UNVENTED STAINLESS STEEL CYLINDERS

Similar documents
H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Exceeding the Standard

Exceeding the Standard

H o t Wa te r Syste m s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

POINT OF USE WATER HEATERS

Re n ewa b l e s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

INTERCYL. INTERNAL EXPANSION EXCELLENCE

ADVANCED WATER COMPANY LTD COPPERFORM. Advanced Water Company Ltd. Unvented Hot Water Cylinders. Supplied By Advanced Water Company Ltd

PremierPlus. and PremierPlus SystemFit. Direct and Indirect Unvented Water Heating. Unvented Water Heaters

EXCELLENCE IN HOT WATER TECHNOLOGY CYLINDER PRODUCT GUIDE

Thermaflow. Creating Excellence, Building Reputation Unvented Water Storage From The Experts... Thermaflow Thermaflow. Thermaflow.

Stainless Steel Unvented Cylinders

Flomaster. Unvented Hot Water Cylinders INSTALLATION INSTRUCTIONS FOR COPPERFORM FLOMASTER UNVENTED CYLINDERS: DIRECT, INDIRECT AND SOLAR MODELS.

H o t Wa te r Syste m s. Unvented Copper Hot Water Cylinders for Heat Pump and Solar Input. Exceeding the Standard

R e n e w a b l e s. Tribune HE Unvented Hot Water Cylinders Installation and Maintenance Instructions. Issue 14 May 2011 Part No.

Unvented Water Heating. Zircon

Unvented Hot Water Systems for the Professionals

Unvented Copper Hot Water Cylinders

Series 1000 & Storage Water Heaters

Unvented Copper Hot Water Cylinders

Cistern-fed water heating

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

Total Hot Water Solutions

QUALITY DESIGN. BUILT-IN RELIABILITY. CYLINDERS. The complete range of Warmflow Cylinders.

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living

Discover the ALL new Range Tribune Xe Engineered for maximum EFFICIENCY

Unvented water heating

EVERFLO RAPIDE PLUS - INSTALLATION AND MAINTENANCE INTRUCTIONS

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

CI/SfB. (53.3) x. October Unvented Water Heaters. PremierPlus. Unvented Hot Water Cylinders

Multipoint Technical Data

Unvented water heaters

STAINLESSLITE ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

Megaflo eco Unvented hot water cylinders

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

Flomaster Installation & Maintenance Instructions for an unvented hot water cylinder with external thermal expansion

H ot Wa te r Syste m s. Copper Hot Water Products. Total Hot Water Solutions

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

SOLAR HEATING SYSTEMS

Instructions for Use Installation and Servicing

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

THERMAL STORE MAINS PRESSURE SYSTEM

Combined electric boiler and domestic hot water store

Unvented water heating

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Renewable Range Cylinders providing a perfect partnership with renewable energy inputs SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

Water Heating Systems

HEATBANK Xcel Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

ZIP AquaFlo II. Models: Direct, Indirect and Solar Compatible. Unvented cylinder water heaters

A Hot water revolution

EcoSeries S O L A R H O T WAT E R S O L U T I O N S. Ecological & Economical

MEGAFLO HE Iss 1

Xcel HEATBANK Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

THERMAL STORE MAINS PRESSURE SYSTEM

A HOT WATER REVOLUTION

APP STAINLESS UNVENTED HORIZONTAL HOT WATER CYLINDERS

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

unistor High performance unvented stainless steel cylinder range

Grant Wave range. High efficiency direct and indirect hot water storage solutions

the electric heating company ELECTRIC BOILER HANDBOOK

Compact HRE Boiler Range. The smart choice for heating and hot water

For latest prices and delivery to your door visit MyTub Ltd

XCEL HEAT BANKS Installation Instructions. Thermal Integration Ltd., 1-3 Wealdstone Road, Sutton, Surrey SM3 9QN.

