TYPE APPROVAL CERTIFICATE

Similar documents
Easy installation Certified for zones 1 and 21 High IP degree of protection

EU RO MUTUAL RECOGNITION TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

IECEx Certificate of Conformity

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

Fixed Gas Detection System/Meridian CERTIFICATION

HYUNDAI HEAVY INDUSTRIES CO., LTD.

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

INSTRUCTION MANUAL (ATEX / IECEx)

Issued to DISTRIBUIDORA INTERNACIONAL CARMEN, S.A -DICSA- Zaragoza Zaragoza, Spain

Integrated Solutions Low Voltage Systems

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

NexLED. Ex e LED BULKHEAD. Features. Standard Specification. International Approvals. NexLED with Exit Sign kit

UL HAZARDOUS LOCATIONS SERVICES

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

For compliance with Resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority.

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Electrical Installations Design, Selection, Erection and Inspection

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Manual for QX0201 Push Button

INSTRUCTION & SERVICE MANUAL

Flameproof Manual Call Points Series MCP

TYPE APPROVAL CERTIFICATE

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

For compliance with Resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority.

Safety instructions VEGAPULS 64

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

For the compliance with the resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority.

For compliance with Resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority.

INTERNATIONAL ELECTROTECHNICAL COMMISSlON IEC Certification Scheme for Explosive Atmospheres

Illumination unit For sight glass level indicator Model LGI

Certificate of Compliance

Earth-Rite II PLUS Static Earthing System

Manual Power relay SR853

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

TYPE APPROVAL CERTIFICATE

DNVGL-CP-0398 Edition December 2015

Dräger Polytron 8700 IR Detection of flammable gases and vapors

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

Equipment and Solutions

manual addendum DELPHI Ex

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

IECEx Certificate of Conformity

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications

Annubar Flowmeter Series

Intrinsically Safe Solutions

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Dräger Polytron 5100 EC Detection of toxic gases and vapors

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

IECEx Certificate of Conformity

BC9700 series High Power LED Explosion Proof Light

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

Dräger Polytron 8310 IR Detection of flammable gases and vapour

ATEX certificate. Item Model Product Ex-mark/ Date of issue Remark LCIE certificate. Ⅱ2 G Ex dⅡc T6 Gb Ⅱ2 G Ex eqⅡc Gb

Certification Supplement Manual

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Inductive slot sensor

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

Dräger Polytron 8700 IR Detection of flammable gases and vapors

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

Low-voltage switchgear and controlgear - rated voltage does not exceed 1000V AC or 1500V DC

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

INSTRUCTION MANUAL (ATEX / IECEx)

Explosion-proof Immersion Heater Type D-8660

ExPolar Heating System

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

SOUND RECEPTION SYSTEM

POINT STATUS LIGHTS PSL LED HELIDECK STATUS LIGHT SYSTEM SAFE AREA & CLASS I, DIVISION 2 (ZONE 2)

IECEx Certificate of Conformity

Local Control Panels for VG9000H LCP9H Series. Installation, Maintenance and Operating Instructions

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

OPTIBAR DP 7060 Supplementary Instructions

Operating Manual Distribution box

Transcription:

TYPE APPROVAL CERTIFICATE Certificate No: E-14378 This is to certify: That the Pilot Device with type designation(s) Pilot device Issued to BARTEC GmbH BAD MERGENTHEIM, Germany is found to comply with Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore Standards Application : Product(s) approved by this certificate is/are accepted for installation on all vessels classed by DNV GL. This Certificate is valid until 2016-12-31. Issued at Høvik on 2015-10-05 DNV GL local station: Augsburg for DNV GL Approval Engineer: Nicolay Horn Marit Laumann Head of Section This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 1 of 6 DNV GL 2014. DNV GL and the Horizon Graphic are trademarks of DNV GL AS.

