Why Vaillant? Because the ecotec delivers day in, day out. Vaillant ecotec boiler range. The TECHNICAL Brochure

Similar documents
unistor High performance unvented stainless steel cylinder range

unistor High performance unvented stainless steel cylinder range

Why Vaillant? Because the ecotec delivers day in, day out. Vaillant ecotec boiler range. The TECHNICAL Brochure

thermocompact High performance system boiler range

Why Vaillant? Because the ecotec delivers day in, day out. Vaillant ecotec boiler range. The TECHNICAL Brochure

Why Vaillant? Because with the new ecotec Vaillant Improves Performance.

Boiler protection kit guide

ecotec range High efficiency condensing boiler range

ecotec plus New high efficiency condensing combination and system boiler ranges

Solar. domestic hot water systems. Using the sun s energy to provide hot water

Ground source heat pump range. Why Vaillant? because we can unearth the energy.

ecotec plus 937 Power store high efficiency combination boiler

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

ecomax pro High efficiency condensing boiler range for traditional systems

Domestic boiler range. Why Vaillant? because they are the choice of a professional. ecotec exclusive ecotec plus ecotec pro

aquaplus High performance combination boiler with integrated power store

Instructions for Use Installation and Servicing

aurostor Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VIH S GB...

Thermaflow. Creating Excellence, Building Reputation Unvented Water Storage From The Experts... Thermaflow Thermaflow. Thermaflow.

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Efficiency Maximiser for Solid Fuel Central Heating

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

Because our systems are the choice of a professional.

unistor Instructions for Installation and Use Unvented hot water storage cylinder

Exceeding the Standard

Hydraulic Installation

Instructions for use Installation and Servicing. Solar Hot Water Cylinders/ Flurocyl

flexotherm heat pump Why Vaillant? Because our heat pumps offer greater flexibility Comfort for your home Heating Hot water Renewables

Broag Pressurisation equipment

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

Instructions for use Installation and Servicing. Unvented Hot Water Cylinders/ Hydracyl

Exceeding the Standard

Operating instructions

Where gas is not an option,

Why Vaillant? Because there s smart and then there s vsmart. Vaillant vsmart. The USER Guide

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water

Renewable Range Cylinders providing a perfect partnership with renewable energy inputs SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

Operating instructions

Why Vaillant? aurotherm Solar Thermal. The TECHNICAL Brochure. Because we provide the best solar systems under the sun

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

turbomax plus High performance combination boiler range

ADVANCE ELECTRIC THERMAL STORE

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

Cistern-fed water heating

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

extreme HIGH EFFICIENCY HOT WATER SYSTEMS

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

ADVANCE ECB ELECTRIC COMBINATION BOILER

allstor buffer cylinder Instructions for use Instructions for use For the operator Publisher/manufacturer Vaillant GmbH

PremierPlus. and PremierPlus SystemFit. Direct and Indirect Unvented Water Heating. Unvented Water Heaters

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

ecotec pro Operating instructions Operating instructions For the operator GB, IE Gas-fired wall-hung high-efficiency boiler

For latest prices and delivery to your door visit MyTub Ltd

the electric heating company ELECTRIC BOILER HANDBOOK

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Redring Powerstream Electric Flow Boilers. Efficient, safe and convenient electric space and water heating

Stainless Steel Unvented Cylinders

CI/SfB. (53.3) x. October Unvented Water Heaters. PremierPlus. Unvented Hot Water Cylinders

INTERCYL. INTERNAL EXPANSION EXCELLENCE

WALL-HUNG SYSTEM & UNVENTED CYLINDERS

Kills bills. How Vaillant technologies reduce home heating bills

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

WRAS TEST & ACCEPTANCE CRITERIA Issue No: 1 Date of issue: October Sheet 1 of 7

Multipoint Technical Data

SOLAR HEATING SYSTEMS

Unvented Water Heating. Zircon

PRODUCT GUIDE 2018/19 ACV HEATING AND HOT WATER SPECIALISTS

Alpha FlowSmart 25 and 50

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Installation, Operation and Maintenance Instructions Electric Flow Heater OM009

A Hot water revolution

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

A HOT WATER REVOLUTION

CPC-150-ABIAB. Important Installation Notes.

The xi Range of High Efficiency Condensing Boilers. hxi Range 12-38kW

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

QUALITY DESIGN. BUILT-IN RELIABILITY. CYLINDERS. The complete range of Warmflow Cylinders.

STAINLESSLITE ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

UK arotherm Schematics and installation guide

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

UNVENTED WATER HEATERS. Water Heater Display Stand

The new ecotec exclusive from Vaillant with Green iq technology

Installation Instructions

UNVENTED STAINLESS STEEL CYLINDERS

Assessment Schedule - TS.6

Water Heating UK 14 th May 2016

Commercial Hot Water Solutions Ltd.

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

Air to air heat pump range. Why Vaillant? because there is something in the air.

Saving energy comes naturally to us.