Megaflo eco. Unvented hot water cylinders

Regulations, Legislation and Byelaws

unistor High performance unvented stainless steel cylinder range

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

VENTED CYLINDER RANGE

Unvented Hot Water Systems for the Professionals

Unvented Direct & Indirect Hot Water Cylinders (400L L)

WATER HEATERS INSTALLATION MANUAL

Solar thermal domestic hot water system

Unvented Water Heaters. September Aqualine. Unvented Electric Water Heating

Amptec. Electric flow boiler

Compact HRE and ECO RF Boiler Range. The smart choice for heating and hot water

Installation Manual EXCELSIOR Unvented Water Heater

Hotflo. Unvented point of use hot water

RANGE TRibuNE HE unvented HoT WATER CyliNdERs installation ANd MAiNTENANCE instructions issue 20 february 2014

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water

SEALED THERMAL STORE

TORRENT STAINLESS INSTRUCTION MANUAL DESIGN, INSTALLATION & SERVICING ONE NAME. EVERY SOLUTION.

Performance on demand

Unvented Direct & Indirect Hot Water Cylinders (400L L)

H ot Wa te r Syste m s. Copper Hot Water Products. Making Life Simpler

Transcription:

Hot Water Energy Storage UNVENTED STAINLESS STEEL CYLINDERS RELIABLE HOT WATER THROUGHOUT THE HOME THE HOT WATER PEOPLE NEW ULTRASTEEL PLUS CYLINDERS EATURING BUILT-IN EXPANSION SPACE! SEE PAGE 4

Hot Water Energy Storage THE HOT WATER PEOPLE Providing practical hot water solutions for the refurbishment and retrofit market HOT WATER CYLINDERS ROM KINGSPAN ALBION or over 60 years, Kingspan Albion has been designing and manufacturing products that store and deliver consistently reliable hot water throughout people s homes. Our unvented hot water cylinders have continued to meet the evolving and demanding hot water needs of the UK homes. ollowing ongoing investment in research and development, the Kingspan Albion Ultrasteel cylinder was launched in 2008, and the latest addition to the range is the Ultrasteel Plus. All Kingspan Albion cylinders are known for their outstanding reliability and straight forward functionality. Our commitment to quality and standards is demonstrated by our BS EN ISO 9001:2008 accreditation. With a simple maintenance schedule, they will reliably store and generate hot water for years to come. Kingspan Albion has been part of the Kingspan Group PLC since 2005. As well as the high level of customer service you d expect, we offer a technical specialist helpline giving confidence that we can support you over the lifetime of your product and beyond. This brochure includes information about when to use a hot water cylinder, the features and technical specifications of the Albion Ultrasteel and Ultrasteel Plus ranges, how to choose and install the right sized cylinder for the job, and details of the high-grade materials used in every Kingspan Albion unvented hot water cylinder. CONTENTS Hot Water Cylinders from Kingspan Albion 2 When to Use Hot Water Cylinders 3 Built-in Thermal Expansion Space 4 Introducing Ultrasteel Plus 5 Technical Data - Ultrasteel Plus 6 Direct, Indirect and Solar Indirect Cylinders Introducing Ultrasteel 9 Technical Data - Ultrasteel 10 Direct, Indirect and Solar Indirect Cylinders Ultrasteel Plus & Ultrasteel Kits 12 Choosing the Right Cylinder 13 Installing Ultrasteel Plus and 14 Ultrasteel Cylinders Standards and Specifications 15 2

