Starting current with soft starter Fuse protection

Similar documents
Starting current with soft starter Fuse protection. Heat source connection

Starting current with soft starter Fuse protection

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

Dimplex High efficiency air-to-water heat pump for indoor installation. (Low temperature) Order reference

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels

PRODUCT DATA SHEETS HEAT PUMPS

Product Range Overview 2010

Product Range. Overview 2015.

WARMTEPOMPEN DIMPLEX. POMPES À CHALEUR DIMPLEX.

For a future without oil and gas.

WZS 82(H)(K)3M 20 I B0W I I I (263) (288) 7.0

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Technical data LA 60TUR+

Advance Split

BWL air heat pumps BWS brine heat pumps

Technical data LA 60TU

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Technical data LA 9S-TU

A w rld of new product innovation new product launches

LZT High efficiency air to water heat pumps with E.V.I. compressors

VIESMANN. VITOCAL Air/water heat pumps. Technical guide. VITOCAL 300-A Type AWC-I and AW-O. VITOCAL 350-A Type AWH-I and AWH-O

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Technical data LA 28TBS

LZA High efficiency air to water heat pumps with HP compressor

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

VIESMANN VITOCAL 300-G Brine/water and water/water heat pump Single and two-stage, from 21 kw

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Planning guide. (2010/09) en

WZH Ground source heat pumps

HIGH-POWER HEAT PUMPS. Up to 300 kw

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

Oilon Ground Source Heat Pumps

Do you want a versatile solution

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

Air / Water Heat Pump - Compact Design Modulating 8 18 kw

MODEL LA 6 MI LA 9 MI LA 12 MI LA 16 MI. Heat output (kw)/cop at A-15/W35 5.9/ / / /2.33

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

WPM 2006 plus WPM 2006 R WPM 2007 plus WPM 2007 R

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

NABILATON PRO. The Nabilaton Pro heat pumps consist of MDV brand outdoor units and suitable hydraulic modules from Nabilaton.

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

ECOFOREST GEOTERMIA. ecogeo. Ground/Air Source Heat Pumps.

Product Line Introduction. Karl Zhang Technical support engineer

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

Outline principle. Application Houses with water-borne heating systems. Alternative Select the desired configuration by highlighting the boxes below.

Outdoor Reset Control Theory FULL versus PARTIAL reset

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

Heating Controller SDC Remote Heating Controller DHC

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Type summary Albatros 2

CRIMSON & CRIMSON MAX

Heating Controller SDC Remote Heating Controller DHC

WHA WHA. Ground source heat pumps OTHER VERSIONS ACCESSORIES

HT V2 HT Split

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

ALFÉA EXCELLIA DUO. more. less AIR TO WATER HEAT PUMP

LZT High efficiency air to water heat pumps with E.V.I. compressors

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

Efficient heating that won t cost the earth

REMKO HYBRID HEAT PUMPS

prestige Control Application Supplement - TriMax

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Press. Heat pumps from Viessmann: efficient heat generation with renewable energy and electricity

SHERPA. Air-water split heat pump. COP > 4 ACS a 60 C

prestige Control Application Supplement - TriMax

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

A2/W35: 8.6kW, Power consumption: 2.39kW, COP 3,6. A2/W35: 10.1kW, Power consumption: 2,8kW, COP 3,6

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

Technical specifications

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Technical data. Danfoss DHP-L

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

HIWARM COMPACT kw

Heating with airborne and geothermal heat

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

High temperature air-to-water heat pumps

PROJECT PLANNING AND INSTALLATION MANUAL

KEMPER ThermoSystem. For further information on KTS use the QR code!

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M.

VIESMANN. Installation and service instructions VITOCAL 300-G. for contractors

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

HEAT PUMPS EN - flyer 10/p/2017 Made in Poland

Technical description. Atec.