Product description I Potentiometer with terminals for rail-mounted installation Type 07-3371-1***/**** Rated insulation 500V Ex protection class: II 2G Ex de IIC / I M2 Ex de I Certification: PTB 05 ATEX 1064U, IECEx PTB 10.0017U II Potentiometer with terminals for panel-mounted installation Type 07-3373-1***/****, 07-3373- 4***/**** Rated insulation 500V Ex protection class: II 2G Ex d e IIC Gb / I M2 Ex d e I Mb Certification: PTB 05 ATEX 1064U, IECEx PTB 10.0017U III Potentiometer with cable for installation on panel (front installation) Type 07-3373-3***/**** Rated insulation 500V / 400 V (standard version) Ex protection class: II 2G Ex d IIC T6 Gb IP protection class: IP67 in conjunction with actuating element Type 05-0003-****/**** Certification: PTB 05 ATEX 1065 X, IECEx PTB 11.0053 X IV Potentiometer for installation on panel (front installation) with cover for connection cable Type 07-3373-5***/**** Rated insulation 500V / 400 V (standard version) Ex protection class: II 2G Ex d IIC T6 Gb IP protection class: IP66 in conjunction with actuating element Type 05-0003-****/**** Certification: PTB 11 ATEX 1010 X, IECEx PTB 11.0025 X Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 2 of 6

V Actuating elements Type 05-0003-00**/**** Ex protection class: Ex II 2G Ex e II, Ex II 2D Ex td A21 IP65, IP66, IP67, T80 o C Ambient Temperature: -55 o C to +70 o C (Zone 1), -20 o C to +70 o C (Zone 21) IP protection class: Up to IP67 Material: Enclosure: Thermoplastic Sealing: EPDM, NRB for increased resistance to oil. Certification: IECEx CLM 14.0005U, CLM 13 ATEX 3010 U, PTB 00 ATEX 3114 U Description of Position selector switch, Double pushbutton actuator, Pushbutton, Mushroom elements: pushbutton, Emergency Stop, Locking mushroom pushbutton, Lock (DOM), Lock (RONIS), Position, Selector switch (BS), Position selector switch, Key switch, Lamp Illuminated button actuator, Potentiometer Actuator, Blanking plug. VI Comex Control stations Type 07-351*-****/****/**** Rated insulation Max 600 / 690 V* Rated Current: Max 16 A PE conductor 4 x 2.5 mm 2 Ex protection class: II 2G Ex ed IIC T6, II 2D Ex td A21 IP65, IP66, IP67, T80 o C (-20 o C to +60 o C for zones 21 and 22) IP protection class: Up to IP66 / IP67 Certification: CLM 14 ATEX 3073X / PTB 00 ATEX 1068 / IECEx CLM 14.0029X * See application limitation VII Control stations Type 07-31**-****/****, 07-3S**-****/**** Rated insulation Max 1000 V* Rated Current: Max 160 A (Gas) max. 125 A (Dust) Type of connections: Terminals 2.5 mm 2 Conductor area: Max. 125 mm 2 Ex protection class: II 2G Ex de ia/ib [ia/ib] mb q IIA, IIB, IIC, T6, T5, T4 Ex td [iad/ibd] A21 IP65, T80 o C, T95 C, T130 C Ambient -55 o C to +80 o C ( -20 o C to +60 o C for zones 21 and 22) IP protection class: Up to IP66 / IP67 Certification: PTB 02 ATEX 1159 / IECEx PTB 10.0043 * See application limitation Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 3 of 6

VIII Illuminated button with terminals for panel-mounted installation Type 07-3361-1***/**** Rated operating voltage: AC 12 V to 250 V (T a +50 o C) DC 12 V to 60 V (T a +50 o C) AC/DC 12 V to 24 V (T a +60 o C) LED: red, green, yellow, white, blue Ex protection class: II 2G Ex d e IIC Gb / I M2 Ex d e I Mb II 2 G Ex d e ia IIC Gb / I M2 Ex d e ia I Mb Ambient Temperature: -55 o C to +50 o C (+60 o C AC/DC 12 to 24 V) Certification: PTB 97 ATEX 1064 U, IECEx PTB 10.0014 U IX Illuminated button with terminals for panel-mounted installation Type 07-3363-1***/****, Type 07-3363-4***/**** Rated operating voltage: AC 12 V to 250 V (T a +50 o C) DC 12 V to 60 V (T a +50 o C) AC/DC 12 V to 24 V (T a +60 o C) LED: red, green, yellow, white, blue Ex protection class: II 2G Ex d e IIC Gb / I M2 Ex d e I Mb II 2 G Ex d e ia IIC Gb / I M2 Ex d e ia I Mb Ambient Temperature: -55 o C to +50 o C (+60 o C AC/DC 12 to 24 V) Certification: PTB 97 ATEX 1064 U, IECEx PTB 10.0014 U X Illuminated button with cable for installation on panel (front installation) Type 07-3363-3***/**** 1) Rated operating voltage: AC 12 V to 250 V (T a +50 o C) DC 12 V to 60 V (T a +50 o C) AC/DC 12 V to 24 V (T a +60 o C) LED: red, green, yellow, white, blue Ex protection class: Ex II 2G Ex d IIC T6 Ambient Temperature: -55 o C to +50 o C (+60 o C AC/DC 12 to 24 V) IP protection class: IP67 in conjunction with actuating element Certification: PTB 97 ATEX 1065 X 1) See Application /limitation Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 4 of 6