KINGSPAN ALBION RELIABLE HOT WATER CYLINDERS WHEN TO USE HOT WATER CYLINDERS IT S MORE OTEN THAN YOU MIGHT THINK! QUALITY We use high-grade duplex stainless steel to ensure Ultrasteel Plus and Ultrasteel cylinders are resistant to corrosion. That means we can back every Ultrasteel Plus and Ultrasteel cylinder with a 25-year guarantee*, with a 2-year guarantee* on parts supplied. Is this hot water system capable of meeting the demands it could face? That s the crucial question you can ask yourself when working with your customers on adaptations, retrofits and extensions to their home. If the answer is no, it s an opportunity for you to upgrade your customer to an unvented hot water cylinder. Whilst combi boilers are just the job for smaller homes with only one bathroom, they can be left flagging when using more than one hot water outlet at the same time. If your customer is adding a bathroom, building an extension for a new utility room or a workshop with hot water, it could be time to consider adding an element of stored hot water to the system. It s no good installing the most luxurious en-suite shower or beautiful new bathroom if your customer is left disappointed because the bath takes forever to fill or the shower becomes a trickle as soon as someone turns on the kitchen sink tap. That s where hot water cylinders are the best product for the job. Whether it s in a home with one bathroom and an en-suite, or in a multiple-occupancy home with four or five bathrooms, they can handle hot water being used simultaneously in multiple places throughout the home. or more information on which size of cylinder best suits a home s hot water needs, see page 13. KINGSPAN ALBION UNVENTED HOT WATER CYLINDERS The Kingspan Albion series of hot water cylinders comprises two ranges Ultrasteel Plus and Ultrasteel. The NEW Ultrasteel Plus series has the thermal expansion space built-in. This results in simpler installation, maintenance, and makes the most efficient use of a customer's airing cupboard or loft space. The Ultrasteel is our original and trusted range, with a separate thermal expansion vessel. Both the Ultrasteel Plus and the Ultrasteel have three models which can be selected depending on the type of heat source required Direct, Indirect and Solar Indirect. UNCTIONALITY Kingspan Albion cylinders are known for their high build quality, fast flow rates and energy-efficient insulation. The sleek looks of the Ultrasteel Plus and the Ultrasteel make them winners for both practicality and style. RELIABILITY Every Kingspan Albion Ultrasteel Plus and Ultrasteel cylinder is individually pressure-tested up to 15 bar ensuring it s mechanically strong and watertight. * See installation instructions for full terms and conditions 3

Hot Water Energy Storage ULTRASTEEL PLUS BUILT-IN THERMAL EXPANSION SPACE HASSLE REE INSTALLATION AND SETUP UNCTIONAL & PRACTICAL MEETING YOUR EVERYDAY NEEDS When the water is cold When the water is hot No need for an external expansion vessel, saving an average 2m of 22mm copper tube per installation Quicker, simpler to fit; save up to 20 minutes on a typical retrofit installation Improved reliability for a reduced risk of call back 4

KINGSPAN ALBION RELIABLE HOT WATER CYLINDERS THE HOT WATER PEOPLE INTRODUCING ULTRASTEEL PLUS The latest addition to the Kingspan Albion portfolio, the Ultrasteel Plus takes all the best practical features of the popular Ultrasteel and adds extra functionality to make homeowners and installers' lives even easier. With built-in thermal expansion rather than a separate thermal expansion vessel annual maintenance of the Ultrasteel Plus has the ultimate no hassle factor. Incorporating thermal expansion capabilities into the cylinder itself saves precious airing cupboard space. The outlet on the Ultrasteel Plus is on the side rather than on the top of the unit which means a homeowner can install shelving above the cylinder. It also gives easier access for installation and maintanance. The Ultrasteel Plus provides all the features that make its sister product, the Ultrasteel, so popular with installers high build quality including duplex stainless steel, fast flow rates, quick recovery coils and energy-efficient insulation. Key eatures: Built-in thermal expansion saves space and aids annual maintenance Mains pressure hot water (regulated up to 3 bar) for powerful showers High flow rates for fast filling of baths, ideal for multiple bathrooms Well insulated economical to run with low heat loss Low reheat times for fast availability of hot water Duplex stainless steel basic vessel with superior corrosion resistance and aesthetically pleasing outer case Available in capacities from 120-300 litres With a choice of three models available for Direct, Indirect or Solar Indirect heat sources, Ultrasteel Plus is an ideal option for every homeowner, regardless of their current heating system. 5