Transcription:

Data sheet SI 14ME Brine-to-water heat pump Max. flow temperature: 58 C Casing colour: White (similar to RAL 9003) Brown-red design screen (RAL 3011) Heat pump for heating purposes for indoor installation with integrated WPM 2007 plus controller. The control panel is integrated into a brown-red design screen and can also be used as wired remote control using the wall mounting set (special accessories MS PGD). Variable connection options for brine and heating connections on the back board of the casing. Sound-optimised through insulated metal casing and double vibration-isolated compressor. Economiser for high coefficients of performance (COP). Universal design with optional domestic hot water preparation and flexible expansion possibilities for: - Bivalent or bivalent-renewable operating mode - Distribution systems with unmixed and mixed heating circuits Integrated soft starter and load contactor for brine circulating pump, integrated flow and return sensors; external sensor (standard NTC-2) and dirt filter for brine circuit included in the scope of supply. Dirt trap for installation in the brine circuit (return to the heat pump) included in the scope of supply. Technical data Dimplex Brine-to-water heat pump (Low temperature) Order reference SI 14ME Heat pump code 4001 Casing colour White (similar to RAL 9003) Max. flow temperature 58 C Lower operating limit heat source (heating operation) / Upper operating limit heat source (heating operation) -5 to 25 C Heat output at B0/W35 / COP B0/W35* 15,60 kw / 4,07 / COP B0/W45 15,20 kw / 3,20 minal power consumption according to EN 14511 at B0/W35 3,83 kw Sound power level device 52 db (A) Refrigerant / Amount of refrigerant R407C / 2,2 kg Max. heating water flow rate / Pressure drop 2,7 m³/h / 20500 Pa Heat source flow (min.) 3,6 m³/h Dimensions (W x H x D)** 650 x 805 x 462 mm Weight 130 kg Rated voltage 1/N/PE ~230 V, 50 Hz Starting current with soft starter 45 A Fuse protection C 32 A Connection heating 1 ¼ inch Heat source connection 1 ¼ inch Seal of approval MCS (valid until) Seal of approval NF-PAC (valid until) / 30.06.2016 *Heat output and COP according to EN 14511 **Please note that additional space is required for pipe connections, operation and maintenance. Page 1/6

System accessories SI 14ME Description Heat pumps Order ref. Article number Brine-to-water heat pump SI 14ME 353050 1 Elasticated sound insulation underlay strips SYL 250 352260 DN 32 double-sphere rubber expansion joint KOMP 32 362060 DN 32 dirt trap SMF 32 362140 Heat source accessories Sample Brine circuit accessory package for SI 6-14TU SZB 140E 362090 Brine circuit manifold connection package AP SVT 348900 1 Brine circuit manifold (2-fold) with clamping ring fittings SVT 200KV 363860 Brine circuit manifold (3-fold) with clamping ring fittings SVT 300KV 363870 2 Brine circuit manifold (4-fold) with clamping ring fittings SVT 400KV 363880 Antifreeze for the brine circuit 20 l AFN 825 328610 5 Hydraulic accessories Built-under buffer tank PSP 100E 353360 1 Immersion heater 4.5 kw; ~230 V CTHK 630 363610 1 Immersion heater 2.0 kw; ~230 V CTHK 631 336180 Free-standing buffer tank 100 l* PSW 100 351090 Free-standing buffer tank 200 l* PSW 200 339830 Universal buffer tank (500 l)* PSW 500 339210 Dual differential pressureless manifold DDV 25 358390 1 Electronically controlled circulating pump with coupling relay UPH 60-25 367870 Electronically controlled circulating pump with coupling relay UPH 70-25P 367830 1 Manifold bar VTB 25 339870 Manifold bar (3-fold) for modules DN 25 and DN 32 VTB 32 367770 Domestic hot water module/unmixed heating circuit module WWM 25 346600 1 Mixed heating circuit module with temperature sensor MMH 25 348640 Electronically regulated wet running pump (0-10 V) with coupling relay UPE 70-25 362790 1 Electronically regulated wet running pump (0-10 V) with coupling relay UPE 80-25 362810 Ready-for-use DN 32 stainless steel Wellflex pipe VSE 32-50 362520 Ready-for-use DN 32 stainless steel Wellflex pipe VSE 32-100 362530 Ready-for-use DN 32 stainless steel Wellflex pipe VSE 32-150 362540 Ready-for-use DN 32 stainless steel Wellflex pipe VSE 32-200 362550 Ready-for-use DN 32 stainless steel Wellflex pipe VSE 32-300 362560 Immersion heater pipe assembly* HDLR 450 337450 3 kw pipe heater HCT 300 351210 Heating accessories Fan convectors heating 800 W SRX 080M 359080 Fan convectors heating 1200 W SRX 120M 359090 Fan convectors heating 1400 W SRX 140M 359100 Fan convectors heating 1800 W SRX 180M 359110 DHW preparation accessories Domestic hot water cylinder (400 l) with temperature sensor WWSP 880 337880 1 FLH 25M flange heater FLH 25M 349430 1 Safety valve combination SVK 852 326660 Design domestic hot water cylinder with sheet metal coverings and temperature sensor* WWSP 442E 353370 500 l solar cylinder for heat pump WWSP 540 SOL 361090 PWS 650 combination tank* PWS 650 367660 Combo tank for heating and domestic hot water preparation with central flow* PWD 750 349100 Combo tank for heating and domestic hot water preparation with central flow* PWD 900 362860 Pump unit DN 25 for direct connection of the domestic hot water cylinder WPG 25 356030 1 Electronically controlled circulating pump with coupling relay UPH 60-25 367870 1 FWS WT fresh water station FWS WT 368100 Control accessories Extension for an Ethernet network connection NWPM 356960 item Item Price Page 2/6

