Broag Pressurisation equipment

Similar documents
PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

Exceeding the Standard

Exceeding the Standard

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Instructions for Use Installation and Servicing

ZIP AquaFlo II. Models: Direct, Indirect and Solar Compatible. Unvented cylinder water heaters

Cylinders for Domestic Purposes Heat Pumps

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

Why Vaillant? Because the ecotec delivers day in, day out. Vaillant ecotec boiler range. The TECHNICAL Brochure

Series 1000 & Storage Water Heaters

Breeze extended to include Variable Speed Drives Breeze range extended to include Steam Primary

Technical and Installation manual All Models

ADVANCE ELECTRIC THERMAL STORE

Re n ewa b l e s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

Hydraulic Installation

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

2015 PRODUCT RANGE GUIDE

XCEL HEAT BANKS Installation Instructions. Thermal Integration Ltd., 1-3 Wealdstone Road, Sutton, Surrey SM3 9QN.

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

CI/SfB. (53.3) x. October Unvented Water Heaters. PremierPlus. Unvented Hot Water Cylinders

SEALED THERMAL STORE

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Direct, Indirect & Solar Un-Plumbed & Pre-Plumbed Unvented Cylinder Installation & Maintenance Manual

Commercial Hot Water Solutions Ltd.

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

Alpha CombiMax 350 and 600

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

Commercial Indirect / Multi Energy / Solar Unvented Water Heaters Installation & Maintenance Manual

THERMAL STORE MAINS PRESSURE SYSTEM

PremierPlus. and PremierPlus SystemFit. Direct and Indirect Unvented Water Heating. Unvented Water Heaters

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Instructions & Maintenance

the electric heating company ELECTRIC BOILER HANDBOOK

ELECTRIC BOILERS. RANGE 1kW to 980kW ABOUT ATLANTIC ELECTRIC DOMESTIC HOT WATER HEATERS. WATER HEATERS 445 to 7520ltrs/hr

Schuco SS-TC/SC Cylinders

H o t Wa te r Syste m s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

unistor High performance unvented stainless steel cylinder range

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

Precision Storage Vessels ELECTRIC WATER HEATERS

MEGAFLO HE Iss 1

extreme HIGH EFFICIENCY HOT WATER SYSTEMS

Installation, operating and servicing instructions

Direct, Indirect, Solar & Heat Pump Un-Plumbed & Pre-Plumbed Unvented Cylinder Installation & Maintenance Manual

Installation Manual EXCELSIOR Unvented Water Heater

Cylinder Manual. Open Vented Cylinders Stainless Steel Water Heaters. Twin Coil TW180V TW210V TW250V TW300V Triple Coil TR250V TR300V

Advance Stainless Steel Unvented Hot Water Cylinders for Heat Pump Systems. Installation and Commissioning Manual

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options

1 Dimensions Installation Mains/boosted cold water inlet Connection to the system Drain Dimension for fixing 6

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

PROPAK THERMAL. Packaged Plate Heat Exchanger

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Hamworthy. Powerstock. Calorifiers and Storage Tanks Single and Twin Coils Capacities 160 litres to 995 litres

Unvented water heating

WATER HEATERS INSTALLATION MANUAL

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

Installation and Commissioning Manual

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for vented systems.

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013

Unvented Water Heating. Zircon

Unvented Hot Water Systems for the Professionals

unistor High performance unvented stainless steel cylinder range

Stored Water District Heating Interface Units. Heat Interface Units

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

Megaflo Eco Plus Unvented Indirect Hot Water Cylinders 800L L

Powerstock Storage Tank

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

Design, Installation, User & Servicing Instructions

Water Heating Systems

Slide 1 Jul 20, 2006 Viessmann UK

A Guide to Commercial Hot Water from Hamworthy. Introducing Hamworthy s Product Ranges for Hot Water Generation:

Indirect Fired Water Heater

FASTflo. Working towards a cleaner future

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

Pressurisation units & expansion vessels

H o t Wa te r Syste m s. Unvented Copper Hot Water Cylinders for Heat Pump and Solar Input. Exceeding the Standard

ADVANCE ECB ELECTRIC COMBINATION BOILER

Plus. USER and INSTALLATION INSTRUCTIONS. 30,000-9kW for Heating and Hot Water

Experienced. Flexible. Reliable. Approachable. Genuine

EXCELLENCE IN HOT WATER TECHNOLOGY CYLINDER PRODUCT GUIDE

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

Installation and User Instructions HS10U, HS15U.