Hot Water Energy Storage TECHNICAL DATA ULTRASTEEL PLUS DIRECT CYLINDERS Ultrasteel Plus Direct cylinders heat quickly and directly through the 3kW electric immersion heater. All models feature a back-up immersion heater, which can also act as a boost or secondary heat source. Always isolate from the electricity supply before working on the product. DIRECT CYLINDERS Code Heat-up Time (Minutes) Immersion Heaters (3kW) B E AUX20 62 2 AUX50 77 2 AUX80 93 2 AUXD210 108 2 AUXD250 129 2 AUXD300 153 2 C2 INDIRECT CYLINDERS Ultrasteel Plus Indirect cylinders heat up rapidly through the connection of the primary heating coil to a gas or oil boiler. They also feature a back-up immersion heater, which can act as a boost or secondary heat source. C1 A Code Heat-up Time (Minutes) Coil Rating (kw) Immersion Heaters (3kW) AUXN120 21 14.44 1 AUXN150 24 16.85 1 AUXN180 27 18.88 1 AUXN210 31 17.08 1 AUXN250 33 20.31 2 AUXN300 42 19.61 2 CONNECTIONS: A 22mm Cold feed with dip pipe to diffuser in bottom of cylinder B 22m Hot water outlet SOLAR INDIRECT CYLINDERS Designed with two indirect heating coils. The primary coil connects to a solar thermal system and the secondary coil to a gas or oil boiler, which provides heat when there is insufficient input from the solar heat source. They also feature a back-up immersion heater. Code Designated Solar Volume (L) ossil uel Volume (L) Immersion Heaters (3kW) Surface Area Solar Coil (m2) luid Content Solar Coil (L) AUXSN180 99 76 1 0.76 4.21 AUXSN210 119 82 1 0.86 4.75 AUXSN250 124 119 1 0.86 4.75 AUXSN300 124 161 1 0.96 5.28 C1 Immersion heater* C2 Secondary immersion heater* - Direct cylinders and 250 & 300 litre Indirect cylinders only 22mm Boiler coil connections D2 22mm Solar coil connections E 1 2 " Temperature relief valve connection (valve factory-fitted to cylinder) 22mm Secondary return for cylinders with a capacity of 210 litres and above only G1 Dry stat pocket solar control G2 Dry stat pocket high limit 6

KINGSPAN ALBION RELIABLE HOT WATER CYLINDERS THE HOT WATER PEOPLE INDIRECT CYLINDERS SOLAR INDIRECT CYLINDERS G2 B E B E C2 C1 C1 A G1 A D2 D2 Boss centre from floor ErP Cylinder type and Code Capacity (Litres) Height Dia. A B C1* C2* D2 E G1 G2 Rating Standing Loss, (W) Load Profile Efficiency kwh/ year AUX20 120 997 550 184 651 244 532 n/a n/a 619 n/a n/a n/a D n/a M 33% 1490 AUX50 150 1183 550 184 837 244 632 n/a n/a 805 n/a n/a n/a D n/a L 36% 2781 DIRECT AUX80 180 1367 550 184 1021 244 732 n/a n/a 989 n/a n/a n/a D n/a L 35% 2832 AUXD210 210 1557 550 184 1087 244 832 n/a n/a 1055 1022 n/a n/a D n/a L 34% 2876 AUXD250 250 1802 550 184 1332 244 972 n/a n/a 1300 1267 n/a n/a D n/a XL 36% 4548 AUXD300 300 2072 550 184 1584 244 1123 n/a n/a 1552 1519 n/a n/a D n/a XL 36% 4567 AUXN120 120 997 550 455 651 355 n/a 315 n/a 619 n/a n/a n/a B 49 n/a n/a n/a AUXN150 150 1183 550 455 837 385 n/a 345 n/a 805 n/a n/a n/a B 52 n/a n/a n/a INDIRECT AUXN180 180 1367 550 490 1021 415 n/a 375 n/a 989 n/a n/a n/a C 65 n/a n/a n/a AUXN210 210 1557 550 490 1087 415 n/a 375 n/a 1055 1022 n/a n/a C 76 n/a n/a n/a AUXN250 250 1802 550 530 1332 450 1005 410 n/a 1300 1267 n/a n/a C 87 n/a n/a n/a AUXN300 300 2072 550 530 1584 450 1255 410 n/a 1552 1519 n/a n/a C 91 n/a n/a n/a SOLAR INDIRECT AUXSN180 180 1367 550 530 1021 910 n/a 855 345 989 n/a 400 1021 C 65 n/a n/a n/a AUXSN210 210 1557 550 530 1087 960 n/a 905 375 1055 1022 430 1087 C 76 n/a n/a n/a AUXSN250 250 1802 550 530 1332 1030 n/a 975 375 1300 1267 430 1332 C 87 n/a n/a n/a AUXSN300 300 2072 550 530 1584 1060 n/a 1005 410 1552 1519 465 1584 C 91 n/a n/a n/a * Not to be used as the primary heat source on indirect or solar indirect cylinders 7