System accessories SI 14ME Description Order ref. Article number Extension for a KNX/EIB bus connection EWPM 356970 Extension for a Modbus connection LWPM 410 339410 Interface card for HPM for connection of Smart RTC and WPM Econ PK/PKS 14/25 Econ RWPM 363370 Swimming pool/remote fault indicator relay module RBG WPM 339700 MS PGD wall mounting kit MS PGD 353810 Remote control for WPM 2006/2007/EconPlus/R* AP PGD 356570 Outside temperature sensor with casing FG 3115 336620 Temperature sensor NTC-10 with metal sleeve NTC-10M 363600 Thermostat for heating and domestic hot water KRRV 003 322070 Accessories for passive cooling Passive cooling station with cooling module* PKS 14 Econ 362930 Three-way distribution valve DWU 25 347760 Three-way distribution valve DWU 40 347770 Plate heat exchanger, copper-soldered WTU 50 362370 Control accessories (cooling) Interface card for HPM for connection of Smart RTC and WPM Econ PK/PKS 14/25 Econ RWPM 363370 Passive cooling controller* WPM Econ PK 360000 Room climate station for temperature and humidity measurement RKS WPM 342220 Room temperature controller heating/cooling* RTK 601U 355610 Room temperature controller heating/cooling RTK 602U 355620 Dew point monitor* TPW WPM 350970 * Other specific accessories available / required Sample tes: The heat source accessories are designed for ground heat collectors according to the project planning documentation. Important information: The combination of the components and the quantities indicated represent a non-binding sample system, which needs to be tested and individually adapted as required. Pump dimensioning must be reviewed according to the pressure loss of the system and the minimum heating water flow rate of the heat pump. item Item Price Page 3/6

Brine-to-water heat pump, Integration Diagram, Heat pump and immersion heater te: The given hydraulic integration schematic is a schematic representation of the key components and serves as an aid for planning your customized system. The current status is available at all times under www.dimplex.de/nc/en/professional/onli ne-planner/hydraulic-integrations.html. It does not contain all the required safety devices, the components needed to maintain constant pressure, or any other additional valves which may be required for maintenance and service work as stipulated by EN 12828. The heat pump manager settings and any external regulation system which may be connected must be adapted to the present integration diagram. Software updates may be required! Page 4/6 Integration Diagram: 20231020

Brine-to-water heat pump, Integration Diagram, Heat pump and immersion heater System description: Every brine circuit should be provided with a shutoff valve for ventilation purposes. Brine circuits must all be of the same length in order to ensure that each has an equal flow and abstraction capacity. The filling and breather mechanisms should be installed at the highest point. A buffer tank connected in series is recommended for heat pump heating systems, to ensure the minimum heat pump runtime of 6 minutes for all operating statuses. The heat pump supplies a large part of the required heat output. An electric heating element (immersion heater) supplements the heat pump on days when the external temperature lies below the bivalence point. In mono energy systems, the contactor for the immersion heater (E10.1) must be set according to the output. It is controlled (230 V AC) by the heat pump manager via terminals X1/N and J13/NO4. The heat exchanger in the hot water cylinder must transfer the maximum heat output at the maximum heat source temperature. In systems with high hot water consumption (multiple dwellings, industrial applications) the cylinder must be set to the maximum peak demand while taking the shut-off times into account. The maximum heat output and the maximum heating water flow must be adhered to! The contactor for the flange heater (E9) in the hot water cylinder should be dimensioned according to the output and must be supplied by the customer. It is controlled (230 V AC) by the heat pump manager via terminals X1/N and J16/NO10. The maximum heat output of the heat pump and the water flow are to be observed. The dual differential pressureless manifold ensures that the required minimum water flow rate is maintained, independent of both the number of open heating circuits and of how the system is used. Hydraulic isolation is carried out using two connections between flow and return; each connection is fitted with a check valve. The characteristic curve of the pump in the consumer circuit must be set in such a way that a maximum spread of 10 Kelvin is not exceeded, in order to prevent unnecessary surging of the heat pump. Electronically regulated pumps must be operated at a constant pressure. Presettings: Pre-configuration Operating mode Heating circuit 1 Heating circuit 2 Passive cooling function DHW preparation DHW preparation request by Domestic hot water preparation flange heater Swimming pool water preparation Low pressure brine - measurement present Low-pressure brine Setting Mono energy Sensor Display Page 5/6 Integration Diagram: 20231020