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

heat interface units A BOILER WITHOUT A FLAME

Stainless Steel Unvented Cylinders

Transcription:

Broag Pressurisation equipment Compact wall mounted and free standing pressurisation units, utilising the latest microprocessor control. For use on sealed heating and cooling systems, offering accurate control and reliability. Digital equipment comes with a 4 digit bright LED display with scrolling messages including pump operation and alarm modes. Single or twin pump configurations. Complete with integral water break tank utilising an AB airgap and a WRAS approved float valve. Twin pump equipment operates as cyclic duty standby with automatic changeover. Internal alarm with mute function. Security password protected. Auto resetting low water detection, for pump protection. Auto resetting high and low pressure alarm. Digital pressure setpoint with adjustable differential. Flood protection through a pump run limit timer. Normally closed, common fault, volt free contact (Boiler interlock). Normally open, individual volt free contacts for pump trip, high pressure, low pressure and sensor health. All volt free contacts are rated for use with electrical supplies up to 30v with a maximum current draw of 5 amps. RS 485 Connectivity Hours run counter (per pump) month service reminder Excessive start alarm (>3 times in 8 hours) Pump pulse option ( second pulse per pump if inactive for 60 days) Fill system option (Not available on 3OD/3OD)

Broag Pressurisation equipment

3

Using Maximum e Remtank Unvented Cylinders supplied with kits o Water at 0 C expands approx. 0.5% o Water at 60 C expands approx..7% Using a safety factor of 5% water expands between o o 0 C and 60 C @.5% Using the vessel efficiency calculated as above = 4.8% 000 Ltr x.5% = 5 Ltr expansion; 5 / 4.8% = 35 ( vessel) 800 Ltr x.5% = Ltr expansion; / 4.8% = 8 ( vessel) 500 Ltr x.5% = 7.5 Ltr expansion; 7.5 / 4.8% = 7.5 (4 Ltr vessel) (NOTE: The above sizing relates to Cylinder water content ONLY. Any additional system expansion should be calculated independently.) 4

5

. Flexcon floor standing digital flexfiller.. Flexcon Uni-fil filling set. (Must be disconnected after filling system). 3. Flexcon expansion vessel sited on heating system return. 4. Flexvent Super automatic air vent-mounted vertically where air naturally collects. 5. PS Vessel (Intermediate for heating) or (Buffer for chilled systems). 6. Safety valve and tundish sited on top or above the Boiler or plant. 7. Flamcovent clean de-aerator - in flow from the boiler before the pump. 8. Supastor indirect calorifier. 9. PSD pressure step degasser. 6

Remtank SS Direct unvented cylinders Direct unvented cylinders for potable water installations Fluid Flow Sequence Mains Water Isolation Valve (Not Supplied) 3 bar Pressure Reducing Valve Safety Group ( Expansion Relief Valve c/w Non Return Valve) Drain Valve (Not Supplied) Stainless Supastor Hot Water Calorifier 0-500 Connection 800-000 (Floor Standing Model) off 3kW 30v/50Hz Immersion Heater Pressure Reducing Valve Pre-Set Selection Guide Property Type Bedsit / beds with bath / shower 3 beds with bath / shower 4 beds with bath / shower /3 beds with baths / showers 4/5 beds with baths / showers Sports club, Restaurant etc. Hotels, Schools etc Safety Group c/w Non Return Valve Relief Direct Size 0 50 or 80 80 or 0 0 0 or 50 300 or 500 800 or 000 Tundish Combined Temperature & Pressure Relief Valve Factory Fitted / 95 o C *In areas with a high concentration of Chlorine (00 ppm or above) additional protection of the cylinder is required with an electronic anode. This is an optional extra and is not reflected in the pricing. Vessels Direct vessels can be supplied without kits as a storage vessel Technical Specification Direct (including Kit) Volume (Nominal) 0 litres 50 litres 80 litres 0 litres 50 litres 300 litres 500 litres 800 litres 000 litres Direct Height (mm) Diameter (mm) Weight (Dry kg) Weight (Normal Full kg) T&P Tapping T&P Pressure Setting T&P Temperature Setting Expansion Relief Setting Electrical Heater Quantity Electrical Heater Rating (Each) Re-heat Times (x) Heat Up Times (From Cold) 977 0.8 4 34 mins 40 mins 67 3.5 74 46 mins 65 mins 347 6.5 07 56 mins 80 mins 569 33 43 69 mins 98 mins 759 35.5 86 80 mins 4 mins Insulation is interlocked polystyrene to allow for inspection of cylinder if required. 750 606 4 34 0 mins 44 mins 83 734 59 559 59 mins 56 mins 50 Ltr 960 00 900 60 mins 400 mins 80 Ltr 360 5 5 38 mins mins 80 Ltr N.B. The expansion vessel provided is sized to accommodate a total hot water system volume of.5 times the calorifier size. It is the responsibility of the installer to verify that this vessel size is appropriate for the installation and add additional vessels if required. 7