Hot Water Energy Storage ULTRASTEEL PLUS AND ULTRASTEEL PROVIDING PEACE O MIND BRITISH MANUACTURED AND INDIVIDUALLY PRESSURE TESTED TO 15 BAR 8

KINGSPAN ALBION RELIABLE HOT WATER CYLINDERS THE HOT WATER PEOPLE INTRODUCING ULTRASTEEL The practical Ultrasteel series has been one of Kingspan Albion s most popular stainless steel unvented hot water cylinders since its launch in 2008. Made from high-grade engineering materials such as duplex stainless steel and tried and tested components such as valves, control sets and thermostats, the Ultrasteel s functional features strike the perfect balance for installers and homeowners between reliability, aesthetics and good value. Quick recovery coils mean homeowners have low reheat times for the fast availability of hot water. High flow rates are perfect for multiple bathrooms and energy-efficient insulation keeps running costs low. Key eatures: Mains pressure hot water (regulated up to 3 bar) for powerful showers Good flow rates for fast filling of baths, ideal for multiple bathrooms Well insulated economical to run with low heat loss Low reheat times for fast availability of hot water Duplex stainless steel basic vessel with superior corrosion resistance and aesthetically pleasing outer case Available in capacities from 120-300 litres With a choice of three models available for Direct, Indirect or Solar Indirect heat sources homeowners can choose the model that suits them, regardless of their current heating system. 9

Hot Water Energy Storage TECHNICAL DATA ULTRASTEEL DIRECT CYLINDERS Ultrasteel Direct cylinders heat quickly and directly through the built-in 3kW electric immersion heater. All models feature a back-up immersion heater, which can also act as a boost or secondary heat source. Always isolate from the electricity supply before working on the product. B DIRECT CYLINDERS Code Heat-up Time (Minutes) Immersion Heaters (3kW) E AUX20 110 2 AUX50 135 2 AUX80 160 2 AUXD210 185 2 AUXD250 225 2 AUXD300 270 2 C2 INDIRECT CYLINDERS Ultrasteel Indirect cylinders heat up rapidly through the connection of the primary heating coil to a gas or oil boiler. They also feature a back-up immersion heater, which can act as a boost or secondary heat source. C1 A Code Heat-up Time (Minutes) Coil Rating (kw) Immersion Heaters (3kW) AUN120 22 15.51 1 AUN150 25 16.76 1 AUN180 28 17.44 1 AUN210 30 19.68 1 AUN250 34 20.95 2 AUN300 44 21 2 CONNECTIONS: A 22mm Cold feed with deflector in bottom of cylinder B 22m Hot water outlet SOLAR INDIRECT CYLINDERS Designed with two indirect heating coils. The primary coil connects to a solar thermal system, and the secondary coil to a gas or oil boiler, which provides heat when there is insufficient input from the solar heat source.at source. They also feature a back-up immersion heater. Code Designated Solar Volume (L) ossil uel Volume (L) Immersion Heaters (3kW) Surface Area Solar Coil (m2) luid Content Solar Coil (L) AUSN180 55 125 1 0.76 4.21 AUSN210 65 145 1 0.86 4.75 AUSN250 90 160 1 0.86 4.75 AUSN300 100 200 1 0.96 5.28 C1 Immersion heater* C2 Secondary immersion heater* - Direct cylinders and 250 & 300 litre Indirect cylinders only 22mm Boiler coil connections D2 22mm Solar coil connections E 1 2 " Temperature relief valve connection (valve factory-fitted to all cylinder). High limit dry stat pocket on solar models. 22mm Secondary return for cylinders with a capacity of 210 litres and above only G1 Dry stat pocket boiler G2 Dry stat pocket solar control 10

