5.0 kw (-K1) Contactor, 10.0 kw (-K2) Reserve mode thermostat (-B2) Connection, flow line, G 40 Connection, return line, G 40 Cable grommet Venting Sign, serial number Mounting hole 4x(Ømm) 1

Miscellaneous Technical specifications Technical specifications IP 44 Height Width Depth Weight Volume Supply voltage Output immersion heater Fuse immersion heater Enclosure class Max permitted pressure in the boiler Material immersion heater Material tube Part No. 50 mm 240 mm 135 mm 11 kg 4.5 litres 3 x 400 V AC 50Hz 15 kw 25 A IP 44 0.7 MPa (7 bar) SIS 2333 EN 1.4301 SIS 2333 EN 1.4301 09 022 19

Miscellaneous Dealing with malfunctions Dealing with malfunctions In the event of a malfunction or disruption to normal operation, first check the points below: Low room temperature Circuit or main MCB tripped. Possible earth circuit-breaker tripped. The overheating protection has tripped. If the overheating protection has tripped, the function of the system s circulation pumps and valves must be checked. Reset by pressing in the button on the overheating protection, when the temperature has dropped below 0 C. Circulation pump stopped. Air in boiler or system. The pressure is to low in the expansion vessel. The load monitor or some external control unit may have blocked the power output. NOTE Work behind panels secured by screws may only be carried out by a qualified installation engineer. 20

AT KNV Energietechnik GmbH, Gahberggasse 11, 41 Schörfling Tel: +43 (0)72 93-0 Fax: +43 (0)72 93-44 E-mail: mail@knv.at www.knv.at CH NIBE Wärmetechnik AG, Winterthurerstrasse 710, CH-247 Flurlingen Tel: (52) 47 00 30 Fax: (52) 47 00 31 E-mail: info@nibe.ch www.nibe.ch CZ Druzstevni zavody Drazice s.r.o, Drazice 9, CZ - 294 71 Benatky nad Jizerou Tel: +420 32 373 01 Fax: +420 32 373 03 E-mail: nibe@nibe.cz www.nibe.cz DE NIBE Systemtechnik GmbH, Am Reiherpfahl 3, 29223 Celle Tel: 05141/754-0 Fax: 05141/754-99 E-mail: info@nibe.de www.nibe.de DK Vølund Varmeteknik, Filial af NIBE AB, Brogårdsvej 7, 920 Videbæk Tel: 97 17 20 33 Fax: 97 17 29 33 E-mail: info@volundvt.dk www.volundvt.dk FI NIBE Haato OY, Valimotie 27, 01510 Vantaa Puh: 09-274 97 0 Fax: 09-274 97 40 E-mail: info@haato.com www.haato.fi GB NIBE Energy Systems Ltd, 3C Broom Business Park, Bridge Way, Chesterfield S41 9QG Tel: 045 095 1200 Fax: 045 095 1201 E-mail: info@nibe.co.uk www.nibe.co.uk NL NIBE Energietechniek B.V., Postbus 2, NL-4797 ZG WILLEMSTAD (NB) Tel: 01 477722 Fax: 01 4799 E-mail: info@nibenl.nl www.nibenl.nl NO NIBE AB, Fekjan 15F, 1394 Nesbru Tel: 22 90 00 Fax: 22 90 09 E-mail: info@nibe.se www.nibevillavarme.no PL NIBE-BIAWAR Sp. z o. o. Aleja Jana Pawła II 57, 15-703 BIAŁYSTOK Tel: 05 2 4 90 Fax: 05 2 4 14 E-mail: sekretariat@biawar.com.pl www.biawar.com.pl RU "EVAN" 17, per. Boynovskiy, Nizhny Novgorod Tel./fax +7 31 419 57 0 E-mail: info@evan.ru www.nibe-evan.ru NIBE AB Sweden, Box 14, Järnvägsgatan 40, SE-25 21 Markaryd Tel: +4-(0)433-73 000 Fax: +4-(0)433-73 190 E-mail: info@nibe.se www.nibe.eu