Remtank SS Direct unvented cylinders Secondary Flow (0-300) (500-000) 0 to 300 litre 500 to 000 litre Technical Specification Connections Volume (Nominal) Height A (mm) Diameter B (mm) Cold Water C (mm) Cold Water Connection Immersion D (mm) T&P Valve J (mm) Immersion K (mm) DHW Flow J DHW Connection 0 litres 50 litres 80 litres 0 litres 50 litres 300 litres 500 litres Direct Direct Direct Direct Direct Direct Direct 977 89 749 644 67 89 939 834 347 89 9 04 569 89 34 36 759 89 53 46 750 606 47 8 53 444 83 734 5 37 7 93 7 800 litres 000 litres Direct Direct 960 360 338 338 / BSP (M) / BSP (M) 343 343 603 003 03 03 603 003 / BSP (M) / BSP (M) 8

Remtank SS unvented cylinders unvented cylinders for potable water installations Fluid Flow Sequence Mains Water Isolation Valve (Not Supplied) 3 bar Pressure Reducing Valve Safety Group ( Expansion Relief Valve c/w Non Return Valve) Drain Valve (Not Supplied) Stainless Supastor Hot Water Calorifier 0-500 Connection 800-000 (Floor Standing Model) Port Valve For Use With The IMIT Thermostat Controlling The Primary Flow (Boiler) Water To The Coil 3kW 30v/50Hz Immersion Heater Pressure Reducing Valve Pre-Set Selection Guide Safety Group c/w Non Return Valve Relief Property Type Bedsit / beds with bath / shower 3 beds with bath / shower 4 beds with bath / shower /3 beds with baths / showers 4/5 beds with baths / showers Sports club, Restaurant etc. Hotels, Schools etc Size 0 50 or 80 80 or 0 0 0 or 50 300 or 500 800 or 000 Tundish Technical Specification (including Kit) Combined Temperature & Pressure Relief Valve / 95 o C *In areas with a high concentration of Chlorine (00 ppm or above) additional protection of the cylinder is required with an electronic anode. This is an optional extra and is not reflected in the pricing. IMIT Combined Thermostat & Safety Relay Volume (Nominal) 0 litres 50 litres 80 litres 0 litres 50 litres 300 litres 500 litres 800 litres 000 litres Height (mm) Diameter (mm) Weight (Dry kg) Weight (Normal Full kg) T&P Tapping T&P Pressure Setting T&P Temperature Setting Expansion Relief Setting Electrical Heater Quantity Electrical Heater Rating (Each) Re-heat Times (8º Supply) Heat Up Times (From Cold) Max.Primary Pressure (Coil) Primary Flow Rate (Boiler L/min) Primary Resistance (mbar) Continuous Output (mbar) Coil Rating kw 976 3 43 7 mins 9 mins 5 64.9 464 4.7 67 7 77 0 mins 3 mins 34 4.9 493 6. 347 30 0 5 mins 37 mins 34 4.930 493 6. 569 38 48 mins 7 mins 4 34.8 67 33.4 759 4 9 4 mins 30 mins 4 354.6 684 36.4 750 606 50 350 8 mins 35 mins 4 50 985 5.4 83 734 68.5 569 3 mins 38 mins 67 509.8 059 56.4 50 Ltr 960 0.5 9 3 mins 40 mins 9 87.0 695 90. 80 Ltr 360 4.5 45 40 mins 49 mins 9 87.0 695 90. 80 Ltr Insulation is interlocked polystyrene to allow for inspection of cylinder if required. N.B. The expansion vessel provided is sized to accommodate a total hot water system volume of.5 times the calorifier size. It is the responsibility of the installer to verify that this vessel size is appropriate for the installation and add additional vessels if required. 9