KINGSPAN ALBION RELIABLE HOT WATER CYLINDERS THE HOT WATER PEOPLE INDIRECT CYLINDERS SOLAR INDIRECT CYLINDERS B B E E E G1 C2 G1 C1 G2 C1 D2 D2 A A Boss centre from floor ErP Cylinder type and Code Capacity (Litres) Height Dia. A B C1* C2* D2 E G1 G2 Rating Standing Loss, (W) Load Profile Efficiency kwh/ year AU20 120 927 550 178 927 198 511 n/a n/a 707 n/a n/a n/a D n/a M 34 1461 AU50 150 1114 550 178 1114 198 611 n/a n/a 894 n/a n/a n/a D n/a M 36 1492 DIRECT AU80 180 1302 550 178 1302 198 711 n/a n/a 1082 n/a n/a n/a D n/a L 35 2783 AUD210 210 1490 550 178 1490 198 811 n/a n/a 1270 1051 n/a n/a D n/a L 34 2827 AUD250 250 1740 550 178 1740 198 951 n/a n/a 1520 1401 n/a n/a D n/a L 34 2871 AUD300 300 2053 550 178 2053 198 1101 n/a n/a 1833 1601 n/a n/a D n/a XL 36 4543 AUI120 120 927 550 178 927 346 n/a 291 n/a 709 n/a 361 n/a B 44 n/a n/a n/a AUI150 150 1114 550 178 1114 386 n/a 331 n/a 896 n/a 401 n/a B 51 n/a n/a n/a INDIRECT AUI180 180 1302 550 178 1302 386 n/a 331 n/a 1084 n/a 401 n/a B 55 n/a n/a n/a AUI210 210 1490 550 178 1490 421 n/a 366 n/a 1272 1051 481 n/a C 66 n/a n/a n/a AUI250 250 1740 550 178 1740 421 951 366 n/a 1522 1401 576 n/a C 77 n/a n/a n/a AUI300 300 2053 550 178 2053 421 1101 366 n/a 1835 1601 676 n/a C 88 n/a n/a n/a SOLAR INDIRECT AUSI180 180 1302 550 178 1302 730 n/a 675 291 1084 n/a 730 346 B 55 n/a n/a n/a AUSI210 210 1490 550 178 1490 835 n/a 780 366 1272 1151 835 421 C 66 n/a n/a n/a AUSI250 250 1740 550 178 1740 1006 n/a 951 366 1522 1401 1006 421 C 77 n/a n/a n/a AUSI300 300 2053 550 178 2053 1038 n/a 980 366 1835 1601 1035 421 C 88 n/a n/a n/a * Not to be used as the primary heat source on indirect or solar indirect cylinders 11