Brine-to-water heat pump, Integration Diagram, Heat pump and immersion heater Legend: 1. Heat Pump 1.1 Air-to-water heat pump 1.2 Brine-to-water heat pump 1.3 Water-to-water heat pump 1.4 Reversible air-to-water heat pump 1.5 Reversible brine-to-water heat pump 1.6 Reversible water-to-water heat pump 1.7 Air-to-water heat pump split design 2. Heat pump manager 3. Parallel buffer tank 3.1 Buffer tank 4. Hot water cylinder 5. Swimming pool heat exchanger 6. Passive cooling station with cooling controller N6 7. Heating and silent or dynamic cooling 8. Fan convector with 4-wire connection 9. Cooling circuit only 10. Heating circuit only 13. Heat source 15. Hydraulic tower 16. Scalding protection 17. Hydro tower HWK 332 Domestic hot water distribution system: DDV 25 DDV 32 EB KPV KPV 25 MMB 25 MMH 25 VTB 25 WWM 25 Dual differential pressureless manifold (up to 2.0 m³/h)* Dual differential pressureless manifold (up to 2.5 m³/h)* Extension module for compact manifold (up to 2.0 m³/h)* Compact manifold with overflow valve (up to 1.3 m³/h)* In combination with EB KPV (up to 2.0 m³/h)* Mixer module, bivalent (up to 2.0 m³/h)* Mixer module for heating circuit Manifold bar (up to 2.5 m³/h)* Hot water module / unmixed heating circuit (up to 2.5 m³/h)* * Recommended max. heating waterflow Solarthermics: SST 25 Solar station for hot water SOLK 1204 Collector field SOLPU 1 Solar station SOLCU 1 Solar controller SOLCU 2 Solar controller T1 Temperature sensor (collector sensor) T2 Temperature sensor (cylinder 1) T3 Temperature sensor (cylinder 2 /optional display function) B3 Hot water thermostat B4 Swimming pool thermostat B7 Thermostat primary circuit E9 Flange heater, hot water E10 2nd heat generator (HG2) E10.1 Immersion heater E10.2 Oil/gas boiler E10.3 Solid fuel boiler E10.5 Solar energy system F7 Safety temperature monitor F10 Flow rate switch K20 Contactor for 2nd heat generator K21 Contactor for immersion heater hot water M11 Primary pump for heating operation M12 Primary pump for cooling operation M13 Heat circulating pump for main circuit M14 Heat circulating pump for heating circuit 1 M15 Heat circulating pump for heating circuit 2 M16 Auxiliary circulating pump M17 Cooling circulating pump M18 Hot water circulating pump M19 Swimming pool water circulating pump M20 Heat circulating pump heating /cooling circuit 3 still M21 Mixer M22 Mixer heating/cooling circuit 2 M25 Circulating pump for heating and domestic hot water preparation N1 Heating controller N2 Cooling controller for reversible heat pumps N3/N4 Room climate control stations N6 Cooling controller for passive cooling N12 Solar controller N17.1 Cooling module general N17.2 Cooling module active N17.3 Cooling module passive N17.4 Solar module WPM Econ SOL R1 External wall sensor R2/2.1 Return flow sensor R3 Hot water sensor R4 Return flow sensor for cooling water R5 Temperature sensor for heating circuit 2 R9 Flow sensor (antifreeze) R11 Flow sensor for cooling water R13 Sensor for heating circuit 3 / bivalent-renewable SMF Dirt trap TC Room temperature controller Y5 Three-way distribution valve Y6 Two-way valve Y7 Three-way mixing valve Y8 Three-way valve (closing time max. 10 sec.) Y12 External 4-way reversing valve Y13 Three-way reversing valve Page 6/6 Integration Diagram: 20231020