Remtank SS unvented cylinders unvented cylinders for potable water installations Secondary Flow (0-300) (500-000) 0 to 300 litre 500 litre 800 to 000 litre Technical Specification Connections Volume (Nominal) Height A (mm) Diameter B (mm) Cold Water C (mm) Cold Water Connection Immersion D (mm) Primary Flow F (mm) Primary Return E (mm) Primary Connection DHW Return G (mm) Secondary Return Connection (mm) Thermostat H (mm) T&P Valve J (mm) Immersion K (mm) DHW Flow J DHW Connection 0 litres 976 49 379 8 BSP (F) 67 749 50 litres 67 49 379 8 BSP (F) 7 939 80 litres 347 49 379 8 BSP (F) 845 9 0 litres 569 49 554 634 BSP (F) 984 34 50 litres 759 49 579 659 BSP (F) 08 53 300 litres 750 606 47 4 47 7 80 BSP (F) 5 53 500 litres 83 734 5 93 3 83 4 BSP (F) 95 7 7 800 litres 960 50./ BSP (M) 343 338 038 000 litres 360 338./ BSP (M) 343 338 038 38 38./ BSP (F)./ BSP (F) 03 03 603 03 03 03 603 003./ BSP (M)./ BSP (M) 0

Remtank SS Solar unvented cylinders Solar unvented cylinders for potable water installations Fluid Flow Sequence Mains Water Isolation Valve (Not Supplied) 3 bar Pressure Reducing Valve Safety Group ( Expansion Relief Valve c/w Non Return Valve) Drain Valve (Not Supplied) Stainless Supastor Hot Water Calorifier 0-500 Connection 800-000 (Floor Standing Model) Port Valve For Use With The IMIT Thermostat Controlling The Primary Flow (Boiler) Water To The Coil 3kW 30v/50Hz Immersion Heater Pressure Reducing Valve Pre-Set Selection Guide Safety Group c/w Non Return Valve Relief Property Type Bedsit / beds with bath / shower 3 beds with bath / shower 4 beds with bath / shower /3 beds with baths / showers 4/5 beds with baths / showers Sports club, Restaurant etc. Hotels, Schools etc Solar Size 0 50 or 80 80 or 0 0 0 or 50 300 or 500 800 or 000 Tundish Technical Specification SS Solar (including Kit) Combined Temperature & Pressure Relief Valve Factory Fitted / 95 o C *In areas with a high concentration of Chlorine (00 ppm or above) additional protection of the cylinder is required with an electronic anode. This is an optional extra and is not reflected in the pricing. Volume (Nominal) 0 litres 50 litres 300 litres 500 litres 800 litres 000 litres IMIT Combined Thermostat & Safety Relay Supastor Solar Height (mm) Diameter (mm) Weight (Dry kg) Weight (Normal Full kg) T&P Tapping T&P Pressure Setting T&P Temperature Setting Expansion Relief Setting Electrical Heater Quantity Electrical Heater Rating (Each) Primary Re-heat Times (8º Supply) Primary Heat Up Times (From Cold) Max.Primary Pressure (Coil) Primary Flow Rate (Boiler L/M) Primary Resistance (mbar) Primary Continuous Output (mbar) Primary Coil Rating KW 568 43 53 mins 7 mins 4 34.8 67 33.4 754 46 96 4 mins 30 mins 4 354.6 684 36.4 750 606 55 355 8 mins 35 mins 4 50 985 5.4 83 734 75.5 576 3 mins 38 mins 67 509.8 059 56.4 50 Ltr 960.9 93.4 3 mins 40 mins 9 87.0 695 90. 80 Ltr 360 36.9 57.4 40 mins 49 mins 9 87.0 64 87.4 80 Ltr Insulation is interlocked polystyrene to allow for inspection of cylinder if required. N.B. The expansion vessel provided is sized to accommodate a total hot water system volume of.5 times the calorifier size. It is the responsibility of the installer to verify that this vessel size is appropriate for the installation and add additional vessels if required.