Hot Water Energy Storage ITTINGS INCLUDED AS STANDARD ULTRASTEEL AND ULTRASTEEL PLUS CYLINDERS ARE SUPPLIED COMPLETE WITH ALL THE ITTINGS YOU NEED Expansion Vessel Thermostatic Control Immersion Heater Two-port Valve Tundish Temperature and Pressure Relief Valve High low Rate Inlet Control Set ULTRASTEEL PLUS Built-in thermal expansion space; no vessel required Intergrated into immersion heater and pre-fitted to cylinder 3 kw Incoloy long life High quality Honeywell valve 1 2 " BSP 10 Bar / 90 C ULTRASTEEL 12 Litre vessel on 120 & 150 litre cylinders 19 Litre vessel on 180 to 250 litre cylinders 24 Litre vessel on 300 litre cylinders Dual Thermostat 3 kw Incoloy long life High quality Honeywell valve 1 2 " NPT 7 Bar / 90 C ittings supplied with Ultrasteel Plus and Ultrasteel Cylinders Direct Models (electric) Indirect Models Solar Indirect Models Ultrasteel Plus Ultrasteel Ultrasteel Plus Ultrasteel Ultrasteel Plus Ultrasteel INLET CONTROL SET X X X X X X TEMPERATURE AND PRESSURE RELIE VALVE X X X X X X 15MM / 22MM TUNDISH X X X X X X EXPANSION VESSEL X X X PRIMARY 3KW IMMERSION HEATER X X X X X X SECONDARY 3KW IMMERSION HEATERS 250 & 300 litre units 250 & 300 litre units 250 & 300 litre units 250 & 300 litre units X X 1 X TWO-PORT VALVE X X X X X X 1 X DUAL THERMOSTAT X X X 1 X DUAL THERMOSTAT INTERGRATED INTO IMMERSION HEATER X X X 1 X SINGLE HIGH LIMIT STAT X X 2 X SENSOR POCKET RETAINING BUNGS X X INSTALLATION & MAINTENANCE MANUAL AND BENCHMARK LOG X X X X X X 12

KINGSPAN ALBION RELIABLE HOT WATER CYLINDERS THE HOT WATER PEOPLE CHOOSING THE RIGHT KINGSPAN ALBION CYLINDER Unvented hot water cylinders can handle hot water being used in multiple places throughout the home simultaneously without loss of temperature or pressure. SELECTING THE RIGHT ULTRASTEEL OR ULTRASTEEL PLUS CYLINDER OR THE JOB Stored hot water is ideal for larger properties but is also suitable for small homes with just one bath/ shower, especially when mains gas is not an option. LOW RATES Ultrasteel Plus and Ultrasteel are renowned for their fast flow rates. The diagrams here illustrate the speed at which hot water can be heated and distributed reliably throughout the home. Hot water demand Bedrooms Indirect cylinder capacity (litres) Direct cylinder capacity (litres) 1 standard bath or shower 1 standard bath 1 bath and en-suite 2 standard baths Bedsit/1 bed 120 150 2-3 bed 120 180 3-4 bed 150 210 2-3 bed 120 180 3-4 bed 150 210 2-3 bed 150 210 3-4 bed 150 210 4-5 bed 180 250 2-3 bed 180 210 3-4 bed 180 210 4-5 bed 210 250 3 bathrooms 3-4 bed 250 300 low rate ltrs/min 50 45 40 35 30 25 20 15 10 low rate with just a hot tap open low rate with both hot tap and cold tap open 4-5 bed 250 300 5 5-6 bed 300 300 0 0.5 1 1.5 2 2.5 3 3.5 4.0 Static Supply Pressure - bar 13