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously)

H o t Wa te r Syste m s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

JASPI GTV & Oval thermal storage

SEALED THERMAL STORE

EFFICIENCY THERMAL STORAGE SYSTEMS

Transcription:

Why Vaillant? Because the ecotec delivers day in, day out Vaillant ecotec boiler range The TECHNICAL Brochure

The TECHNICAL Brochure UniSTOR unvented cylinders is a range of six high grade stainless steel unvented cylinders from Vaillant. Finished with stylish casing, they are available in a range of sizes from 120 litres to 310 litres. 54 The stainless steel cylinder range can be used together with any Vaillant system and open vent boiler (or any existing system or open vent boiler). They work in perfection when used with the ecotec range of system boilers, where they can make full use of Vaillant s intelligent ebus temperature sensing controls as part of Vaillant s Total System Solution. Key features and benefits: cylinders operate using a mains water pressure supply and do not require a feed from a cold water storage tank All necessary cold and hot water controls and a 2-port valve for control of domestic hot water are supplied All cylinders are backed by a full 2 year guarantee as well as a 25 year guarantee on the cylinder shell Complete with G3 kit and expansion vessel

UniSTOR unvented cylinders stainless steel unvented cylinder 120 155 180 210 260 310 Article number 0010010900 0010010901 0010010902 0010010903 0010010904 0010010905 External case height (mm) 1001 1191 1371 1593 1843 2153 Diameter (mm) 554.5 554.5 554.5 554.5 554.5 554.5 Approx weight when empty (Kg) 26 29 32 36 41 46 55

technical specification 120 / 155 / 180 / 210 / 260 / 310L Technical data Unit 120 155 180 Article number 0010010900 0010010901 0010010902 Total capacity l 120 155 180 Actual capacity l 119.2 149.1 176.6 Hot water capacity l 1040 1367 1664 210 260 310 0010010903 0010010904 0010010905 210 260 310 211.2 250.3 298.5 2039 2475 2705 Maximum supply pressure to pressure reducing valve MPa (bar) 1.2 (12) 1.2 (12) Rated pressure of cylinder MPa (bar) 0.7 (7) 0.7 (7) Maximum operating pressure of heating coil MPa (bar) 0.35 (3.5) 0.35 (3.5) Pressure reducing valve MPa (bar) 0.35 (3.5) Expansion relief valve MPa (bar) 0.6 (6.0) 0.35 (3.5) 0.6 (6.0) Temperature and pressure relief valve C MPa (bar) 90 0.7 (7) 90 0.7 (7) Charge pressure of hot water expansion vessel MPa (bar) 0.4 (4) 0.4 (4) Maximum temperature of heating circuit C 85 85 Maximum temperature of potable hot water C 85 85 Standing heat loss kw/24 h 1.26 1.53 1.66 1.89 2.07 2.26 Heat up time according to EN 12897 mins 18 23 24 28 35 42 Recovery time (70% capacity) kw 16 18 17 20 25 30 performance l/min 18.6 18.8 22.0 22.6 22.3 20.4 Flow rate for primary heat exchanger performance l/min 23.3 23.3 pressure drop mbar 97 97 116 116 116 115 volume l 2.94 2.94 3.56 3.56 3.56 3.56 surface area m 2 0.62 0.62 0.75 0.75 0.75 0.75 56

120 / 155 / 180 / 210 / 260 / 310L Technical data Unit 120 155 180 Article number 0010010900 0010010901 0010010902 Height mm 1001 1191 1371 Height with hot water draw off l 1033 1223 1403 Topple measure mm 1138 1308 1473 Diameter mm 554.5 Depth mm 633 Net weight kg 26 29 32 Weight (full) kg 145 177.8 209 Connections 210 260 310 0010010903 0010010904 0010010905 1593 1843 2153 1625 1875 2185 1680 1918 2217 554.5 633 36 41 46 248 291 345 UniSTOR unvented cylinders Cold water inlet Hot water draw off Pressure-controlled cold water inlet Secondary return Primary heater flow Primary heater return Primary heating circuit immersion sleeve size Electrical connections Immersion heater (according to ENBS 60335) 15mm unprofiled pipe (crimp joints) mm 8 2.7 kw, 230 V, 50 Hz 15mm unprofiled pipe (crimp joints) 8 2.7 kw, 230 V, 50 Hz Length of immersion heater inch 14 14 Two port motorised valve Cylinder thermostat Material data Cylinder body material Stainless steel (1.4521) Stainless steel (1.4521) Cylinder jacket material Insulation material Polypropylene EPS with heat radiation absorber Polypropylene EPS with heat radiation absorber Insulation thickness mm 50 50 Corrosion protection Blowing agent for insulation material Stainless steel Pentane (GWP < 5) Stainless steel Pentane (GWP < 5) Ozone Depletion Potential 0 0 57

Training Enquiries After Sales For information on training courses and centres in your area: Telephone: 0845 601 8885 Email: training@vaillant.co.uk For support after your boiler has been installed, whether you would like to book a service or are in need of technical advice, our operators are available 7 days a week, 364 days a year. Telephone: 0330 100 3143 Sales Enquiries Technical Enquiries For installers wishing to purchase Vaillant products, this is possible either over the counter or as a next day service at most plumbing and heating merchants in the UK. To find contact details for your nearest Vaillant sales representative: Telephone: 0845 602 0262 For technical assistance: Telephone: 01732 878803 Email: technical@vaillant.co.uk Vaillant Group UK Ltd. Nottingham Road, Belper, Derbyshire DE56 1JT www.vaillant.co.uk info@vaillant.co.uk 72 VAECOTEC V2 June 15