Remtank SS Solar unvented cylinders Solar unvented cylinders for potable water installations Secondary Flow (0-300) (500-000) 0 to 300 litre 500 litre 800 to 000 litre Technical Specification Connections Volume (Nominal) Height A (mm) Diameter B (mm) Cold Water C (mm) Cold Water Connection Immersion D (mm) Primary Flow F (mm) Primary Return E (mm) Primary Connection DHW Return G (mm) DHW Return Connection (mm) Thermostat H (mm) T&P Valve J (mm) Immersion K (mm) DHW Flow J (mm) DHW Connection Solar Return L (mm) Solar Flow J (mm) Secondary Connection Thermostat Primary Coil Pocket (mm) 0 litres Solar 50 litres Solar 300 litres Solar 568 754 750 606 47 88 379 834 379 7 47 37 634 BSP (F) 6 34 659 BSP (F) 08 53 774 BSP (F) 5 53 098 34 89 88 53 89 07 774 8 500 litres Solar 800 litres Solar 83 960 734 5 338./ BSP (M) 93 343 3 338 83 038 95 38 BSP (F) BSP (F) 95 03 7 603 03 7 603./ BSP (M) 077 93 437 603 558 03 000 litres Solar 360 338./ BSP (M) 343 338 038 38 BSP (F) 03 03 03 003./ BSP (M) 443 853 03

Wiring details for all Digital Pressurisation Units Supply Voltage 30- v- Single Phase. Fuse Rating - 5 Amps Max Full Load Current - 4.5 Amps Under normal operation there is a permanent live feed back to the boiler, the water temperature is regulated by the operation of the motorised valve feeding the internal coil. To control the heating times, connect the electrical feed to the thermostat from the program or time clock (L). When the Remtank Calorifier is at the desired temperature, the motorised valve will close and the boiler, itself, will register no demand from the cylinder and shut down if appropriate. Note: Control of hot water via Rematic 945ck and Broag Priority Kits. When using the Rematic 945ck controller and Broag Priority Kits in conjunction with the supplied HWS immersion sensor, fit the supplied brass pocket in the secondary return connection and connect immersion sensor into pocket, the secondary return connection should then be connected into the cold feed supply at the base of the calorifier between the safety group and the calorifier. Sensor wiring connections can be found in the boiler control wiring details. The port valve must be wired as detailed in the diagrams above, with the electrical supply coming from the Priority Kit/Boiler controls. To ensure the correct operation of the Priority Kit set the control thermostat (connected to the port valve) 0 o C higher than the boiler or controller hot water temperature. 3

Assembly for Direct, and Solar 6 5 4 3 Hot Water Outlet D 400mm Maximum Length D C Secondary Return (Anode Connection) C Drain Valve (Not Supplied) T&P Tundish B 400mm Minimum Length B A Pressure Reducing Valve Cold Water Inlet 6 Safety Group 00mm Minimum Length 5 To Drain NOTE: The location of the Pressure Reducing Valve,, Safety Group and Drain Valve is flexible, as long as the distances shown and written instructions are followed. This clause allows the Expasnion Vessel to be located above the Hot Water Calorifer / Cylinder. 4 Designed by Checked by Approved by Date Date RJAC MC RJAC 5/05/006 0/0/006 3 50mm Minimum Length Stainless Supastor Direct Assembly To Drain Appendix 4 Edition Sheet / A 6 5 4 3 Hot Water Outlet D 400mm Maximum Length D Secondary Return (Anode Connection) C Drain Valve (Not Supplied) T&P Tundish C Primary Flow (Boiler) B 400mm Minimum Length B Safety Group To Drain 50mm Minimum Length A Pressure Reducing Valve Cold Water Inlet 6 00mm Minimum Length 5 Primary Return (Boiler) NOTE: The location of the Pressure Reducing Valve,, Safety Group and Drain Valve is flexible, as long as the distances shown and written instructions are followed. This clause allows the Expasnion Vessel to be located above the Hot Water Calorifer / Cylinder. 4 Designed by Checked by Approved by Date Date RJAC MC RJAC 5/05/006 0/0/006 3 Stainless Supastor and Solar Assembly To Drain Appendix 3 Edition Sheet / A 4

Issue date: 30 0 008 Ed/66/xx/xxxx