Hot Water Energy Storage INSTALLING ULTRASTEEL PLUS AND ULTRASTEEL CYLINDERS Qualified installer All unvented units with a capacity over 15 litres must be installed by a competent installer in line with the following regulations: England and Wales Building Regulations G3 Scotland Technical Standard P3 Northern Ireland Building Regulations P5 Location With no header tanks to consider, Ultrasteel and Ultrasteel Plus units can be sited almost anywhere in the home and supply outlets both above and below its location. With Ultrasteel Plus, the side-mounted hot water outlet gives greater flexibility to the homeowner, as the cylinder can be installed under shelving or other equipment. Water supply An adequate and reliable mains water supply is essential to ensure Albion Ultrasteel and Ultrasteel Plus cylinders deliver the quality and reliable performance you d expect. We recommend a minimum supply pressure of 1.0 bar, with a flow rate of 25 litres/min. Compatible boilers Ultrasteel and Ultrasteel Plus cylinders are compatible with gas, electric or oil fired boilers fitted with an integral control thermostat and cut-out. Any heat source that lacks full thermostatic control cannot typically be connected to unvented systems such as the Ultrasteel or Ultrasteel Plus. This includes most solid fuel boilers e.g. Agas, Rayburns and Stanleys. The primary circuit may be open vented or sealed, operating at up to 7 bar. The primary circuit must be pumped. Connection sizes Hot and cold inlets, coil connections 22mm compression* Safety valves 15mm compression outlet Inlet control set 22mm compressing inlet and outlet Tundish 15mm compression inlet / 22mm compression outlet * This is not a standard 3 4 " BSP thread. Only use the compression nuts supplied with the cylinder. Secondary return A dedicated 22mm secondary return connection is fitted to the 210, 250 and 300 litre cylinders. A swept tee (not supplied) can be used to provide a secondary return on 120, 150 and 180 litre cylinders. Electrical wiring All electrical wiring must comply with the latest IEE wiring regulations. Wire the controls to the boiler/programmer in accordance with the control system used. Albion Ultrasteel and Ultrasteel Plus cylinders can be used with W or S Plan layouts, although an S Plan layout will reduce installation costs as Kingspan already supply one of the two port vales required. Always isolate from the electricity supply before working on the product. Each immersion heater must have a permanent connection via a double-pole linked isolating switch with a minimum rating of 13 amp. Cylinder Weight Always ensure Ultrasteel and Ultrasteel Plus cylinders are installed vertically on a flat surface capable of supporting the weight of a plumbed cylinder when full Cylinder Capacity Weight when full (kg) 120L 155 150L 193 180L 230 210L 265 250L 310 300L 372 14

KINGSPAN ALBION RELIABLE HOT WATER CYLINDERS THE HOT WATER PEOPLE STANDARDS AND SPECIICATIONS Materials Ultrasteel and Ultrasteel Plus Inner shell duplex stainless steel Coil 22mm diameter stainless steel Bosses stainless steel Polyurethane CC- and HCC-free foam insulation, nominal thickness 50mm. This insulation has an Ozone Depletion Potential of Zero and a Global Warming Potential of 3.1. Casing galvanized steel, durable finish Anode none fitted/required Immersion heater 1 3 4 " BSP parallel threaded head Long life incology sheathed low noise element and thermostat pocket Brazed construction Combined thermostat and safety cut-out Element rating 3kW at 240V A/C Expansion vessel (Ultrasteel cylinders only) 120 & 150 litre units 12 litre vessel 180, 210 and 250 litre units 19 litre vessel 300 litre unit 24 litre vessel Pressure and temperature limits of control settings Ultrasteel Plus Ultrasteel Pressure reducing valve 3 bar 3 bar Expansion relief valve 8 bar 6 bar Pressure and temperature relief valve 10 bar / 90 C 7 bar / 90 C High limit thermostat - in dual thermostat 85 C 85 C High limit thermostat - in immersion heater 85 C 85 C Minimum supply pressure 1 bar 1 bar Minimum flow rate supply 25 litres/min 25 litres/min Maximum supply pressure 12 bar 12 bar Quality systems We are a BSi registered company, whose manufacturing sites are licensed to British Standards quality assurance BE EN ISO 9001: 2008. This means all our manufacturing plants are monitored by independent inspectors and our quality systems meet the stringent requirements needed to achieve this standard. Guarantee * The Ultrasteel and Ultrasteel Plus stainless steel inner vessel carries a 25-year guarantee against faulty materials or manufacture. All parts supplied with the cylinder carry a 2-year guarantee. All guarantees must be register at www.kingspanenviro.com/ guarantee or by compleating the guarantee card within the installation manual. * or full guarantee Terms & Conditions, please refer to the Guarantee Card within the installation manual. 15

Wakefield Office Tadman Street, Wakefield, West Yorkshire, W1 5QU Tel.: 0345 260 0258 ax: 0345 260 0259 hotwater@kingspan.com www.kingspanenviro.com KingspanHWSystems TheKingspanEnv @kingspanenviro We take every care and precaution to ensure that information in this document is accurate at the point of publish but with continuous product development the details given in this document are subject to alteration without notice. RE: 024552 Kingspan Albion - Ultrasteel - English - March 2016