XI Illuminated button for installation on panel (front installation) with cover for connection cable Type 07-3363-5***/**** Rated operating AC 12V to 250V, DC 12V to 60V, AC/DC 12V to 24 V LED, red, green, yellow, white, blue. Ex protection class: II 2G Ex d e IIC T6 Gb, II 2 D Ex tb IIIC T80 C Db IP66 Ambient Temperature: -55 o C to +50 o C (-55 o C on request), +60 o C (AC/DC 12V to 24V) IP protection class: IP66 in conjunction with actuating element Type 05-0003-****/**** Certification: PTB 11 ATEX 1010 X, IECEx PTB 11.0025X For details: See manufacturer datasheet. Application /Limitation The Ex class shown can only be regarded as information and can not replace the requirement for Ex certificate case by case. With Uimp=6kV the max. rated voltage is 600 V when used in IT (ship) net. It can be used in applications with directly earthed systems with rated voltage of 400/690 V. Modules delivered with cables above 3 meters must be certified / reviewed case by case. Type Approval documentation Technical Info: BARTEC datasheets 03-0330-0431/A-07/10-BCS-240844, 03-0330-0431/A-07/10-BCS-240845, 03-0330-0431/A-07/10-BCS-240908, 03-0330-0191/A-10/2014-BCS-200865/1,../2,../3,../4,../5 &../6,, 03-0330-0189/A-10/2014-BCS-200863/1, &../2, 03-0330-0295/A-07/10-BCS-217100, 03-0330-0192 /A-07/10-BCS-200856, 03-0330-0296/A-07/10-BCS-217101, 03-0330-0828-10/2014-BCS-374342/1 & /2, 03-0330-0826-10/2014-BCS-374340/1 & /2, 03-0330-0829-10/2014-BCS-374343/1 & /2. Test reports /certificates: PTB EC-Type Eximination Certificate nos. PTB 97 ATEX 1064 U, PTB 97 ATEX 1064 X, PTB 05 ATEX 1064 U, PTB 05 ATEX 1065 X, CML 13 ATEX 3010 U, CML 14 ATEX 3073 X, IECEx PTB 10.0017 U, IECEx PTB 10.0014 U, PTB 02 ATEX 1159 / IECEx PTB 10.0043, PTB 11 ATEX 1010 X, IECEx PTB 11.0025X, IECEx CML 14.0005 U, IECEx CML 14.0029 X, KRIWAN Report no. 110592_01_B. Tests carried out Type tests in accordance with EN 50014, EN 50018, EN 50019, IEC 60079-0, IEC 60079-1, IEC 60079-7 & IEC 60079-11. Shock test in accordance with IEC 60068-2-27. Marking of product BARTEC - Type designation - Ratings (if applicable) Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 5 of 6

Periodical assessment The scope of the periodical assessment is to verify that the conditions stipulated for the Type approval is complied with and that no alterations are made to the product design or choice of materials. The main elements of the survey are: Inspection on factory samples, selected at random from the production line (where practicable) Results from Production Sample Tests (PST) and Routines (RT) checked (if not available tests according to PST and RT to be carried out) Review of type approval documentation Review of possible change in design, materials and performance Ensuring traceability between manufacturer s product type marking and Type Approval Certificate. Assessment to be performed at least every second year. END OF CERTIFICATE Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 6 of 6